Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹28.3 L+₹11,684 (0.41%)Rejected-Finance | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | L3₹28.4 L+₹25,894 (0.92%)Rejected-Finance | L3 | Rejected-Finance Quoted amount higher than L1 | |
| 4 | L4₹30.0 L+₹1.8 L (6.47%)Rejected-Finance | L4 | Rejected-Finance Quoted amount higher than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not fulfilled the NIT criteria |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col N K Chaudhary
HQ 137 WKS ENGR PIN 914137 CO 99 APO
REPAIR MAINT PAINTING PERIODICAL SERVICES OF 33 11 KV SUB STN INCLUDING SERVICING OF VCBs CAPACITOR BANK AND ALLIED WORKS AT RMS
2023_MES_598855_1
8795/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dimapur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 868 EWS
₹56,000
Yes
17 Aug 2023
27 May 2023
26 Jun 2023
27 May 2023
19 Jun 2023
12 Jun 2023
Amount
Material and labour for maint and servicing of EHV of Crompton Greaves, 33 KV, SF6, 630 Amps capacity, 3 pole, 750 MVA, outdoor type by drawing out from panel, removing carbon deposits from contact points by spraying CRC spray and tightening of fixed and moving contacts including adjusting of parts as reqd for smooth functioning complete all as specified and as directed. Note: (i) Servicing shall be carried out from OEM including testing/refilling of Gas pressure.
Material and labour for maint and servicing of HT, 11 KV, VCB panel of Crompton Greaves relays including calibration of IDMTL relays through primary and secondary injection method and testing complete including re-setting the timer & according to source/out going feeders. Where required and ensuring proper functioing of earth fault and overcurrent relays. Removing carbon deposits in the contact points, greasing and tightening all fixed and moving contacts for smooth functioning including opening and taking down UNSV parts/accessories meggering the value of CT and other accessories etc complete all as specified and as directed. Servicing shall be carried out from OEM complete all as specified and as directed. NOTE : (i)The spare parts reqd for repair/replacement shall be measured and paid as supply only under relavant items and fixing of the same is deemed to be inclusive in this Item. (ii) The servicing shall be carried out from authorised representative of OEM. (iii) Only the original spares as provided by OEM shall be used.
Supply only of set of isolating contact assy 630A complete all as specified and as directed.
Supply only of UPPER SUPPORT - 450025001 complete all as specified and as directed.
Supply only of LOWER SUPPORT complete all as specified and as directed.
Supply only of SPOUT BUSHING UP TO 1250A (1 SET-6 NOS) - 450088057 complete all as specified and as directed.
Supply only of SET OF 3 Nos. SPOUT BUSHING WITH CC PARTS (Contact Plug) UPPER 630/800 AMP complete all as specified and as directed.
Supply only of SET OF 3 Nos. SPOUT BUSHING WITH CC PARTS (Contact Plug) LOWER 630/800AMP complete all as specified and as directed.
Supply only of SPOUT BUSHING WITH CC PART FOR "R" ,"Y" & "B" PHASE LOWER 630A/800A complete all as specified and as directed.
Supply only of SPOUT BUSHING WITH CC PARTS UPPER 1600 AMP - UNIVAC- (SET OF 3 Nos) 450088032 + 450V5512Q complete all as specified and as directed.
Supply only of Emergency Push to Trip assembly for PANEL (Ref.- W.O. V6921) - TRIP CABLE complete all as specified and as directed.
Supply only of VI (3" Dia) Type WL 34599 M3+ complete all as specified and as directed.
Supply only of VI (4"Dia) Type VL 33379 -109 complete all as specified and as directed.
Supply only of MOTOR & GEAR ASLY 110V AC/DC UMG 14 TYPE (DELCO MAKE PMR-5) complete all as specified and as directed.
Supply only of HOLDING CATCH ASSEMBLY complete all as specified and as directed.
Supply only of PUSH BUTTON BRACKET ASSEMBLY complete all as specified and as directed.
Supply only of CHARGED/DISCHARGED INDICATOR ASSEMBLY complete all as specified and as directed.
Supply only of BIG & SMALL GEAR ASLY WITH MOTOR SHAFT complete all as specified and as directed.
Supply only of MOTOR CHARGED MECHANISM ASLY UMG-14 WITH MOTOR & OPERATING COILS (Single Trip)-- UPTO 26.3KA complete all as specified and as directed.
Supply only of MOTOR CHARGED MECHANISM ASLY WITH DELCO MOTOR & OPERATING COILS { SUITABLE FOR 40KA NEW VCB's- BENCHMARK MECHANISM} complete all as specified and as directed.
Supply only of SPRING CHARGING HANDLE FOR HAND OPERATING complete all as specified and as directed.
Supply only of CLOSING SPRING ASSEMBLY complete all as specified and as directed.
Supply only of TRIPPING SPRING ASSEMBLY-450171005 (1SET-2NOS) complete all as specified and as directed.
Supply only of BREAKER POSITIONING LEVER WITH VCB FREE TO CLOSE/TRIP KNOB (ROLLER CAM SWITCH WITH RED KNOB 2 N/O) complete all as specified and as directed.
Supply only of Motor Bracket for Hand charge complete all as specified and as directed.
Supply only of Upper Terminal Plate Square (12mm Thick) complete all as specified and as directed.
Supply only of Lower Terminal Plate Square (12mm Thick) complete all as specified and as directed.
Supply only of POWER PACK (INPUT-230 VAC - OUTPUT-24 VDC) complete all as specified and as directed.
Supply only of 11kV INDOOR PT PRIMARY FUSE (3.15A) complete all as specified and as directed.
Supply only of BUTTERFLY SWITCH FOR MOTOR CUT-OFF complete all as specified and as directed.
Supply only of TIMER FOR MOTOR complete all as specified and as directed.
Supply only of TEST SERVICE LIMIT SWITCH complete all as specified and as directed.
Supply only of LED LAMP-RED, of SAP Code : 460232452D complete all as specified and as directed.
Supply only of LED LAMP-GREEN of SAP Code 460232453D complete all as specified and as directed.
Supply only of LED LAMP-BLUE of SAP code 460232456D complete all as specified and as directed.
Supply only 11 KV Current Transformer IS-2705, current ratio 100/5+5 Amp, rated frequency 50 Hz, STC 18.4 KA for 1 Sec, indoor type complete all as specified and as directed.
Supply only of LED LAMP-AMBER of SAP Code 460232454D complete all as specified and as directed.
Supply only of LED LAMP-WHITE of SAP Code 460232457D complete all as specified and as directed.
Supply only of LED LAMP-YELLOW of SAP Code 460232460D complete all as specified and as directed.
Supply, install, testing of lightening arrestor metal oxide type suitable for 36 KV system discharge current 10 KA station class III, complete with all fitings, transmission class, discharge capacity 65 KA suitable for working voltage of 33000 Volts including all necessary fittings, including taking down of existing unserviceable lightening arrestor complete all as specified and as directed.
Material and labour for maint and servicing of APFC pannels of capicity 640 KVAR 11 KV online and their components, cleaning complete with blower and removing of deposited carbon particals from the terminals, adjusting relays and other parts up to certain limit as required and calibrated complete all as specified and as directed.
Supply and fix in repairs high voltage HRC fuse of 100 Amps for capacitor bank complete all as specified and as directed.
Supply and fix in repairs high voltage HRC of 200 Amps fuse for capacitor bank complete all as specified and as directed.
Supply and fix as in repair danger notice plate of 25x20cm size and 1.6mm thick mild steel sheet, vitreous enamelled white, with letters(Local & Hindi language), figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT pole complete all as specified and as directed.
Materials and labour for earthing complete with copper plate 600 x 600 x 3.15mm thick electrode and 20×3mm copper strip as earthing lead, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip 20x3mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set complete all as specified and as directed. Note:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of 32 x 6mm size by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate) with CI cover 10mm thick plate fixedto angle iron frame work including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessories all as specified and as directed. (Note: Earth strip upto a length of 7.50 m from earthplate shall be deemed to be included in quoted rate.)
Materials and labour for Copper strip 20 x 3.15mm with saddles and fixing screws etc.for roof conductors and down conductors above ground complete all as specified and as directed.
Material and labour for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed.
Material and labour for HT 11 KV (Earthed) grade heat shrinkable straight through jointing kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed.
M & L for painting the outer surface of the transformer of capacity ranging from 2000 KVA to 6000 KVA with one coat of corrosion resistant paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint complete all as specified and as directed.
M & L for painting the outer surface of the transformer of capacity ranging from 100-350 KVA with one coat of corrosion resistant paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint complete all as specified and as directed.
Material & Labour for preparation of old painted surfaces by scraping out old paint by emmery paper, caustic soda complete of HT 33/11 KV Four poles structure / cross arms, GOD pipe,clamps etc., and applying one coat of silver aluminium paint including painting of red & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and directed. Note : All angles and channels will also be painted under the quoted rate.
Material & Labour for preparation of old painted surfaces by scraping out old paint by emmery paper, caustic soda complete of HT 33/11 KV Two poles Structure / cross arms, GOD pipe,clamps etc., and applying one coat of silver aluminium paint including painting of red & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and directed. Note : All angles and channels will also be painted under the quoted rate.
Material & Labour for preparation of old painted surfaces by scraping out old paint by emmery paper, caustic soda complete of HT Steel poles / cross arms, GOD pipe,clamps etc., and applying one coat of silver aluminium paint including painting of red & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and directed. Note : All angles and channels will also be painted under the quoted rate.
Material & Labour for spreading and levelling of coarse graded stone aggregate (broken stone or boulders) of size 40 mm in sub - station yard to cover the complete area complete all as specified and as directed.
Removal of unwanted grass, plants and vegetations from E/M installations on Monthly basis for entire contract period including surface dressing and removal of grass ,plants and vegetations from site not less than 50mtr from starting point complete all as specified and directed (Note- (i) Removal of unwanted grass and vegetation will be repeated once a month (ii) Measurement shall be taken monthwise.)
S & F in repairs incl testing of swing out explusion fuse isolated assembly with fuse carrier out door type 11 KV supply 200 Amp ( DO Fuse ) incl mounting bracket & post insulator complete all as specified and as directed.
M/S Lucky Builders
commercial enterprises
APPLE CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .