Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹2.7 Cr | L1 | Accepted-AOC Lowest Rates |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Similar Nature of work not found attached |
| Sl No | Description | Qty | Unit | Himmat Singh Contractor L1 |
|---|---|---|---|---|
| 1.00Works Details | ||||
| 1.10 | Less credit of old Steel | 2,198 | Kg | 31 ₹-68,138 Lowest |
| 2.00 | Re- Development of Lawn, The OHSR situated at Town Park Jakhal Mandi | 1 | Job | 70,000 ₹70,000 Lowest |
| 3.00 | `Cloud based software comprising of Middleware, Database and Front-end web interface through suitable Dashboards, Aggregation screens and GIS assisted drill-down from macro to micro to be provided. Application data hosting and maintenance for Five years included in scope.
Cloud services of Ministry of Electronics and Information Technology (Meity), Government of India empaneled cloud service providers shall be taken like Microsoft, Amazon, Google, BSNL etc. Cloud service provider must adhere the security standards and guidelines issued by Meity from time-to-time. As the data belongs to the State Government of Haryana, therefore the application and data hosted on Cloud must be kept and stored in data centres located in India only. Any change in application requirement or infrastructure shall be borne by the Implementation agency. Implementation agency shall carry out the Application Security Audit from a Certified Auditor (CA). Application and data shall be kept confidential and only the authorized users shall have the access to it. Implementation Agency shall be responsible for any data theft or data leakages ` | 1 | Each | 15,00,000 ₹15,00,000 Lowest |
| 4.00 | Designing, fixing, commissioning and auto switchover chlorination system, Chlorine dry scrubber, auto shut off valve, chlorine gas cylinder and chlorine gas leak detector and all other works contingent thereto (Chlorinator). As per latest approved Technical Specification from Head Office vide letter No. 23070
-23142 Dt. 28/02/24 with reference to IS Code 10553(2) -1983a | 2 | Job | 12,00,000 ₹24,00,000 Lowest |
| 5.00 | Credit of Old Panel Board.. | 10 | Each | 10,000 ₹-1,00,000 Lowest |
| 6.00 | Supply of Water Meter inclusive all taxes. | 3,405 | Each | 1,400 ₹47,67,000 Lowest |
| 7.00 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 40 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Push button red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. [For T/W No. 8,9,(against failure) 11 and 12 (Proposed)]. | 4 | Each | 1,55,000 ₹6,20,000 Lowest |
| 8.00 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 30 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Push button red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. [For T/W No. 10 Civil Hospital (Existing)]. | 1 | Each | 1,35,000 ₹1,35,000 Lowest |
| 9.00 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 25 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Push button red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. [For T/W No. 1,3,4,5,6 and 7 (Existing)]. | 6 | Each | 1,10,000 ₹6,60,000 Lowest |
Tender Value
₹3.0 Cr
EMD Value
₹5.9 L
Closing Date
27 Jun 2025, 2:00 pmClosed
ADARSH KUMAR SINGLA
Tohana PHED
Jakhal Town - Providing and Installation of Four Nos. Deep Tubewell out of which Two nos. Additional Deep Tubewell and Two Nos. Deep Tubewell against Failure in Tubewell and Providing and Laying of Water Supply Pipe Line at Jakhal Town, Distt - Fate
2025_HRY_452912_1
2025CD543801 392C 4E60 9DD0 41EDD588573C585PUH
Open Tender
Civil Works
Works
450 days
Jakhal Jakhal
2 documents required · 2 mandatory
₹15,000
₹5.9 L
Yes
27 Aug 2025
17 Jun 2025
27 Jun 2025
17 Jun 2025
27 Jun 2025
17 Jun 2025
17 Jun 2025 - 27 Jun 2025
Amount
Works Details
Less credit of old Steel
Re- Development of Lawn, The OHSR situated at Town Park Jakhal Mandi
`Cloud based software comprising of Middleware, Database and Front-end web interface through suitable Dashboards, Aggregation screens and GIS assisted drill-down from macro to micro to be provided. Application data hosting and maintenance for Five years included in scope. Cloud services of Ministry of Electronics and Information Technology (Meity), Government of India empaneled cloud service providers shall be taken like Microsoft, Amazon, Google, BSNL etc. Cloud service provider must adhere the security standards and guidelines issued by Meity from time-to-time. As the data belongs to the State Government of Haryana, therefore the application and data hosted on Cloud must be kept and stored in data centres located in India only. Any change in application requirement or infrastructure shall be borne by the Implementation agency. Implementation agency shall carry out the Application Security Audit from a Certified Auditor (CA). Application and data shall be kept confidential and only the authorized users shall have the access to it. Implementation Agency shall be responsible for any data theft or data leakages `
Designing, fixing, commissioning and auto switchover chlorination system, Chlorine dry scrubber, auto shut off valve, chlorine gas cylinder and chlorine gas leak detector and all other works contingent thereto (Chlorinator). As per latest approved Technical Specification from Head Office vide letter No. 23070 -23142 Dt. 28/02/24 with reference to IS Code 10553(2) -1983a
Credit of Old Panel Board..
Supply of Water Meter inclusive all taxes.
`Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. Size in MM @ quantity 1 no. Each 150 mm`(Electromagnetic Flowmeter at T/Well no. 1, 2, 3, 4, 5, 6, 7, 8, 9 and 10)
NS Item -Supply, Installation, testing, Commissioning with Five-year maintenance of Hydrostatic Depth Sensor (for determining water level in tube wells) Measuring range – As per requirement Pump End, Output – 4 to 20 mA at T/Well no. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 and 12
SIM Card for Five year operation of all the instrument above as required.(At T/Well no. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 and 12)
Supply, Installation, Testing, Commissioning with Maintenance of five year of Online Chlorine Sensor to be installed at Pump End/Source. (At T/Well no. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 and 12)
Supply, Installation, testing, Commissioning with Maintenance of five year Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement. (IP-68), RS-485 ModBus. Line Size, installed at Pump End/Source. Size in MM @ quantity 1 no. Each 200 mm` Electromagnetic Flowmeter at T/well No. 11 and 12
Supply, Installation, testing, Commissioning with Maintenance of five year of Pressure Transmitter along with its installation complete in all respect as per specifications. Measuring range – 10 kg/cm2, Output – 4 to 20 mA, to be installed at tail end/remote location (At T/Well no. 1, 2, 3, 4, 5, 6, 7, 8, 9 and 10)
Bidder Name
Amount
Himmat Singh Contractor (GSTN-NA) BID ID -1286190
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tenderdocument.pdf
Tender Documents • 0.98 MB
BOQ.xls
BOQ • 0.34 MB
Tenderdocument_2.pdf
Tender Documents • 0.98 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .