Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L1 | Accepted-AOC beingL1 | |
| 2 | L2₹7.0 L+₹65,571 (10.3%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L2 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 3 | L3₹7.5 L+₹1.1 L (17.7%)Rejected-Finance 7 345 C 1 AERO NAGAR KANGEYAMPALAYAM KADAMPADI SULUR COIMBATORE TAMIL NADU 641401 | COIMBATORE | TAMIL NADU | 641401 | L3 | Rejected-Finance quoted amount is higher than 1st lowest |
Tender Value
₹7.8 L
EMD Value
₹15,600
Closing Date
20 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF Coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
MAINTENANCE AND REPAIRS TO COOLING APPLIANCES, VOLTAGE STABILIZERS AND CONNECTED ITEMS AT AFAC UNDER AGE (I) (AF) COIMBATORE
2023_MES_576220_1
8887_E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
COIMBATORE
Class-E category-a(i) or c (i) (see NIT for detail)
7 documents required · 7 mandatory
₹500
AGE I AF Coimbatore
₹15,600
Yes
4 Mar 2023
20 Jan 2023
22 Feb 2023
20 Jan 2023
20 Feb 2023
6 Feb 2023
20 Jan 2023 - 13 Feb 2023
Amount
Attending day to day complaints pertains to cooling appliances of any capacity/make/size/type for Split ACs, refrigerators, water coolers, Deep freezers of any capacity, by deploying one High skilled mechanic and one helper for, identifying/rectifiying faults, repairing / replacing unserviceable parts, Servicing and maintenance of cooling appliances including cleaning of indoor/outdoor units, cleaning of Air filter and air outlet grills with a soft dry cloth, cleaning of air inlet (use a vacuum cleaner to remove dust from the air inlet), cooling coil , condenser coil (using water jet pump), oiling to fan motor, cleaning of compressor etc, fan motor/blower motor, groove mat rubber, cleaning of the storage tank of water coolers with liquid soap solution and flushing with potable water, wiping with dry cloth,replacing the drain pipe (PVC ) and overflow pipe(PVC) checking/dressing up of electrical wirings/ circuits etc wherever necessary to keep the cooling appliances in good working condition including top up of refrigerant gas up to required pressure all as specified and directed by the Engr-in-charge. Notes: (i) Spare parts required for replacement shall be meauseured and paid for seperately under respective items under supply only items. (ii) The contractor’s refrigerator mech/Technician alongwith T&P should be made available immediately when ever his services are required to rectify any nature of fault. (iii) Contractor/his Technician has to obtain complaints from MES office at 0900 Hrs daily and complaint should be rectfied within 24 Hrs and not more than 72 Hrs, If contractor fails to rectify complaint within 72 Hrs then the amount recovered shall be double of quoted rate for per complaint. (iv) Contractor has to provide register for maintaining records of maintenance carried out and it is the responsibility of the contractor to get the signature of user & JE/Engineer-in-charge on the register for carrying out maintenance. The register shall be maintained and to be produced to Enginner-in-Charge whenever demanded. (v) Minor parts such as nut , bolts, washers, PVC drain pipe, Cleaning shop, oiling, greasing, top up refrigerant gas etc shall deemed to be included in rate quoted by the contractor and nothing shall be paid on this account.
M&L for removing the water cooler of capacity 40/80 ltrs from location after disconnecting electric and water supply connection, transporting to local workshop for repair to corroded body by tinkering with suitable thickness sheet as existing, cutting the bottom plate, leg stand and other deteriorated/corroded portion and welding new plate with new legs, spray painting water cooler complete with one coat of primer and two coats of paint of approved shade including replacement of unserviceable tap, top cover, beeding, hinges, PVC connector and transporting back to AGE E/M store yard /previous location complete all as specified and directed by Engr-in- Charge.
M & L for shifting the Refrigerator of capacity 165/180 ltrs from AGE E/M store yard/installed location/position to local workshop for repair to body by tinkering with suitable thickness sheet as existing, spray painting the refrigerator complete with two coat of synthetic enamel paint of existing colour over one coat of primer, including replacement of broken legs, tray, hinges, door beeding, handle and transporting back to AGE E/M store yard /previous location complete all as specified and directed by Engr-in- Charge.
All as per item No. 03 above but of capacity 286/310 ltrs all as specified and directed
M & L for shifting the Deep freezer of capacity 200/320/425 ltrs form AGE E/M store yard/installed location/ position to local workshop for repair to body by tinkering with suitable thickness sheet as existing ,spray painting of deep freezer complete with two coat of synthetic enamel paint of existing colors over one coat of primer/red oxide including replacement of broken legs , hinges, complete with top beeding ,inside puff insulation and transporting back to AGE E/M store yard/previous location complete all as specified and directed by Engr-in- Charge.
M & L for taking down carefully the Split A/C outdoor unit of 1.0/1.5/2.0/3.0 TR from installed location after disconnecting the electrical connection and transporting to local workshop for repair to corroded body by tinkering with suitable thickness sheet as existing for side top and (3mm MS plate) at bottom of AC including, painting with 2 coats of anti corrosive paint of existing colour over a coat of red oxide primer and transporting back to AGE E/M store yard/previous location and including charging of refrigerant gas up to required pressure complete all as specified and directed by Engineer-in-charge.
Mechanically leak testing of split AC outdoor unit of capacity 1.0/1.5/2.0/3.0 TR including filling of nitrogen gas for pressure testing, finding leak, brazing of leaked copper pipes, including gas (Refrigerant) charging upto the required pressure, testing after job done for proper functioning complete all as specified and as directed by Engr-in-charge.(Guarantee shall be given for a period of six months)
Supply only factory reconditioned harmatically sealed compressor unit of Split AC 1.0 ton capacity including initial charged of gas and oil complete as per existing specification and make all as specified and directed by Engineer-in-Charge. ( Note: Fixing under item No.1). Make: Gmcc/ Kirloskar Copland/ Carrier/ Goderej/ Blue star/ Toshiba
All as per item No 8 above but for 1.5 Ton capacity Split AC all as specified and directed . ( Note: Fixing under item No.1). Make: Gmcc/ Kirloskar Copland/ Carrier/ Goderej/ blue star/ Toshiba
All as per item No 8 above but for 2.0 Ton capacity Split AC all as specified and directed . (Note: Fixing under item No.1). Make: Gmcc/ Kirloskar Copland/ Carrier/ Goderej/ blue star/ Toshiba
All as per item No 8 here in before but for 3.0 Ton capacity split AC all as specified and directed . (Note: Fixing under item No.1). Make: Gmcc/ Kirloskar Copland/ Carrier/ Goderej/ blue star/ Toshiba
Supply only factory reconditioned harmatically sealed compressor unit of water coolers of 40/80 ltrs capacity including initial charging of gas and oil complete as per existing specification and make all as specified and directed by Engineer-in-Charge. (Note: Fixing under item No.1). Make: Kirloskar/ Goderej / Techumes
All as per item No. 12 but for water coolers of 60/120 ltrs capacity all as specified and directed . (Note: Fixing under item No.1). Make: Kirloskar/ Goderej / Techumes
Supply only factory reconditioned harmatically sealed compressor unit of refrigerators of capacity 165/180 ltrs including initial charging of gas and oil complete as per existing specification and make all as specified and directed by Engineer-in-Charge. (Note: Fixing under item No.1). Make: Kirloskar/ Goderej / Techumes
All as per item No. 14 but for refrigerators of 286/310 Ltrs capacity all as specified and directed . (Note: Fixing under item No.1). Make: Kirloskar/ Goderej / Techumes
Supply only Fan blade suitable for out door unit of split type AC 1.5/2.0/3.0 Ton capacity all as specified and directed . (Note: Fixing under item No.1). (Make : Universal/GE Motors or equivalent) all as per sample.
Supply only Fan motor 1440 RPM suitable for out door unit of split type AC, 1.0/ 1.5 T.R capacity all as specified and directed . (Note: Fixing under item No.1). Make: AE/ American universal/ Carrier/Amtrex/blue star/ Feeders lloyed/Videocon/Hitachi etc. all as per sample.
All as per item No. 17 but for split type AC, 2.0 T.R capacity all as specified and directed . (Note: Fixing under item No.1). Make: AE/ American universal/ Carrier/Amtrex/blue star/ Feeders lloyed/Videocon/Hitachi etc. all as per sample.
All as per item No. 17 here in before but for split type AC, 3.0 T.R capacity all as specified and directed . (Note: Fixing under item No.1). Make: AE/ American universal/ Carrier/Amtrex/blue star/ Feeders lloyed/Videocon/Hitachi etc. all as per sample.
Supply only blower motor for split type AC indoor unit of 1.0/ 1.5 Ton capacity all as specified and directed . (Note: Fixing under item No.1). Make: AE/ Carrier/Amtrex/blue star/ Feeders lloyed/Videocon/Hitachi etc. as per sample
All as per item No. 20 but for indoor unit of 2.0 Ton capacity split AC all as specified and directed . (Note: Fixing under item No.1). Make: AE/ Carrier/Amtrex/blue star/ Feeders lloyed/Videocon/Hitachi etc. as per sample
All as per item No. 20 but for indoor unit of 3.0 Ton capacity split AC all as specified and directed. (Note: Fixing under item No.1). Make: AE/ Carrier/Amtrex/blue star/ Feeders lloyed/Videocon/Hitachi etc. as per sample.
Supply only blower motor for water cooler of 40/80 Ltrs capacity all as specified and directed. (Note: Fixing under item No.1). Make: AE/ Carrier/blue star/Videocon or as per sample held in office.
All as per item No 23 here in before but for water cooler of 60/120 Ltrs capacity. (Note: Fixing under item No.1). Make: AE/ Carrier/blue star/Videocon or as per sample held in office.
Supply only thermostate suitable for water cooler of capacity 40/80 & 60/120 Ltrs capacity all as specified and directed. (Note: Fixing under item No.1). Make: Annapurna/ Infos.
All as per item No. 25 here in before but suitable for refrigerator of any capacity and make all as specified and directed. (Note: Fixing under item No.1).
Supply only relay for water coolers suitable for 40/80, 60/120 Ltrs capacity all as specified and directed. (Note: Fixing under item No.1).
All as per sl item No.27 herein in before but of refigerator of any capacity and make all as specified and directed. (Note: Fixing under item No.1).
Supply only OLP (Over Load Protection) for water coolers of any capacity as per sample all as specified and directed. (Note: Fixing under item No.1). Make: Indfos/ Annapurna .
All as per sl item no.29 herein before but of refigerator of any capacity and make as per sample all as specified and directed. (Note: Fixing under item No.1). Make: Indfos/ Annapurna .
Supply only starting capacitors 80/100 MFD for split type air conditioners all as specified and directed. (Note: Fixing under item No.1). Make: Keltron/ Bajaj/ Epcos/ Havells
Supply only running capacitors 36-60 MFD for split type air conditioners all as specified and directed. (Note: Fixing under item No.1). Make: Keltron/ Bajaj/ Epcos/ Carrier totaline
Supply only running capacitor 2.5 to 4/5/6 MFD for fan motor of Split type AC all as specified and directed. (Note: Fixing under item No.1). Make: Keltron/ Bajaj/ Epcos/Havells/ Carrier totaline
Supply only starting capacitors 80-120 MFD for water coolers all as specified and directed. (Note: Fixing under item No.1). Make: Keltron/ Bajaj/ Epcos/Havells
Supply only running capacitors 25/36 MFD for water coolers all as specified and directed. (Note: Fixing under item No.1). Make: Keltron/ Bajaj/ Epcos/ Havells/ Carrier totaline
Supply and fixing of printed circuit board (PCB) and temperature digital display sensor suitable for split type AC 1.0/1.5/2.0/3.0 T.R capacity all as specified and directed. (Note: Fixing under item No.1). (Make : Carrier/Amtrex/Fedder Lloyed/LG or as per sample)
Removing the split type AC both indoor and outdoor units of any capcity from the existing locaion/ position and refixing in new locaion/position including pump down of gas, disconnection of suction and discharge pipes, boring of hole in new location, provision of PVC sleeve, connecting back the suction and discharge pipes with addition of new lengths of suitable size if required upto 2 m length each, pressure testing, gas charging if required to maintain the required pressure upto 60 psi, leak testing complete all as specified and directed by Engr-in-charge
M&L for rewinding of fan motor outdoor unit of Split AC any capacity and Make, rewinding the motor with super enameled copper winding wire of same gauge and size including necessary insulation material, varnishing, drying & packing etc complete and testing all as specified and directed.
Pressure testing/ leak arresting ,vaccumising gas/oil charging, including replacing the unserviceable strainers and capillary tubes if required etc.., testing complete for Water cooler 40/80 or 60/120 or 150/150 Ltrs capacity all as specified and directed.
Supply only ball brass valves , high pressure, with polythene float and fly nut complete of size 15 mm dia , suitable for water cooler tanks all as specified and directed. (Note: Fixing under item No.1).
Supply only self closing taps cast copper alloy, chromium plated, 15 mm dia suitable for water coolers all as specified and directed. (Note: Fixing under item No.1).
Supply only PVC connection 15 mm size with PTMT nuts of length 600 mm all as specified and directed. (Note: Fixing under item No.1).
M&L for servicing and repairs to voltage stabilizer of any capacity 1 to 5 KVA of any make and model including checking the PCB and making good in all respects suitable for 220/240 V transformer, replacement of time delay relay ,indicator lamps, socket combination 5/15 Amps, plug tops, Cut outs, including replacement of unserviceable internal wiring to rectifying the defects etc.., all as specified and directed. (Note: Spare parts shall be measured and paid separately under appropriate items unless other wise specified).
Supply only single phase 220/240 Volts transformer for 1 to 5 KVA Voltage Stabilizer of any make and capacity all as specified and directed. (Note: Fixing under item No.1).
Supply only 3 Core, 2.5 sqmm copper conductor flexible cable heavy duty PVC insulated sheathed cable suitable for water cooler/Refrigerator/AC all as specified and directed. (Note: Fixing under item No.1).
Supply only 5 amps plug top, 240 volts all as specified and directed. (Note: Fixing under item No.1). Make: Anchor/Cona
Supply only 15 amps plug top, 240 volts all as specified and directed. (Note: Fixing under item No.1). Make: Anchor/Cona
Supply only Air filter suitable for split type AC's of any size and make all as specified and directed. (Note: Fixing under item No.1).
Supply only condensing coil with copper tube and aluminium fins of capacity 1.5/2/3 TR suitable for split AC (Make : LG/Carrier/) or as per existing specification and make all as specified and directed by Engineer-in-charge. (Note: Fixing under item No.1).
Supply only cooling coil with copper tube for indoor unit of split type AC capacity 1.5/2/3 TR . (Make : LG/Carrier/) or as per existing specification and make all as specified and directed by Engineer-in-charge. (Note: Fixing under item No.1).
Dismantling the perished insulation and supply and fix nitrile rubber insulation of size 5/8" for suction and liquid refrigerant line for split type AC all as specified and directed by Engineer-in-charge.
Supply only copper tube 3/8" or 5/8" in repairs all as specified and directed. (Note: Fixing under item No.1).
Supply only copper tube 1/4" or 1/2" in repairs all as specified and directed (Note: Fixing under item No.1).
Supply only Cabinet lamp for refrigerator as per sample all as specified and directed. (Note: Fixing under item No.1).
Supply and fix factory made stand complete set for fixing indoor & out door split type AC of any size and capacity all as specified and directed. (Note: Fixing under item No.1).
Supply and fix Brass suction valve and discharge valve for split type AC 1.5/2.0/3.0 TR all as specified and directed. (Note: Fixing under item No.1).
SUPER COOL
p.chinnasamy
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .