Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹32.9 L+₹40,588.90 (1.25%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹36.7 L+₹4.2 L (12.9%)Rejected-Finance 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹37.7 L+₹5.2 L (15.9%)Rejected-Finance FLAT NO B 205 S NO 296 2 DIVINE HOMES PORWAL ROAD LOHEGAON PUNE 411047 | PUNE | MAHARASHTRA | 411047 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹38.5 L+₹6.0 L (18.5%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
19 Jul 2024, 6:00 pmClosed
GE AF LOHEGAON
GE AF LOHEGAON LOHEGAON PUNE-411032
REPAIRS, CLEANING AND DAILY MAINT OF SEWAGE LINES, SEPTIC TANKS, UG SUMP, REPAIRS TO COMPOUND WALL, FENCING,PATHWAY AND HARDSTANDING AT TECH AREA, OMQ AREA,SINGLE OFFR ACCN AND OFFICER MESS UNDER AGE B/R-I OF GE (AF) LOHEGAON AT 2 WING AF STN PUNE
2024_MES_662123_1
8821
Open Tender
Civil Works
Item Rate
330 days
AFS PUNE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹84,000
Yes
12 Dec 2024
26 Jun 2024
22 Jul 2024
26 Jun 2024
19 Jul 2024
3 Jul 2024
Amount
M & L for Removal of blockage of sewage lines including manholes by using necessary tools/mechanically tools or manually such as passing rope knots bamboo kamti and disc of required size including safety measures such as test for gas etc before flushing the pipe well with water after removal of blockage of 100mm bore pipe.
All as per item No 1 as above but bore of pipe 150mm.
All as per item No 1 as above but bore of pipe 200mm to 300mm.
Note for ser item No 1 to 3:- (i) The rates quoted in the above item includes cost of T&P like rods, bamboos, gum shoes and hand glouses etc complete (ii) Minimum one sweeper and one helper shall be deployed by contractor and they shall be present on all days from 0900 hrs to 1700 hrs including holiday and Sunday for maintenance of sewage lines. The persons will be detailed by JE/AGE concerned every morning for attending complaints on daily basis. (iii) The complaint has to be rectified within 24 Hrs as given in complaint slip failing which penalty will be imposed @ 500/- per complaint per day and for ser no (ii) also.
M& L for Taking out silt, liquid water sludge in solid/semi solid state from septic tank/Manholes STP tanks of any capacity and size and removing the same using truck mounted honey sucker of capacity minimum 4 cum and to dispose off the sludge to in low lying area at any distance including Sunday and holiday as per requirement depositing the sludge in low laying area with covering by earth over it and leaving the septic tank/sump clean etc. all as specified complete. Note : Driver and operator must be passes a valid license and confirm the serviceability of the Truck.
M & L for Cleaning of sewer line by mechanically by truck mounted sewage cleaning of sewage line water sludge tank with wash down system / suck derrick arm hydraulically spring loaded rotary sliding vane compressor with V hose end section no 33 nozzle and strainer all as specified and as directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation and getting out in soft /loose soil.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation and and getting out in Hard/dense soil.
Demolition and breaking up drain pipes SGSW pipe including fittings and packing ,hunching and bed concrete complete of the size 100mm internal dia of SGSW pipe complete all as specified and directed.
Demolition and breaking up drain pipes 150mm internal dia of RCC pipe including fittings and packing, hunching and bed concrete complete all as specified and directed.
Demolition and breaking up drain pipes 200mm internal dia of RCC pipe including fittings and packing hunching and bed concrete complete all as specified and directed.
M/L for PCC (1:3:6) type C2 concrete bed to drain pipes of dia 100mm dia including packing under and haunching against the sides of pipes after they laid and tested.as reqd on ground condition.
M/L for PCC (1:3:6) type C2 concrete bed to drain pipes of dia 150mm dia including packing under and haunching against the sides of pipes after they laid and tested.as reqd on ground condition.
M/L for PCC (1:3:6) type C2 concrete bed to drain pipes of dia 200mm dia including packing under and haunching against the sides of pipes after they laid and tested.as reqd on ground condition.
S&F 100mm bore salt glazed stone ware drain pipes Grade A laid in trenches and joined complete all as specified and directed.
S&F for Reinforced concrete pipes class NP-2, laid and jointed complete with collars if required for 150mm dia pipes.complete all as specified and directed.
All as per item No 16 as above but for 200 mm dia pipes.
Taking out (desilting) silt brick bats, debris , liquid waste sludge in solid/semi solid state from manholes including pumping out sludge wherever necessary diverting the flow in the drain , if necessary and stacking the removed silts in depots away from the edge of manholes as directed including use of sfery belts, dry cells torch for lighting inside the manholes and taking similar precautionary measures and removing the sludge etc to a distance exc 250 mtr but not exc 500m & leveling the manhole cleaned and flushed with water etc all as specified /directed manholes up to the depth of 1.00 mtr.
All as per item No 18 as above but manholes depth exc 1.00 mtr and n exc 2.00 mtr .
All as per item No 18 as above but manholes depth exc 2.00 mtr .
Dismantling of CI/PVC drain pipes 50 to 110 mm
S&F 110mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
Ditto all as per item No 21 as above but fixed in walls including clamps complete all as directed.
S&F 75 mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
Ditto all as per item No 24 as above but fixed in walls including clamps complete all as directed.
S&F in repair 110mm bore PVC (SWR) bends any radius with acess door complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) bends any radius with acess door complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) branch piece, single T with access door equal or unequal complete all as specified and directed.
S&F in repair PVC (SWR) Reducers all as specified and directed.
S&F in repair 75mm bore PVC (SWR) branch piece, single T with acess door equal or unequal complete all as specified and directed.
S &F in repair PVC (SWR) Vent cowl all as specified and directed.
Cleaning the CI/PVC/SGSW pipe of any dia from water closet /floor trap/nahani trap to Ist holes by rodding/choke remover manually as in foul condition after taking off manholes cover and placing the manholes cover in original position etc complete all as specified and directed. (Note :-Contractor has to detail two labour (Safaiwala) daily to attend complaint at complaint cell at 9.00 AM who will again report to Engr-in-Charge after completion of complaint with complaint slip duly signed by the users).
M & L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required 150mm Dia complete all as specified and directed. ( Note : Work in Foule Position )
S & F PVC (SWR) gully trap 110 mm dia fixed in cement concrete including removal of existing old damaged gully traps and providing connection upto 1st manhole with PVC pipe complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for coloured Non skid ceramic tiles of size 300x300mmx7mm thick in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15mm thick screed bed in CM (1:6).
M&L Glazed Ceramic Coloured Tiles, 300X200X7/450x300x7/600x300x7mm in size, set on Vertical Surfaces such as Skirting, Dado, etc,over and including 10mm thick rendering in cement mortar 1:3 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed.
S&F vitreous chinaware EWC including connection to drain or outgoing pipe and to PVC flushing pipe, antisyphonage pipe, PVC low level flushing cistern 10 ltr capacity with brackets of approval Make and all necessary fittings etc complete all as directed and specified incl PVC seat cover fixed in repair all as specified and directed.
S & F in repair floor gratings 100mm dia with o without waste hole of PTMT (mim waight 40 grms) all as directed by the Engr-in-Charge
S&F waste pipe of polyethylene of low or high density or PVC ,32 mm dia for wash basin/ sink /flush tank fixed in repairs. complete all as directed by Engr-in-charge.
Demolition of PCC of any description provided for complete all as specified and directed.
M&L for Cement concrete type D-2,1:4:8 (40mm graded aggreate) 75 mm thick as in sub -floors ,sub- bases ,floors and pavings,etc.
M & L PCC 1:3:6 type C2 using 40mm graded stone aggregate as in bedding or surface channel and drains complete all as specified.
M&L for PCC type C-2, (1:3:6) , using 40mm graded crushed stone aggregate as in lean conc , sub base ,or mass conc , foundation filling etc all as specified and directed.
Extra for forming fair finished channel or drain up to 30 cm inner girth in cement concrete using extra cement including forms, moulds mitered/stopped ends etc. all as directed by Engineer-in-Charge.
M&L for Cement concrete type B-2,1:4:8 (40mm graded aggreate) 100 mm thick as in sub -floors ,sub- bases ,floors and pavings,finished with spike rolling to surface or making impressions of expanded metal ,whilst the concrete is green all as specified and directed.etc..
M&L Forming Contraction (Dummy) joints 75 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade 'A' in plinth protection
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition), all as specified and as directed
M&L for precast RCC (1:2:4) type B1 using 20mm graded stone aggregate as in cover slab (for manholes etc) and set in cm 1:6 including necessary form works complete all as specified and directed.
M/L PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in coping ,rounded or chamfered on edges complete all as specified and directed.
M&L for MS TMT bars 10mm dia and over as in reinforcement cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with and including MS annealed wire not less than 0.9mm dia.complete all as specified and directed.
All as per item No 51 as above but 8mm dia as in stirrups and links all as specified and directed.
S & F PVC (SWR) floor trap 75 mm dia fixed in cement concrete including jointing with solvet cement and making all good all as specified and directed.
Returning,filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm all as specified and directed.
Removing excavated material n exc 52m and depositing where directed at a level n exc 1.5m above the starting point all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
M&L for Fe 410-W (GdeE- 250) quality A Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
Supply and fixing mild steel work as in angle iron, flat iron of any size for post and struts as in fencing including, cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets for securing wire mesh ,chain link fencing etc including all necessary drilling bolting or riveting etc and/or fixing with screws, bolts etc. and similar work conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed.
-ditto- as above but fixing only.
Supply and fixing Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L Chimney bars(straight or camber),bearing bars for fencing ,ton-gues or water bars for window frames, window guard bars,plain,let in and fixed independently in wooden frames,Lor Tsection supports for shelves etc,and similar articles conforming to Fe-290 Gde E-165.
Dismantling chain link fencing/expanded metal or mesh not exceeding 4kg/Sqm fixed in steel, wood fillets, concrete post etc. of any description.
Fixing only Chain link fencing including line wires, any mesh size and type to any type of standards,rails, straining bolts,etc.including provision of binding wire.
Supply only chain link MS galvanised fencing of weight not less than 3.5 Kgs per sqm and size as directed by Engr-in-charge.
S & F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) incl removal of old unservicebale barbed wire.
Restraining resecuring including making good staples etc Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) incl removal of old unservicebale barbed wire.
S& F in repairs wire entanglements wth galvanised steel concertina coil of dia 600 mm reinforced with punched (chrome rajor of blade wire) barbed tape of 2.5mm thick galvanized steel sheet at 75mm saplings and core wire of dia 2.24mm high tensile steel wire complete all as specified and directed by the Engr-in-Charge.
M&L for preparation new steel surfaces of any description, not otherwise described, over 10cm width/girth and applying two coats of synthetic enamel paint over a coat of Red oxide primer complete all as specified and as directed
Demolition of stone slabs and chequired tiles of any description or thickness in floors aprons etc.laid bedded and pointed in any mortar.
M&L PCC 1:2:4, 25 mm thick type B0 using 12.5mm graded stone aggregate as in floor finished even and fair with out using extra cement complete all as directed by Engr-in-charge.
M&L for Glossy finish Chequred cement concrete tiles set ,pointed & jointed in neat cement slurry in floors polished with grey pigment cement and pigments Laying over 20mm thick cement screed base (1:6) and all as directed by Engr-in - charge.
Demolition of bricks (laid flat or on edge) or interlocking tiles in floors, channels, kerbes, aprons, etc laid dry of laid dry and pointed.
M&L for Cement concrete type D-2,1:4:8 (40mm graded aggreate) 100 mm thick as in sub -floors ,sub- bases ,floors and pavings,etc..
M&L sand filling (30 mm average thickness) under floors in foundations and for laying Interlocking paver blocks including watering and consolidation complete all as specified and as directed by Engr-in-Charge..
M&L Glossy finish machine pressed precast concrete interlocking paver block any shape and size polished with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickiness M-35 grade complete all as specified and as directed by Engr-in-Charge..
Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc. complete all as specified and as directed
M&L for 10mm thick rendering on fair faces of brick works finished even andfair without using extra cement in cement mortar 1: 4 complete all as specified and as directed
M&L for 15 mm thick rendering on stone masonry works or other than fair faces of brick work or concrete surface finished even and fair without using extra cement in cement mortar 1: 4 complete all as specified and as directed
M&L for 20 mm thick rendering on stone masonry works or other than fair faces of brick work or concrete surface finished even and fair without using extra cement in cement mortar 1: 4 complete all as specified and as directed
Supply only liquid water proofing compound
Demolition of Brick/precast concrete block/Stone/boulder masonary walling built in cement mortar all as specified and directed.
M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:4 all as Specified.
Ditto but except blocks.
M&L random rubble stone masonary well bonded bedded solidily hearted in CM 1:4.
-ditto- as above but except stones.
Providing and fixing Precast cement concrete louvers and jallies 25mm thick Type B0 1:2:4(20mm graded aggregate) (measured solid) set in cement mortar 1:4 ,including all moulding but excluding frame(pre cast frame shall be measured separately as Item above)
Demolition of cement concrete in ground floor and pavings n.exc 15cm thick below or above ground level all as specified and directed.
M&L for PCC type C-2, (1:3:6) , using 40mm graded crushed stone aggregate as in lean conc , sub base ,or mass conc , foundation filling etc.
M&L for preperation of new plastered wall surface of any description and applying two coat of cement based paint over a coat of chalk whiting complete all as specified and as directed.
M&L for preperation of old plastered wall surface of any description and applying one coat of cement based paint complete all as specified and as directed.
M & L for 75 mm PCC 1:3:6 type C-2 using 20mm graded aggregate as in floors ,plinth protection and pavings finished with spike rolling to surface or making impressions of expanded metal ,whilst the concrete is green all as specified and directed.
M&L Forming Contraction (Dummy) joints 75 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade 'A' in plinth protection
M&l for PCC type D-2(1:4:8) using 40mm graded crushed aggregate as mass conc and filling of foundation all as specfed and drected.
M & L for PCC type C2 1:3:6 (40mm graded aggregate) as in surface channel of drain all as specified and directed.
M & L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms/moulds mitread/stopped ends etc
M & L for grantite 20mm thick (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing width white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and directed.
Machine cut cudappah stone slab 20-25mm thick over 10mm thick plaster of cement 1:3 in wall and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition), all as specified and as directed
M&L form work to rough finished surface to sides of beams, sides and sofits (if any) of foundations and plinth beams and similar works: verticals or to batter
M&L RCC type B1 1:2:4 (20 mm grade aggregate ) in beams,plinth beams,Lintels etc,basement slabs , under reamed piles ad mass concrete.
M&L for broken glass coping on top walls in cement mortar 1:3 including dimolition of old existing glass coping(if required) and removing the rubbish
Dismantling posts or struts (wood,steel or RCC)any section ,including taking out embedded in concrete or brickwork .
S & F RCC Septic tank 25 Users (Length -2500mm and Dia 900mm) all as specified and directed
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete
RK ENTERPRISES (BID ID -3053165)
R k construction (BID ID -3063211)
BSK Construction (BID ID -3055153)
Pratap enterprises (BID ID -3059346)
D S KADAM (BID ID -3067494)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .