Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H2₹40.0 CrAccepted-AOC | ₹40.0 Cr | H2 | Accepted-AOC H2 |
| 2 | H1₹43.8 CrRejected-AOC | ₹43.8 Cr | H1 | Rejected-AOC H1 |
| 3 | Not Admitted-Fee/PreQual/Technical OFFICE NO 515 PLOT NO 194 NMS ICON SECTOR 19 ULWE NAVI MUMBAI MAHARASHTRA 410206 | NAVI MUMBAI | THANE | MAHARASHTRA | 410206 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical YOGESHWARI NAGARI RING ROAD AMBAJOGAI | AMBAJOGAI | BEED | MAHARASHTRA | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹35.1 Cr
EMD Value
₹17.6 L
Closing Date
8 Sept 2023, 6:00 pmClosed
Executive Engineer
Executive Engineer P. W. Building Division, Wakdewadi at Govt. Milk Scheme Campus Pune 3
Construction of Administration and Residential Building for State Excise Dept at Mangalwar Peth Pune Phase 1
2023_PWDRP_936316_1
E-Tender Notice No. 9 for 2023-24
Open Tender
Civil Works
730 days
Mangalwar Peth Pune
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
₹17.6 L
Chief Engineer P. W. Region Pune 1
26 Feb 2024
18 Aug 2023
12 Sept 2023
18 Aug 2023
8 Sept 2023
18 Aug 2023
29 Aug 2023
Amount
ITEM No1: Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. Spec : As directed by Engineer In Charge D.S.R. I.No 21.34 BDW Page No 157 For Admin Building
For Item No.1 Residential Building
ITEM No2: Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. including all leads and lifts By Mechanical Means Spec. No: Bd.A.1 Page No 259 D.S.R. I.No 21.02 BDA 1 Page No 153 For Admin Building
For Item No.2 Residential Building
ITEM No3: Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. including all leads and lifts By Mechanical Means Spec. No: Bd.A.1 Page No 259 D.S.R. I.No 21.04 BDA 1 Page No 153 For Admin Building
For Residential Building For Item No.3
ITEM No4: Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. including all leads and lifts By Mechanical Means Spec. No: Bd.A.1 Page No 259 D.S.R. I.No 21.04 BDA 1 Page No 153 For Admin Building
For Item No.4 Residential Building
ITEM No5: Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.including all leads and lifts By Mechanical Means Spec. No: Bd.A.1 Page No 259 D.S.R. I.No 21.04 BDA 1 Page No 153 For Admin Building
For Item No.5 Residential Building
ITEM No6: Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. including all leads and lifts By Mechanical Means Spec. No: Bd.A.1 Page No 259 D.S.R. I.No 21.04 BDA 1 Page No 153 For Admin Building
For Item No.6 Residential Building
ITEM No7: Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. including all leads and lifts By Mechanical Means Spec. No: Bd.A.1 Page No 259 D.S.R. I.No 21.04 BDA 1 Page No 153 For Admin Building
For Item No.7 Residential Building
ITEM No8: Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. including all leads and lifts By Mechanical Means Spec. No: Bd.A.3 Page No 259 D.S.R. I.No 21.12 BDA 3 Page No 154 For Admin Building
For Item No.8 Residential Building
ITEM No9: Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. completeincluding all leads and liftsBy Mechanical Means Spec. No: Bd.A.3 Page No 259 D.S.R. I.No 21.16 BDA 4 Page No 154 For Admin Building
For Item No.9 Residential Building
ITEM No10: Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. including all leads and lifts By Mechanical Means Spec. No:Bd.A.6 Page No 260 D.S.R. I.No 21.20 BDA 6 Page No 154 For Admin Building
For Item No.10 Residential Building
Item No-11:- Conveying building rubbish and debris up to 10km from work site including loading and unloading etc complete. D.S.R. Statement C1 Page No 560 Admin Building Basement Floor-1
For Item No.11 Basement Floor-2-Admin Bldg
For Item No.11 Ground Floor-Admin Bldg
For Item No.11 Residential Building Basement Floor-2
ITEM No12: Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. Spec : As directed by Engineer In Charge D.S.R. I.No 21.22 BDW Page No 155 For Admin Building Basement Floor-1
For Item No.12 Residential Building Basement Floor-1
For Item No.12 Admin Building Basement Floor-2
For Item No.12 Residential Building Basement Floor-2
ITEM No13: Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. Spec : As directed by Engineer In Charge. D.S.R. I.No 21.23 BDW Page No 155 Admin Building Basement Floor-1
For Item No.13 Residential Building Basement Floor-1
For Item No.13 For Admin Buidling Basement Floor-2
For Item No.13 For Residential Building Basement Floor-2
ITEM No14: Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.). Spec. No: Bd. E. 1 Page No 287 D.S.R. I.No 24.01 BDE 1 Page No 175 For Admin Buidling Basement Floor-2
For Item No.14 For Residential Building Basement Floor-2
ITEM No15: Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully SCADA concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.). Spec. No: Bd. E. 1 Page No 287 D.S.R. I.No 24.01 BDE 1 Page No 175 Admin Building- GSR
For Item No.15 For Residential Building GSR
ITEM No16: Providing and laying in situ /Ready Mix cement concrete M-35 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.). Spec. No: Bd.F.3 Page No 298 and B.7, Page No38 D.S.R. I.No 25.17 BDF 3 Page No 179 For Admin Building Basement Floor-2
For Item No.16 For Residential Building Basement Floor-2
ITEM No.17: Providing and laying in situ /Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.). Spec. No.: Bd.F.3 Page No. 298 and B.7, Page No.38 D.S.R. I.No. 25.15 BDF 3 Page No. 178 For Admin Building GSR
For Item No.17 For Residential Building GSR
ITEM No18: Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.). Spec. No: Bd.F.5 Page No 300 and B.7, Page.No 38 D.S.R. I.No 25.37 BDF 5 Page No 180 Admin Building Basement Floor-1
For Item No.18 For Residential Building Basement Floor-1
For Item No.18 For Admin Building Basement Floor-2
For Item No.18 For Residential Building Basement Floor-2
For Item No.18 For Admin Building Ground Floor
For Item No.18 For Residential Building Ground Floor
For Item No.18 For Admin Building 1st Floor
For Item No.18 For Residential Building 1st Floor
For Item No.18 For Admin Building 2nd Floor
For Item No.18 For Residential Building 2nd Floor
For Item No.18 For Admin Building 3rd Floor
For Item No.18 For Residential Building 3rd Floor
For Item No.18 For Residential Building 4th Floor
ITEM No19: Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.). Spec. No: Bd.F.6 Page No 300 and B.7, Page No38 D.S.R. I.No 25.56 BDF 6 Page No 182 Admin Building Basement Floor-1
For Item No.19 For Residential Building Basement Floor-1
For Item No.19 For Admin Building Basement Floor-2
For Item No.19 For Residential Building Basement Floor-2
For Item No.19 For Admin Building Ground Floor
For Item No.19 For Residential Building Ground Floor
For Item No.19 For Admin Building 1st Floor
For Item No.19 For Residential Building 1st Floor
For Item No.19 For Admin Building 2nd Floor
For Item No.19 For Residential Building 2nd Floor
For Item No.19 For Admin Building 3rd Floor
For Item No.19 For Residential Building 3rd Floor
For Item No.19 For Residential Building 4th Floor
ITEM No20: Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). with fully automatic micro processor based concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.) Spec. No: Bd.F.8 Page No 302 and B.7, Page No38. D.S.R. I.No 25.76 BDF 8 Page No 183 For Admin Building Basement Floor-1
For Item No.20 For Residential Building Basement Floor-1
For Item No.20 For Admin Building Basement Floor-2
For Item No.20 For Residential Building Basement Floor-2
For Item No.20 For Admin Building Ground Floor
For Item No.20 For Residential Building Ground Floor
For Item No.20 For Admin Building 1st Floor
For Item No.20 For Residential Building 1st Floor
For Item No.20 For Admin Building 2nd Floor
For Item No.20 For Residential Building 2nd Floor
For Item No.20 For Admin Building 3rd Floor
For Item No.20 For Residential Building 3rd Floor
For Item No.20 For Residential Building 4th Floor
ITEM No.21: Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). with fully automatic micro processor based concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.) Spec. No.: Bd.F.8 Page No. 302 and B.7, Page No.38. D.S.R. I.No. 25.74 BDF 8 Page No. 183 For Admin Building GSR
For Item No.21 For Residential Building GSR
ITEM No22: Providing and laying Cast in situ/Ready Mix cement concrete in M-35 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.) Spec. No: Bd. F. 13 Page No 305 /I.S. 456 (2000 D.S.R. I.No 26.26 BDF 13A Page No 186 Admin Building Basement Floor-1
For Item No.22 For Residential Building Basement Floor-1
For Item No.22 For Admin Building Basement Floor-2
For Item No.22 For Residential Building Basement Floor-2
For Item No.22 For Admin Building Ground Floor
For Item No.22 For Residential Building Ground Floor
For Item No.22 For Admin Building 1st Floor
For Item No.22 For Residential Building 1st Floor
For Item No.22 For Admin Building 2nd Floor
For Item No.22 For Residential Building 2nd Floor
For Item No.22 For Admin Building 3rd Floor
For Item No.22 For Residential Building 3rd Floor
For Item No.22 For Residential Building 4th Floor
ITEM No23: Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks compacting, curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.) Spec. No: Bd.F.9 Page No 303 and B.7, Page No38 D.S.R.I.No I.No 26.07 BDF 9 Page No 184 Admin Building Ground Floor
For Item No.23 For Residential Building Ground Floor
For Item No.23 For Admin Building 1st Floor
For Item No.23 For Residential Building 1st Floor
For Item No.23 For Admin Building 2nd Floor
For Item No.23 For Residential Building 2nd Floor
For Item No.23 For Admin Building 3rd Floor
For Item No.23 For Residential Building 3rd Floor
For Item No.23 For Residential Building 4th Floor
ITEM No24: Providing and laying Cast in situ/Ready Mix cement concrete in M-35 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.) Spec. No: Bd.F.11 Page No 304 and B.7, Page No 38 D.S.R. I.No 26.19 BDF 11 Page No 185 Admin Building Basement Floor-1
For Item No.24 For Residential Building Basement Floor-1
For Item No.24 For Admin Building Basement Floor-2
For Item No.24 For Residential Building Basement Floor-2
For Item No.24 For Admin Building Ground Floor
For Item No.24 For Residential Building Ground Floor
For Item No.24 For Admin Building 1st Floor
For Item No.24 For Residential Building 1st Floor
For Item No.24 For Admin Building 2nd Floor
For Item No.24 For Residential Building 2nd Floor
For Item No.24 For Admin Building 3rd Floor
For Item No.24 For Residential Building 3rd Floor
For Item No.24 For Residential Building 4th Floor
ITEM No25: Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. Coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting, curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed Sand V.S.I. Grade finely washed etc.). Spec. No: Bd. F. 12 Page No 304 & B-7, Pg 38 D.S.R. I.No 26.23 BDF 12 Page No 185 Admin Building Basement Floor-1
For Item No.25 Ground Floor
For Item No.25 1st Floor
For Item No.25 2nd Floor
For Item No.25 3rd Floor
For Item No.25 For Residential Building 4th Floor
ITEM No26: Providing and casting in situ or precast tapering R.C.C. M-20 Semi Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant Spec : MORTH 409 D.S.R. I.No 7.02 MORTH 409 Page No 69 For Residential Building
ITEM No27: Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No: Bd.F.17, Page No 306 D.S.R. I.No 26.33 BDF 17 Page No 188 Admin Building Basement Floor-1
For Item No.27 For Residential Building Basement Floor-1
For Item No.27 For Admin Building Basement Floor-2
For Item No.27 For Residential Building Basement Floor-2
For Item No.27 For Admin Building Ground Floor
For Item No.27 For Residential Building Ground Floor
For Item No.27 For Admin Building 1st Floor
For Item No.27 For Residential Building 1st Floor
For Item No.27 For Admin Building 2nd Floor
For Item No.27 For Residential Building 2nd Floor
For Item No.27 For Admin Building 3rd Floor
For Item No.27 For Residential Building 3rd Floor
For Item No.27 For Residential Building 4th Floor
ITEM No28: Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) Spec. No: Bd.J.2 Page No 355 D.S.R. I.No 31.12 BDJ Page No 206 For Admin Building Basement Floor-2
For Item No.28 For Residential Building Basement Floor-2
ITEM No.29: Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete ) Spec. No.: Bd.J.2 Page No. 355 D.S.R. I.No. 31.12 BDJ Page No. 206 Admin Building Basement Floor-2
For Item No.29 For Residential Building Basement Floor-2
ITEM No30: Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) Spec. No: Bd.J.2 Page No 355 D.S.R. I.No 31.13 BDJ Page No 207 For Admin Building Basement Floor-1
For Item No.30 For Residential Building Basement Floor-1
For Item No.30 Admin Building Basement Floor-2
For Item No.30 For Residential Building Basement Floor-2
ITEM No31: Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete. Spec. No: Bd.A.10 Page No 262 D.S.R. I.No 21.36 BDA 10 Page No 157 Admin Building Basement Floor-1
For Item No.31 For Residential Building Basement Floor-1
For Item No.31 For Admin Basement Floor-2
ITEM No32: Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No: Bd.A.11 Page No 263 D.S.R. I.No 21.37 BDA 11 Page No 157 For Residential Ground Floor
For Item No.32 For Admin Basement Floor-1
For Item No.32 For Admin Basement Floor-2
ITEM No33: Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No: As directed by Engineer in charge. D.S.R. I.No 21.40 BDA Page No 157 For Admin- GSR
For Item No.33 Residentia GSR
ITEM No.34: Providing and laying in situ M-20 cement concrete of trap / granite / quartzite / gneiss metal with 15% plum of trap stones for foundation and bedding of retaining walls and jetty etc. including necessary formwork, compacting, curing, bailing out water manually in tidal range etc. complete. Spec. No.: Spec. No.Bd. E. 5; Page No. 67 / 2012 D.S.R. I.No. 49.26 Bd.E.5 Page No. 326 Admin Building Basement Floor-2
ITEM No35: Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)mm in extra fine jointing mortar of fixoblock of in foundaions and plinth of inner walls/in plinth external walls including bailing out water,striking joints on unexposed faces,racking out joints on exposed faces and watering etc.complete Spec.No:As director by engineer in charge and BDG- 2 and 5 D.S.R. I.No 29.04 BDG Page No 201 Admin Building Ground Floor
For Item No.34 Residential Building Ground Floor
ITEM No36: Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete. Spec. No: Bd.J.2 Page No 355 D.S.R. I.No 31.01 BDJ 2 Page No 205 Admin Building Ground Floor
For Item No.36 Residential Building Ground Floor
ITEM No37: Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)mm in extra fine jointing mortar of fixoblock of in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete Spec.No:As director by engineer incharge and BDG- 2 and 5 D.S.R. I.No 29.05 BDG Page No 201 Admin Building Basement Floor-1
For Item No.37 Rsidential building Basement Floor-1
For Item No.37 For Admin Building Basement Floor-2
For Item No.37 For Residential Building Basement Floor-2
For Item No.37 For Admin Building Ground Floor
For Item No.37 For Residential Building Ground Floor
For Item No.37 For Admin Building 1st Floor
For Item No.37 For Residential Building 1st Floor
For Item No.37 For Admin Building 2nd Floor
For Item No.37 For Residential Building 2nd Floor
For Item No.37 For Admin Building 3rd Floor
For Item No.37 For Residential Building 3rd Floor
For Item No.37 For Residential Building 4th Floor
ITEM No38: Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625x 240x100)mm in extra fine jointing mortar of fixoblock of in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out joints and watering compete Spec.No:Bd.G.7 Page No316. D.S.R. I.No 29.06 BDG 7 Page No 201 For Residential Building Ground Floor
For Item No.38 For Admin Building 1st Floor
For Item No.38 For Admin Building 2nd Floor
For Item No.38 For Admin Building 3rd Floor
For Item No.39 For Admin Building 2nd Floor
For Item No.39 For Admin Building 3rd Floor
ITEM No40: Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec : As directed by Engineer In Charge. D.S.R. I.No 33.68 BDM Page No 220 For Admin Building Basement Floor-1
For Item No.40 For Admin Building Basement Floor-2
For Item No.40 For Admin Building Ground Floor
For Item No.40 For Residential Building Ground Floor
For Item No.40 For Admin Building 1st Floor
For Item No.40 For Residential Building 1st Floor
For Item No.40 For Admin Building 2nd Floor
For Item No.40 For Residential Building 2nd Floor
For Item No.40 For Admin Building 3rd Floor
For Item No.40 For Residential Building 3rd Floor
For Item No.40 For Residential Building 4th Floor
ITEM No41: Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Spec : As directed by Engineer In Charge. D.S.R. I.No 39.01 Page No 245 For Admin Building Ground Floor
For Item No.41 For Admin Building 1st Floor
For Item No.41 For Residential Building 1st Floor
For Item No.41 For Admin Building 2nd Floor
For Item No.41 For Residential Building 2nd Floor
For Item No.41 For Admin Building 3rd Floor
For Item No.41 For Residential Building 3rd Floor
For Item No.41 For Residential Building 4th Floor
ITEM No.42: Providing and fixing frame with / without ventilator of size as specified with Country non teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec : As directed by Engineer In Charge. D.S.R. I.No. 39.02 BDT Page No. 245 For Admin Building Ground Floor
For Item No.42 For Admin Building 1st Floor
For Item No.42 For Admin Building 2nd Floor
For Item No.42 For Admin Building 3rd Floor
ITEM No43: Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete Spec : As directed by Engineer in charge. D.S.R. I.No 39.48 BDT Page No 256 For Admin Building Ground Floor
For Item No.43 For Admin Building 1st Floor
For Item No.43 For Residential Building 1st Floor
For Item No.43 For Admin Building 2nd Floor
For Item No.43 For Residential Building 2nd Floor
For Item No.43 For Admin Building 3rd Floor
For Item No.43 For Residential Building 3rd Floor
For Item No.43 For Residential Building 4th Floor
ITEM No.44: Providing and fixing solid core flush door shutter in double leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Spec : As directed by Engineer in charge. D.S.R. I.No. 39.95 BDT Page No. 263 For Admin Building Ground Floor
For Item No.44 For Admin Building 1st Floor
For Item No.44 For Admin Building 2nd Floor
For Item No.44 For Admin Building 3rd Floor
ITEM No45:Shutter : Supplying & Fixing of 55mm thick asbestos free 'TUFWOOD' brand - 3 criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vacCu.M. pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 kg/Cu.M.) frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128 Kg/Cu.M.), vermaculite mix faced with 3mm Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10mmx4mm affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping. Spec : As directed by Engineer in charge. D.S.R. I.No Non DSR Item For Residential Building Basement Floor-1
For Item No.45 For Residential Building Basement Floor-2
For Item No.45 For Admin Building Ground Floor
For Item No.45 For Residential Building Ground Floor
For Item No.45 For Admin Building 1st Floor
For Item No.45 For Residential Building 1st Floor
For Item No.45 For Admin Building 2nd Floor
For Item No.45 For Residential Building 2nd Floor
For Item No.45 For Admin Building 3rd Floor
For Item No.45 For Residential Building 3rd Floor
For Item No.45 For Residential Building 4th Floor
ITEM No46: Door Frame: Providing & Fixing Frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS: 401 and kiln seasoned to moisture below 15% as per IS:1141 of section 120X70mm spray quoted with 2 coats of In tumescent paint of minimum 200micron, with 1 row of Brush-Type Astroflame ® intumescents trip (imported) of size 10mm x4mm concealed in the groove of the Frame for fire and smoke sealing, etc. complete as per direction of Engineer in Charge. Spec : As directed by Engineer In Charge. D.S.R. I.No 51.172 Page No 400 For Residential Building Basement Floor-1
For Item No.46 For Residential Building Basement Floor-2
For Item No.46 For Admin Building Ground Floor
For Item No.46 For Residential Building Ground Floor
For Item No.46 For Admin Building 1st Floor
For Item No.46 For Residential Building 1st Floor
For Item No.46 For Admin Building 2nd Floor
For Item No.46 For Residential Building 2nd Floor
For Item No.46 For Admin Building 3rd Floor
For Item No.46 For Residential Building 3rd Floor
For Item No.46 For Residential Building 4th Floor
ITEM No.47: Providing and fixing 30mm thick SOLID PANEL PVC INTERNAL DOOR SHUTTER consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for stiles ,top, lock and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat molded PVC channel of size 30 x 100mm forming stiles, and 5mm thick, 125mm wide PVC sheets for top rail, lock rail and bottom rail on either side, and 15mm (5mm x 3) thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 10 mm thick prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent cement adhesive. including stainless steel fixtures and fastening Complete as per direction of Engineer in charge, manufacturer's specification and drawing. Spec : As directed by Engineer in charge. D.S.R. I.No. 39.81 BDT Page No. 261 For Admin Building 1st Floor
For Item No.47 For Admin Building 2nd Floor
For Item No.47 For Admin Building 3rd Floor
ITEM No.48: Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm, 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick, vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc. complete Spec : As directed by Engineer in charge. D.S.R. I.No. 39.65 BDT Page No. 259 For Admin Building 1st Floor
For Item No.48 For Admin Building 2nd Floor
For Item No.48 For Admin Building 3rd Floor
ITEM No.49: Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kg/Smt. Spec : Bd.W.6 Page No.585. D.S.R. I.No. 44.10 BDW 6 Page No. 294 For Admin Building Basement Floor-1
For Item No.49 For Admin Building Basement Floor-2
For Item No.49 For Admin Building Ground Floor
ITEM No50: Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/Sq.M as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Spec : Bd.U.1 Page No 537. D.S.R. I.No 40.01 BDU1 Page No 264 For Admin Building Basement Floor-1
For Item No.50 For Admin Building Ground Floor
For Item No.50 For Residential Building Ground Floor
For Item No.50 For Admin Building 1st Floor
For Item No.50 For Residential Building 1st Floor
For Item No.50 For Admin Building 2nd Floor
For Item No.50 For Residential Building 2nd Floor
For Item No.50 For Admin Building 3rd Floor
For Item No.50 For Residential Building 3rd Floor
For Item No.50 For Residential Building 4th Floor
ITEM No51: Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising without box Spec : As directed by Engineer In Charge. D.S.R. I.No 39.42 Page No 253 For Residential Building- 1st Floor
For Item No.51 For Residential Building 2nd Floor
For Item No.51 For Residential Building 3rd Floor
For Item No.51 For Residential Building 4th Floor
ITEM No.52: Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box Spec : As directed by Engineer In Charge. D.S.R. I.No. 39.43 Page No. 254 For Admin Building Ground Floor
For Item No.52 For Admin Building 1st Floor
For Item No.52 For Admin Building 2nd Floor
For Item No.52 For Admin Building 3rd Floor
ITEM No.53: Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box Spec : As directed by Engineer In Charge. D.S.R. I.No. 39.39 Page No. 252 For Admin Building Ground Floor
For Item No.53 For Admin Building 1st Floor
For Item No.53 For Admin Building 2nd Floor
For Item No.53 For Admin Building 3rd Floor
ITEM No.54: Providing and fixing of factory made uPVC Sliding window & door complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2mm), duly reinforced with G.I. section 1.5mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1. Tensile Impact Strength ISO 8256-more than 700Kj /m2 2. Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5mm Float Annealed glass in the sash, uPVC glazing bead, inter lock, EPDM/ TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window/ Door will be fixed to the wall with 100mm long and 8mm dia. Admin Building Ground Floor
Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Windowand Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.. c) Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm. Spec : As directed by Engineer In Charge. D.S.R. I.No. 54.08 Page No. 516 For Admin Building 1st Floor
For Item No.54 For Admin Building 2nd Floor
For Item No.54 For Admin Building 3rd Floor
ITEM No55: Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete. Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered. Spec : As directed by Engineer In Charge. b) Powder Coated D.S.R. I.No 39.52b Page No 256 For Residential Building Ground Floor
For Item No.55 For Residential Building 1st Floor
For Item No.55 For Residential Building 2nd Floor
For Item No.55 For Residential Building 3rd Floor
For Item No.55 For Residential Building 4th Floor
ITEM No56: Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Spec : As directed by Engineer In Charge. D.S.R. I.No 39.68 Page No 259 For Admin Building 1st Floor
For Item No.56 For Residential Building 1st Floor
For Item No.56 For Admin Building 2nd Floor
For Item No.56 For Residential Building 2nd Floor
For Item No.56 For Admin Building 3rd Floor
For Item No.56 For Residential Building 3rd Floor
For Item No.56 For Residential Building 4th Floor
ITEM No57: Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec. No: As directed by Engineer in Charge. D.S.R. I.No 32.26 BDL Page No 210 For Admin Building Basement Floor-1
For Item No.57 For Residential Building Basement Floor-1
For Item No.57 For Admin Building Basement Floor-2
For Item No.57 For Residential Building Basement Floor-2
For Item No.57 For Admin Building Ground Floor
For Item No.57 For Residential Building Ground Floor
For Item No.57 For Admin Building 1st Floor
For Item No.57 For Residential Building 1st Floor
For Item No.57 For Admin Building 2nd Floor
For Item No.57 For Residential Building 2nd Floor
For Item No.57 For Admin Building 3rd Floor
For Item No.57 For Residential Building 3rd Floor
For Item No.57 For Residential Building 4th Floor
ITEM No58: Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Spec.No : As directed by Engineer in charge D.S.R.I.No 32.34 BDL Page No 212 For Admin Building Basement Floor-1
For Item No.58 For Residential Building Basement Floor-1
For Item No.58 For Admin Building Basement Floor-2
For Item No.58 For Residential Building Basement Floor-2
For Item No.58 For Admin Building Ground Floor
For Item No.58 For Residential Building Ground Floor
For Item No.58 For Admin Building 1st Floor
For Item No.58 For Residential Building 1st Floor
For Item No.58 For Admin Building 2nd Floor
For Item No.58 For Residential Building 2nd Floor
For Item No.58 For Admin Building 3rd Floor
For Item No.58 For Residential Building 3rd Floor
For Item No.58 For Residential Building 4th Floor
ITEM No59: Providing and applying gypsum plaster ( with Gypsum material of Gypsum India / Mega Sign or equivalent make ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc. complete. Spec.No : As directed by Engineer in charge D.S.R.I.No 32.31 BDL Page No 211 For Residential Building Basement Floor-1
For Item No.59 For Residential Building Basement Floor-2
For Item No.59 For Residential Building Ground Floor
For Item No.59 For Admin Building 1st Floor
For Item No.59 For Residential Building 1st Floor
For Item No.59 For Admin Building 2nd Floor
For Item No.59 For Residential Building 2nd Floor
For Item No.59 For Admin Building 3rd Floor
For Item No.59 For Residential Building 3rd Floor
For Item No.59 For Residential Building 4th Floor
ITEM No60: Providing internal cement plaster 20mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Spec. No: Bd.L.4 Page No 368 D.S.R. I.No 32.07 BDL 4A Page No 209 For Admin Building Basement Floor-1
For Item No.60 For Residential Building Basement Floor-1
For Item No.60 For Admin Building Basement Floor-2
For Item No.60 For Residential Building Basement Floor-2
For Item No.60 For Admin Building Ground Floor
For Item No.60 For Residential Building Ground Floor
For Item No.60 For Residential Building 1st Floor
For Item No.60 For Residential Building 2nd Floor
For Item No.60 For Residential Building 3rd Floor
For Item No.60 For Residential Building 4th Floor
ITEM No61: Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Spec. No: Bd.L.4 Page No 368 D.S.R. I.No 32.04 BDL 2A Page No 209 For Residential Building Basement Floor-1
For Item No.61 For Residential Building Basement Floor-2
For Item No.61 For Residential Building Ground Floor
For Item No.61 For Admin Building 1st Floor
For Item No.61 For Residential Building 1st Floor
For Item No.61 For Admin Building 2nd Floor
For Item No.61 For Residential Building 2nd Floor
For Item No.61 For Admin Building 3rd Floor
For Item No.61 For Residential Building 3rd Floor
For Item No.61 For Residential Building 4th Floor
ITEM No62: Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. Spec. No: Bd. L.10, Page No370 D.S.R. I.No 32.15 BDL 10 Page No 210 For Admin Building Ground Floor
For Item No.62 For Residential Building Ground Floor
For Item No.62 For Residential Building 1st Floor
For Item No.62 For Residential Building 2nd Floor
For Item No.62 For Residential Building 3rd Floor
For Item No.62 For Residential Building 4th Floor
ITEM No63: Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Spec. No: As directed by Engineer in charge. D.S.R. I.No 32.21 BDL Page No 210 For Admin Building Basement Floor-1
For Item No.63 For Residential Building Basement Floor-1
For Item No.63 For Admin Building Basement Floor-2
For Item No.63 For Residential Building Basement Floor-2
ITEM No64: Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec. No: Bd.L.7 Page No 369 D.S.R. I.No 32.11 BDL 7 Page No 209 For Admin Building Ground Floor
For Item No.64 For Residential Building Ground Floor
For Item No.64 For Admin Building 1st Floor
For Item No.64 For Residential Building 1st Floor
For Item No.64 For Admin Building 2nd Floor
For Item No.64 For Residential Building 2nd Floor
For Item No.64 For Admin Building 3rd Floor
For Item No.64 For Residential Building 3rd Floor
For Item No.64 For Residential Building 4th Floor
ITEM No65: Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. Spec. No: As directed by Engineer in charge D.S.R. I.No 32.32 BD Page No 211 For Admin Building Ground Floor
For Item No.65 For Admin Building 1st Floor
For Item No.65 For Residential Building 1st Floor
For Item No.65 For Admin Building 2nd Floor
For Item No.65 For Residential Building 2nd Floor
For Item No.65 For Admin Building 3rd Floor
For Item No.65 For Residential Building 3rd Floor
For Item No.65 For Residential Building 4th Floor
ITEM No66: Providing internal cement plaster 20mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Spec. No: Bd.L.4 Page No 368 D.S.R. I.No 32.08 BDL 4B Page No 209 For Residential Building 3rd Floor
ITEM No67: Providing internal cement plaster 20mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Spec. No: Bd.L.4 Page No 368 D.S.R. I.No 32.08 BDL 4B Page No 209 For Admin Building GSR
For Item No.67 For Residential Building GSR
ITEM No68: Providing and applying a base coat comprising of 1KilogramPolydee-MC and 1Kilogramfresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete Spec. No: As directed by Engineer in charge. D.S.R. I.No 31.11 BDJ Page No 206 For Residential Building 3rd Floor
ITEM No.69: Providing and applying a base coat comprising of 1KilogramPolydee-MC and 1Kilogramfresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete Spec. No.: As directed by Engineer in charge. D.S.R. I.No. 31.11 BDJ Page No. 206 For Residential Building GSR
ITEM No70: Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Spec. No: As directed by Engineer in charge. D.S.R. I.No 31.05 BDJ Page No 205 For Admin Building 1st Floor
For Item No.70 For Residential Building 1st Floor
For Item No.70 For Admin Building 2nd Floor
For Item No.70 For Residential Building 2nd Floor
For Item No.70 For Admin Building 3rd Floor
For Item No.70 For Residential Building 3rd Floor
For Item No.70 For Residential Building 4th Floor
ITEM No71: Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Spec. No: As directed by Engineer in charge. D.S.R. I.No 31.26 BDJ Page No 208 For Admin Building 1st Floor
For Item No.71 For Residential Building 1st Floor
For Item No.71 For Admin Building 2nd Floor
For Item No.71 For Residential Building 2nd Floor
For Item No.71 For Admin Building 3rd Floor
For Item No.71 For Residential Building 3rd Floor
For Item No.71 For Residential Building 4th Floor
ITEM No72: Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. Spec. No: As directed by Engineer in charge. D.S.R. I.No 33.30 BDM Page No 216 For Admin Building Basement Floor-1
For Item No.72 For Residential Building Basement Floor-1
For Item No.72 For Admin Building Basement Floor-2
For Item No.72 For Residential Building Basement Floor-2
For Item No.72 For Residential Building Ground Floor
ITEM No73: Providing and laying cement concrete wearing coat M30 grade with batch mix type / concrete mixer with SCADA including reinforcement as per drawings and technical specifications etc. complete with fine agreegates of required specifications ( VSI sand finely washed etc ) Spec. No: MORT and H ? 2700 D.S.R. I.No 14.86 MORTH Page No 101 For Admin Building Basement Floor-1
For Item No.73 For Residential Building Basement Floor-1
For Item No.73 For Residential Building Basement Floor-2
For Item No.73 For Admin Building Ground Floor
For Item No.73 For Residential Building Ground Floor
ITEM No74: Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Spec. No: Bd. M.22 B/Page No 390 D.S.R. I.No 33.35 BDM 22 Page No 216 For Admin Building Basement Floor-1
For Item No.74 For Residential Building Basement Floor-1
For Item No.74 For Admin Building Basement Floor-2
For Item No.74 For Residential Building Basement Floor-2
For Item No.74 For Admin Building Ground Floor
For Item No.74 For Residential Building Ground Floor
For Item No.74 For Admin Building 1st Floor
For Item No.74 For Residential Building 1st Floor
For Item No.74 For Admin Building 2nd Floor
For Item No.74 For Residential Building 2nd Floor
For Item No.74 For Admin Building 3rd Floor
For Item No.74 For Residential Building 3rd Floor
For Item No.74 For Residential Building 4th Floor
ITEM No75: Providing and laying Polished Kota stone flooring With Hand-Cut Polished Kota Stones 25mm to 30mm thick and required width in plain/diamond pattern on bed of 1:6 Cement mortar including cement float, filling joints with neat cement slurry, curing, cleaning and Mirror Polishing etc. complete Note- Water absorption for kota stone should not exceed 0.05%. (Item to be used with prior permission of Superintending Engineer). Spec. No: Bd.M. 3 B/Page No 380 D.S.R. I.No 33.75 BDM Page No 220 For Admin Building Basement Floor-1
For Item No.75 For Admin Building Ground Floor
For Item No.75 For Admin Building 1st Floor
For Item No.75 For Admin Building 3rd Floor
For Item No.75 For Residential Buildin 4th Floor
ITEM No76: Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. Spec. No: Bd.M.22 Page No 390 D.S.R. I.No 33.81 BDM 22B Page No 221 For Admin Building Basement Floor-1
For Item No.76 For Admin Building Ground Floor
For Item No.76 For Admin Building 1st Floor
For Item No.76 For Admin Building 3rd Floor
For Item No.76 For Residential Building 4th Floor
ITEM No77: Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Spec. Bd. M-12 page No 385 D.S.R. I.No 33.42 BDM 12 Page No 217 For Residential Building Basement Floor-1
For Item No.77 For Residential Building Ground Floor
For Item No.77 For Admin Building 1st Floor
For Item No.77 For Residential Building 1st Floor
For Item No.77 For Admin Building 2nd Floor
For Item No.77 For Residential Building 2nd Floor
For Item No.77 For Admin Building 3rd Floor
For Item No.77 For Residential Building 3rd Floor
For Item No.77 For Residential Building 4th Floor
ITEM No78: Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete Spec. No: Bd.M.12 Page No 385 D.S.R. I.No 33.43 BDM 12 Page No 217 For Residential Building Basement Floor-1
For Item No.78 For Residential Building Basement Floor-2
For Item No.78 For Residential Building Ground Floor
For Item No.78 For Admin Building 1st Floor
For Item No.78 For Residential Building 1st Floor
For Item No.78 For Admin Building 2nd Floor
For Item No.78 For Residential Building 2nd Floor
For Item No.78 For Admin Building 3rd Floor
For Item No.78 For Residential Building 3rd Floor
For Item No.78 For Residential Building 4th Floor
ITEM No.79: Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. D.S.R. I.No. 33.44 BDM 12 Page No. 217 For Admin Building Basement Floor-1
For Item No.79 For Admin Building Basement Floor-2
For Item No.79 For Admin Building Ground Floor
For Item No.79 For Admin Building 1st Floor
For Item No.79 For Admin Building 2nd Floor
For Item No.79 For Admin Building 3rd Floor
ITEM No.80: Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. Spec. No.: Bd.M.12 Page No. 385 D.S.R. I.No. 33.47 BDM 12 Page No. 218 For Admin Building Basement Floor-1
For Item No.80 For Admin Building Basement Floor-2
For Item No.80 For Admin Building Ground Floor
For Item No.80 For Admin Building 1st Floor
For Item No.80 For Admin Building 2nd Floor
For Item No.80 For Admin Building 3rd Floor
ITEM No.81: Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Spec. No.: Bd.M. 3 B/Page No. 380 D.S.R. I.No. 33.34 BDM 3 Page No. 216 For Admin Building Ground Floor
For Item No.81 For Admin Building 1st Floor
For Item No.81 For Admin Building 2nd Floor
For Item No.81 For Admin Building 3rd Floor
ITEM No82: Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. Spec. Bd.M.12 Page No 385. D.S.R. I.No 33.24 BDM 12 Page No 215 For Admin Building 1st Floor
For Item No.82 For Residential Building 1st Floor
For Item No.82 For Admin Building 2nd Floor
For Item No.82 For Residential Building 2nd Floor
For Item No.82 For Admin Building 3rd Floor
For Item No.82 For Residential Building 3rd Floor
For Item No.82 For Residential Building 4th Floor
ITEM No83: Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Spec. Bd.M.12 Page No 385. D.S.R. I.No 33.26 BDM 12 Page No 215 For Residential Building 1st Floor
For Item No.83 For Residential Building 2nd Floor
For Item No.83 For Residential Building 3rd Floor
For Item No.83 For Residential Building 4th Floor
ITEM No84: Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) Spec : As directed by Engineer In Charge D.S.R. I.No 41.78 BDV Page No 273 For Admin Building 1st Floor
For Item No.84 For Residential Building 1st Floor
For Item No.84 For Admin Building 2nd Floor
For Item No.84 For Residential Building 2nd Floor
For Item No.84 For Admin Building 3rd Floor
For Item No.84 For Residential Building 3rd Floor
For Item No.84 For Residential Building 4th Floor
ITEM No85: Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 kg/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand). Spec. No: A directed by Engineer in charge D.S.R. I.No 33.54 BDM Page No 219 For Residential Building
ITEM No86: Directional signage Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6" x 9" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the engineer in charge. Spec : As directed by Engineer In Charge D.S.R. I.No 51.67 Page No 370 For Admin Building Basement Floor-1
For Item No.86 For Residential Building Basement Floor-1
For Item No.86 For Admin Building Basement Basement Floor-2
For Item No.86 For Residential Building Basement Floor-2
For Item No.86 For Admin Building Ground Floor
For Item No.86 For Residential Building Ground Floor
For Item No.86 For Admin Building 1st Floor
For Item No.86 For Admin Building 2nd Floor
For Item No.86 For Admin Building 3rd Floor
ITEM No87: Providing and laying in trenches 50 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 6.33 kg/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No: Bd.V.5 Page No 551 D.S.R. I.No 43.14 BDV 5 Page No 288 For Residential Building Ground Floor
ITEM No88: Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kg/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in Police Mukhalaya premises or as directed etc. complete. Spec. No: Bd.V.5 Page No 551 D.S.R. I.No 41.15 BDV 5 Page No 267 For Residential Building Ground Floor
ITEM No89: Providing and fixing 50mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber] Spec. No: Bd.V.7 Page No 554 D.S.R. I.No 41.30 BDV 7 Page No 269 For Residential Building Ground Floor
ITEM No.90: Providing and fixing 75mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber] Spec. No.: Bd.V.7 Page No. 554 D.S.R. I.No. 41.31 BDV 7 Page No. 269 For Admin Building Ground Floor
For Item No.90 For Residential Building Ground Floor
ITEM No.91: Providing and fixing on walls /ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Police Mukhalaya premises or as directed etc. complete. Spec. No.: BD.V 5 page 551 and as directed by Engineer in charge D.S.R. I.No. 42.60 BDV 5 Page No. 280 For Admin Building 1st Floor
For Admin Building 2nd Floor
For Admin Building 3rd Floor
ITEM No92: Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Police Mukhalaya premises or as directed etc. complete. Spec. No: BD.V 5 page 551 and as directed by Engineer in charge D.S.R. I.No 42.59 BDV 5 Page No 280 For Residential Building Ground Floor
For Item No.92 For Admin Building 1st Floor
For Item No.92 For Residential Building 1st Floor
For Item No.92 For Admin Building 2nd Floor
For Item No.92 For Residential Building 2nd Floor
For Item No.92 For Admin Building 3rd Floor
For Item No.92 For Residential Building 3rd Floor
For Item No.92 For Residential Building 4th Floor
ITEM No93: Providing and fixing on walls /ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Police Mukhalaya premises or as directed etc. complete. pec. No: BD.V 5 page 551 and as directed by Engineer in charge D.S.R. I.No 42.57 BDV 5 Page No 280 For Admin Building 1st Floor
For Item No.93 For Residential Building 1st Floor
For Item No.93 For Admin Building 2nd Floor
For Item No.93 For Residential Building 2nd Floor
For Item No.93 For Admin Building 3rd Floor
For Item No.93 For Residential Building 3rd Floor
For Item No.93 For Residential Building 4th Floor
ITEM No94: Providing and fixing on walls /ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Police Mukhalaya premises or as directed etc. complete. pec. No: BD.V 5 page 551 and as directed by Engineer in charge D.S.R. I.No 42.55 BDV Page No 280 For Admin Building 1st Floor
For Item No.94 For Residential Building 1st Floor
For Item No.94 For Admin Building 2nd Floor
For Item No.94 For Residential Building 2nd Floor
For Item No.94 For Admin Building 3rd Floor
For Item No.94 For Residential Building 3rd Floor
For Item No.94 For Residential Building 4th Floor
ITEM No95: Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Spec. No: As directed by Engineer in charge D.S.R. I.No 48.28 BDV Page No 314 For Admin Building 1st Floor
For Item No.95 For Residential Building 1st Floor
For Item No.95 For Admin Building 2nd Floor
For Item No.95 For Residential Building 2nd Floor
For Item No.95 For Admin Building 3rd Floor
For Item No.95 For Residential Building 3rd Floor
For Item No.95 For Residential Building 4th Floor
ITEM No96: Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout jaquar or equivalent make continental (CAT.No CON -359) including necessary sockets/ union nut etc. complete."(Jaquar Make Continental) Spec. No: As directed by Engineer in charge D.S.R. I.No 42.84 BDV Page No 283 For Admin Building 1st Floor
For Item No.96 For Residential Building 1st Floor
For Item No.96 For Admin Building 2nd Floor
For Item No.96 For Residential Building 2nd Floor
For Item No.96 For Admin Building 3rd Floor
For Item No.96 For Residential Building 3rd Floor
For Item No.96 For Residential Building 4th Floor
ITEM No97: Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange jaquar or equivalent ?make continental (CAT.No CON-273 UPR) including necessary sockets/union nut etc. complete.(Jaquar Make Continental) Spec. No: As directed by Engineer in charge D.S.R. I.No 42.81 BDV Page No 282 For Admin Building 1st Floor
For Item No.97 For Residential Building 1st Floor
For Item No.97 For Admin Building 2nd Floor
For Item No.97 For Residential Building 2nd Floor
For Item No.97 For Admin Building 3rd Floor
For Item No.97 For Residential Building 3rd Floor
For Item No.97 For Residential Building 4th Floor
ITEM No.98: Providing and fixing screw down for 80 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. (Jaquar Make Continental) Spec. No.: Bd.V.9 Page No. 555 D.S.R. I.No. 41.50 BDV 9 Page No. 270 For Admin Building Ground Floor
For Item No.98 For Admin Building 3rd Floor
ITEM No99: Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.(Jaquar Make Continental) Spec. No: Bd.V.9 Page No 555 D.S.R. I.No 41.47 BDV 9 Page No 270 For Residential Building 1st Floor
For Item No.99 For Residential Building 2nd Floor
For Item No.99 For Residential Building 3rd Floor
For Item No.99 For Residential Building 4th Floor
ITEM No.100: Providing and fixing screw down for 65mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. (Jaquar Make Continental) Spec. No.: Bd.V.9 Page No. 555 D.S.R. I.No. 41.48 BDV 9 Page No. 270 For Admin Building 1st Floor
For Item No.100 For Admin Building 2nd Floor
For Item No.100 For Admin Building 3rd Floor
ITEM No101: Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.(Jaquar Make Continental) Spec. No: Bd.V.9 Page No 555 D.S.R. I.No 41.45 BDV 9 Page No 270 For Admin Building 1st Floor
For Item No.101 For Residential Building 1st Floor
For Item No.101 For Admin Building 2nd Floor
For Item No.101 For Residential Building 2nd Floor
For Item No.101 For Admin Building 3rd Floor
For Item No.101 For Residential Building 3rd Floor
For Item No.101 For Residential Building 4th Floor
ITEM No102: Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete.(Jaquar Make Continental) Spec : As directed by Engineer In Charge D.S.R. I.No 42.32 BDV Page No 277 For Admin Building 1st Floor
For Item No.102 For Residential Building 1st Floor
For Item No.102 For Admin Building 2nd Floor
For Item No.102 For Residential Building 2nd Floor
For Item No.102 For Admin Building 3rd Floor
For Item No.102 For Residential Building 3rd Floor
For Item No.102 For Residential Building 4th Floor
ITEM No103: Providing and fixing chromium plated towal rod 16 mm dia and 75 cm. in length including all accessories complete. Spec : As directed by Engineer In Charge D.S.R. I.No 42.31 BDV Page No 277 For Admin Building 1st Floor
For Item No.103 For Residential Building 1st Floor
For Item No.103 For Admin Building 2nd Floor
For Item No.103 For Residential Building 2nd Floor
For Item No.103 For Admin Building 3rd Floor
For Item No.103 For Residential Building 3rd Floor
For Item No.103 For Residential Building 4th Floor
ITEM No104: Providing and fixing C.P.Handshower (health faucet) 1m.PVC tube with wall hook jaquarmake (Cat. No ALD 563 ) Spec : As directed by Engineer In Charge D.S.R. I.No Sr,234 Page No 536 For Residential Building 1st Floor
For Item No.104 For Residential Building 2nd Floor
For Item No.104 For Residential Building 3rd Floor
For Item No.104 For Residential Building 4th Floor
ITEM No105: Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete D.S.R. I.No 42.20 BDV Page No 276 For Admin Building 1st Floor
For Item No.105 For Residential Building 1st Floor
For Item No.105 For Admin Building 2nd Floor
For Item No.105 For Residential Building 2nd Floor
For Item No.105 For Admin Building 3rd Floor
For Item No.105 For Residential Building 3rd Floor
For Item No.105 For Residential Building 4th Floor
ITEM No106: Providing and fixing 10 cm PVC nahani trap with grating etc. complete. Spec. No: BD.V 32 A page 551 and as directed by Engineer in charge D.S.R. I.No 42.67 BDV 32 Page No 281 For Admin Building 1st Floor
For Item No.106 For Residential Building 1st Floor
For Item No.106 For Admin Building 2nd Floor
For Item No.106 For Residential Building 2nd Floor
For Item No.106 For Admin Building 3rd Floor
For Item No.106 For Residential Building 3rd Floor
For Item No.106 For Residential Building 4th Floor
Item No 107 : Providing and fixing European type Colour glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 liter enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps, 20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) Spec. No: As directed by Engineer in charge D.S.R. I.No 43.21 BDV 22 Page No 289 For Admin Building 1st Floor
For Item No.107 For Residential Building 1st Floor
For Item No.107 For Admin Building 2nd Floor
For Item No.107 For Residential Building 2nd Floor
For Item No.107 For Admin Building 3rd Floor
For Item No.107 For Residential Building 3rd Floor
For Item No.107 For Residential Building 4th Floor
ITEM No. 108: Providing and fixing 1st class Colour glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:10) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. (Jaquar Make Continental) Spec : As directed by Engineer In Charge D.S.R. I.No. 42.33 BDV Page No. 277 For Admin Building 1st Floor
For Item No.108 For Admin Building 2nd Floor
For Item No.108 For Admin Building 3rd Floor
ITEM No. 109: PProviding and fixing coloured glazed earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap brackets for fixing the cistern 32mm dia. P.V.C. flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection up to the outside face of the wall. (Jaquar Make Continental) Spec. No.: Bd.V.23 Page No. 562 D.S.R. I.No. 41.59 BDV 23 Page No. 271 For Admin Building 1st Floor
For Item No.109 For Admin Building 2nd Floor
For Item No.109 For Admin Building 3rd Floor
ITEM No 110: Providing and fixing coloured glazed earthenware Wash Hand Basin of 55cm x 40 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. Spec. No: Bd.V.30 Page No 565 D.S.R. I.No 41.66 BDV 30 Page No 272 For Admin Building 1st Floor
For Item No.110 For Residential Building 1st Floor
For Item No.110 For Admin Building 2nd Floor
For Item No.110 For Residential Building 2nd Floor
For Item No.110 For Admin Building 3rd Floor
For Item No.110 For Residential Building 3rd Floor
For Item No.110 For Residential Building 4th Floor
ITEM No.111: Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. (Jaquar Make Continental) Spec. No.: As directed by Engineer in charge D.S.R. I.No. 42.78 BDV 4 Page No. 282 For Admin Building 1st Floor
For Item No.111 For Admin Building 2nd Floor
For Item No.111 For Admin Building 3rd Floor
ITEM No 112: Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No: Bd.V.38, Page No 572 D.S.R. I.No 42.02 BDV 38 Page No 274 For Admin Building Ground Floor
For Item No.112 For Residential Building Ground Floor
ITEM No113: Providing & constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete etc. complete with R.C.C. Cover. Spec. No: Bd.V.43, Page No 574 D.S.R. I.No 42.12 BDV 43 Page No 275 For Admin Building Basement Floor-2
For Item No.113 For Admin Building Ground Floor
For Item No.113 For Residential Building Ground Floor
ITEM No114: Providing & constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover. Spec. No: Bd.V.43, Page No 574 D.S.R. I.No 42.13 BDV 43 Page No 275 For Admin Building Ground Floor
For Item No.114 For Residential Building Ground Floor
ITEM No115: Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stoneware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover. Spec. No: Bd.V.44, Page No 575 D.S.R. I.No 42.15 BDV 44 Page No 275 Admin Building Ground Floor
For Item No.115 For Residential Building Ground Floor
ITEM No116: Providing and constructing Ductile Iron circular manhole 45 cm dia. At top 90 cm at bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15 cm thick burnt brick mansonry with 1:1 cement mortar plaster 25 mm thick inside and outside 20 mm (1:3) ductile iron heavy type cover with ring 125 kg in weight. High strength. More life and Durability, Good Antiskid Grip, Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer Spec. No: As directed by Engineer-incharge D.S.R. I.No 50.31 BDV Page No 337 Admin Building Ground Floor
For Item No.116 For Residential Building Ground Floor
For Item No.117 Admin Building Basement Floor-2
For Item No.118 For Residential Building Ground Floor
For Item No.119 For Residential Building Ground Floor
For Item No.120 For Residential Building Ground Floor
For Item No.122 For Residential Building Ground Floor
ITEM No122: Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface Spec. No: As directed by Engineer in charge D.S.R. Item No 26.68 BDF Page No 196 Admin Building Ground Floor
For Item No.122 Admin Building 1st Floor
For Item No.123 Residential Building 1st Floor
For Item No.123 Admin Building 2nd Floor
For Item No.123 Residential Building 2nd Floor
For Item No.123 Admin Building 3rd Floor
For Item No.123 Residential Building 3rd Floor
For Item No.123 Residential Building 4th Floor
ITEM No123: Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete (Low VOC). Spec : As directed by Engineer In Charge D.S.R. I.No 48.15 Page No 312 Admin Building Basement Floor-1
For Item No.123 Residential Building Basement Floor-1
For Item No.123 For Admin Building Basement Floor-2
For Item No.123 For Residential Building Basement Floor-2
For Item No.123 For Admin Building Ground Floor
For Item No.123 For Residential Building Ground Floor
For Item No.123 For Admin Building 1st Floor
For Item No.123 For Residential Building 1st Floor
For Item No.123 For Admin Building 2nd Floor
For Item No.123 For Residential Building 2nd Floor
For Item No.123 For Admin Building 3rd Floor
For Item No.123 For Residential Building 3rd Floor
For Item No.123 For Residential Building 4th Floor
ITEM No124: Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary Spec : As directed by Engineer In Charge D.S.R. I.No 35.26 Page No 225 Residential Building Basement Floor-1
For Item No.124 Residential Building Basement Floor-2
For Item No.124 For Admin Building Ground Floor
For Item No.124 For Residential Building Ground Floor
For Item No.124 For Admin Building 1st Floor
For Item No.124 For Residential Building 1st Floor
For Item No.124 For Admin Building 2nd Floor
For Item No.124 For Residential Building 2nd Floor
For Item No.124 For Admin Building 3rd Floor
For Item No.124 For Residential Building 3rd Floor
For Item No.124 For Residential Building 4th Floor
ITEM No125: Providing and Fixing 900mm high mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) Spec : As directed by Engineer Incharge D.S.R. I.No 40.08 BDW Page No 265 For Admin Building Basement Floor-1
For Item No.125 For Residential Building Basement Floor-1
For Item No.125 For Admin Building Basement Floor-2
For Item No.125 For Residential Building Basement Floor-2
For Item No.125 For Admin Building Ground Floor
For Item No.125 For Residential Building Ground Floor
For Item No.125 For Admin Building 1st Floor
For Item No.125 For Residential Building 1st Floor
For Item No.125 For Admin Building 2nd Floor
For Item No.125 For Residential Building 2nd Floor
For Item No.125 For Admin Building 3rd Floor
For Item No.125 For Residential Building 3rd Floor
For Item No.125 For Residential Building 4th Floor
ITEM No126: Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting, necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete Spec : As directed by Engineer Incharge D.S.R. I.No 40.07 BDW Page No 264 For Admin Building 1st Floor
For Item No.126 For Residential Building 1st Floor
For Item No.126 For Admin Building 2nd Floor
For Item No.126 For Residential Building 2nd Floor
For Item No.126 For Admin Building 3rd Floor
For Item No.126 For Residential Building 3rd Floor
For Item No.126 For Residential Building 4th Floor
ITEM No127: Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete Spec : As directed by Engineer Incharge D.S.R. I.No 40.06 BDW Page No 264 For Admin Building Basement Floor-1
For Item No.127 For Residential Building Basement Floor-1
For Item No.127 Admin Building Basement Floor-2
For Item No.127 For Residential Building Basement Floor-2
For Item No.127 Admin Building Ground Floor
For Item No.127 For Residential Building Ground Floor
For Item No.127 Admin Building 1st Floor
For Item No.127 For Residential Building 1st Floor
For Item No.127 Admin Building 2nd Floor
For Item No.127 Admin Building 3rd Floor
ITEM No128: Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Spec. No: As directed by Engineer in charge. D.S.R. I.No 32.24 BDL Page No 210 For Residential Building Ground Floor
For Item No.128 For Residential Building 1st Floor
For Item No.128 For Residential Building 2nd Floor
For Item No.128 For Residential Building 3rd Floor
For Item No.128 For Residential Building 4th Floor
ITEM No129: Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete. Spec. No: As directed by Engineer in charge. D.S.R. I.No 32.22 BDL Page No 210 Admin Building Ground Floor
For Item No.129 For Residential Building Ground Floor
For Item No.129 For Admin Building 1st Floor
For Item No.129 For Residential Building 1st Floor
For Item No.129 For Admin Building 2nd Floor
For Item No.129 For Residential Building 2nd Floor
For Item No.129 For Admin Building 3rd Floor
For Item No.129 For Residential Building 3rd Floor
For Item No.129 For Residential Building 4th Floor
ITEM No130: Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec : As directed by Engineer In Charge D.S.R. I.No 42.51 BDV Page No 279 Admin Building Ground Floor
For Item No.130 For Residential Building Ground Floor
For Item No.130 For Admin Building 1st Floor
For Item No.130 For Residential Building 1st Floor
For Item No.130 For Admin Building 2nd Floor
For Item No.130 For Residential Building 2nd Floor
For Item No.130 For Admin Building 3rd Floor
For Item No.130 For Residential Building 3rd Floor
For Item No.130 For Residential Building 4th Floor
ITEM No131: Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec : As directed by Engineer In Charge D.S.R. I.No 42.52 BDV Page No 279 Admin Building Ground Floor
For Item No.131 For Residential Building Ground Floor
For Item No.131 For Admin Building 1st Floor
For Item No.131 For Residential Building 1st Floor
For Item No.131 For Admin Building 2nd Floor
For Item No.131 For Residential Building 2nd Floor
For Item No.131 For Admin Building 3rd Floor
For Item No.131 For Residential Building 3rd Floor
For Item No.131 For Residential Building 4th Floor
ITEM No132: Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment) Spec : As directed by Engineer In Charge D.S.R. I.No 42.87 BDV Page No 283 Admin Building Ground Floor
For Item No.132 For Residential Building Ground Floor
For Item No.132 For Admin Building 1st Floor
For Item No.132 For Residential Building 1st Floor
For Item No.132 For Admin Building 2nd Floor
For Item No.132 For Residential Building 2nd Floor
For Item No.132 For Admin Building 3rd Floor
For Item No.132 For Residential Building 3rd Floor
For Item No.132 For Residential Building 4th Floor
ITEM No133: Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Spec. No: Bd.C.2 Page No 275 D.S.R. I.No 23.01 BDC 2 Page No 173 For Residential Building 4th Floor
ITEM No.134: Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete Spec. No.: Bd.C.8 Page No. 278 D.S.R. I.No. 23.04 BDC 8 Page No. 173 For Admin Building 3rd Floor
ITEM No135: Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.. Spec. No: As directed by Engineer in charge. D.S.R. I.No 31.04 BDJ Page No 205 For Admin Building Ground Floor
For Item No.135 For Residential Building Ground Floor
For Item No.135 Admin Building 1st Floor
For Item No.135 Admin Building 2nd Floor
For Item No.135 Admin Building 3rd Floor
For Item No.135 For Residential Building 4th Floor
ITEM No136: Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres Spec : As directed by Engineer In Charge D.S.R. I.No 42.54 BDV Page No 280 Admin Building 3rd Floor
For Item No.136 For Residential Building 4th Floor
ITEM No137: Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 kg) Spec : As directed by Engineer In Charge D.S.R. I.No 42.69 BDV Page No 281 For Residential Building Ground Floor
ITEM No138: Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the works and pumping out water during and after excavation as may be required by using 5.0 to 9.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) D.S.R. I.No 12.23 Admin Building Basement Floor-1
For Item No.138 For Residential Building Basement Floor-1
For Item No.138 Admin Building Basement Floor-2
ITEM No139: Providing and fixing UPVC Roof made up of 3 layers roofing material of thickness 2mm having width of 1130 mm and of required Length having Tensile strength not less than 330 kg/cm2, including fastening with self drilling screw having washers made of stainless steel etc. complete. Spec. No: As directed by Engineer in charge. D.S.R. I.No 38.37 BDR Page No 237 For Residential Building 4th Floor
ITEM No140: Providing Supplying, & fixing in position aluminium fins of 4000x150x100 mm with special locking system designed by Elegance architectural or Equivalent products supported by 50x50mm L-Angle with pre-punchated hole as per approved gap horizontal carriers both, having thickness of 1.2mm and a clear gap of 150mm between vertical members as per pattern, choice of colour, finish, etc. as shown in approved drawing and as instructed by site In charge. Rates shall be inclusive of supply & fixing using 1mm thick L-clit of dim. 50mm X 50mm X 50mm & SS-screws, application of powder coating, cutting, making, fixing, transportation, loading, unloading, lifting, shifting, safety precautions etc. all complete. Spec : As directed by Engineer Incharge Rate As per Approved by PWD Admin Building Ground Floor
For Item No.140 For Residential Building Ground Floor
For Item No.140 For Admin Building 1st Floor
For Item No.140 For Residential Building 1st Floor
For Item No.140 For Admin Building 2nd Floor
For Item No.140 For Residential Building 2nd Floor
For Item No.140 For Admin Building 3rd Floor
For Item No.140 For Residential Building 3rd Floor
For Item No.140 For Residential Building 4th Floor
ITEM No141: Providing and fixing 25mm diameter steel anchor dowel in hard rock including drilling hole of 32 mm diameter up to 0.75 mtrs depth, placing the dowel in position and effectively grouting the hole with CM 1:1 proportion etc. complete. Spec : As directed by Engineer Incharge D.S.R. I.No 12.13 For Residential Building Basement Floor-2
ITEM No141a: Providing and fixing 25mm diameter steel anchor dowel in hard rock including drilling hole of 32 mm diameter up to 0.75 mtrs depth, placing the dowel in position and effectively grouting the hole with CM 1:1 proportion etc. complete. Spec : As directed by Engineer Incharge D.S.R. I.No 12.13 For Admin Building Basement Floor-2
ITEM No142: Smart Care PreapplyHDPE 80for Raft andUncofinedRetaining Wals:-Supplyingandinstallingof Asian Paints or MYK or Sika or equivalent make Smartcare 1.50 m thick pre-applied HDPE fuly bonded membrane or eauivalent make having puncture resistance of 800N as per ASTM E154), tensile strength of 21 Mpa, and hydrostatic head resistance not less than 70m water head as per ASTM D5385 &elongation of 500% as per ASTM D 412, pe el adhesion ot concrete of 130 0 / m as per ASTM D903, Lap peel adhesion >450N/m as per ASTM D1876. The size of the membrane should be1.2m ×20 m. The pre-applied, fuly bonded HDPE sheet membrane shal be loosely laid on PC andgets bonded to theunderneath of the poured concrete of base/ raftslab and confined retaining wal. The fuly bonded HDPE sheet membrane shal consist of ahigh performanceEP film, selfadhesive polymerlayer and unique particulate layer with pressure sensitive adhesive, which bonds fully tothe poured concrete of baseslab/confined retaining wall. The membrane shall have minimum of75 mm side laps andend laps which shall be sealed with double sided adhesivetape.,etc complete as per manufactures specification and instructions.This shall include cleaning &removal of all the dust, dirt, oil,grease, cement laitance, loose particle & prepare the P.C.C. Substrate for laying of waterproofing system. as directed by Engineer In For Admin Building Basement Floor-2
For Item No.142 For Residential Building Basement Floor-2
ITEM No143: Smart CareUltron( Hybrid Polyurea)for Retaining Wals-Providing andlayingliquidbasedAsian Paintsor MYKorSikkaor quivalent make Smartcare Ultron or equivalent make (Polyurea-Polyurethane seamless/jointless treatment) for waterproofing on the Un-confinedvertical surface by cleaning the external surface, removal of loose concrete and filing cracks with polymer modified mortar &treatment of tie rod holes, bracing angle etc with plugging mortar, as per manufacturers' recommendation, thereafter, providing &applying onecoat of two component solvent free epoxy primer @0.15-0.20 kg/ m2, followed by providing &applying 2component high performancehybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, liquidmembrane with anelongation of 60% andtensile strength of 12.6 N/mm2 as per ASTM D2370, crack bridging ability of 3mm as per ASTMC1305, shore AHardness ofmin. 75 asper ASTM D2240. The system includes final base preparation, epoxyprimer application and applying in two coats at 1.5 kg per Sq.Metc, complete asper Manufacturer specifications.HDPE Termination at Raft withAluminium strip of width min. 75mm ,with theturnkey execution to be done by the manufacturer through itsinhousesubsidiaryexecution company and as directed by Engineer In charge For Admin Building Basement Floor-2
For Item No.143 For Residential Building Basement Floor-2
ITEM No.144: Providing, laying and fixing P.V.C. pipe of 75mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. D.S.R. I.No. 42.27 BDV 60 Page No. 227 Admin Building Ground Floor & GSR
For Item No.144 For Residential Building Ground Floor & GSR
For Item No.144 For Admin Building First Floor
For Item No.144 For Admin Building Second Floor
For Item No.144 For Admin Building Third Floor
ITEM No.146: Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint) Spec. No.: Bd.C.8 Page No. 278 D.S.R. I.No. 41.56 BDV 19 Page No. 271 For Admin Building
For Item No.146 For Residential Building
ITEM No.147: RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/ perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. Spec.: As directed by Engineer in charge D.S.R. I.No. 48.47 Page No. 317 For Admin Building
For Item No.147 For Residential Building
ITEM No.148: Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws, nuts, bolts, washers, cleats,weather silicon sealent, backer rods etc .overall weight of the ACP shall not be less than 7.5 kg/Sq.M) Spec.No. : As directed by Engineer in charge D.S.R. I.No. 51.100 Page No. 378 For Admin Building Ground Floor
For Item No.148 For Admin Building 1st Floor
For Item No.148 For Admin Building 2nd Floor
For Item No.148 For Admin Building 3rd Floor
ITEM No.149: Providing and fixing factory made uPVC twin sash casement glazed window and door comprising of two shutters, one outward opening having glass and one inward opening having S S Mesh and integrated grill provision between two shutters. uPVC multi-chambered frame, sash, bugmesh sash and mullion (whereever required) extruded profiles with wall thickness of 2.3mm (+-0.2mm) duly reinforced with G.I section 1.50 wherever required .uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1. Tensile Impact Strength ISO 8256-morethan 700Kj/m2 2. VicatSoftening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be<30MPa. All corners of frame and sash will be fusion welded. Mullion shall be welded /screwed. EPDM/ TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.8 Admin Building Ground Floor
There after, 5mm Float Annealed glass shall be provided in the sash with the help of uPVC glazing bead and hard ware, i.e., friction hinge & single point handle (inwindow) & 3D Hinges & Multipoint Lock (indoor) shall be provided. Window/ Door shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use a) Twin Sash Casement Window frame of size 122x 62mm, sash 67x 78mm & bug-meshsash of 42 x 84 mm. Spec.No. : As directed by Engineer in charge D.S.R. I.No. 54.10 Page No. 51 For Admin Building 1st Floor
For Item No.149 For Admin Building 2nd Floor
For Item No.149 For Admin Building 3rd Floor
ITEM No.150: Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 18 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with a continuous aluminium I Beam holding the base of the standing seam along the length of the panel & fixed with purlin with self-drilling hex head screws offering best stability with apull-out load of min. 21000N (21KN) tested as per ISO 6892:1998 and IS1608:2005., as per design requirement. Panels must satisfy Dart drop impact test as per IS14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTMD 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTMG 155. U value shall not be more than 1.9W/m2K as per EN ISO 10077-2:2018. Spec. No.: As directed by Engineer in charge. D.S.R. I.No. 51.189 Page No. 407 For Admin Building 3rd Floor
ITEM No.151: Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. Spec : Bd.K.1 Page No. 359 D.S.R. I.No. 30.01 BDK 1 Page No. 203 For Admin Building Basement Floor-1
For Item No.151 For Admin Building Basement Floor-2
For Item No.151 For Admin Building Ground Floor
ITEM No.152: Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixing T.W. battens on internal face, finishing etc. complete as directed. Spec : Bd.K.1 Page No. 359 D.S.R. I.No. 30.02 BDK 1 Page No. 203 For Admin Building Basement Floor-1
For Item No.152 For Admin Building Basement Floor-2
For Item No.152 For Admin Building Ground Floor
ITEM No.153: Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed. Spec : Bd.K.1 Page No. 359 D.S.R. I.No. 30.03 BDK 1 Page No. 203 For Admin Building Basement Floor-1
For Item No.153 For Admin Building Basement Floor-2
For Item No.153 For Admin Building Ground Floor
ITEM No.154: Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bituminous poured filler, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Complete as directed. Spec : Bd.K.1 Page No. 359 D.S.R. I.No. 30.04 BDK 1 Page No. 203 For Admin Building Ground Floor
ITEM No.155: Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. Spec : As directed by Engineer in charge. D.S.R. I.No. 46.15 BDW 8 Page No. 296 For Admin Building Ground Floor
ITEM No.156: Removing King Post truss from roof and stacking the materials as directed with all leads and lifts etc. complets Spec : Bd.W.8 Page No.587 D.S.R. I.No. 46.04 BDW 8-5B Page No. 296 For Admin Building Ground Floor
ITEM No.157: Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete. Spec : Bd.W.8 Page No.587 D.S.R. I.No. 46.06 BDW 8-8 Page No. 296 For Admin Building Ground Floor
ITEM No.158: Removing Manglore tiled roof and ridge tiles with battens, ridge and barge boards, eaves 8 A boards etc and sacking the materials as directed with all leads and lifts complete. Including removing wood work below etc. complete. Spec :As directed by Engineer in charge. D.S.R. I.No. 46.43 BDW Page No. 299 For Admin Building Ground Floor
ITEM No.159: Removing purlins from roof including stacking as directed with all leads , lifts etc. complete. Spec :As directed by Engineer in charge D.S.R. I.No. 46.35 BDW 8 Page No. 298 For Admin Building Ground Floor
ITEM No.160: Removing wooden or A.C. partition including frame work and stacking the materials as with all leads, lifts etc. complete. Spec :As directed by Engineer in charge. D.S.R. I.No. 46.17 BDW 8 Page No. 296 For Admin Building Ground Floor
ITEM No.161: Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete Spec :As directed by Engineer in charge. D.S.R. I.No. 46.17 BDW 8 Page No. 297 For Admin Building Ground Floor
ITEM No.162: Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. complete Spec : As directed by Engineer in charge. D.S.R. I.No. 46.09 BDW 8 Page No. 296 For Admin Building Ground Floor
ITEM No.163: Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. Spec :As directed by Engineer in charge. D.S.R. I.No. 32.33 BDL Page No. 211 For Admin Building Ground Floor
ITEM No.164: Providing and fixing C.P.Handshower (health faucet) 1m.PVC tube with wall hook jaquarmake (Cat. No. ALD 563 ) Spec : As directed by Engineer In Charge D.S.R. I.No. Sr,234 Page No. 536 For Admin Building 1st Floor
For Item No.164 For Admin Building 2nd Floor
For Item No.164 For Admin Building 3rd Floor
ITEM No.165:Providing and fixing 90cmx60cm Granite plate engraving10 cm.Height letter,figures including painting the lefters/figures with approved colour and shade complete : As directed by Engineer In Charge D.S.R. I.No. Sr,12.13 Page No. 85 item no-44.12 For Admin Building
ITEM No.166:Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover,cistern & wash basin fittings,nuts, bolts and gasket etc complete as per the direction of Engineer-In-charge. Spec : As directed by Engineer In Charge D.S.R. I.No. Sr,51.63 Page No.369 For Admin Building 1st Floor
For Item No.166 For Admin Building 2nd Floor
For Item No.166 For Admin Building 3rd Floor
ITEM No.167: Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Sq.M /kg with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Spec. No.: As directed by Engineer in charge. D.S.R. I.No. 31.09 BDJ Page No. 206 For Admin Building GSR
ITEM No.169: Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. By Mechanical Means. Spec. No.: MORTH 301 D.S.R. I.No. 2.11 MORTH 301 Page No. 23 For Admin Building
For Item No.169 For Residential Building
ITEM No.170: Excavation for roadway in hard murum and boulder including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m.and spreading for embankment or stacking as directed. Spec. No.: MORTH 301 D.S.R. I.No. 2.13 MORTH 301 Page No. 26 For Admin Building
ITEM No.71: Providing earth work in embankment with approved materials obtained from other sources upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from Other sources) Spec. No.: MORTH 305 D.S.R. I.No. 2.28 MORTH 305 Page No. 28 For Admin Building
For Residential Building
ITEM No.172: Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material Spec. No.: MORTH 401 D.S.R. I.No. 3.02 MORTH 401 Page No. 30 For Admin Building
For Item No.172 For Residential Building
ITEM No.173: Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, cement content not to be less than 150 kg/ Cu.M., optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of subgrade surface if required etc. complete. Spec. No.: MORTH 601 D.S.R. I.No. 5.13 MORTH 601 Cubic Page No. 30 For Admin Building
For Item No.173 For Residential Building
ITEM No.174: Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate ( VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. Spec. No.: MORTH 602 D.S.R. I.No. 5.03 MORTH 602 Cubic Page No. 45 For Admin Building
For Item No.174 For Residential Building
ITEM No.175: Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. Spec. No.: MORTH 602.5 D.S.R. I.No. 5.19 MORTH 602.5 Page No. 51 For Admin Building
For Item No.175 For Residential Building
ITEM No.176: Providing and fixing in position TMT FE 500, 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and PVC pipe of 32 mm dia wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete. Spec. No.: MORTH 602.6.5 D.S.R. I.No. 5.15 MORTH 602.6.5 Page No. 50 For Admin Building
For Item No.176 For Residential Building
ITEM No.177: Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete. Spec. No.: MORTH 602.6.4.2 D.S.R. I.No. 5.16 MORTH 602.6.4.2 Page No. 50 For Admin Building
For Item No.177 For Residential Building
ITEM No.178: Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. Spec. No.: MORTH 602.6.3 & 602.6.4 D.S.R. I.No. 5.17 MORTH 602.6.3 & 602.6.4 Page No. 51 For Admin Building
For Item No.178 For Residential Building
ITEM No.179: Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 mm.to 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer. (A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide) Spec. No.: MORTH 602.6.3 & 602.6.4 D.S.R. I.No. 5.18 MORTH 602.6.3 & 602.6.4 Page No. 51 For Admin Building
For Item No.179 For Residential Building
ITEM No.180: Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With natural sand Spec. No.: Bd. E. 1 Page No. 287 D.S.R. I.No. 24.01 BDE 1 Page No. 215 For Admin Building
For Item No.180 For Residential Building
ITEM No.181: Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 100MM thick in M-50 grade of approved size and shape for City streets and roads with high volume/ heavy traffice as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of VSI crushed sand of 50 mm thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete. Spec : As directed by Engineer Incharge D.S.R. I.No. 5.21 Page No. 52 For Admin Building
For Item No.181 For Residential Building
ITEM No.182: Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/Sq.M .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/Sq.M/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/Sq.M/ lux and Qd of 100 mcd/Sq.M/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). Spec. No.: MORTH 803.4. D.S.R. I.No. 6.12 a MORTH 803.4 Page No. 56 For Admin Building
For Item No.182 For Residential Building
ITEM No.183: Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retroreflectance of the reflecting panel, to the Engineer. Spec : MORTH 804 D.S.R. I.No. 6.09 MORTH 806 Page No. 54 For Admin Building
For Item No.183 For Residential Building
ITEM No.184: Providing and fixing stainless steel bollard of steel pipe 1.00 metre long of 250 mm inner diameter and circular top plate of 350 mm diameter with 5 mm thickness on deck of jetty in cement concrete including necessary fixtures and fastening etc. complete. (Stainless steel of grade S-304) Spec : As directed by Engineer -in- Charge D.S.R. I.No. 49.28 Page No. 410 For Admin Building
For Item No.184 For Residential Building
ITEM No.185: Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT Spec.: As directed by Engineer in charge D.S.R. I.No. 51.41 Page No. 359 For Admin Building
ITEM No.186: Providing & Arrangemnt of MId Back, Normal Syncro Mechanism, Fixed Armrest, Gaslift for Seat height adjustment, Standard 5- prong/Nylon Base with Leather Upholstery Spec : As directed by Engineer In Charge D.S.R. I.No. 51.42 Page No. 359 For Admin Building
ITEM No.187: Providing & Arrangemnt of Mid Back, ECO CTS Mechanism, Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery Spec : As directed by Engineer In Charge D.S.R. I.No. 51.43 Page No. 359 For Admin Building
ITEM No.188: Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. Spec : As directed by Engineer In Charge D.S.R. I.No. 51.44 Page No. 359 For Admin Building
ITEM No.189: Executive's Table @ 1800Lx 900D x750HT Providing & Fixing of Table @ 1800Lx 900Dx 750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing Spec : As directed by Engineer In Charge D.S.R. I.No. 51.21 Page No. 355 For Admin Building
ITEM No.190: Free Standing Table @ 1200Lx 600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, Spec : As directed by Engineer In Charge D.S.R. I.No. 51.28 Page No. 357 For Admin Building
ITEM No.191: Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. with 12 Compartments , Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color. Spec : As directed by Engineer In Charge D.S.R. I.No. 51.38 Page No. 359 For Admin Building
ITEM No.192: CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test. For Admin Building
For Item No.192 For Residential Building
ITEM No.193: BASIC TEST OF AGGREGATE. Sieve Analysis test. For Admin Building
For Item No.193 For Residential Building
ITEM No.194: BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test. For Admin Building
For Item No.1894 For Residential Building
ITEM No.195: FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test. For Admin Building
For Item No.195 For Residential Building
ITEM No.196: BASIC TEST OF AGGREGATE. Water Absorption, Specific Gravity,Impact Value Crushing Value test. For Admin Building
ITEM No.197: BASIC TEST OF CEMENT.Standard Consistancy Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength and Soundness test. For Admin Building
ITEM No.198: Concrete Mix Design (With all Tests on basic materials). For Admin Building
For Item No.198 For Residential Building
ITEM No.199: STEEL BAR TESTING Upto 16 mm (Set of 3 Bars) For Admin Building
For Item No.199 For Residential Building
ITEM No.200: STEEL BAR TESTING Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress). For Admin Building
For Item No.200 For Residential Building
ITEM No.201:SOIL / MURUM Compaction Test (Proctor Density). For Admin Building
For Item No.201 For Residential Building
ITEM No.202:SOIL / MURUM Liquid limit & plastic Limit test. For Admin Building
For Item No.202 For Residential Building
ITEM No.203: SOIL / MURUM Field Density test by Sand Replacement Method. For Admin Building
ITEM No.204: BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test. For Admin Building
For Item No.204 For Residential Building
ITEM No.205: MORTOR Compressive Strength ( Set of 3 Cubes) test. For Admin Building
For Item No.205 For Residential Building
ITEM No.206: CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test. For Admin Building
ITEM No.207: PAINT / THERMO-PLASTIC PAINT Reflectance & yellowness index Test. For Admin Building
For Item No.207 For Residential Building
ITEM No.208: PAINT / THERMO-PLASTIC PAINT Softening Point (Ring & ball method) Test. For Admin Building
For Item No.208 For Residential Building
ITEM No.209: PAINT / THERMO-PLASTIC PAINT Drying Time Test. For Admin Building
For Item No.209 For Residential Building
ITEM No.210: Glass bead contents & grading analysis. For Admin Building
For Item No.210 For Residential Building
ITEM No.211:GSB Mix Design For Admin Building
For Item No.211 For Residential Building
ITEM No.212: WATER- PH Value, Sulphate & Chloride Content For Residential Building
ITEM No.213: Plate Load Test For Admin Building
For Item No.213 For Residential Building
Supplying and erecting HT CT multifunction DLMS compliance of accuracy of class 0.5 3x63.5V 50 Hz with optical & RS 232 port backlit LCD measures kWh kVAh V I kW 6 months history of energy load survey & displays trivector energy load survey TOD tamper detection & logging power ON /OFF events instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box. [6-3-6] For Admin Building
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2] For Admin Building
Supplying, erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(UE) 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT [7-3-9] For Admin Building
Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT [7-5-12] For Admin Building
Providing and erecting Heat shrinkable out door termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT [7-5-15] For Admin Building
Supplying and erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-4] For Admin Building
Supplying and laying (including excavation) half round reinforced cement concrete pipe of IS 458 2003 NP-2 class of 150 mm internal diameter in proper line level and slope including providing and fixing collars in cement mortar 1 2 and curing etc. complete. [7-6-6] For Admin Building
Supplying and erecting rolled steel joist (girder) pole 150 x 80 mm/150 x75 mm (14.9 kg /m) with base plate in provided foundation as per specification no. OH-PL/RSJ [8-1-11] For Admin Building
Supplying and erecting bracket for guarding of HT OH Line made from channel iron 1600mm in length and 65x65x6mm thick erected on pole as per specification no. OH-PL/VCA [8-3-16] For Admin Building
Supplying and erecting G.I. stay set for poles including loop insulators at inaccessible height with anchor plate 300x300x6 mm. straining screws G.l. stay wire 7/8 SWG G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. [8-6-2] For Admin Building
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1] For Admin Building
For Item No.11 For Residential Building
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-2] For Admin Building
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2] For Admin Building
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3] For Admin Building
For Item No.14 For Residential Building
Supplying, installing, testing and commissioning of 3 phase 11/0.433 kV 50 Hz. 250 kVA Mineral oil immersed and naturally cooled outdoor type Copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side temperature rise should not Exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5% having 7 number of tap positions with standard accessories complete with test certificate with losses below 980 Watts at 50% load 2930 Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-NSL. [10-1-6] For Admin Building
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG [10-6-18] For Admin Building
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class GI pipe with angle iron supports chain link wire mesh (jali) complete supported on channel iron erected in foundation and painted complete as per specification no SS-AS/DLD [10-6-20] For Admin Building
Providing printed instruction chart for treating persons suffering from electric shock printed in English & Marathi and duly laminated complete. [10-6-22] For Admin Building
Providing pair of duly tested rubber hand gloves as per IS 47705 suitable for working up to 22 kV supply complete. [10-6-23] For Admin Building
Supplying standard first aid box with necessary antiseptic cream medicine for use on wounds due burn crepe bandage gauge bandage medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use scissors anti-septic solution etc. (All above contents shall be of standard makes) [10-6-24] For Admin Building
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS 15652 – 2006 having 2 mm thickness up to 3.3 kV [10-6-25] For Admin Building
Supplying shock proof leather safety shoes of electrical grade of standard size as IS 11226 14544 duly tested with necessary test certificate from manufacturer. [10-6-28] For Admin Building
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excited self-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G2 and maximum fuel consumption 34.40 Ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m provided with first filling of oil diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG [11-1-17] For Admin Building
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase 415 Volts 50Hz A.C. with all standard features safeties etc as per specification no. GEN-AMF. (WITH NOTE OF 10% IN CASE OF NEW DG) [11-2-14] For Admin Building
Supplying, installing, testing and commissioning of FR XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-11] For Admin Building
For Item No.25 For Residential Building
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.(5.4*3.5*0.3) [16-1-5] For Admin Building
For Item No.26 For Residential Building
second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1 6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually striking joints on unexposed faces raking out joints on exposed faces and watering etc. Complete. [16-2-1] For Admin Building
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. [16-2-3] For Admin Building
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. [16-3-1] For Admin Building
Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1 3 6 cement concrete 20 x 25 mm stone metal 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered with necessary curing and finishing complete. (for above 9 m poles) [16-3-4] For Admin Building
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). (5.4*3.5) [16-3-5] For Admin Building
For Residential Building
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1 3 6 cement concrete (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). [16-3-6] For Admin Building
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9] For Admin Building
For Item No.33 For Residential Building
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-10] For Admin Building
For Item No.34 For Residential Building
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-12] For Admin Building
For Item No.34 For Residential Building
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1] For Admin Building
For Item No.36 For Residential Building
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1] For Admin Building
For Residential Building
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2] For Admin Building
For Residential Building
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2] For Admin Building
For Residential Building
Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3] For Admin Building
For Residential Building
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3] For Admin Building
For Residential Building
Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3] For Admin Building
Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4] For Admin Building
Supplying and erecting mains with 4x 10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-5] For Admin Building
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1] For Admin Building
For Residential Building
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2] For Admin Building
For Residential Building
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10] For Admin Building
For Residential Building
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11] For Admin Building
For Residential Building
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23] For Admin Building
For Residential Building
Supplying and erecting modular type blanking plate one module duly erected on provided plate & box. [1-6-24] For Admin Building
For Residential Building
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35] For Admin Building
For Residential Building
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-36] For Admin Building
For Residential Building
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-39] For Admin Building
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-40] For Admin Building
For Residential Building
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5] For Admin Building
For Residential Building
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6] For Admin Building
For Residential Building
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-15] For Admin Building
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-16] For Admin Building
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26] For Admin Building
For Residential Building
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2000 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-5] For Admin Building
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2750 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-6] For Admin Building
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-16] For Admin Building
For Residential Building
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18] For Admin Building
For Residential Building
Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing heat sink integrated HF electronic driver Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt CRI>80 CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. [2-1-22] For Admin Building
For Residential Building
Supplying and erecting Electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. [2-3-15] For Admin Building
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-14] For Admin Building
For Residential Building
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21] For Admin Building
For Residential Building
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. [2-11-5] For Admin Building
For Residential Building
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6] For Admin Building
For Residential Building
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC22 [3-3-9] For Admin Building
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) [3-5-1] For Admin Building
Supplying, installing, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-3] For Admin Building
Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire duly charged with 12 months warranty complete [3-8-8] For Admin Building
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2] For Admin Building
For Residential Building
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3] For Admin Building
For Residential Building
Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10] For Admin Building
For Residential Building
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11] For Admin Building
For Residential Building
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1] For Admin Building
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4] For Admin Building
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 8 ways /24 poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-5] For Admin Building
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-9] For Admin Building
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13] For Admin Building
For Residential Building
Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 [5-4-15] For Admin Building
Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-1] For Admin Building
Supplying, Erecting and Commissioning of 4 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-4] For Admin Building
Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5] For Admin Building
Supplying, Erecting and Commissioning of 4 pole RCCB 63A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-6] For Admin Building
Supplying, Erecting and Commissioning of 4 pole RCCB 100A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-8] For Admin Building
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9] For Admin Building
Supplying and erecting 100 kVAr 440 V 3 phase 50 Hz. Contactor Logic & Intelligent Relay micro APFC passive filter panel consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC [6-7-5] For Admin Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-17] For Admin Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-24] For Admin Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-33] For Admin Building
For Residential Building
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. [7-11-6] For Admin Building
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3] For Admin Building
Supplying and erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. [9-3-1] For Admin Building
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. [1-6-29] For Admin Building
For Residential Building
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15] For Admin Building
For Residential Building
Supplying, erecting and marking DPMCB 6 A to 32 A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-7] For Admin Building
For Residential Building
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8] For Admin Building
Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-13] For Admin Building
For Residential Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-8] For Admin Building
For Residential Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq mm copper conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-9] For Admin Building
For Residential Building
SITC of Electric Traction Passenger Lift with · Rated capacity - 10 Passenger/680Kg · Floors - G+1 floor (2 Stops/2 Landings) · Travel - 3 to 4.2 mtrs · Location of Lift Machine - MR/MRL · Rated speed - 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep ......mm Pit depth ………mm Overhead. · Doors type - COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick with hairline finish with frame made from MS girders bracing of adequate size with minimum safety factor of 5 with Toe Guard Apron with necessary false ceiling with adequate LED lights blower/fan for ventilation & SS chequered plate flooring handrails mirror emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI scrolling UP/DN LED indicator & with / without attendant key switch OWD with audio-visual alarm VAS in Marathi Hindi & English with intercom system with telephone instrument in Lift car LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent overvoltage over speed overheat for all devices including lift motor and travel direction protection protection for phase loss at input or output etc. various operation modes such as maintenance change direction by attendant full load bypass VIP call operation self levelling operation call cancel facility auto return to home landing fireman evacuation operation earthquake operation door open/close operation from COP etc. The system can record information for minimum 30 latest faults with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength copper wire for power & control circuit with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory) with Traction pulley OSG electromagnetic brakes entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners counter weight frame with necessary blocks buffers with necessary support arrangement MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill header hole pass etc complete with plaster finish civil work for erection buffers erection of lift machinery adequate size core cuts if required & scaffolding for erecting guide rails providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General - Job includes entire procedure of obtaining all necessary erection permissions & License to Work the Lift from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. ADD ON For Lift travelling up to six floors or at a speed of 1.0 mps add as below For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel] this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators extension of guide rails shaft wiring with trunking traveling cables main hoisting ropes/belts & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. ADD ON CAMERA CFor additional 2MP Camera along with necessary accessories at Home Landing add as given. ( LIFT 1299498+ 137031*4 + 13400*4= TOTAL RS.1901222/-) [17-1-4]
For Residential Building
Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC [3-2-13] For Admin Building
Supplying, installing, testing and commissioning of cassette type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room Air conditioning unit 1.8TR to 2.1TR capacity having ISEER minimum 5.00 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condenser dust filter self diagnosis feature stabilizer free operation noise level maximum 50dBA at position as per specification no. APAC/ WAC [3-2-18] For Admin Building
Supplying, installing, testing and commissioning of cassette type room Air conditioning unit 2.8TR to 3.3TR capacity with refrigerant R32/R410A 415V 50 Hz A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit dust filter noise level maximum 50dBA at position as per specification no. APAC/ WAC [3-2-20] For Admin Building
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. [3-2-26]For Admin Building
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. [3-2-27]For Admin Building
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. [3-2-28]For Admin Building
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system. [4-2-9] For Admin Building
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system. [4-2-10] For Admin Building
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system. [4-2-12] For Admin Building
Supplying and erecting modular type T.V. socket single outlet duly erected on provided plate and box with wiring connections complete. [1-6-14] For Admin Building
For Residential Building
Supplying and erecting modular type telephone socket one gang with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-15] For Admin Building
For Residential Building
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected. [1-6-26] For Admin Building
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-34] For Admin Building
Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-1] For Admin Building
Supplying and erecting 10 pair 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier polythene sheathed G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW [1-8-13] For Admin Building
Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW [1-8-18] For Admin Building
For Residential Building
Supplying, Erecting and Commissioning of MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW [1-9-1] For Admin Building
Supplying, Erecting and Commissioning of 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW [1-9-11] For Admin Building
Supplying, Erecting and Commissioning of 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW [1-9-18] For Admin Building
Supplying, Erecting and Commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. [1-9-26] For Admin Building
Supplying, Erecting and Commissioning of push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. [1-9-29] For Admin Building
Supplying, Erecting and Commissioning of IP telephone instrument as per specification complete. [1-9-30] For Admin Building
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1] For Admin Building
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC [1-10-16] For Admin Building
Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC [1-10-18] For Admin Building
Supplying, fixing, and configuring 8-ports managed gigabit Layer-2 switch 10/100/1000 base-T POE smart switch plus 2 SFP erected in provided rack complete. [1-11-2] For Admin Building
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port ethernet managed switch with web view/CLI 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS [1-11-4] For Admin Building
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1] For Admin Building
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO [1-12-2] For Admin Building
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP [1-12-4] For Admin Building
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK [1-12-17] For Admin Building
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK [1-12-18] For Admin Building
Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x600x635 mm) as per specification No. WG-NAS/RAK [1-12-19] For Admin Building
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14] For Admin Building
For Residential Building
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 4400 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. [2-4-4] For Admin Building
For Residential Building
For Residential Building
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12] For Admin Building
For Residential Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-27] For Admin Building
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-9] For Admin Building
For Residential Building
Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL [8-2-12] For Admin Building
For Residential Building
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-21] For Admin Building
For Residential Building
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-22] For Admin Building
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4] For Admin Building
For Residential Building
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). [16-3-9] For Admin Building
For Residential Building
Supplying and erecting triple pole mini feeder pillar with 500V 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles self locks gasket having IP54 IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP [5-2-2] For Admin Building
Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-21] For Admin Building
For Residential Building
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC [1-10-7]
For Residential Building
Supplying and installing armoured single mode optical fibre cable with 6 fiber core dia 50/125µm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete. [1-10-9] For Admin Building
Supplying and installing 3 m fibre patch cord duplex single mode for OS1/OS2 complete. [1-10-21] For Admin Building
Supplying and fixing IP66 enclosure for fibre splicing complete. [1-10-29] For Admin Building
Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete. [1-11-1] For Admin Building
For Residential Building
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK [1-12-17] For Admin Building
For Residential Building
Supplying, fixing, and configuring media convertor 1000 Base-T to 1000 base-SX SC multi-mode media converter (550m) complete [1-12-38] For Admin Building
Supply Installation commissioning of 4 MP Full HD IP Dome / Bullet Camera Image Sensor 1/3 4 megapixel progressive scan CMOS Effective Pixels 2304 (H) × 1296 (V) Electronic Shutter Speed Auto/Manual 1-1/100000 s Min. Illumination 0.1 lux F2.1 (Color) 0 lux (IR LEDs on IR Distance - nUp to 100 ft (30 m) Day/Night -auto (ICR)/Color/BW Backlight Compensation - BLC/HLC/DWDR White Balance - Auto/Manual Gain Control - Auto/Manual Noise Reduction - 3D Privacy Masking- Up to 4 areas Lens Focal Length- 2.8 mm Horizontal Angle of View 92° 86°-28 Compression H.264 (Main/High/Baseline Profile) /MJPEG Resolution 3 MP (2304×1296) 1080p Main Stream 3 MP (1-20 fps) 1080p (1-25/30 fps) Corridor Mode Support Network Protocol IPv4/IPv6 HTTP HTTPS TCP/IP UDP UPnP ICMP IGMP RTSP RTP SMTP NTP DHCP DNS PPPoE DDNS FTP IP Filter QoS Compatibility -nONVIF Profile S CGI Max User Access 20 users Mobile App - for iPhone iPad Android Phone and Tablet Power Supply PoE (802.3af) 12 V DC Working Environment -22°F to 140°F (-30°C to 60°C) 10% to 100% RH condensing Ingress Protection IP66 Vandal Resistance - IK10 Regulatory FCC Part 15B Class B -(CSR Rate Approved by SE PREC Pune Vide letter No.39/2022-23 dated 20/9/2022 ) [35-1-1] For Admin Building
For Residential Building
Supplying and erecting Supplying erecting testing & commissioning of NVR 32 Channel professional series 4K HD Network Video \ORecorder . Smart H.265+ /H.265/Samrt H.264+. Max 320Mbps Incoming Bandwidth .Up to 12MP Resolution for Preview& Playback Bit Rate 16Kbps20Mbps per channel. 2HDMl/2VGA simultaneous video output to enhance the storage eliability when the network break down . Quad-Core embeded processor . 8 SATA Ill Ports Up to 6 TB for each HDD for 48TB Storage 2 R]45 port (10/100/lOOOMbps) Independent of Joint etworking. Analytical Features Like - ANPR People Count Face Detection Missing/Abondoned Objects Tripwire and Intrusion alarms Smart FAN to achive High Cooling Effect .Automatic Network the video data stored on the camera. (3 years warranty) -(CSR Rate Approved by SE PREC Pune Vide letter No.39/2022-23 dated 20/9/2022 ) [35-2-1] For Admin Building
For Residential Building
Supply installation and commissioning of 42' Full HD Commercial LED Display /Monitor 42 inches or higher Full HD VGA DYi HDMI LAN USB RGB RS 232C IN/OUT AV IN COMPONENT IN AUDIO IN/OUT WIFI READY SPEAKERS (-CSR Rate Approved by SE PREC Pune Vide letter No.39/2022-23 dated 20/9/2022 ) [35-5-1] For Admin Building
For Residential Building
Supply and Installation of 4 TB Surveillance Hard Disk Non-(CSR Rate Approved by SE PREC Pune Vide letter No.39/2022-23 dated 20/9/2022 ) [35-3-2] For Admin Building
For Residential Building
Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.[3-11-88] For Admin Building
Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete [3-11-82] For Admin Building
Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629 1985 to be used for fabrication of boxes panel boards etc. including cutting bending drilling welding riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint [6-1-4] For Admin Building
Supplying, erecting, testing and commissioning of manually operated opposed blade duct mounted flanged volume control dampers of required sizes in GI construction with operating mechanism mounting arrangement rubber refrigerant kits etc. complete. [3-11-80] For Admin Building
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-20] For Admin Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-10] For Admin Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-9] For Admin Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-8] For Admin Building
Supplying, installing, testing and commissioning of FR XLPE armoured cable 8 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-12] For Admin Building
Supply.installation .testing & commissioning of Dual Speed Smoke Spill Axial Fans (fire rated for 250 degree C for 2 hrs) complete with aluminium alloy blades with aerofoil design bird screen & motor shall be of 415 + 10 % volts 50 hz Class H IP 55 Gravity louvers will be provided at the discahge of the fan so as to avoide for Exhaust air fan fans should be suitable for outdoor installation for Normal / Fire Mode . Fan Capacity 10000/20000CFM 30MM SP [36-1-11] For Admin Building
Supply.installation .testing & commissioning of Dual Speed Smoke Spill Axial Fans (fire rated for 250 degree C for 2 hrs) complete with aluminium alloy blades with aerofoil design bird screen & motor shall be of 415 + 10 % volts 50 hz Class H IP 55 Gravity louvers will be provided at the discahge of the fan so as to avoide for Exhaust air fan fans should be suitable for outdoor installation for Normal / Fire Mode . Fan Capacity 6000/12000CFM 30MM SP [36-1-12] For Admin Building
Supply.installation .testing & commissioning of Single Speed Fresh Air Axial Fans (fire rated for 250 degree C for 2 hrs) complete with aluminium alloy blades with aerofoil design bird screen & motor shall be of 415 + 10 % volts 50 hz Class H IP 55 Fan Capacity 7000CFM 30MM SP [36-1-13] For Admin Building
Supply of Ductless Induction Ceiling Suspended Ventilation with Impulse Jet Fan Assembly suitable for 300 deg.C X 2 Hrs. Rating with Fire and Normal Mode . [36-1-14] For Admin Building
Supply Installation Testing commissioning Of Actuator With It's Cabling for Supply Air & Fire Dampers [36-1-15] For Admin Building
Supply Installing Testing and Commissioning of Co2 Sensor with display to read on modbus with loop as per approved specifications & drawings [36-1-16] For Admin Building
Supply Installation Testing & Commissioning of All control cables Signal and Communication Cable - Armoured (PVC Sheathed ATC ( Annealed Tinned Copper) shielded cable) laid in PVC Piping and clamped .(2 Core 1.00 Sqmm Copper shielded Cable) [36-1-19] For Admin Building
Supply.installation .testing & commissioning of Immergency stop button station. [36-1-20] For Admin Building
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [3-11-77] For Admin Building
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1] For Admin Building
For Residential Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-15] For Admin Building
For Residential Building
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. [7-11-8] For Admin Building
Supplying, installing, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/EP [13-1-4] For Admin Building
Supplying, installing, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type multi stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete as per specification no. FF-MFP/JP [13-2-2]
Supplying, installing, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type single/multi stage centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/BP [13-3-1] For Admin Building
Supplying, installing, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520.(b) Water cooled with radiator diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v 50Hz AC supply diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding residential silencer instruments and protection as per standard specification stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/DP [13-4-2] For Admin Building
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-2] For Admin Building
For Residential Building
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-3] For Admin Building
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-4] For Admin Building
For Residential Building
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-5] For Admin Building
For Residential Building
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-6] For Admin Building
For Residential Building
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-7]For Admin Building
Providing G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-8] For Admin Building
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. [13-6-10] For Admin Building
Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern PN16 pressure rating screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS [13-7-8] For Admin Building
Supplying and erecting 100 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13-7-14] For Admin Building
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13-7-15] For Admin Building
Supplying and erecting 200 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13-7-16] For Admin Building
Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-17] For Admin Building
Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-18] For Admin Building
For Residential Building
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-19] For Admin Building
For Residential Building
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-20] For Admin Building
For Residential Building
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-21] For Admin Building
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-24] For Admin Building
For Residential Building
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-25] For Admin Building
Supplying and erecting 200 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-26] For Admin Building
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV [13-7-35] For Admin Building
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV [13-8-2] For Admin Building
For Residential Building
Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL [13-8-4] For Admin Building
For Residential Building
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ [13-8-8] For Admin Building
For Residential Building
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC [13-8-10] For Admin Building
For Residential Building
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT [13-8-12] For Admin Building
Supplying and erecting 20/25mm dia gun metal air release cock with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV [13-8-13] For Admin Building
For Residential Building
Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG [13-8-14] For Admin Building
For Residential Building
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve G.I. nipple elbow etc complete as per specification no. FF-FFA/PS [13-8-15] For Admin Building
For Residential Building
Supplying and erecting brass orifice plate having 6 mm. thickness 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP [13-8-16] For Admin Building
For Residential Building
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8 x 6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-19] For Admin Building
For Residential Building
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve hose pipe hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8 x6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-20] For Admin Building
For Residential Building
Supplying, installing, testing and commissioning of remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI [13-9-9] For Admin Building
Supplying, installing, testing and commissioning of FR XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-10] For Admin Building
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop with on-board LCD display with min 16 lines of text operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition suitable provision for network connectivity interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908 2021 IS 2189 2008 EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. [13-10-2] For Admin Building
Supplying, installing, testing and commissioning of addressable optical smoke detector single/twin LED’s with 360 degree view suitable for low voltage 15 to 32 V DC two wires supply in-built locking mechanism to check the removal and pilferage of the detector in built isolation mode start up current 300µA and alarm condition current shall be maximum 6.5 mA operating temperature 0°C to 50°C humidity 0-95% RH IP 41 conforming to IS 2189 2008 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD . [13-10-6] For Admin Building
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors in built isolation mode suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS 2175 - 1988 reaffirmed 2000 IS 15908 2021 standards FF-AFAS/SD. [13-10-7] For Admin Building
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type) made of addressable break glass plastic square in shape surface/flush mounted with Break Glass massage embedded on the glass complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. [13-10-9] For Admin Building
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 reed relays EN 54 or UL Listed FF-AFAS/CRM [13-10-10] For Admin Building
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/MM [13-10-11] For Admin Building
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/ISM [13-10-12] For Admin Building
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908 2021 with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54 conforming to IS 2189 2008 IS 15908 2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. [13-10-13] For Admin Building
Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR [13-11-1] For Admin Building
Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC [13-11-2] For Admin Building
Supplying, erecting, testing and commissioning of stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector stere o jack complete as per specification no. FF-PA/MIC [13-11-3] For Admin Building
Supplying, erecting, testing and commissioning of rust free microphone floor stand of chrome plating/powder coating or S.S. material 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete. [13-11-4] For Admin Building
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC [13-11-6] For Admin Building
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete. [13-11-10] For Admin Building
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler 15 mm (½ ) dia. NBCM Body chrome finished 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. [13-12-1] For Admin Building
For Residential Building
Supplying, erecting, testing and commissioning of vane type water flow detector 75/80 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. [13-12-2] For Admin Building
Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. [13-15-1] For Admin Building
For Residential Building
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete. [16-1-6] For Admin Building
For Residential Building
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP. [16-5-10] For Admin Building
For Residential Building
Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP. [16-5-11] For Admin Building
Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. [13-8-1] For Admin Building
For Residential Building
Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages in PVC/Vinyl 4/6mm thick sheet or as per sample approved by client viz fire hydrant fire hydrant fire extinguishers fire exists fire door fire hose box fire & Electrical & safety etc size 300mm* 100 mm (Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 ) [13-15-1] For Admin Building
For Residential Building
Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages viz fire hydrant fire hydrant fire extinguishers fire exists fire door fire hose box fire & Electrical & safety etc size 450mm* 150 mm (Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 ) [13-15-2] For Admin Building
For Residential Building
Supply & Eracting 1000 mm long 25 mm dia. Stainless steel corrugated flexible pipe (hose)nfor dropping sprinkler below false ceiling pipe shall have 16 bar rating and with union/reducer coller clamps etc. as required.(Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 ) [13-15-3] For Admin Building
For Residential Building
Supply lnstaltation testing & commisrioning of flow switches in 80/100/150 mm dia pipe with all acceslories as required. [13-15-4] For Admin Building
Rossette Plate powder coated in white/off white colour with 25 mm dia. Hole. (Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 ) [13-15-5] For Admin Building
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12] For Admin Building
Supplying, fixing, and commissioning MCB type change over switch 4 pole 40A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS [5-3-25] For Admin Building
For Residential Building
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nut bolts etc. complete with compliance to IS 720 2010 [6-1-14] For Admin Building
For Residential Building
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-20] For Admin Building
Supplying and erecting minimum Three & above star rated submersible pump set of 3.75 KW/5 HP with 415 V 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 210 to 860 LPM discharge at 38 to 13 m head & discharge & delivery Pipe of Size-65mm diameter with a necessary H type clamps as per specification No. WP-SMP [12-2-6] For Admin Building
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP [12-3-1] For Admin Building
Supplying and erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. [12-4-8] For Admin Building
For Residential Building
Supplying and erecting Water level controller 230/415 V A.C. Four way under ground & Over head tank operation only. [12-4-15] For Admin Building
For Residential Building
Supplying and erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos) [12-4-16] For Admin Building
For Residential Building
Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc . [12-4-17] For Admin Building
For Residential Building
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. [16-5-6] For Admin Building
For Residential Building
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete. [16-5-18] For Admin Building
Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. [16-6-15] For Admin Building
For Residential Building
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. [16-6-21] For Admin Building
For Residential Building
Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4] For Admin Building
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]For Admin Building
Supplying and erecting modular type bell-push with indicator 2 modules 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-4] For Admin Building
Wiring for plug on board with flush Switch socket copper wiring and earthing as per specification No WG-PW/SW [1-7-25] For Admin Building
Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 770 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-2] For Admin Building
Supplying, erecting and marking DPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-6] For Admin Building
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8] For Admin Building
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-9] For Admin Building
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1] For Admin Building
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9] For Admin Building
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars 500V 100A having 15mm (Width) X 3 mm (Thickness) with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB [6-2-1] For Admin Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-17] For Admin Building
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3] For Admin Building
Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13] For Admin Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-26] For Admin Building
Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 100 to 450 LPM discharge at 53 to 5 m head & discharge & delivery Pipe Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP [12-2-4] For Admin Building
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP [12-3-1] For Admin Building
Supplying and erecting ISI mark GI pipe 100 mm dia. ‘B’ class at position with accessories complete. Specification no. CW-PLB/GP. [16-5-9] For Admin Building
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-28] For Admin Building
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [3-11-77] For Admin Building
Supplying, installing, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type single/multi stage centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation on with IP 55 protection for enclosure horizontal foot mounted type with Class-F insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/BP [13-3-2] For Admin Building
Supplying and erecting stainless steel double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV [13-7-37] For Admin Building
Supplying, installing, testing and commissioning of manual call point (Pill box) with break glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP [13-9-7] For Admin Building
Supplying, installing, testing and commissioning of hooters having high (100dB 1m) and low (94dB 1m) volume setting group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR [13-9-8] For Admin Building
Supplying, installing, testing and commissioning of ETC solar water heating system without heat exchanger type of 300 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I 2004 complete as per specification no. ESD-SHWS-ETC [4-1-8] For Admin Building
Supplying, installing, testing and commissioning of ETC solar water heating system without heat exchanger type of 500 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I 2004 complete as per specification no. ESD-SHWS-ETC [4-1-9] For Admin Building
Supplying and erecting GI pipe 25 mm dia B class 4.05 mm thickness with resin bonded flap rock wool /glass wool insulation with necessary material as per specification No. ESD-HWP/TGP [4-2-3] For Admin Building
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-19] For Admin Building
Supplying and erecting 40/50 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-21] For Admin Building
Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet outlet overflow pipe inclusive of all tanks capacity up to 20000 litres. [4-8-7] For Admin Building
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating as per specification no. FF-VL/GV [13-7-32] For Admin Building
Supplying and erecting non return valve 25 mm dia in position made of gun metal complete. [16-6-19] For Admin Building
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-6] For Admin Building
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19] For Admin Building
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. [1-6-30] For Admin Building
Vikram Infratech Developers Private Limited
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid