| 1 | 1₹31.0 LAccepted-AOC 58 SHAHEED NAGAR OPP BHIMRAO AMBEDEKAR UNIVERSITY RBL ROAD LUCKNOW 226025 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226025 | 1 | Accepted-AOC Acceptance Of Tender | |
| 2 | 2₹31.1 L+₹12,401.11 (0.40%)Rejected-Finance | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹34.5 L+₹3.5 L (11.3%)Rejected-Finance | 3 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | M/S PERFECT CONSTRUCTION CO. L2 | m/s raghubar dayal L3 | M/S S S A ASSOCIATES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Surface excavation not exc 30 cm deep averaging 15 cm deep and getting out in soft/ loose soil. | 630 | Sqm | 20 ₹12,600 | 60 ₹37,800 | 15 ₹9,450 Lowest |
| 2.00 | Excavation in trenches not exc 1.5 mtr wide & not exc. 1.5mtr depth for foundation, manholes etc and getting out soft/loose soil complete all as specified and directed. | 92 | Cum | 110 ₹10,120 Lowest | 300 ₹27,600 | 110 ₹10,120 Lowest |
| 3.00 | Returning filling in cluding spreading levelling watering and well ramming in layers not exc 25cm in hard dense soil. | 20 | Cum | 50 ₹1,000 Lowest | 100 ₹2,000 | 60 ₹1,200 |
| 4.00 | Removing excavated material not exc 50mtrs and depositing where directed at level not exc 1.5 mtrs above trhe starting point all as specified. | 72 | Cum | 50 ₹3,600 Lowest | 160 ₹11,520 | 60 ₹4,320 |
| 5.00 | M & L PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation or mass concrete etc complete all as specified. | 7 | Cum | 3,000 ₹21,000 Lowest | 4,000 ₹28,000 | 3,600 ₹25,200 |
| 6.00 | M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius built in cm 1:4 | 60 | Cum | 4,500 ₹2,70,000 Lowest | 5,500 ₹3,30,000 | 4,500 ₹2,70,000 Lowest |
| 7.00 | M&L for RCC M25 (20mm graded stone aggregate) design mix as in foundation, including raft footings, foundation beams, plinth beams bases for columns etc complete all as specified and as directed. | 22 | Cum | 6,500 ₹1,43,000 | 8,500 ₹1,87,000 | 6,150 ₹1,35,300 Lowest |
| 8.00 | M&L for RCC M25 (20mm graded stone aggregate) design mix as columns. | 33 | Cum | 6,780 ₹2,23,740 | 8,800 ₹2,90,400 | 6,150 ₹2,02,950 Lowest |
| 9.00 | M&L for RCC M25 (20mm graded stone aggregate) design mix as in lintel/roof beams etc. | 17 | Cum | 7,000 ₹1,19,000 | 9,500 ₹1,61,500 | 6,150 ₹1,04,550 Lowest |
| 10.00 | M&L for RCC M25 (20mm graded stone aggregate) design mix as roof Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like | 25 | Cum | 7,000 ₹1,75,000 | 9,500 ₹2,37,500 | 6,150 ₹1,53,750 Lowest |
Tender Value
₹38.8 L
EMD Value
₹77,640
Closing Date
27 Sept 2025, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
PROVN OF ORD, RATION AND OFFICE STORE AT HQ 41 INF BDE CAMP UNDER GE (EAST) LUCKNOW.
2025_MES_728532_1
CWE/LKO/E/T-60 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE East LUCKNOW
₹77,640
Yes
3 Dec 2025
30 Aug 2025
4 Oct 2025
30 Aug 2025
27 Sept 2025
13 Sept 2025
30 Aug 2025 - 13 Sept 2025
Amount
Surface excavation not exc 30 cm deep averaging 15 cm deep and getting out in soft/ loose soil.
Excavation in trenches not exc 1.5 mtr wide & not exc. 1.5mtr depth for foundation, manholes etc and getting out soft/loose soil complete all as specified and directed.
Returning filling in cluding spreading levelling watering and well ramming in layers not exc 25cm in hard dense soil.
Removing excavated material not exc 50mtrs and depositing where directed at level not exc 1.5 mtrs above trhe starting point all as specified.
M & L PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation or mass concrete etc complete all as specified.
M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius built in cm 1:4
M&L for RCC M25 (20mm graded stone aggregate) design mix as in foundation, including raft footings, foundation beams, plinth beams bases for columns etc complete all as specified and as directed.
M&L for RCC M25 (20mm graded stone aggregate) design mix as columns.
M&L for RCC M25 (20mm graded stone aggregate) design mix as in lintel/roof beams etc.
M&L for RCC M25 (20mm graded stone aggregate) design mix as roof Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L for RCC M25 (20mm graded stone aggregate) design mix as chajja.
M&L 15mm thick rendering in (CM) 1:4 on fair surfaces of brick walls finished even and smooth without using extra cement.
M&L 15mm thick rendering in cm 1:6 on other than fair surfaces of brick walls finished even and smooth w/o using extra cement all as specified.
M&L 5 mm thick plaster in CM (1:3) in ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L preparation of new plaster surfaces of wall and applying two coats of oil bound distemper ovr one coat of wall care puty 1mm thick on walls with alkali resistant primer all as specified.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint complete all as specified.
M&L preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C2 , 75 mm thick as in plinth protection smooth without using extra cement incl cutting joints at every 3 m & at corner, Joints to be filled with mastic bituminous.
M&L for hard core of broken stone or boulders of gauge n. exc. 63 mm, deposited, spread and leveled in layers n. exc. 15 cm thick, watered and rammed to a true surface.
Formwork to sides of footings of concrete foundation with rough finished surfaces of concrete complete all as specified and directed.
Formwork to sides of columns with rough finished surfaces of concrete complete all as specified and directed.
Formwork to sides and soffits of lintels & beams including supports overhangs etc with rough finished surfaces of concrete.
Fromwork to roof slab with projection including edges with rough finished surfaces of concrete complete all as specified and directed.
Fromwork to chajjas, troughs and similar items including edges for rough finished surfaces of concrete complete all as specified and directed.
M&L TMT 6mm to 8mm dia cut to length, bent to shape required incl. cranking, bending and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M&L TMT 10mm dia and over cut to length, bent to shape required incl. cranking, bending and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M&L 100mm thick PCC type D-2 1:4:8 (40mm graded stone aggregate) for sub base.
M&L PCC 40 mm thick 1:2:4 of type B0 using 12.5mm graded stone aggregate as in base of floors complete all as specified and as directed.
M&L for single piece machine cut kota stone slab flooring 19-20mm thick as in Window cill and steps over cement screed bed 15mm thick in CM 1:6, base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L for machine cut kota stone slab flooring 19-20mm thick over cement screed bed 15mm thick in CM 1:6, base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 30mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand
M&L for 15mm thick on fair faces of concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound finished even and smooth without using extra cement . (Liquid water proofing compound to be measured paid separately) complete all as specified and directed.
Supply only Liquid water proofing compound complete all as spesified and directed.
M&L for water proofing treatment to roof and edges (Vertical or tapered ) etc. in following sequence (i) Properly cleaning and drying the surface. (ii) Applying a coat of bitumen primer 85/25 (VG-40) grade confirming IS702 @ 1.2 Kg /sqm. (iii) laying APP based polymetric membrane minimum weight 3 kg/sqm and minimum 3 mm thick reinforced with polyster non woven fabric(wt not less than 150 gms/sqm) with 100 mm over lap laid on primed surface by sealed and bonded to the surfaces by torchen method (iv) applying two coats of bitumen based @ 0.20 Kgs/Sqmaluminium painting on water proofing treatment all as specified.
S&F pressed steel frames of size 105X60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified.
M&L cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as for filling in door frames etc complete all as specified and as directed.
S&F 30mm thick flush shutters solid core construction with block board core and plywood face panels commercial type on both sides.
Providing & fixing windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52 x 25mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy-duty stain less steel pivot hinges shall be provided per shutter. The windows should be panelled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self-expanding, screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished item of work including of all taxes.
S&F Butt hinges 125 mm stainless steel hinges medium weight and fixed
S&F 125 mm stainless steel pressed handles, oval type, stove enamelled black
S&F 300 mm long stainless steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed
S&F for stainless steel barrel tower bolts 200 mm of extruded section and fixed.
S&F M.S framed work such as grills grating etc with ends of bars sholdered and /or riveted into spikes framed guard bars/railing all as specified.
M&L for preparation of new steel and iron surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of primer all as apecified and directed
M&L treating the soil under plinth protection at the rate of 5 litre of emulsion per square metre of surface area
Treating the back fill in contact with foundation at the rate of 7.50 litre of emulsion per square metre of vertical surface (area of sub structure in contact with back fill to be measured)
Treating the top surface of filled earth rate of 5 litre of emulsion per square metre of surface area
M&L for earth filling (incl approved earth brought from out of defence land) ,spreading, leveling & compecting n exc. 30 cm thick Layer, watering, ramming/rolling and finishing to required size, shape,etc.n exc. 1.5m high from base.
Material and Labour for point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed multi stranded copper conductor single core cable 1100 volts grade in and including PVC conduit with accessories including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light/Ex-fan point controlled by one switch 5Amps SP all as specified and directed. Note :- Sunken box/cover plate for modular switches, sockets etc will be measured and paid seperately under relevant items and blank plate required if any will be deemed included in the item rate.and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall all as specified.
All as per Item No 49 but point wiring with 2.5sqmm hereinbefore but for One 5 A socket outlet on independent Board all as specified and directed.
All as per Item No 49 hereinbefore but for One 5 A socket outlet on same Board all as specified and directed.
All as per Item No 49 hereinbefore but point wiring complete with 2.5 sqmm for 3 pin 15 A socket outlet on independent board including 2.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor all as specified and directed.
Supply and fix frame plate with match cover twelve module all as specified and directed.
Supply and fix frame plate with match cover six module all as specified and directed.
All as per item above but three module all as specified and directed.
Supply and fix terminal box suitable twelve modular plat of size 75X75x50 mm including cutting, grooving and plastering etc. all as specified and directed.
Supply and fix terminal box suitable six modular plat of size 75X75x50 mm including cutting, grooving and plastering etc. all as specified and directed.
All as item No above but three modular plat of size 100X75x50 mm including cutting, grooving and plastering etc. all as specified and directed.
Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.PVC pipe 25 mm dia for protection of cables all as specified and directed by Eng-in-Charge
Supply and fix GI Pipe light grade 80 mm dia for protection of cables all as specified and directed by Eng-in-Charge
Supply and fix Modular switch one way 6A 230V AC 50 HZ SP one module all as specified.
Supply and fix Modular switch one way 16A 230V AC 50 HZ SP one module all as specified.
Supply and fix Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified.
Supply and fix Modular socket 6A/16A 2/3 pin combined 230V AC 50 HZ SP two module all as specified.
Supply and fix in repair of MCB DB SPN 8 way double door type suitable for TP/FP including necessary dummy plate and necessary civil works all as specified and directed.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 63 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SPN, AC, 240 volt of 40 Amp, "C" curve, 10 KA breaking capacity - 16 Nos.
Supply and fix MCB SP 230V, 6-32 Amps capacity all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning 40 to 63 Amp capacity all as specified and directed.
Supply and fix Modular Regulator 230V AC 50 HZ SP two module all as specified.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core all as specified and as directed by the Engr-in-Charge.
M &L for Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified and directed.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
M &L for Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning for protection of cables complete all as specified and directed.
Supplying & laying common bricks sub class B for LT cable for protection of cable complete all as specified and directed.
S&F Ceiling rose PVC polycarbonate all as specified and directed.
Supply and fixing of wall/surface mounted integrated batten LED light luminaire of 4ft length with a system wattage of 20-22W with a nominal system lumen output of 2000-2200 lumens and a minimum system efficacy of 100Lm/W. CCT shall be 6500K and CRI ≥ 80. Housing shall be extruded aluminimum with powder coating & with IP20 protection, The luminaire shall meet IP20 rating with surge protection of 2.5KVA, THD ≤10% and PF ≥ 0.95,
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed. Note:- Down rods of suitable length( 4feet,5 feet or 6 feet) is incl in the item rates and no extra payment will be done to the contractor for the same.
Supply and fixing in replacement of Solar integral AIO streetlight with Aluminium housing, reliable & robust construction with IP65 & IK08 protection. The luminare Lithium /LifePo4 Battery capacity min [email protected] or 20w4.5v pv panel power CRI >=70, System Efficacy >165lm/W, & Minimum Lumen 4000 system wattage should not be more than 25W ± 2%, if wattages increases then the size of battery & panel shall also be increased in similar percentage to maintain equal autonomy of the system. Weight not more than 2.32 kg . The fixture should have in microwave motion sensor &sensor dealy time 18 seconds Life class of LED 50000hrs@ incl clamps ,brackets and nut-bolts and other connected items for fixing the light on wall complete all as specified and directed by the Engr-in-Charge.
Supply and fix 45W Pressure die cast aluminium housing street light with system lumen of 6300 lm and system efficacy of 140 lm/w, IP-66,IK-10 single piece die cast incl spigot, dia 48-76mm,LED lifetime (L70B50) 75k Hrs with integrated optical cover. Street light should have standalone lighting control system with AUTO ON/OFF based on DUSK/DAWN timings,preset time settings with monthly variations (Jan to Dec), inbuilt real time clock for switching, incleds dimming profile for energy savings,drift not exceedind max 2mins/year, clock retention upto five yeras, auto switching off secondary power for module,dimmable driver based on PWM control, dim to off with high/low voltage cut off with 440V protection for 8 hrs for complete luminiarie incl driver and astro module,surge protection as perIEC 61000-4-5 incl clamps ,brackets and nut-bolts and other connected items for fixing the light on wall all as specified and directed by engineer in charge.
Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 6 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 6 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings all as specified and directed.
Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 4 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 4 Sqmm drawn through and including PVC Conduit pipe 25 mm dia with all fittings all as specified and directed.
Material and labour Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 B1 with 8 mm dia MS rounds 1.5 kgs, funnel ,watering pipe etc. all specified and directed including testing on completion all as specified and directed.
Supply and fixing Exhaust fan steel body 380/450 mm sweep working on single phase supply incl. all accessories including electrical connection with required wire complete all as specified and directed.
M/S PERFECT CONSTRUCTION CO. (BID ID -3430357)
m/s raghubar dayal (BID ID -3429443)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .