| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.0 L+₹1.0 L (4.36%)Rejected-Finance SHOP NO 107 MOHAN SINGH PLACE NEW DELHI 110001 | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹28.1 L+₹4.1 L (17.3%)Rejected-Finance 256 MUNDHELA KHURD NEW DELHI 73 | L3 | Rejected-Finance L3 |
Tender Value
₹28.7 L
EMD Value
₹60,300
Closing Date
11 Mar 2024, 10:45 amClosed
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony, New Delhi 110024
Improvement of street lighting arrangement in Aali Village in Ward No 186 under Central Zone
2024_SDMC_189318_1
EE(Elect.)/CNZ/2023-24/76-01
Open Tender
Electrical Works
Item Rate
120 days
Ward no186
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹60,300
11 Jul 2025
2 Mar 2024
11 Mar 2024
2 Mar 2024
11 Mar 2024
2 Mar 2024
Amount
Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required .(a) 3x1.5 sqmm
Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required .(a) 5x1.5 sqmm
Earthing with GI earth pipe 4.5 metre long ,40 mm dia including accessories,and providing massonary encloser with cover plate having locking arrangement and watering pipe etc.with charcoal /coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC /HUME/METAL pipe as required. Up to 35 sqmm
S/L of following size DWC HDPE Pipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,part II complete with fitting and cutting ,jointing etc .direct in ground (75 cm below ground level )including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ).
Supply of XLPE insulated, PVC sheathed Al. Conductor Armoured cable 1.1 KV grade confirming to IS-7098 of following Size (a) 2 X 6 Sq. mm
Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circufrential weld. It should also included accessories for High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries luminaries symmitrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L)X1m (W)X2m deep i/c excavation of earth i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -2100 mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of 4 nos foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for high mast considering. The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c, 4Nos S.P MCB, 63Amp .DP Isolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. galvanized as per relevant IS.
Supply and Fabrication of Pole Protection system made up 8 SWG Steel wire mesh of size 25mm X 75mm rectangular with 50mm X 50mm X 6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc.
Fabrication,supply & errection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate hight from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4 mm thick of suitable length and having suitable size tapped holes as reqd., terminal block suitable for 25 sqmm conductor-4 nos & shorting links on DIN channel i/c pdg and fixing DIN channel of suitable lenth,6 amps SP MCB "c" characteristics,earth stud,cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.( a) 5.o mtr. hight,3 mm thick,bottom dia of 130 mm & top dia of 70 mm, base plate of size 225 mm x 225 mm x 12 mm thick.
Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L)x450 mm wide and 1000 deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long (approx)-8 nos . and reinforcement of cold twisted bars of 8 mm dia 1400 mm (approx) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 no. foundation bolts of size 16 mm dia ,600 mm long, J type i/c 2 nos. template anchor plates of size 225 mm X 225 mm X 3 mm and providing 63mm dia DCW, HDPE for cable entry and exit as required for 5 mtr pole.
Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap and 1000 mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250 mm long galvanized top tube with cap and 1000 mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
Providing and Laying of HDPE pipe of 40 mm outer dia with PN 4 rating by Hand moling/ Mannual method confirming to IS 4984.
Aviadu energy and infra pvt ltd
DEV ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .