Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹41.6 L+₹3.6 L (9.35%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹41.8 L+₹3.8 L (9.90%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹41.9 L+₹3.8 L (10.1%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹41.9 L+₹3.9 L (10.2%)Rejected-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L5 | Rejected-Finance High Rate |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
1 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8315 REPAIR REPLACEMENT MAINT OF LT ELECTRICAL DISTRIBUTION SYSTEM AND OTHER CONNECTED ITEMS AT AFMC AND ALLIED AREA UNDER GE (CENTAL) PUNE
2022_MES_524552_1
8315 REPAIR REPLACEMENT MAINT OF LT ELECTRICAL DI
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (Central) Pune
As per tender NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Pune
₹78,000
Yes
23 Jul 2022
17 May 2022
3 Jun 2022
17 May 2022
1 Jun 2022
24 May 2022
60 days
Amount
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of LT UG cable in soft/loose soil and getting out complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soil all as specified & directed.
Removing excavated material to a distance n.exc 50m and depositing where directed at level not exceeding 1.5m above the starting point all as specified & directed.
M & L for Reinforced concrete pipes of dia 150 mm 2 nos half round (each of 1 RM long for bottom and top ) and before laying excavated area shall be levelled all as specified and directed.
M & L GI Tubes, 'light grade', galvanised, with all fittings laid in trenches of size 50 mm dia.
M & L GI Tubes, 'light grade', galvanised, with all fittings laid in trenches of size 80 mm dia.
Cutting of road/hard standing and making good with PCC (1:2:4) type B 1 using 20mm graded stone aggregate complete all as specified.
Taking down old unserviceable/worn out LT UG Cables of any type and size complete all as specified.
Supply, laying, testing and commissionnig of LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete 16 sqmm 4.0 core
All as per item no. 9 above but of size 25 sqmm 4.0 core
All as per item no. 9 here in before but of size 50 sqmm 3.5 core
All as per item no. 9 here in before but of size 70 sqmm 3.5 core
All as per item no. 9 here in before but of size 95 sqmm 3.5 core
All as per item no. 9 here in before but of size 120 sqmm 3.5 core
All as per item no. 9 here in before but of size 185 sqmm 3.5 core
All as per item no. 9 here in before but of size 300 sqmm 3.5 core
M & L for MCCB 63 Amps, 16KA, TP 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
M & L for MCCB 100 Amps, 16KA, TP 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
M & L for MCCB 125 Amps, 25KA, TP 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
M & L for MCCB 200 Amps, 25KA, TP 415 Volts with adjustable thermal and adjustable magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
M & L for MCCB 63 Amps, 16KA, TPN 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
M & L for MCCB 160 Amps, 25KA, TPN 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
M & L for MCCB 250 Amps, 25KA, TPN 415 Volts with adjustable thermal and adjustable magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
M & L for MCCB 400 Amps, 36KA, TPN 415 Volts with adjustable overload and adjustable shortcircuit with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable Weather proof flat twin core cable of size 16 sqmm nominal cross section in service connections
Supply, installing, testing and commissioning factory made and tested (CPRI certified) LT Panel outdoor type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bars of rating 1200 amps installed on porcelain insulators. The panel shall be dust and vermin proof IP-65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type, with apron for cable entry with single door shutter and locking arrangement all including PCC and earth work etc. after taking down old us panel and comprising of the following :-
(a) Incoming :-
MCCB 4 pole 36 KA, 630 Amps capacity 415 V, 50 Hz, with O/L & S/C protection, AC supply complete with all standard accessories - 01 Nos
(b) Outgoing
(i) MCCB TPN 400A, 36 KA - 01 No
(ii) MCCB TPN 250A, 25 KA - 02 No
(iii) MCCB TPN 160A, 25 KA- 02 Nos
(vi) Indicator lamps Red/Yellow/Blue - 03 Nos
Supply, installing, testing and commissioning factory made and tested (CPRI certified) LT Panel outdoor type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bars of rating 1200 amps installed on porcelain insulators. The panel shall be dust and vermin proof IP-65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type, with apron for cable entry with single door shutter and locking arrangement all including PCC and earth work etc. after taking down old us panel and comprising of the following :-
(a) Incoming :-
MCCB 4 pole 36 KA, 630 Amps capacity 415 V, 50 Hz, with O/L & S/C protection, AC supply complete with all standard accessories - 01 Nos
(b) Outgoing
(i) MCCB TPN 400A, 36 KA - 01 No
(ii) MCCB TPN 250A, 25 KA - 02 No
(iii) MCCB TPN 160A, 25 KA- 02 Nos
(vi) Indicator lamps Red/Yellow/Blue - 03 Nos
Supply, installing, testing and commissioning factory made and tested (CPRI certified) LT Panel outdoor type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bars of rating 1000 amps installed on porcelain insulators. The panel shall be dust and vermin proof IP-65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type, with apron for cable entry with single door shutter and locking arrangement all including PCC and earth work etc. after taking down old us panel and comprising of the following :-
(a) Incoming :-
MCCB 4 pole 36 KA, 630 Amps capacity 415 V, 50 Hz, with O/L & S/C protection, AC supply complete with all standard accessories - 01 Nos
(b) Outgoing
(i) MCCB TP 200A, 25 KA - 02 No
(ii) MCCB TP 100A, 16 KA - 02 No
(iii) MCB 2 pole 40 Amps 10 KA capacity- 02 Nos
(vi) Indicator lamps Red/Yellow/Blue - 03 Nos
Supply, installing, testing and commissioning factory made and tested (CPRI certified) LT Panel outdoor type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bars of rating 1000 amps installed on porcelain insulators. The panel shall be dust and vermin proof IP-65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type, with apron for cable entry with single door shutter and locking arrangement all including PCC and earth work etc. after taking down old us panel and comprising of the following :-
(a) Incoming :-
MCCB 4 pole 25 KA, 250 Amps capacity 415 V, 50 Hz, with O/L & S/C protection, AC supply complete with all standard accessories - 01 Nos
(b) Outgoing
(i) MCCB TP 100A, 16 KA - 04 No
(ii) MCCB TP 63A, 16 KA - 02 No
(iii) MCB 2 pole 40 Amps 10 KA capacity- 04 Nos
(vi) Indicator lamps Red/Yellow/Blue - 03 Nos
Supply, installing, testing and commissioning factory made and tested (CPRI certified) LT Panel outdoor type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bars of rating 400 amps installed on porcelain insulators. The panel shall be dust and vermin proof IP-65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type, with apron for cable entry with single door shutter and locking arrangement all including PCC and earth work etc. after taking down old us panel and comprising of the following :-
(a) Incoming :-
MCCB 3 Pole 25 KA, 100 Amps capacity 415 V, 50 Hz, with O/L & S/C protection, AC supply complete with all standard accessories - 01 Nos
(b) Outgoing
(i) MCB TPN 63A, 16 KA - 05 No
(iv) Indicator lamps Red/Yellow/Blue - 03 Nos
Material and labour for servicing and repairing LT distribution panel installed at various substation, including dismantling incomming & outgoing cable connections from feeders/ switch gears, S&F heat shrinkable cable sleeves and insulation taping properly on cable. Replacement of cable end terminals (lugs) of appropriate size, replacement of U/s Nut bolts washers etc., replacing unserviceable indicator lamp R Y B, repairing to panel wiring including Panel door repair, hinges, locking system etc., Reconnecting all elect connections, earthing connections checking throughly and made all feeders serviceable as directed.
S & F in repairs Indicator lamps Red/Yellow/Blue (set of three)
M & L preparing old painted surfaces by scraping and removing old paints, rust etc. from LT Panel/feeder pillar, painting with synthetic enamel paint (two coats) complete all as specified and directed.
M & L in repairs for cable jointing kit for 1.1 KV grade cable for outdoor, heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of following sizes:-
(a) 25 to 50 sqmm
(b) 70 to 120 sqmm
(c ) 150 to 185 sqmm
M&L for earthing for sub station equipments (Transformer, lightning arrestor and feeder pillar box) complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of equipments etc at the other, earth strip encased in and including 40mm bore GI medium grade pipe with all fittings from top of electrode to body of equipment fixed with and including 40 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work , etc.complete all as specified and shown in electrical plate No 3 of SSR Pt-I.
Note : 1. Refilling of the earth pit shall be carried out with black cotton soil. 2. GI strip 32 x 6 mm & GI protection pipe upto 7.5 m length will be measured under this item.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Supply and laying graded coarse aggregate of nominal size 12.5 mm in out door LT Panels complete as specified and as directed.
Supply only Bricks; common burnt clay building bricks, sub-class ‘B' designation 75 modular bricks
Dismantling/ taking out LT UG cables from pipe/ trenches /ducts/ floors after disconnecting U/S existing cable all as specified and direced.
S&F in repair 1.6 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc.
Supply only water soluble soil Reactivation Earthing compound, Hydrate crystalline Gel earthing compound DSS earth recharge in 6 Kg bucket
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .