Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹4.5 L+₹70,290 (18.3%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹8,000
Closing Date
24 Oct 2020, 6:00 pmClosed
AGE (I) (AF)Chimney Hills, Bangalore
Asst Garrison Engineer I AF Chimney Hills ChikkbanavaraPost Bangalore, PIN- 560 090
PROVISION OF HEAT AND SMOKE DETECTOR AND FIRE ALARM SYSTEM AT 75 KVA AND 150 KVA UPS ROOM AT OPS/RADAR COMPLEX AT AF STATION CHIMNEY HILLS
2020_MES_368801_2
8381/E8
Open Tender
Civil Works
Item Rate
90 days
AGE (I) (AF)Chimney Hills, Bangalore
As per tender documents
8 documents required · 8 mandatory
₹300
AGE (I) (AF)Chimney Hills, Bangalore
₹8,000
Yes
20 Jan 2021
9 Oct 2020
26 Oct 2020
9 Oct 2020
24 Oct 2020
12 Oct 2020
9 Oct 2020 - 10 Oct 2020
Amount
Supply and fix conventional photoelectric smoke detector (above false ceiling), fully compatible with the majority of existing conventional systems and a third terminal provides an integral remote indicator output complete all as specified and directed. Make : CEASE FIRE or equivalent in Honeywell/UNIVERSAL (RAVEL) / EDWARDS as approved by Accepting Officer
Supply and fix conventional photoelectric smoke detector (below false ceiling), fully compatible with the majority of existing conventional systems and a third terminal provides an integral remote indicator output complete all as specified and directed. Make : CEASE FIRE or equivalent in Honeywell/UNIVERSAL (RAVEL) / EDWARDS as approved by Accepting Officer
Supply and fix conventional rate of rise heat detector, incorporating a 60°C fixed temperature element, the thermistor and line arising circuit to provide an accurate linear response heat detector and a third terminal to provide integral remote indicator output complete all as specified and directed. Make : CEASE FIRE or equivalent in Honeywell as approved by Accepting Officer
Supply and fix Standard mounting base for detectors complete all as specified and directed. Make : CEASE FIRE or equivalent in Honeywell/UNIVERSAL (RAVEL) / EDWARDS as approved by Accepting Officer
Supply and fix response indicator to provide the indication of alarm activated condition of detector installed in a concealed enclosure or not visible directly complete all as specified and directed. Make : CEASE FIRE or equivalent in Honeywell/UNIVERSAL (RAVEL) / EDWARDS as approved by Accepting officer
Supply and fix conventional manual call point based upon the industry standard KAC world series housing. The unit can support either a ‘Frangible Glass element or a ‘Non Frangible Plastic’ element. Supplied complete with SRBACKBOX for surface mounting complete all as specified and directed. Make : CEASE FIRE or equivalent in Honeywell as approved by Accepting officer
Supply and fix electronic conventional sounder which can be installed internally complete all as specified and directed. Make : EASE FIRE or equivalent in Honeywell/UNIVERSAL (RAVEL) / EDWARDS as approved by Accepting Officer
Supply and fix Fire extinguisher ABC powder ceiling mounted type 5 KG, Auto discharge mechanism, should have Quartzoid bulb which bursts when the temperature increases beyond the limit of 68 deg C, Red Quartzoid bulb with the rating of 68 deg C, Applicable on Class A,B,C and electrically started Fire. EN PED approved and CE marked Make : CEASE FIRE or equivalent in Honeywell or any other approved make as approved by Accepting officer
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified. Note : A deduction of 10% shall be made from total computed volume of filling to cater for bulkage irrespective of machinery used for ramming.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as directed.
Supply, laying, jointing, testing and commissiong PVC insulated, PVC sheathed cable, galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor 1100 volts grade confirming to IS, laid in trenches, ducts, passing through pipes or fixed to wall with suitable clamps/saddles etc., including all accessories and connecting of size 2 Core x 1.5 Sqmm complete all as specified and as directed.
Supply and laying common burnt clay, bricks, sub class 'B' designation 75 and laid in trenches for cable protection as specified and directed.
Supply and laying galvanised steel pipe 25mm bore dia light grade including all fittings complete laid in trenches or in floor, for road crossing/fixed on wall/on pole for protection of LT UG cables all as specified and as directed
Labour only for riddled earth done through by riddling of excavated soil and spreading the same in layers, overall thickness 23 cm, below and upper part of the LT UG cable for cable cushioning all as per clause 19.75 of SSR part -I
H S S ENGINEERS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .