PROVISION OF EXTERNAL SERVICES FOR NET WORK FOR SPECTRUM (NFS) AT AF STATION GWALIOR
2020_MES_383925_1
84085/E8
Open Tender
Civil Works
Lump-sum
540 days
AF STN Gwalior
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE AF TA GWALIOR
₹2.2 L
Yes
9 Dec 2020
7 Oct 2020
9 Nov 2020
7 Oct 2020
3 Nov 2020
21 Oct 2020
Amount
SCHEDULE A PART -I (BUILDING WORKS)
Construction of Net work for Spectrum Bldg in double story complete all as specified and shown in drawings.
Sch A Part- I(A) (CAR PARKING SHED)
Lump sum price worked out by the contractor for "Car Parking Shed" as listed in Sch ‘A’ Part I(A).
Sch A Part- I(B) (SHED FOR D G SET)
Lump sum price worked out by the contractor for "Shed for D G Set" as listed in Sch ‘A’ Part I(B)
Sch A Part- II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for "Internal Water Supply" as listed in Sch ‘A’ Part II.
Sch A Part -III (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION" as listed in SCHEDULE ‘A’ PART- III .
Sch A Part -IV (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Sch ‘A’ Part- IV .
Sch A Part- V(ROAD,PATH &CULVERT)
Lump sum price worked out by the contractor for "ROAD,PATH & CULVERT", as listed in Sch ‘A’ Part-V.
Sch A Part -VI (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL",as listed in Sch ‘A’ Part- VI.
Sch A Part -VII (AREA DRAINAGE)
Lump sum price worked out by the contractor for "AREA DRAINAGE,as listed in Sch ‘A’ Part- VII.
Sch A Part -VIII (SECURITY WALL/FENCING GATE)
Lump sum price worked out by the contractor for "SECURITY WALL/FENCING GATE",as listed in Sch ‘A’ Part- VIII.
Sch A Part -IX (COOLING APPLIANCE),
Lump sum price worked out by the contractor for "COOLING APPLIANCES",as listed in Sch ‘A’ Part- IX.
Sch A Part -X (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY",as listed in Sch ‘A’ Part- X.
Sch A Part -XI ( DEMOLITION & DISMANTLING WORKS)
Lump sum price worked out by the contractor for "DEMOLITION & DISMANTLING WORKS",as listed in Sch ‘A’ Part- XI .
Sch A Part -XII ( SITE CLEARANCE & DEVELOPMENT , EXCAVATION AND EARTH WORK)
Lump sum price worked out by the contractor for "SITE CLEARANCE & DEVELOPMENT , EXCAVATION AND EARTH WORK",as listed in Sch ‘A’ Part- XII .
Sch A Part - XIII (Miscellaneous Items of B & R and E & M)
Earth filling under floors or in foundations including watering and consolidation, spreading and levelling in layers n exc. 25 well ramming as required complete all as specified and directed. cm thick
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 2 TR (6000 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit , minimum 5 star rating complete comprising of following :- Make :- Carrier/Dikin/Hitachi/Blue star. (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising . Compressor with motor, air cooled copper condenser with fan and motor unit shall be installed out side the building/ on roof. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated mild steel bracket fixed on wall as per manufacture's instruction with necessary grouting mild steel hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 2 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate.
S&F Sub main wiring using two runs of single core FRLS PVC insulated, unsheathed stranded copper conductor cable conforming to IS : 694 of size 2 x 4 .0 Sq.mm for main wire of voltage rating 1100 V & drawn in and including concealed PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked of dia not less than 25mm with standard accessories, alongwith one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 1 x 4.0 Sq.mm as as earth wire complete all as specified and directed. Note-Two runs of single core PVC cable 4.0 Sq.mm with one run of 4.0 Sq.mm as earth wire conductor and conduit shall be measured as one unit.
Supply and fixing 5 KVA voltage stabilizer for automatic opration ,single phase naturally air cooled indoor type & designed for input variation 170V to 250V with out put voltage stabilized at 230 V with accuracy of + 1 % Suitable for 2 TR A C complete all as specified and directed. Make of stablizer V Guard Model No VND 500 or equivalent as approved by GE
Supply and fixing industrial type plug socket, SPN and earth plug 250V, 20 amps with steel enclosure and one MCB SP 20 Amps complete all as specified and directed.
S & F DB TPN sheet metal enclosure double door suitable for (IP-43) protection Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete all as specified and directed.
Supplying & fixing MCB TPN 63 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.
Supply & Fixing MCB SP, 6 Amps to 32 Amps ('C' series) having current rating 10 KA complete all as specified and directed.
Supply & Fixing MCB SPN, 40 Amps ('C' series) having current rating 10 KA complete all as specified and directed.
M& L for machine pressed precast concrete interlocking paver block of approved shape and size of 80 mm thickness, with minimum compressive strength of 40 N / Sqmm (M-40 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, with white cement and pigment laid over and including 20 mm thick (compacted thickness) sand cushioning of interlocking tiles /Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L single brick masonary valve pit chamber of size 600 mm x 600 mm x 600 mm( internal dimension), with 3.15 mm thick mild steel sheet cover fixed with two Nos stainless steel hinges of 75 mm long on angle iron frame of size 40 mm x 40 mm x 6 mm thick (mild steel sheet cover and angle iron frame shall be painted with two coat black bituminious paint over a coat of red oxide primer) , PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate ) as in foundation, 230 mm thick brick wall built in cement mortar 1:4, 50mm thick coping with PCC 1:3:6 , type C-0 ( using 12.5mm graded crushed stone agreegate) , 15 mm thick rendering in cement mortar 1:4 to all internal and exposed surfaces of valve pit including necessary excavation and earth work etc all as shown in drawing & as directed.
Supply, installation, fixing, jointing and testing 80 mm bore, ISI marked, of approved quality, cast iron sluice valve of class PN-1.0 conforming to IS-14846 of 2000, both ends flanged and drilled with iron wheel head and stainless steel spindle, long body type, jointed and tested complete all as specified and directed. (Make:- Kirlosker/Kejriwal/Upadhayay)
M & L earthing complete with Gl electrode 600 mm x600 mm x6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 2.50 mtr below normal ground level connected to galvanised wire 4 mm dia as earthing wire (lead) by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75 mm x75 mm x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 20 mm dia Gl tubing light grade and necessary fitting for protection of Gl wire including laying of charcoal, dust and common salt PCC 1:3:6 type C-1( using 20 mm graded crushed black trap/ granite/ Basalt stone aggregate), 40 mm thick pre-cast cover reinforced cement concrete with 8 mm dia TMT bars@ 75 mm c/c both way with 12 mm dia round bar as handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, 15mm thick rendering in cement mortar 1:6 internally and upto 150mm below ground level & externally. PGI funnel with wire mesh , complete all as shown on electrical plate No.3 of SSR Part -1( 2009) and connected in earth test including testing completed all specified and directed. NOTE :- (i) The rates quoted shall also deemed to include the cost of Earth test point and earth wire and protection pipe upto 7.5 meter beyond the earth plates electrode and the earth resistance of the whole system shall be as near as possible to 0 but shall not in any case exced one ohm. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed / permitted.
Supply, installation, commissioning water dispenser (5 star rating) with a small refrigerator of 20 Ltr at the bottom with hot, plain and cold water and small cabinet for keeping small food items in the bottom of the refrigerator, complete all specifed and directed..Make :Blue star Cat Part No BWD3FMRGA or equivalent as approved by GE
Supply, installation and testing desert cooler with CFM 4500 Cum/hr electric driven single phase 230 Volts AC made out of galvasinsed plain, mild steel sheet 1.20mm thick body and leak proof water tank, electric fan motor single phase 950 RPM, single phase submersible pump set, front grills, fan regulator 3 step load, switches for fan and pump control seperate connection with PVC copper cable 3 core 1.5 Sqmm with top including PVC pipe complete all as specified and directed by Engr-in-charge
S & F four Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA adjustable thermal & adjustable magnetic types (in existing panel) complete all as speicified and directed.
M&L for Boring of holes under road,pavement hard standing by trenchless technology using ultra sound technique and necessary machine including supply & laying HDPE pipe of size 150mm dia suitable for 0.4Mpa working pressure complete in all respect and all as specified and directed.
Supply, Installed, Testing and Commissioning CPRI approved cubical type LT Panel floor mounted out door type for 415V, 3 phase 4 wire system 50 Hz AC supply with Copper bus bar duly colour coded, for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve having complete connection from bus bar to breakers with suitable copper cable , factory made fabricated with CRCA sheet totally enclosed, dust weather and vermin proof for outer shell and 2 mm thick for inner shell having TPN copper bus bar rating 1.5 times that of controlling MCCB supported on SMC insulator with short circuit withstand capacity 35 MVA for 1 second, bottom base channel mild steel section not less than 100mm x 50mm x 5 mm thick, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size of copper wiring with minimum 1.5 Sqmm PVC insulated copper conductor cable , cable alleys, cable gland plates in two half inculding tamper proof digital energy meter to measure volatge current PF, KWH,KVAH,KVAR (make Secure/L&T/HL/Schneider) and general construction confirming to IS-8623/93 and mounted on suitable PCC foundation with following detailed specification & control :- complete with suitable fixing accessories.
OUTER SHELL :- The outer shell shall be made of 3. 0 mm thick CRCA body & mild steel angle section 50 mm x 50 mm x 6 mm frame with front & back openable, single door system lockable/ openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate a hinge provision for entry of armoured cable of adequite size of glands. The dimension of the outer shell should be adequite to accododate inner shell described below figing 50 mm space all around and shall be fabricated in such a way that the complete inner shell along with its control gears and accessories should be taken outside without disturbing outer sheel. The outer shell shall be mounted on a zinc metal coated stand. Provision of threaded earthing studs at bottom and lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be providid. The degree of protection of outer shell shall be IP-54.
INNER SHELL :- Inner shell be made out of 2.0 mm thick CRCA body compartmentalized for each control gear, front openable single door system lockable/openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers and air vents gasket for natural flow of air "U' type gasket shall be used to make the inner shell completely vermin proof and to accomodate incomer/outgoing MCCB's and TPN copper bus bar and extension links of rating not less than the 1.5 times rated capacity of the respective MCCB's. The TPN bus bar and extension links shall be insulated with colour coaded heat, shrikable sleeve and shall be mmounted on suitable size 'F' class through out the length of the TPN bus bar. Computer cut slef adhesive vinyl danger notice plate having conventional symbol of bone and skull shall be providid on bus bar chamber. All control wires shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75 mm x 50mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness 3.15 mm zinc metal coated should be used at the bottom, indicating lamps LED type, 230 Volt, AC at the incomer of the unit to show three phase availablity at the incomer. An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell. The degree of protection for inner shell shall be IP-42 and carrly the floowing control :-
(A) Incoming :- (a) MCCB 4P, 250A having breaking capacity 36KA ,adjustable magnetic and adjustable thermal setting from 80% to 100% and rating-01 No. (b) The following items are provided in one compartment :- (i) Digital Voltmeter - 01 No (ii) Digital Ameter - 01 No (iii) Three Indiaction LED Lamp (B) Out going :- (a) MCCB 4P, 160A having breaking capacity 25 KA adjustable magnetic and adjustable thermal setting from 80% to 100% and rating-01 No., (b) MCCB 4 P 100 Amphaving breaking capacity 25 KA ,adjustable magnetic and adjustable thermal setting from 80% to 100% and rating-01 No., (c) MCCB 4 P 63 Amphaving breaking capacity 16 KA, adjustable magnetic and adjustable thermal setting from 80% to 100% and rating- 03 Nos.
Disconnecting electric connection , cable, panel & earthing, dismantelling from foundation DG Set with/ without canopy , loading in vehicle including panel shifting to any site with in Tech Area unloading safely, installation, commissioning and testing complete of Capacity of 125 KVA DG Set with AMF panel complete all as specified and directed.
M & L earthing complete with GI electrode 600 x 600 x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 2.50 mtr below normal ground level connected to GI strip 32 mm x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of brass connected all as specified including excavation and earth work and disposal of surplus soil including 40 mm GI tubing light grade and necessary fitting for protection of GI strip including laying of charcoal, dust and common salt PCC (1:3:6) type C-I (using 20 mm graded crushed stone aggregate) earth pit with 40 mm x40 mm x 6mm mild steel angle iron frame including 40 mm thick pre-cast RCC cover (1:2:4) type B-1( using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 12 mm dia round bar , plastering 15mm thick CM (1:6:) internally and upto 150mm below ground level externally, funnel with wire mesh 20mm dia GI pipe for watering complete all as shown on electrical plate No.3 of SSR Part- 1( 2009) and connected in earth test including testing completed all specified and directed. NOTE :- (i) The rates quoted shall also deemed to include the cost of Earth test point and earth strip and protection pipe upto 7.5 meter beyond the earth plates electrode and the earth resistance of the whole system shall be as near as possible to 0 but shall not in any case exced one ohm. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed / permitted. (iii) The length of the GI strip beyond 7.5m will be measured and paid seperately. (iv) Test result of earthing to be submitted by the contractor for all earthing . (v) The rate quoted by the contractor shall also be deemed to be including :- (a) Testing submission of earth result as desired. (b) Excavation upto 5 mtrs depth and returning filling in any type of soil
Supply, installation, commissioning and testing of 125 KVA indoor type 348 to 452 V, 3 Phase, 50 Hz, IGBT PWM, natural air cooled type, LT automatic electronic voltage stabilizer unbalanced supply and unbalanced load, complete with the following features as required for trouble free operation:- (i) input supply :- 348 to 452 Volts, 3 Phase, 50 Hz (Unbalanced suplply). (ii) Output Supply :- 400V (+-) 1%, 3 Phase, 50 Hz (Unbalanced load) (iii) Rate of correction :- 3000V/Sec (iv) Protection high low or over load cut off, single phase preventer. (v) Overload Cap :- 125% (vi) With auto reset features in event of high low or over load cut off. (vii) Duty cycle : - Continuous. (viii) Class 2 Surge and spike protection. (ix) Response time ;- < 10msec. (x) By pass :- Automatic/manual by pass. (xi) Safety Protection designed to meet UL 60950 – I Standard. (xii) Warranty 27 months. Note :- The contractor shall obtain prior approval of detailed specification of SVR by GE before ordering.
’Supply, installation, testing & commissioning of isolation transformer (1:1 ratio) of 75 KVA, 3 Phase, 415 Volts, 50 Hz, Dyn 11 vector group, metallic body duly powder coated delta/star, copper wound, Air Cooled indoor type with IP-55 protection, Efficiency>98%, Separate neutral bushing for earthling, Digital temperature gauge, 2 Nos of earthing terminals & CPRI approved. Complete all as specified and directed by Engr-in-Charge. Note : - The contractor shall obtain prior approval of detailed specification of SVR by GE before ordering.
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and Including all necessary excavation & earth work in any type of soil for foundation of poles, PCC 1:3:6 type 'C-2' (using 40 mm graded stone aggregate ) in foundations of size 600 X 600 X 1650 mm below GL, PCC 1:2:4 type "B- 1 (using 20 mm graded stone aggregate) in plinth block(coping) of size 600 X 600 X 300 mm above GL , removing surplus soil to a distance n. exc. 50 m & depositing where directed, including necessary form work and 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete all as specified and directed.
S&F Junction box made out of FRP sheet , ready made type having copper bus bar of capacity 100 Amps 4 Nos including bakelite connector of size 388 mm x 304 mm x170 mm with necessary connector , MCB 6 Amps and entry of gland and fixing arrangement to fix the box on pole by providing mild steel clamp of size 25 mm x 5mm - 2 Nos complete all as specified and directed by Engineer-in-Charge. Make:.SYNTEX as per product code GSJB-3525 or in equivalent as per approved by GE.
S&F GI pipe light grade bracket 40mm dia, 1.5m long bent to shape as required for fixing of street lights on poles/walls including nuts, bolts, washers , clamps (02 sets) of suitable size complete all as specified and directed.
Supply, fixing, testing and commissioning 70W LED Street light fitting IP-66 protection with system output of 7000 lumens & with dedicated street light optics, System efficacy of greater than 100lm/W luminarie should have pressure die cast aluminium LM6 housing. Luminaire should have dedicated street light optics for better uniformity & spacing. Luminarie should have air vents in housing for proper thermal management. . Luminarie should be minimum 50000 burning hrs with 70% lumen maintenance PF>0.95 & input voltage range 120-277Vac. Min CRI 70 colour temperature should be >5500K alongwith earth contunity wire, all necessary connections and gurantee of 2 years complete all as specified and directed. Make :Cromption/Wipro/ Havells . Note: Driver & LED should be same make
Material and labour for Chemical earthing complete with copper plate electrode 900 mm X 600 mm X 5mm buried directly in ground vertically to a depth not less than 4.70 meter below normal ground level (with top edge of earth plate not less than 3.60 meter below ground level) and size of earth pit 1.20 m X 1.20 m X 5.1 m(depth) connected to copper earth strip 32 mm x 6 mm (main earthing lead) by means of tinned copper / brass bolts, nuts, check nuts and washers besides brazing at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil earth electrode ,earthing lead from electrode to test point and filling with and including 150mm thick layer of charcoal,150mm thick common salt and 150mm thick magnesium sulphate in alternative layer upto a height of 1800 mm from bottom of pit all around the copper plate GI pipe 50mm dia medium grade for protection of earth lead ,20mm dia watering pipe ,mild steel funnel with wire mesh including necessary earth work and PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) for earth pit of size 300 mm x 300 mm x 300 mm (Internal Size) and with 100 mm wall thickness over and including PCC base of size 1500 mm x1500 mm x 150mm using PCC 1:4:8 mix type D-2 (using 40 mm graded crushed stone aggregate) and 40mm thick precast RCC cover in (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) with 3 Nos 8mm dia TMT bars both way with 12 mm dia round bar handle including watering before burried of electrode and before making of pit complete all as specified and directed. NOTE:- (i) The cost of earth lead and protection pipe upto and including 7.5 mtr only from the centre of earth electrode are deemed to be included under this item and additional lead, if any, required at site shall be measured and paid for separately under appropriate item of Schedule 'A'. (ii) Any joint in earth lead from earth electrode to test point shall not be allowed/ permitted. (iii) Earth result of the pit shall be less than 1 Ohms, during the maintenance period also to be maitained earth resistance less than 1 Ohms falling which new earthing to be provided by the contractor with out any extra cost.
S & F Surge protection device TP + N suitable for 75 kva load three phase, 415 Volts, 50 Hz complete all as specified and directed.
M&L for angle lamp holder, insulated body with back plate with & including LED Lamp 09 watt suitable for batten fittings complete all as specified and directed Engineer-in-Charge. Make :Anchor/ Cona/ Havells
S&F Sub main wiring using two runs of single core FRLS PVC insulated, unsheathed stranded copper conductor cable conforming to IS : 694 of size 2 x 10 .0 Sq.mm for main wire of voltage rating 1100 V & drawn in and including concealed PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked of dia not less than 32 mm with standard accessories, alongwith one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 1 x 10.0 Sq.mm as as earth wire complete all as specified and directed. Note-Two runs of single core PVC cable 10.0 Sq.mm with one run of 10.0 Sq.mm as earth wire conductor and conduit shall be measured as one unit.
S&F LED Stout plus LED is a complete range of industrial LED batten to replace traditional T8 batten. The range is perfect for lighting large areas such as corridor, ware houses & general purppose spaces 40 watt including all accessories, pre-wired and connecting the same to ceiling rose with & includuing three core PVC insulated and sheathed copper conductor 1.5 sq.mm cable with all accessories and fixing arrangement for fixing the light fitting to walls /roof surface complete all as specified and directed. Make:- Havells Cat No. STOUTPLUS1200BS40WLED857SPCWHor in equivalent of Philips/CG/Wipro as approved by GE
Supply, fixing,connecting & testing sheet metal enclosure double door suitable for Single pole and neutral 415 V 8 Way for using MCBs/MCB isolators with 200 Amp rated standard having aluminium bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete all as specified and directed.
Supply, fixing,connecting & testing sheet metal enclosure double door suitable for Triple pole and neutral 415 V 4 Way for using MCBs/MCB isolators with 200 Amp rated standard having aluminium bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete all as specified and directed
Supply and fixing ceiling fan with down rod, fan connector/fan hook, 1200mm sweep ( model Fusion-50( five star) , 240V AC with 3 fan blade and connecting up including provn of three core PVC insulated multi stranded flexible copper conductor cable of size 1.5 Sq.mm copper wire from connector to fan of length not less than 0.5 mtr complete all as specified & directed. Make – Usha/Crompton greave/Bajaj/Orient
Supply and fixing Exhaust fan of 300 mm sweep (heavy duty) single phase 230 V AC, 900 RPM, with louvered shutters including mounting frame, nut, bolts, washer, fasteners etc and connecting exhaust fan to ceiling rose including provIsion of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as specified & directed.Make – Usha/Crompton greave/Bajaj/Orient
M&L for 150mm thick granular sub-base (using 40mm graded crushed stone aggregate ) Grade -1, deposited, spread and levelled ,watered in two layers of 75mm thick each, watered and rolled with 8 to 12 tonne capacity power road roller to a true surface complete all as specified & directed.
M&L for 200 mm thick cement concrete work in pavement of flexural strength of 45kg per sqcm in field using 400kg of cement/cum complete all as specified & directed
M & L for Construction of Septic Tank for 50 users including necessary earth work in excavation in any type of soil , plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 , ,reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast man hole cover slab having 8 mm dia TMT bar reinforcement @ 75 mm c/c & 6 mm thick mild steel plate embedded all around of cover slab , 15 mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber , form work to sides and soffits, 150 mm dia SGSW inlet & out let pipes up to 3 m from outer face of wall, CI vent pipe, sludge chamber, RCC baffle wall, returning filling & removal etc, complete all as shown on drawings & as specified.
M & L for Construction of Soakage well for 1.80 m dia( internal dia ) & 3.0 m (effective) depth including necessary excavation in earth work in any type of soil , plain cement concrete 1:3:6 type C-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 in walls & honey combed brick wall , reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast cover slab having 8 mm dia TMT bar reinforced , plain cement concrete band , form work to sides and soffits of RCC slab & filling with brick bats loose filling complete all as specified and shown in drawings.
M/s Kohli Builders
M/S LAKSHYA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .