Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.1 LAccepted-AOC KHUNMOH SRINAGAR PIN 191104 J K | SRINAGAR | SRINAGAR | J K | 191104 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹20.7 L+₹2.8 L (15.5%)Rejected-Finance C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-2 | Rejected-Finance Not being L-1. | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in requisite category. |
Tender Value
₹24.4 L
EMD Value
₹48,900
Closing Date
17 Jun 2024, 6:00 pmClosed
GE 861 EWS
GE 861 EWS c/o 56 APO
SPECIAL REPAIRS TO EM INSTALLATION CERTAIN BLDGS AT KHUNMOH KHREUH ALONGWITH LT PANELS HOT WATER SOLAR PLANT HIGH MAST LIGHT WITH ALLIED WK AND PROVISION OF URINAL POINT BEHIND BLDG NO T86 AT KHREUH UNDER GE 861 EWS
2024_MES_654673_1
GE 861 EWS-22/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE 861 EWS
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE 861 EWS
₹48,900
Yes
24 Sept 2024
17 May 2024
25 Jun 2024
17 May 2024
17 Jun 2024
3 Jun 2024
Amount
Demolition cement concrete (unreinfoced) in ground floor and pavings n.exc. 15cm thickness below or above ground level (including floor finishes) complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store complete all as specified and directed.
M&L for 25 mm thick PCC in CM (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in label of floor complete all as specified and directed.
M&L for Non skid ceramic coloured joint free tiles 7 to 8mm thick (square/ rectangular), area of each tiles exceeding 0.18 but not exceeding 0.38 in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles,laid over and including cement screed bed 15 mm thick in cement mortar (1:4) laying floor finish complete all as specified and directed.
S&F 450x350x7mm size coloured glazed wall tiles set and jointed in neat cement slurry and pointed with cloured cement to match as in vertical surface including 15mm thick rendering in cm 1:4 on vertical surface to receive wall finishes all as speceified.
M&L for Machine cut kota slab flooring 20-25 mm thick over 15 mm thick screed bed of CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 75mm thick, PCC 1:3:6 type C-2(using 40mm agg) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or concrete surface including raking out joints, hacking for key and scrubbing down with water complete all as specified and directed.
M&L for 10mm thick cement plaster on fair faces of brick work or conc surfaces in CM 1:6 finishing even & smooth w/o using extra cement complete all as specified and directed.
M&L for 15mm thick cement plaster on fair faces of brick work or conc surfaces in CM 1:4 finishing even & smooth w/o using extra cement complete all as specified and directed.
M&L for applying two coats of OBD over one coat of alkaline resistant primer (application of approved wall care putty 3mm thick to smooth & even surface) on new plastered surfaces incl preparation of surface of wall.
Material and labour for applying two coat of OBD to old treated plastered surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and gresay spots) (application of approved wall care putty 1mm thick to smooth & even surface) complete all as specified and directed.
M&L for two coats of cement base paint over a coat or alkalic resistance primer on newly plastered surface of wall incl preparation of surface complete all as specified and directed.
M&L for two coats of cement base paint on old plastered surface of wall incl preparation of surface complete all as specified and directed.
Taking down chowkhats or frames not exc. 1.5 Sqm but with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkat or frame with shutters (without taking shutter from the frame) exceeding 1.5sqm and not exceeding 4.00 sqm each complete all as specified and directed.
M&L for 2nd class hard wood, plain solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F Factory made solid PVC door frame of size 50mm x 47mm made out of 5 mm single side prelam PVC sheet reinforced with MS square tube manufactured as per SSR Part-I specifications and drawings complete all as specified and directed.
S&F factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail lock rail and bottom rail on either side and gap insert for top rail and bottom rail paneling of plain colour PVC to sheet to be fitted in the MS frame welded / sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed.
S&F IInd class hard wood 35mm thick factory made plain framed paneled shutter with lock rail and pannel of 9mm BWP commercial ply or 12mm veneered particle board with commercial faces on both faces the size of rails and stile as per IS-1003 (Part-1)kline seasoned and chemically pressure treated complete all as specified and directed.
S&F for 30 mm thick 2nd class hard wood glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc windows/ventilators, devide into square with plain chamferred or rounded, mitered and rebated sash bars any numbers , provided with stiles and rails as specified in SSR part I section 8 clause 8.24 (b). .
S&F aluminium anodised barrel tower bolts extruded section of size 200 mm, complete all as specified and directed.
S&F aluminium anodised barrel tower bolts extruded section of size 75 mm, complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt of length 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed
S&F butt hinges 100mm medium weight cold rolled mild steel and fixed complete all as specified and directed.
S&F butt hinges 75mm medium weight cold rolled mild steel and fixed complete all as specified and directed.
S&F mild steel 300mm size ordinary rat tail pattern springs incl roller and roller plate complete fixed in repair complete all as specified and directed.
Hacking out old or broken glass (any thickness size quility or description) from steel frmes or stone concrete or brick surounds glazed with putty or fixed with beads complete all as specified and directed.
S&F 4mm thick sheet glass of ordinery quality and glazing with oil putty in nexc 0.5sqm each in pane complete all as specified and directed.
Taking up or down steel tubing and connection incl cleaning for refixing or removal to store15mm bore complete all as specified and directed.
S&F 15mm bore GI tubing medium grade with all fittings fixed to walls ceiling or laid in trenches complete all as specified and directed.
Taking up or down steel tubing and connection incl cleaning for refixing or removal to store20mm bore complete all as specified and directed.
S&F 20mm bore GI tubing medium grade with all fittings fixed to walls ceiling or laid in trenches complete all as specified and directed.
S&F in repair PVC valve less 10 liter capacity symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed.
S&F in repaired vitreous china wash down water closet pan ( pedestal pattern ) white complete including ‘P’ or ‘S’ trap , seat cover and fixing to flushing cistern, brackets, flushing pipe etc complete all as specified and directed.
Dismantling water storage tanks of any description/ exc 250 & n exc 500 liters capacity and removing from site complete all as specified and directed.
S&F for Rotational moulded polythylene 500 liters capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20 mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball complete all as specified and directed.
Supply and fixing in repair grating doom 125mm dia with waste hole of PTMT weight not less than 40mm each complete all as specified and directed.
S&F in repair PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F in repair PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F in repair PVC bends 110 mm bore complete all as specified and directed complete all as specified and directed.
S&F in repair PVC bends 75 mm bore complete all as specified and directed.
S&F in repairs 15 mm bore fency type CP bib taps cast copper alloy with crutch or butterfly nuts with chromium plated , handle, screwed down for iron pipe complete all as specified and directed.
S&F in repairs, 15 mm bore CP stop/angle valve cast copper alloy screwed down , high pressure with crutch or butterfly handle fancy type complete all as specified and directed.
S&F in repair health faucet CP Brass hand Jet Shower 15mm bore dia and 1500mm long CP pipe complete all as specified and directed.
Preparation of new or untreated wood or wood based surfaces of any description exc.10 cm. in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for Preparation of old surfaces of ceiling plastered or unplastered incl brooming down or steel wire brushing scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of white wash on ceiling complete all as specified and directed.
M&L for preparation of old painted on wooden surfaces of any description not otherwise described for over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
-Ditto_ all as per item No 49 but on steel surfaces complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness including roof covering etc complete all as specified and directed.
S&F for galvalume aluminium zinc coating GI based pre-painted corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed. (Make : Crill/Tata Blue scope) complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as spd complete all as specified and directed.
M&L for in repairs for weather boarding in 2nd class hardwood clean swan , plain , 20 mm thick or feather edges , 15 mm to 20 mm thick and fixed with 30 mm laps joints complete all as specified and directed.
Dismantling of wall and ceiling boards (fiber, pulp, insulation, etc) or insulation boards/slabs including cover fillets etc complete all as specified and directed.
S&F for anodised aluminium snap grid of size 605 x605 mm frame work for false ceiling including straining with GI wire 4 mm thick all as specified complete all as specified and directed.
S&F for 10 mm thick PVC insulation panels with EPS stuck to 1 mm thick plain PVC sheet suitably placed in false ceiling grid made of aluminum GI/MS as per specification and drawing complete all as specified and directed.
Surface dressing n exe 15 cm deep in hard/dense soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 depth for foundation etc or for shafts well cesspits manholes pier holed etc 10 Sqm on plan and n.exc 1.5m in depth and getting out in hard and dense soil complete all as specified and directed.
M&L PCC 1:4:8 type D2 using 40 mm graded aggregate in Foundation filling and mass concrete / Bed concrete complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed.
M&L for preparing new plastered surface of wall and applying three coats of white wash on walls etc complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for broken stone hard core of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15cm thick, watered and well rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base, floors and pavings etc. complete all as specified and directed.
M&L for Non skid ceramic coloured joint free tiles400mmx400mm 7to 8mm thick (square/ rectangular), in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles,laid over and including cement screed bed 15 mm thick in cement mortar (1:4) laying floor finish complete all as specified and directed.
M&L for Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S&F vitreous china bowl urinal half stall type , white , with grating and union for discharge pipe (excluding high level PVC flushing system,) including PVC waste pipe, 32mm dia & waste coupling size and shape approved by GE , all as specified & directed complete all as specified and directed.
S&F roof trusses (framed), trussed, purlins,crane gantries, rails and fastnings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 290 Gde E-165 complete all as specified and directed.
S&F framed work such as grills, grating etc with guard bars,feamed guard bars, hold fasts, railing, framed work of water tanks and similar work confirming to Fe-290 gde-E165 complete all as specified and directed.
M&L for two coats of synthetic enamel paint on NEW STEEL surfaces over coat of red-oxide primer including preparation of surfaces, over 10cm width or girth including preparing roof painting complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded aggregate ) as in sub for receiving floor finishes etc complete all as specified and directed.
M&L for chequerd cement concrete tiles 30cm x30cmx25mm th with grey cement and pigment , set , jointed and pointed in neat cement slurry in floors laid over 15 mm thic screeed bed in cm 1:6 complete all as specified and directed.
S&F for Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
S&F Vitreous china wash hand basin, white, flat back, size 550 x 400 mm with brackets, including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. (Including 15mm bore CP pillar tap, waste coupling and 32mm dia PVC waste pipe) and vitreous china pedestal complete all as specified and directed.
S&F 15 mm size PV C connection with PTMT nuts of 600 mm long complete all as specified and directed.
S&F 75 mm diameter of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent in cement concrete (1:2:4) type B1 complete all as specified and directed.
S&F 20 mm bore CP stop/angle valve cost copper alloy screwed down, high pressure with crutch or butterfly handle fency type complete all as specified and directed.
S&F PVC (SWR) bends any radius complete all as specified and directed.
M&L for PCC 1:2:4 type B-1, (using 20mm graded aggregate) as in coping , benching, haunching including all necessary form work complete all as specified and directed.
M&L for Precact cement concrete 1:2:4 type B1 (Using 20mm graded granite stone aggregate ) in landings, cover slabs ( for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for pipes of 150 mm bore complete all as specified and directed.
M&L for 150 mm dia Salt Glazed stone ware drain pipes laid in trenches and jointed as specified complete all as specified and directed.
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil not exceeding 50 m distance and depositing where directed at alevel n exc 1.5 metre above the starting point complete all as specified and directed.
M&L for point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in PVC casing & capping and including pipe hooks , elbows, junction covers and junction boxes , after fixing or cutting on wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes 60mm deep ,suitable length and thickness for mounting, switches, sockets, fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly fixed on wall or grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly.
All as per srl item No-87 here in above but for one 5A socket outlet on the same board controlled by one switch.
All as per srl item No- 87 here in above but for one 3 pin 5A socket outlet independent controlled by one switch.
Description all as per item No 87 above but for 3 pin socket outlet 15 Amps independent board with 2.5 Sqmm.
S&F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FR/FR/FRLS stranded copper conductor drawn in surface PVC conduict /casing capping of size 20mm “medium quality” conduit including 4.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after fixing or chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. (Note : PVC cable and PVC conduit shall be ISI marked).
S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engineer - in - Charge complete all as specified and directed.
S&F for Switch Socket combination, 3 pin 16 amps multi purpose 2 in 1 flush type, 230 volts complete all as specified and directed.
S&F for Switch Socket combination 2 in 1, 6 Amps flush type, 230 volts complete all as specified and directed.
S&F socket outlet 3 pin, 5 Amp, flush type complete all as specified and directed.
S&F ceiling rose surface bakelite three terminals complete all as specified and directed.
Supply and fixing fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed.
S&F LED lights fitting 1x20W, 230V, AC decorative box type with drive, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED lights fitting 1x10W, bulkhead luminiaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete ase of suitable size from ceiling rose complete all as specified and directed.
S&F energy exhaust fan 300 mm sweep strudy engineering plastic complete with with lovers shutters, voltage 230V, 50Hz, RPM 1200, copper winding making hole in wall as it where required and , connecting electrically to ceiling rose or connector block using PVC insulated and overall sheathed 3 core cable of size 0.75 Sqmm with flexible copper conductor all as required at site and old UNSV Exhaust fan from building depositing to MES store yard complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe ( PVC connection of 15 mm bore with PTMT nut of length 450 mm suitable for hot water and cold water for geysers) including fixing arrangement like clamps , nuts, bolts washers, suitable type of fastner and making good the disurbed surfaces as per existing etc old UNSV geysers from building depositing to MES store yard complete all as specified and directed.
Supply and fixing sheet metal enclosure with socket plug top single phase and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20 amps, B curve complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board, double door with IP -43 protection single phase 240 volts 8 way,including suitable size copper bus bar and neutral link make . Standatd/ Havell's/Legrand fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Supply and fix in replacement MCB SPN, 240 volts any rating from 40-63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB single pole 240 volts 6 to 32 amps as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), disconnect upper and lower terminals , integrated label holder to ensure circuit identification complete all as specified and directed.
S&F in replacement 4 pole AC MCCB ,415 volts, 400 Amps 3 Phase 50 hz rated in Panel complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanised iron strip 25×4mm means of bolts, nuts check nut & washers of galvanised iron or steel & connected to main switch including complete excavation and earth work in soft/loose soil and disposal of surplus soil to a distance not exc 50 meters, PCC Chamber (1:3:6) type C-2 precast RCC cover with frame, funnel wire mesh, 20mm bore light grade galvanised iron or steel pipe for water, charcoal or coke and salt in alternative layers of 15cm compacted thickness all round the earth electrode complete alll as shown in electrical plate No 3 of SSR part-I including welding with suitble electrode and testing complete all as directed. NOTE :- (i) Main earthing strip from earth plate electrodeto test point upto length of 7.5 mtrs length shall deem to be included in the unit rate quoted against this item. (ii) M&L Tubing GI med grade 40mm dia for protection of earthing strip and passing the Road/passes and etc.shall deem to be included in the unit rate quoted against this item. (iii) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department .
M&L for earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.0mm thick busied directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6 mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shora all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. Note:- (i) Main earthing lead from earth plate electrode to test point up to length of 7.5 meters length shall deem to be included in the unit rate quoted against this item . (ii) GI protection pipe & earthing lead beyond 7.5 meter shall be measured and paid for separately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department .
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, ,removing material to store for keeping in safe custody and making good to disturbed surfaces complete all as specified and directed.
S & F in replacement lamp holder PVC/polycarbonate insulated body type complete all as specified and directed.
Supply and fixing of in replacement of LED 7 watt pin type bulb complete all as specified and directed.
Supply and laying or fixing in replacement or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2x10 sq. mm nominal cross section in service connections complete all as specified and directed.
S&F in replacement of double door type SPN DB 08 Way ,240V with 100A copper busbar each phase , with metalic double door type IP-43 IK 09 protection suitable for housing MCB's all as specified and directed by EIC,Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding complete all as specified and directed.
S & F in replacement MCB SP 6-32 Amps,10KA, 'B' series 240V complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor complete all as specified and directed.
Supply and fixing,in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F laying in trenches, pole, and along wall etc complete,XLPE insulated, armoured heavy duty electric cable with strended aluminium conductor,1100 volt grade,cross sectinal area 10 sq mm 2 core complete all as specified and directed..
M&L for Excavation in trenches in n. exc 1.5 mtr vide and 1.5 mtr in depth and getting out in soft/loose soil for laying of U/G cable complete all as specified and directed.
M&L for sand cushing in trenches for cable protection complete all as specified and directed.
M&L for Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all as specified and directed.
S&F GI water tubing medium grade (ISI marked) laid in trenches incl fittings as required as site and including jointing internal as specified of size. (a) GI tubing 40 mm dia bore
S&F sheet metal enclosure MCB distribution board, double door with IP -43 protection single phase 240 volts 4 way,including suitable size copper bus bar and neutral link make . Standatd/ Havell's/Legrand fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification.
Supply and fabricate, installation, connection, testing and commissioning in replacement of LT electrical panel board in repair, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, outdoor type, fabricated with 3.15.0mm thick made of CRCA, powder coated , CPRI Approved , bottom with detachable plates, front and rear with hinged type double door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars 375 amps for phases and 250 amps for neutral, insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated and suitable size of stranded copper conductor cable, complete mounted on PCC foundation, supporting channel,and outgoing with thimble/lugs, including the accessories as below complete and mountig the panel on ground/floor with PCC(1:3:6) bedding upto a height of 30 cm above ground level and 30 cm in foundation complete all as specified and directed directed by Engr-in-Charge. cable termination, cable gland etc, complete (Feeder Panel) including taking out old unsv panel, complete all as specified and comprising of the followings: Note : The cost of thimbles/lugs and cable gland,Pcc for panel base etc is incl in quoted rate for connection for cable and no extra payment will be made for it. a) MCCB 630 Amps 4pole,50 KA,Thermal magnetic - 1 No (Incomer) b) MCCB, 4 Pole 200 Amps,35 KA,Thermal magnetic - 02 Nos (Out going) c) MCCB, 4 Pole 160 Amps,25 KA,Thermal magnetic - 02 Nos (Out going) d) MCCB, 1 Pole 100 Amps,25 KA,Thermal magnetic - 02 Nos (SPR) e) Volt meter , digital type ,0 - 500V - 1 Nos f) Ammeter, digital type with CT's - 1 No g) indication lamps (R,Y,B) LED type - 1 set
Supply and fabricate, installation, connection, testing and commissioning in replacement of LT electrical panel board in repair, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, outdoor type, fabricated with 3.15.0mm thick made of CRCA, powder coated , CPRI Approved , bottom with detachable plates, front and rear with hinged type double door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars including aluminium bus bars 150 amps for phases and 100 amps for neutral, insulated with coloured PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated and suitable size of stranded copper conductor cable, complete mounted on PCC foundation, supporting channel,and outgoing with thimble/lugs, including the accessories as below complete and mountig the panel on ground/floor with PCC(1:3:6) bedding upto a height of 30 cm above ground level and 30 cm in foundation complete all as specified and directed directed by Engr-in-Charge. cable termination, cable gland etc, complete (Feeder Panel) including taking out old unsv panel, complete all as specified and comprising of the followings: Note : The cost of thimbles/lugs and cable gland,Pcc for panel base etc is incl in quoted rate for connection for cable and no extra payment will be made for it. Incoming (a) MCCBs 4 pole, 415 volts grade,100 Amps rating and 36 KA rupturning capacity adjustable thermal setting :01 Nos Outgoing (a) MCCBs 4 pole, 415 volts grade, 63Amps rating and 16 KA rupturning capacity adjustable thermal setting :02 Nos
S&F in replacement of energy saving environment friendly long life exclusive innovative die cast aluminium non integral IP 66 highbay suitable for high mast application 200 watt LED light item complete all as specified and directed.
M&L for, lowering Raising system comprising double drum winch of any size SS wirer rope trailing cable connector,intergal power tool motor manual handel for lightening finial included in quoted rate and Gressing of SS wire of any size of any length,complete all as specified and directed.Note : All necessary T&P items will be arrange by contractor at site, No extra payment will not be paid for this.
S&F in replacement of low intensity LED type twin dome aviation obstruction light complete all as specified and directed. Note : All necessary T&P items will be arrange by contractor at site, No extra payment will not be paid for this.
S&F in replacement 100 A TPN MCB Incomer, and for existing panel single dial time switch, 20 A TP suitabel contector,relays and suitable size of timer for the automatic switching of luminaries, power tools control with 2 no 9A contactors and raise lower push button, power socket, incoming 35sq.mm and outgoing 16 & 2.5 sq.mm terminals, complete all as specified and directed. Note :The cost of thimbles/lugs and cable gland,Pcc for panel base etc is incl in quoted rate for connection for cable and no extra payment will be made for it.
Taking Down of FPC & ETC type Solar water heating system,complete with heat exchanger of any capacity ,with electrical heating back up complete all as specified and directed.
Supply,& Installation, in replacement of Flat Plate collector complete type ,with heat exchanger of existing capacity ,with electrical heating back up complete all as specified and directed. Any MES approved makes as sample approved by the Accepting officer.
Supply,& Installation, in replacement of ETC complete type of any/ Existing capacity ,with electrical heating back up complete all as specified and directed. Any MES approved makes as sample approved by the Accepting officer.
Supply and Installation in replacement of solar hot water tank of capacity 500 Ltrs made of 1 mm SS304 With coil type heat exchanger made of SS304 having 50 mm puf insulation including necessary strcture and finishing work with outer cladding of PPGI sheet, foundations, Electrical connection and other safety device such as thermostate relay etc, complete all as specified and directed. Any MES approved makes as sample approved by the Accepting officer.
M&L for solar water heater of existing capacity including checking serviceability of FPC and ETC panel choking cleaning and adding heat transfer, chemical( glycol) suitable grade with top up of suitable capacity ,replacement of defective items such evacuted tube, flat plate, nuts, washer, gasket, end bracket, insulation, reflectro of any size, complete all as specified and directed. Any MES approved makes as sample approved by the Accepting officer.
Supply and laying in replacement of fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2x6 sq. mm nominal cross section in service connections,complete all as specified and directed.
M/S A.N CONSTRUCTIONs
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .