Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹17.9 L+₹3.7 L (25.9%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-Finance Higher side quoted | |
| 3 | L3₹19.4 L+₹5.2 L (36.3%)Rejected-Finance | L3 | Rejected-Finance Higher side quoted |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
8 Feb 2024, 6:00 pmClosed
GE (AF) AMLA
GE AF Amla, Betul Dist 460553 (MP)
Repair to internal flame proof light fittings/exhaust fans at certain WSA/Amn workshop at AFS Amla
2024_MES_636980_1
8566/E-8 of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE(AF) AMLA
as per tender documents
8 documents required · 8 mandatory
₹500
GE(AF)AMLA
₹30,000
Yes
10 Apr 2024
11 Jan 2024
13 Feb 2024
11 Jan 2024
8 Feb 2024
22 Jan 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.
Taking down ceiling fans of any size/sweep after disconnecting the wire from existing ceiling rose and refixing the same after cleaning dust, oiling, greasing including providing flexible cable from ceiling rose to connector of fan complete all as directed by Engineer-in-Charge.
Taking down exhaust fans of any size/sweep after disconnecting the wire from existing ceiling rose and refixing the same after cleaning dust, oiling, greasing including providing flexible cable from ceiling rose to connector of fan complete all as directed by Engineer-in-Charge.
M & L for flame proof point wiring using approved colour coding as per IS with 1.5 sqmm two nos single core PVC insulated but unsheathed FRLS cable, 1100 volts grade, ISI-694 marked with multistranded copper conductor and earth continuity wire with similar 1.5 Sqmm cable (including connecting to earth dolly) drawn through heavy duty ISI marked ERW stove enamelled, steel conduit concealed in wall suitable for flame proof wiring, not less than 20mm dia with and including flame proof bends and elbows, couplers, bell mouth reducer , junction box all as per relevant IS and type tested/ approved by CMRI Dhanbad all as specified for One light point /power point/ fan point controlled by one no. FLP rotatory switch complete al as specified and directed by Engr-in-charge.
M & L in repair for submain wiring with approved colour coding as per IS with single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked drawn through through heavy duty ISI marked surface mounted ERW stove enamelled, steel conduit suitable for flame proof wiring, not less than 20mm dia with and including flame proof bends and elbows, couplers, bell mouth reducer, junction box all as per relevant IS all as specified complete for the following size:-
2 runs of 4 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor
2 runs of 2.5 Sqmm size main cable and one run of 2.5 Sqmm size earth continuity conductor
Taking down of existing flame proof tube light fittings from wall & refixing the same flame proof fitting at the same/other location including replacement of necessary polycarbonate LED tube 4 feet, 18/ 20W complete all as specified and directed by Engineer-in-Charge.
Taking down of existing flame proof midbay bulk head light fittings from false ceiling of shed No 22 (Gurth) & refixing the same flame proof fitting at the same location after necessary repair complete all as specified and directed by Engineer-in-Charge. Note: - Unsercviceable flame proof builkhead light fitting for replacement if any will be measured and paid seperately under item No 17.
S&F in repair new flame proof and weather proof Switch rotary type with termination box in LM6, 16A, single pole 250V suitable for hazardous locations of zone 1 & 2, Ex 'd' with relevant IS & IP65 protection complete all as specified and as directed.
S&F in repair new flame proof and weather proof Switch rotary type with termination box in LM6, 16A, double pole 250V suitable for hazardous locations of zone 1 & 2, Ex 'd' with relevant IS & IP65 protection complete all as specified and as directed.
Supply and fix in repair, knob as per OEM’s specification for switch flame proof rotary type, 16A single pole 250V, complete all as specified and directed.
S&F in repair new flame proof and weather proof Switch rotary type with termination box in LM6, 25A, double pole 250V suitable for hazardous locations of zone 1 & 2, Ex 'd' with relevant IS & IP65 protection complete all as specified and as directed.
S&F in repair new flameproof and weather proof Flame proof fan regulator for flame proof ceiling fans of size 48'' suitable for hazardous locations of zone 1 & 2, Ex 'd' with relevant IS & IP65 protection complete all as specified and as directed.
S&F in repair flameproof switch socket & plug combined in LM6 cable termination box in LM6, 16A,250V, 2P+earth for connection of 3 phase 415V rating equipment suitable upto 10 HP power connection complete all as specified and directed.
S&F in repair flameproof switch socket & plug combined in LM6 cable termination box in LM6, 32A, 250V, 4P+ earth for connection of 3 phase 415V rating equipment suitable upto 20 HP power connection complete all as specified and directed.
S&F in repair flexible steel conduit suitable for flame proof wiring, not less than 20mm dia all as per sample kept in GE Office.
S&F in repair CMRI Certified LED flame proof 1X16/20 W, tube light fixture, Recommended for ammunition shed, IP 65 protection complete with all accessories internally pre-wired complete all as specified and as directed Make: Crompton Greave Cat No. ExTN1LT8 - 16/20 or Equivalent in Sudhir/Shyam/Shakti.
S&F in repair CMRI certified LED Flame proof 2X16/20 W, Tuble light fixure, Recommended for ammunition shed, IP 65 protection complete with all accessories internally pre-wired complete all as specified and as directed. Make: Crompton Greave Cat No. EXTN2LT8-16/20 or eqeuivalent in Sudhir/Shyam/Shakti.
S&F in repair LED 60W Flame proof midbay bulk head light fitting properly earthed suitable for hazardous locations of zone 1 & 2, Ex 'd' with relevant IS & IP65 protection complete with all mounting attachements all as specified and directed Cat part No FWL 1315-60-CDL of Crompton or equivalent in Sudhir/Shyam/Shakti.
S&F in repair single phase flame proof wether proof Ceiling fan in cast aluminium LM6 of size upto 48 '' suitable for hazardous locations of zone 1 & 2, Ex 'd' with relevant IS & IP65 protection complete including taking down unserviceable ceiling fan and depositing MES store yard all as specified and as directed.
S&F in repair single phase flame proof Exhaust fan with louvers, of size 15", 1440 RPM including fixing as per standard complete suitable for hazardous locations of zone 1 & 2, Ex 'd' with relevant IS & IP65 protection complete including taking down unserviceable Exhaust fan and depositing MES store yard all as specified and as directed.
S&F in repair weather proof, flame proof distribution board approved by CMRI Dhanbad of cast aluminium alloy LM-6 MCB type TPN -4 way with 63 Amps TPN, rotory switch as incommer and MCB SP C Series 10 KA 6-32 Amps-12 nos as outgoing including taking down unserviceable DB all as specified and as dircted.
S&F in repair weather proof, flame proof distribution board approved by CMRI Dhanbad of cast aluminium alloy LM-6 MCB type SPN -8 way with 40 Amps SPN with rotory switch as incommer and MCB SP C Series 10 KA 6-32 Amps-7 nos with rotory switch as outgoing including taking down unserviceable DB all as specified and as dircted.
M&L for plate earthing with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth wirte 4 mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of equipment’s etc at the other end including 15 mm GI light grade protection pipe with all fittings from top of electrode to body of equipment fixed with iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 3 of SSR Part-1 including testing earth resistance and submitting test report to Engineer-in-Charge by the contractor complete all as specified & directed. Note :- (i) Earthing resistance required in earthing shall be less than 3.0 Ohms after completion of work. All earthing shall be tested by the contractor in presence of Engr-in-Charge. Test result shall be recorded and signed by the contractor and Engr – in- Charge. If contractor fail to achieve the above result the same shall be rectified by the contractor without any extra cost to Govt. The earthing result will be required maintaining up to end of defect liability period of one year and if any variation found in earthing result during defect liability period same will be intimated to the contractor by Engr-in-Charge and contractor shall rectify the same. The quoted rates shall be deemed to include for above said provision. (ii) Quoted rates shall be deemed to be included for earth wire with 15 mm dia protection pipe up to 7.5 length.
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Paragon Electrotechnics
M/s Vinod Yadav
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .