The Special Chief Engineer
The Superintending Engineer, PWD., Buildings Construction and Maintenance Circle,Tiruvannamalai-4.
Providing Electrical Installation to the Second floor, Third floor and Fourth floor of RHTC Building in HMDI Campus at Villupuram in Villupuram District.
2023_PWD_380341_1
32/TVM-CLE/23-24/1/ Dt.09.10.2023
Open Tender
Electrical Works
Lump-sum
90 days
VILLUPURAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹12,400
4 Jan 2024
18 Oct 2023
27 Oct 2023
18 Oct 2023
27 Oct 2023
18 Oct 2023
Amount
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End
Supply and fixing of bulk head fitting suitable for 7W LED with bulb.
Supply and fixing of single box type 4' 18 W LED fitting complete with TW round blocks on wall or ceiling with 18 W LED tube light with single side connection ( Havells / equivalant) with PVC unsheathed Copper leads from terminals to the fitting.
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp
Supply and fixing of 300 mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall
Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty) AC exhaust fan.
Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug)
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End
Supply and fixing of Vertical type 8way Triple pole and neutral MCB Double door Distribution board in sheet steel enclosure with metal door with IP42 protection with 1 No. of 32A FP MCB Isolator as incoming and 24 Nos. of 6A to 32A SP MCB outgoing on wall with suitable angle iron framework with Cable entry box on top or bottom with earth connection only. The MCB DB and MCB's should be with Legrand / Hager make only
Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 4 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply and Run of 4 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Rajasekar
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .