| 1 | L1₹4.3 CrAccepted-AOC NO 8 109 1 ARASAMARATHU KAADU MUTHUNAICKENPATTI SEMMAN KODAL POST OMALUR TALUK SALEM DISTRICT 636 304 | SALEM | TAMIL NADU | 636304 | ₹4.3 Cr Quoted ₹4.4 Cr | L1 | Accepted-AOC Lowest Tenderer Accepted |
| 2 | L1₹4.5 CrRejected-Finance NO 6 173 2 EARIKARAI KALAPARAPATTY PO SALEM SOUTH TALUK VEMBADITHALAM VIA SALEM 637504 | SALEM | TAMIL NADU | 637504 | ₹4.5 Cr | L1 | Rejected-Finance Reject |
Tender Value
₹3.6 Cr
EMD Value
₹1.9 L
Closing Date
30 May 2023, 5:00 pmClosed
Chief Engineer
Fishing Harbour Project Circle , Integrated office Complex, Animal Husbandry and Fisheries and Fishermen Welfare Department, Nandanam, Chennai 35,
Establishment of Fish Landing Centre at Tsunami Nagar and Akkaraigori Villages in Cuddalore District
2023_AHDF_311259_1
08- 02 /DB/F.114 N/2023
Open Tender
Civil Works
Lump-sum
270 days
Akkaraigori Village
As mentioned in Prequalification document
4 documents required · 4 mandatory
₹0
₹1.9 L
5 Oct 2023
5 May 2023
31 May 2023
5 May 2023
30 May 2023
5 May 2023
Amount
Earthwork Excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth with in the compound in places shown by the departmental officers with an initial lead of 10mts and initial lift of 2mts and clearing and levelling the site etc., Complete complying with standard specifications.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying and filling in foundation, basement, etc with filling M.sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:4:8 (One cement, Four sand and Eight hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
For Plain surfaces such as RCC slab, Beam, Bed Block, waist slab, landing slab, lintel etc.,
For column footing plinth beam staircase steps, piers raft beam raft slab etc.,
For square or rectangular column, boxing, sunshade etc.,
For Vertical surfaces such as sunshade boxing, vertical drops, facia for sunshade, canopy facia and other vertical walls etc.,
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and basement
For Ground floor up to 4.50m height
Supplying, fabricating and placing in position of steel reinforcement using MS (or) RTS rods for all RCC item of works including cost and conveyance , straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design etc complete and as directed by the departmental officers.
Brick work in following Cement Mortar using best quality Fly ash bricks of size 23x11x7cm for foundation and basement including curing etc.,complete complying with standard specification.
For Foundation and basement
For Ground floor up to 4.50m height
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Painting two coats of newly plastered wall surface with ready mixed Plastic emulsion paint of first class quality and of approved colour over a priming coat including preparing the surface clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on work).
Weathering course using best quality of broken brick jelly of 20mm gauge in pure slacked lime (no sand to be added) the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer and consolidated to the required finished thickness and slope by beating the concrete with wooden beater of approved pattern and keeping the surface constantly wet by sprinkling lime jaggery water etc., complete complying with standard specification and as directed by the departmental officers.
Finishing the top of roof with one course of pressed tiles of size 23×23×2cm of approved quality laid in cement mortar 1:3 (One cement and three sand) 12mm thick mixed with water proofing compound (confirming to Indian standard specification) 2% by weight of cement used and pointed with the same mortar including mixing of red oxide etc., complete complying with standard specification and as directed by thedepartmental officers.
Paving the floor with pre polished granite slab (Ruby Red/Raw Silk) of thickness 18mm to 20mm of best quality and approved variety and size not less than 1200x600mm confirming to ISI specification, in cement mortar 1:1 (One cement and one P.sand) 20mm thick and pointed with same coloured cement neatly etc., complete complying with standard specification.
Supplying and fixing in position best approved of ISI quality PVC rain water down fall pipes of 110mm dia having a working pressure of 4 kg / sq.cm including cost of necessary PVC shoe, PVC bend, C.I. gratings of required dia. and special clamps, brass screws, nails etc., and fixing of cast iron gratings at juction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cost of removable iron grating. The PVC pipe shall be fixed on wall with special type of clamps. Special type "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0M pipe length complying with standard specification. ( Above Ground Level)
Wiring with 2x1.5 sqm (22/0.3) PVC insulated unsheathed SC.Cu Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A F.T. switch inflush with wall, covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (For electronic regulator) (5 Points per Coil).
Supplying and fixing of twin box type 4" 40W flu fitting complete with copper choke and condensor, with TW round block on wall or ceiling with tubes and PVC unsheathed Copper leads from terminals to the fitting.
Supply and fixing of 1200 mm (48") sweep AC ceiling fan complete with stepped electronic 300W regulator, with 1 metre down rod with fan clamp with side plates and cross arm of size 450 mm (18").
Supply and laying of 4 x 6 Sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling good.
Supply and fixing of 5A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch on suitable TW box connection complete.
Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch on suitable TW box connection complete.
PLUG AND SOCKETS IN SHEET STEEL ENCLOSURE WITHOUT MCBs (BWD
20A Single Pole
20A Double Pole
VERTICAL THREE PHASE DISTRIBUTION BOARD WITH MCBS 4 way / 8 way / 12 way vertical TPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating One No. 4 pole incoming MCB / Isolator and another separate 4 way provision for accommodating One No. 4 pole ELCB / RCD with label holder and provisions (4 ways 3 phase DB No. of ways incomer MCB / Isolator - 4 No. of ways incomer ELCB / RCD - 4 No. of outgoings ways - 12)
Sub Total Amount for above all items (excluding GST)
GST 18% for above SubTotal Amount
V P M PROJECTS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .