| 1 | 1₹70,000Accepted-Finance | 1 | Accepted-Finance The technical and financial bid are found in order. | |
| 2 | 2₹78,800+₹8,800 (12.6%)Accepted-Finance | 2 | Accepted-Finance The technical and financial bid are found in order. |
Tender Value
₹1.2 L
EMD Value
₹2,439
Closing Date
2 Sept 2024, 3:00 pmClosed
EE, NACD, APWD, Mayabunder
EE, NACD, APWD, Mayabunder
Supplying ,Installation and Testing Commissioning of 01 No. 02 Ton Air Conditioner at JMFC Bungalow, Mayabunder
2024_APWD_15188_1
NIT No. 203/2024-25/EE/NACD
Open Tender
Electrical Works
Works
15 days
EE, NACD, APWD, Mayabunder
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹2,439
5 Sept 2024
13 Aug 2024
2 Sept 2024
13 Aug 2024
2 Sept 2024
13 Aug 2024
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, installation, testing and commissioning of following capacity and rating wall mounted split Air conditioner, inverter type fitted with rotary compressor operating on 230v ± 10%, 50Hz single phase AC supply with evaporator and condensing unit made of copper tubes , cordless remote control, copper piping for both suction and discharge of five (05) meters length with protection covering for piping of suitable size of medium PVC pipe, power and control cabling as per site requirement, outdoor stand duly painted, comprising of following etc. complete as per requirement including first charge of refrigerent. a) Insulated copper pipe lines liquid and suction lines as per manufacturer rocommendation. b) Flexible copper cable between indoor & outdoor unit of suitable size as per manufacturer rocommendation. c) Drain pipe. d) Suitable size of PVC pipe for protection covering of refrigent line if required as per direction of E-in-C. 2.0 TR capacity, 5 star rating
Supplying, installing, testing and commissioning of 5 KVA electronic voltage stabilizer suitable for 2.0 ton Air Conditioner as required equivalent to V-Guard Model No.VG 500 or its equivalent to ISI standard.
Provoding & fixing of pre-fabricated stand for keeping outdoor units of 1.5 Ton/ 2 Ton Capacity split type AC as required.
AKABEA INFRASTRUCTURES PRIVATE LIMITED (BID ID -45368)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .