| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical P NO 18 19 203 204 ADITYA COMPLEX NANGAL RAI NANGAL RAI NEW DELHI DELHI 110046 UDYAM DL 10 0004501 | NEW DELHI | DELHI | 110046 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹23.8 L
EMD Value
₹47,600
Closing Date
26 Feb 2026, 11:00 amClosed
EEE/CLZ
EEE/CLZ
Provision of CCTV Cameras in KCC Block, Emergency and trial ward with 5 years CAMC in RBIPMT Hospital
2026_MCD_267581_1
EEE/CLZ/TC/2025-26/61.1
Open Tender
Electrical Works
Percentage
60 days
EEE/CLZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹47,600
6 Apr 2026
17 Feb 2026
26 Feb 2026
17 Feb 2026
26 Feb 2026
17 Feb 2026
Part A SITC of 8 MP fixed lens Dome IP Camera with following specifications:- Image Sensor: 1/3 8MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate: 1-20 fps or better ** Lens: 2.8mm fixed Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (2650x1440) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE, DDNS, IEEE802.1X IR Range: Minimum 25m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL
SITC of 8MP fixed lens BULLET IP Camera with following specifications:- Image Sensor: 1/3 8MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better ** Shutter Speed:1/3 – 1/100,000 s Frame Rate: 1-20 fps or better ** Lens: 2.8mm fixed Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (2650x1440) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE, DDNS, IEEE802.1X IR Range: Minimum 25m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL
SITC of 16 channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better** Network Throughput :160Mbps or better** USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 1 SATA port suitable for 6TB each Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL
SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch
SITC of 10 TB surveillance HDD
SITC of full HD LED Monitor,42 INCHES complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 300 NITS min. Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz at site with connections and along with all accessories etc. complete as required.
SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 3KVA
SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.6 U
SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Fabrication, supply & erection of 5.0 mtr height, minimum 3 mm thick, bottom dia of 130 mm & top dia of 70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel i/c providing and fixing DIN channel of suitable length, 6 Amp. SPMCB 'C' characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole. Galvanization as per relevant IS code etc as required.
Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DWC HDPE for cable entry and exit as required for 3 m and 5 mtr pole.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Part B Comprehensive Annual Maintenance contract of Existing Cameras inclusive all of above ( CCTV cameras, NVR, complete with all accessories ) all after ONE year of defect liability period i/c replacement of damaged item/part/system with all accessories, spare parts, software, hardware etc as required. 2nd year
Comprehensive Annual Maintenance contract of Existing Cameras inclusive all of above ( CCTV cameras, NVR, complete with all accessories ) all after ONE year of defect liability period i/c replacement of damaged item/part/system with all accessories, spare parts, software, hardware etc as required.3rd year
Comprehensive Annual Maintenance contract of Existing Cameras inclusive all of above ( CCTV cameras, NVR, complete with all accessories ) all after ONE year of defect liability period i/c replacement of damaged item/part/system with all accessories, spare parts, software, hardware etc as required. 4th year
Comprehensive Annual Maintenance contract of Existing Cameras inclusive all of above ( CCTV cameras, NVR, complete with all accessories ) all after ONE year of defect liability period i/c replacement of damaged item/part/system with all accessories, spare parts, software, hardware etc as required. 5th Year
Comprehensive Annual Maintenance contract of Existing Cameras inclusive all of above ( CCTV cameras, NVR, complete with all accessories ) all after ONE year of defect liability period i/c replacement of damaged item/part/system with all accessories, spare parts, software, hardware etc as required. 6th Year
stage.html
html • 0.03 MB
cancelled_1.pdf
pdf • 0.30 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tender_Condition_CCTV.pdf
Tender Documents • 0.17 MB
MCD_GCC_Circulars_2025.pdf
Tender Documents • 12.97 MB
BOQ_311150.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .