| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC | L1 | Accepted-AOC STANDS L1 | |
| 2 | L2₹1.9 L+₹8,140 (4.47%)Rejected-Finance | L2 | Rejected-Finance STANDS L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical pqc not qualified |
Tender Value
₹1.8 L
EMD Value
₹3,600
Closing Date
19 Oct 2019, 6:00 pmClosed
OMCIII SEIII BTPS OBRA SONEBHADRA
OFFICE OF OMCIII SEIII BTPS OBRA SONEBHADRA
Rewinding Ovehauling Testing and Commissioning of RV and Exhaust Fan Motors of 5 into 200 MW Units BTPS Obra
2019_RVUNL_388846_1
T12 OMCIII EMDIII BTPS 2019 20
Open Tender
Electrical Works
Lump-sum
365 days
BTPS OBRA SONEBHADRA
Please refer Tender documents.
4 documents required · 4 mandatory
₹296
Dy CAO CFA and BO BTPS OBRA SONEBHADRA
₹3,600
2 Apr 2020
4 Oct 2019
22 Oct 2019
4 Oct 2019
19 Oct 2019
4 Oct 2019
4 Oct 2019 - 19 Oct 2019
Amount
PART A___Following works are to be carried out on RV & Exhaust Fan of 5x200 MW Units: Dismantling of RV & Exhaust Fans from place of mounting on wall/roof, shifting to staff cabin, removing fan blade, cleaning them, shifting the burnt motor to the workshop of bidder, rewinding, testing, assy. of fan blades and mounting on its original/ place. 440V, 3phase, 50Hz, 2.2KW, 5Amp, 950rpm
440V, 3phase, 50Hz, 1.1KW, 3.1 Amp, 910rpm
440V, 3phase, 50Hz, 1.5KW, 3.6 Amp, 1400rpm
440V, 3phase, 50Hz, 0.5KW, 1400rpm
440V, 3phase, 50Hz, 0.37KW, 1.2 Amp, 905rpm
440V, 3phase, 50Hz, 0.18KW, 1400rpm
Repairing of damaged slot portion of fan motors by staggering the core. 440V, 3phase, 50Hz, 2.2KW, 5Amp, 950rpm
440V, 3phase, 50Hz, 1.1KW, 3.1 Amp, 910rpm
440V, 3phase, 50Hz, 1.5KW, 3.6 Amp, 1400rpm
440V, 3phase, 50Hz, 0.5kW,1400rpm
440V, 3phase, 50Hz, 0.37KW, 1.2 Amp, 905rpm
440V, 3phase, 50Hz, 0.18KW, 1400rpm
Repairing of bearing housing of fan motor 440V, 3phase, 50Hz, 2.2KW, 5Amp, 950rpm
440V, 3phase, 50Hz, 1.1KW, 3.1 Amp, 910rpm
440V, 3phase, 50Hz, 1.5KW, 3.6 Amp, 1400rpm
440V, 3phase, 50Hz, 0.5KW, 1400rpm
440V, 3phase, 50Hz, 0.37KW, 1.2 Amp, 905rpm
440V, 3phase, 50Hz, 0.18KW, 1400rpm
Part-B_Dismantling of RV & Exhaust Fans from place of mounting on wall/roof, removing fan blade, cleaning them, overhauling & testing, assy. of fan blades and mounting on its original place. R.V. FAN (1.5KW) in T.G. hall 3x200MW,
R.V. FAN (2.2KW) in T.G. hall 2x200MW,
R.V. FAN, 1.1KW in D.G. Set Room,
R.V. FAN, 1.1KW in Compressor House
R.V. FAN,0.37KW in C.W. Pump House
R.V. FAN, 1.5KW in W.T.P.
EXHAUST FAN: Exhaust Fan in S/G room-9th unit to 13th unit, A.C. Plant, Battery Charger & Battery room
Exhaust Fan in Mechanical Workshop & Compressor room
Exhaust Fan in W.T.P., BTPS
Exhaust Fan in Boiler MCC Room, Offices a t 9M level.
PART-C Dismantling of RV Fan (1.5KW) from the place of mounting on roof, frame repairing, blade repairing by way of Cutting/welding & belt replacement, overhauling, mounting & commissioning to its original place. Minor civil work included in the work.
Dismantling of Exhaust Fan from the place of mounting on wall, frame repairing, blade repairing by way of Cutting/welding & belt replacement, overhauling, mounting & commissioning to its original place. Minor civil work included in the work.
Ashoka And Company
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .