| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L1 | Accepted-AOC Stands Lowest | |
| 2 | L2₹14.0 L+₹1.6 L (13.4%)Rejected-AOC 612 MARSHALL HOUSE 612 MARSHALL HOUSE 33 1 NETAJI SUBHAS ROAD KOLKATA 700 001 DALHOUSIE KOLKATA WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-AOC Stands 2nd Lowest | |
| 3 | L3₹14.2 L+₹1.9 L (15.3%)Rejected-Finance | L3 | Rejected-Finance Stands 3rd Lowest |
Tender Value
Refer Docs
EMD Value
₹25,634
Closing Date
7 Dec 2020, 1:30 pmClosed
Executive Engineer
Office of the Executive Engineer, Purba Medinipur Electrical Division, P.W.Dte, Tamluk, Hospital More
Electrical Installation work at proposed Nursing training School with Hostel at Purba Medinipur District Hopital, Tamluk-----SITC of Fire detection and annunciation system
2020_WBPWD_302676_1
PWD/EE/PMED/eNIQ-11/20-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Tamluk
Please refer Tender documents.
5 documents required · 5 mandatory
₹25,634
Tamluk
21 Jan 2021
2 Nov 2020
9 Dec 2020
2 Nov 2020
7 Dec 2020
2 Nov 2020
1 Dec 2020
Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector (VDS /EN/ UL / FM / ULC approved) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detector sensor with decentralised intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per corresponding standard. (Note : detectors without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) No. of addressable devices in a group will be as per latest recommended Indian/International standards) .(Approved make : Esser/ Cerberus Pro / Secutron/ Notifer / Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (VDS / EN / UL / FM / ULC approved) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) (Approved make : Esser/ Cerberus Pro / Secutron / Notifer / Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (VDS / EN / UL / FM / ULC approved) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) (Approved make : Esser/ Cerberus Pro / Secutron / Notifer / Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton)
Supply, Installation, Testing & Commissioning of Addressable loop / external powered Hooter (sound output of minimum 90db) cum strobe (strength of light 10cd) complete with inbuilt isolator & IP 42 base (VDS /EN / UL / FM / ULC approved) (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for group of addressable devices.) (Approved make : Esser / Cerberus Pro / Secutron / Notifer / Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton)
Supply, Installation, Testing & Commissioning of LED type Response Indicator (VDS / EN / UL / FM / ULC approved) including connections etc. complete in all respect. (Approved make : Esser / Cerberus Pro / Secutron /Notifer / Edward / Bosch / Apollo / System Sensor/Jhonson Control /Securiton)
Supply, Installation, Testing & Commissioning of Microprocessor based Intelligent Addressable Fire Alarm control Panel (VDS / EN /UL / FM / ULC approved) having expandable and fully networkable features suitable for handling all the detectors and devices for this project. It can be suitably configured according to the OEM loop capacity (each loop shall have 80% loaded and 20% spare capacity). The panel shall have colour LCD TFT display of min 5" Screen with Touch Sensitive Keyboard. Addressability of the Intelligent Panel shall be soft addressed type . The Intelligent panel shall be able to give pin point location of all fire/fault conditions, considering Network Card in the Panel along with necessary accessories. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The panel should be able to store sufficient numbers of log events in its memory as per applicable Indian/International standards. All the Intelligent Detectors as applicable for various areas based on application and design considerations shall be sitting on Loop along with Loop powered Alarm Devices; MCPs and Input /output Modules. NOTE: The panel shall have in-built rectifier, Loop cards,provision for external & internal printer (if required ), LCD unit to indicate Fire/Fault Signal with address & analog output, complete in all respects, in built surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for minimum 30 minutes during Emargency condition, with integral automatic battery charger complete as required. The panel shall have extra loop card to serve as stand by in case of burntout or malfunctioning of any operating loop cards. The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system and BMS( RS 485 )The system must be preloaded with licenced software.( Approved Make: Esser /Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls /Securiton ).
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / RR Kabel/ Polycab) with 20mm NB PVC rigid conduit pipe on the surface of the wall. (Make : Precission-Medium)
TESTS: 1.The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. NOTE : The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS: 2189 3. NFPA -70 National Electric Code 4. NFPA - 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation.
Sandeep Tradex Private Limited
MAGNUM SAFETY INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .