Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹40.6 LAccepted-AOC 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | L-1 | Accepted-AOC Deposited performance security money | |
| 2 | L-2₹41.6 L+₹1.0 L (2.51%)Rejected-AOC ETTA BHATTA MAINROAD SURAJPUR BHATGAON SURAJPUR CHHATTISGARH | DURG | CHHATTISGARH | 490001 | L-2 | Rejected-AOC L-1 is eligible for AOC | |
| 3 | Rejected-Technical AT DHORI STAFF QTR PO DHORI DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | - | Rejected-Technical work experience not as per requirement of work of NIT | |
| 4 | Rejected-Technical 00 MUKUNDPUR PAHO DOMANPUR MUKUNDPUR PAHO MIRZAPUR UTTAR PRADESH 231306 | MIRZAPUR | UTTAR PRADESH | 231306 | - | Rejected-Technical work experience not as per requirement of work of NIT | |
| 5 | Rejected-Technical AT PIPRADIH PS CHANDRAPURA DIST BOKARO PIN 828403 JHARKHAND | CHANDRAPURA | BOKARO | JHARKHAND | 828403 | - | Rejected-Technical work experience not as per requirement of work of NIT |
Tender Value
₹53.1 L
EMD Value
₹66,400
Closing Date
6 Sept 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO(EnM), BnK
GM Office, BnK Area, Bermo, Bokaro, Jharkhand.
Replacement of damaged colony overhead lines for different colonies under Kargali OCP of BnK Area.
2024_CCL_315597_1
SO(EnM)/e-tender/24-25/13
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
Kargali OCP
As per NIT
2 documents required · 2 mandatory
₹66,400
23 Jan 2025
22 Aug 2024
7 Sept 2024
22 Aug 2024
6 Sept 2024
23 Aug 2024
22 Aug 2024 - 30 Aug 2024
Amount
Supply of 200 kg PCC/RCC pole of length 8 mtr.
Erection of RCC/PCC pole strut in brick ballast and ramming the foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc as required.
Supply of 3C x 150 sqmm + 1C 70 sqmm aerial bunched cable
Supply of 3C x 70 sqmm + 1C 50 sqmm aerial bunched cable
Supply and erection of Stay set complete (glavnised) with 19/20 mm dia x 1.8 mtr long stay rod, anchor plate of size 45 cm x 7.5mm, thimble, stay clamps, turn buckle (20mm x 60 cm) 7/3.15 mm dia GI stay wire and strain insulator etc. in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supply of Anchor clamp (3-bolt and 2-bolt type) with insulation for AB cable
Erection of anchor clamp for AB cable
Supply and fitting of I-hook for anchor / suspension clamp assembly.
Supply and fitting of GI clamp for rail /tubular pole
Supply and fitting of Insulation piercing connectors with cover or P.G. connectors with insulation cover-70 sq.mm.
Supply and fitting of Insulation piercing connectors with cover or P.G. connectors with insulation cover-150 sq.mm.
Supply of LT suspension clamp assembly with bracket for AB cable.
Fitting of LT suspension clamp assembly with bracket for AB cable.
Erection of AB Cable all sizes including binding etc as required. AB Cable 1197m X 1.980 kg/m = 2257.2 kg + 1.56 km x 1175 kg/km = 1833 kg. Total = 4299.65 kg
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of overhead lines comprising of aluminum overhead conductor, GI wire, cross arms, insulators etc. as required 2230 mtr x 4 wire = 8924 mtr = 8.92 km x 272 kg/km = 2426.24 kg + Pin – 420 nos x 2 kg = 840 kg total = 3266.24 kg
Supply and erection of AB cable service distribution box of different size as required with Power connection
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. with 2 x 4 sq sqmm
Service wire disconnection and connection to distribution box
Total impact of GST for the purpose of CTC
M/S UMASHREE ENGINEERING
techsummary_327064.pdf
PDF • 3.08 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_327064.pdf
PDF • 0.20 MB
WO65.pdf
PDF • 2.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .