| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.9 L+₹2,195 (0.11%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹23.0 L+₹2.1 L (10.3%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹23.3 L+₹2.5 L (11.9%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹23.6 L+₹2.8 L (13.3%)Rejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Jul 2023, 6:00 pmClosed
GE CENTRAL BANGALORE
ASC CENTRE AND COLLEGE AGRAM POST BANGALORE 560007
REPAIR MAINT OF INTERNAL WIRING SUB MAIN WIRING MCCBs LIGHT FITTINGS WITH OTHER INTERNAL WIRING AT OFFRs Ors MD ACCN AT 70 MAJ NGV 100 MAP AND 598 OR MD ACCN AND OTHER CONNECTED AREA UNDER GE CENTRAL BANGALORE
2023_MES_603012_1
8321E
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE CENTRAL BANGALORE
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE CENTRAL BANGALORE
₹60,000
Yes
22 Sept 2023
13 Jun 2023
5 Jul 2023
13 Jun 2023
3 Jul 2023
21 Jun 2023
13 Jun 2023 - 20 Jun 2023
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing taken down materials to a place where ordered for crediting including making good disturbed surfaces of walls, floors, etc to match with the existing surface complete all as directed..
M&L for point wiring for one light/ ceilig fan point / bell point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
All as per item No. 2 above but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch socket on independent board -do-
All as per item No. 2 here-in-above, but for 5 Amp (2/ 3 pin), switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 2 here-in-above, but size of cable 4 Sq.mm for 15 Amp and 5 Amp (3 pin) combined, switch socket in independent board with earth wire 4 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
M&L for point wiring for one light/ ceilig fan point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including 20 mm wide PVC Casing / caping with all fittings such as tee, bends, etc all as per IS, terminated in & including new MS terminal boxes fixed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed.
All as per item No. 6 above but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch socket on independent board -do-
All as per item No. 6 above but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch socket on same board with other switches -do-
All as per item No. 6 here-in-above, but size of cable 4 Sq.mm for 15 Amp and 5 Amp (3 pin) combined, switch socket in independent board with earth wire 4 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
Supply and fix Switch piano, flush button single pole, 5 Amps one way.
Supply and fix bell push, flush button single pole, 5 Amps one way.
Supply and fix Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose
Supply and fix Switch socket combination flush type 6/16 Amps 3/3 pin universal multipurpose
Supply and fix Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan.
Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks.
Supply and fix in repair Switch piano, flush button single pole, 5 Amps one way.
Supply and fix in repair Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose
Supply and fix in repair Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose
Supply and fix in repairs modular switch 1 way 10A,1 module Make : Anchor/Havell/Polycab
Supply and fix in repairs modular switch 1 way 20A,1 module Make : Anchor/Havell/Polycab
Supply and fix in repairs socket, 10A-2/3 pin combined 2 modules Make : Anchor/Havell/Polycab
Supply and fix in repairs socket, 16A/16A-2/3 pin combined 2 modules Make : Anchor/Havell/Polycab
Supply and fix in repairs moduler fan Requlator, 120 W-2 modules
Supply and fix in repair Door bell electronic, music type, 230 volt AC. Make : Anchor/Havell/Polycab
Supply and fix in repair Fan capacitor 2.5/3.15 mfd suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Havell/Polycab
Supply and fix in repair Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan.
Taking down existing light fittings fixed in any description and S&F new 10 Watt , 6000K, 230 Volt, LED batten THD<10% on fulll load , SP 2.5KV LED efficiency 135 lum/w with aluminium extruded channel powder coated with diffuse with electronic driver complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. . Make : Havells/wipro/surya/ Philips
Taking down existing light fittings fixed in any description and S&F new 20 Watt , 6000K, 230 Volt, 4ft Batten surface and wall mounted LED batten THD<10% on fulll load , SP 2.5KV LED efficiency 135 lum/w with aluminium extruded channel powder coated with diffuse with electronic driver complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. . Make : Havells/wipro/surya/ Philips
Taking down existing light fittings fixed in any description S&F new security light light fittings 1x 25 Watt LED street light with New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with all accessories and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed.Make : Havells/wipro/surya
S&F in repair security light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 32mm X 5 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole complete all as specified and directed.
Supply and fix in repair Sheet metal enclosure (ISI marked) distribution board TPN, 415 volts, 4 way horizontal type double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified.
Supply and fix in repair Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 4 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
All as per item No 32 here-in before but SPN 8 ways DB.
Supply and fix in repair MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity
Fixing only MCB single pole 6 to 32 Amps any capacity (Servicable MCB received from item No 31 , 32 & 33 here-in-above)
Supply and fix in repair MCB single pole & neutral 32 Amps 240 volts, C series,10 kA rupturing capacity
Supply and fix in repair MCB Tripple pole & neutral 40 to 100 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified.
Taking down old existing sub main wiring and provide new submain wiring with 2 runs of 4 Sqmm single core PVC insulated, unsheathed, multi stranded copper conductor and one single core 4 Sqmm PVC insulated , unsheathed , multi stranded copper cable as earthing lead as per IS : 694 / 1990 drawn through and including non-metallic PVC rigid conduit/casing caping of size as ordered in walls / ceilings etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 4 Sqmm cable , one run 4 Sqmm cable and one run of PVC Conduit /Casing caping shall be measured as one unit length) .
All as per item No 38 here-in-above but 2 runs with 6 Sqmm single core cable and 6 Sqmm single core as earth contunity wire -do- . (Note :- 2 runs 6 Sqmm cable , one run 6 Sqmm cable and one run of PVC Conduit/Casing caping shall be measured as one unit length)
S & F in repair ballast electronic type for 1x28 Watt FTL/CFL complete all as directed. Make Havells/Bajaj/Crompton
S & F in repair florecsent tube rod 1x28 Watt, 6000K, high efficiency /high out put complete all as directed. Make Havells/Bajaj/Crompton
M&L for taking down and dismantling of ceiling fan 1200mm/1400mm sweep 230 Volt 50 C/S AC of any make or model by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition with & including replacing the bearing with similar type of exisitng one, worn out screws of the cover, split pin, twin core flexible copper wire of size 23/0.0076, locking nuts & machine screws with spring washer for ceiling fan blades, oiling and greasing etc, finally painting the ceiling fan with one coat of spray painting with white DUCO Paint & lettering & Numbering the same as per existing ,reassembling & testing the fan complete all as directed. Note :- (i) Capacitor shall be measured and paid for separately under relevant items as “Supply only”. Rewinding shall also be measured & paid for separately (ii) Quoted rate is deemed to be inclusive of painting .
M&L for rewinding of ceiling fan of size 1200mm/1400mm sweep, 230 volt, 50 C/S, AC by removing of burnt winding from stator and rewinding the same with super enamelled copper winding wire of same gauge, same weight & turns including varnishing of winding & reassembling complete all as directed.
M&L for taking down and dismantling of Exhaust fan 300mm/450mm sweep 230 Volt 50 C/S AC of any make or model by opening the cover, separating rotor and stator assembly, locating the fault and making the exhaust fan fully in serviceable condition with & including replacing the bearing with similar type of exisitng one , worn out screws of the cover, twin core flexible copper wire of size 23/0.0076, rubber pad for legs, oiling and greasing etc, finally paint the exhaust fan with one coat of spray painting with white DUCO Paint & lettering & Numbering the same as per existing, reassembling & testing the fan complete all as directed. Note :- (i) Spare Parts/accessories found unserviceable except bearing which are required to be replaced shall be measured and paid for separately under relevant items as “Supply only”. Rewinding shall also be measured & paid for separately(ii) Quoted rate is deemed to be inclusive of painting.
M&L for rewinding of exhaust fan of size 300mm sweep, 230 volt, 50 C/S, AC by removing of burnt winding from stator and rewinding the same with super enamelled copper winding wire of same gauge, same weight & turns including varnishing of winding & reassembling complete all as directed.
S&F fan capacitor 2.5/ 3.15 /1.85 mfd oil filled for the ceiling fans/exhaust fans of approved make and ISI marked, fixed complete all as directed. Make : Tibcon/ Sharda/Epcos/Kail/Crompton
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized iron earth wire 4 mm dia as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted to earth plate at one end and other end of earth wire connected to Pole / transformer / GOD / Panel / equipment body / test point /Bldg DB , GI earth wire encased in and including 15mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including taking out old earthing.. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner
RAMSON TRADERS
Chandana Enterprises
GS TRADERS
GKR and CO
RRK PROJECTS
SREE VARU ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .