| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC 2 B KRISHNA NAGAR AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹15.2 L+₹4,072.50 (0.27%)Rejected-Finance 8 SHARMA ESTATE LOHGARH ZIRAKPUR SAS NAGAR PB 140603 | S A S NAGAR | PUNJAB | 140603 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹16.5 L+₹1.4 L (9.31%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹16.7 L+₹1.6 L (10.4%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹18.9 L+₹3.8 L (24.9%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹17,000
Closing Date
17 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Sidhartha Singhal
GE (P) Dappar
Repair to roof, ceiling, plinth protection, CGI sheets, rain water pipes, PVC water storage tanks etc in Domestic area at Mil Stn Dappar under GE (P) Dappar
2021_MES_437211_1
GE (P) DPR-05/2021-22
Open Tender
Civil Works
Works
180 days
GE (P) Dappar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) Dappar
₹17,000
Yes
19 Aug 2021
19 Apr 2021
19 May 2021
19 Apr 2021
17 May 2021
1 May 2021
19 Apr 2021 - 1 May 2021
60 days
Amount
Dismantling of brick tiles or terracing tiles single layers on roof complete all as specified and as directed.
Demolition of mud phuska on roof any thickness all as specified and as direcxted.
Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed.
M&L for PCC 1:3:6, type B-0 using 12.5mm graded stone aggregates as in padding over roof, to maintain a slope of 1:100 ,complete all as specified and directed by Engr-in-Charge.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specifiedand directed by Engr-in-Charge.
M&L for PCC 1:2:4 using 12.5mm graded stone aggregates, steps; seismicand other similar bands, plinth courses, string courses, parapets and copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed and directed by Engr-in-Charge.
M&L for providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm th 5 layered APP membrane shall be laid using butane torch and sealling all joints etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength inlongitueinal and transverse direction at 23 degree C as 650/450N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 250 N/. Softening point of membrane not less than 150 degree C Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147) (iii) The laying of membrane shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed and as directed by Engr-in-Charge. Make : Sika/STP/Fosroc Note : 10% of the amount of water proofing treatment items shall be kept reserverd and contractor shall give 10 years written guarantee for water proofing. However contractor can deposit a FDR of same amount and if contractor fails to rectify the defects occured during this period the same shall be get rectified at contractor's risk and cost and payment shall be made by encashing the FDR deposited for this purpose.
M&L for 20-22mm thick precast plain cement concrete tiles type B-1, 1:2:4 (12.5mm graded aggregate) as in flooring , roofing set in cement mortar 1:4 over and including 15mm th screed bed in CM 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L for 15mm thick rendering on roof of brick or concrete surfaces in CM 1:4 finished even and fair mixed with water proofing compound as per manufacturer's instructions complete all as specified and as directed by Engr-in-Charge.
Supply only integral liquid water proofing compound. Make : Pidilite/Sika
M&L Providing and laying 4mm (-0.2/+0.3) thick APP with mineral finish (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 5.6 Kg/sq.m water proofing membrane mineral finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps over the coat, 4mm th 5 layered APP membrane mineral finish shall be laid using butane torch and sealling all joints etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Tensile strength in longitueinal and transverse direction as 600±150/400±150 N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 200 N/. Softening point of membrane not less than 145 degree (iii) Penetration @25 C d 15-25mm (iv) Water Tightness 10 kPa (v) The laying of membrane shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. Make : Sika (WP Shield 104 PM) or equivalent from STP/Fosroc Note : 10% of the amount of water proofing treatment items shall be kept reserverd and contractor shall give 10 years written guarantee for water proofing. However contractor can deposit a FDR of same amount and if contractor fails to rectify the defects occured during this period the same shall be get rectified at contractor's risk and cost and payment shall be made by encashing the FDR deposited for this purpose.
Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified.
M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 complete all as specified and as directed by Engr-in-Charge.
M&L brick work with sub-class `B' bricks , straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
Taking down cement plaster of any description, any thickness from external/ internal surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and as directed.
M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair without using extra cement cxomplete all as specified and as directed. Note : WPC will be measured and paid separately.
M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed. Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order.
M&L applying 02 coats of exterior emulsion paint dark shade) @ 5 sq.m/litre/2 coats by using roller/brush to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and as directed. Make of Exterior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Exterior Emulsion : Asian (ACE) / Berger (WALMASTA) / Nerolac (SURAKSHA SUPERIOR)
Disconnecting existing tanks, setting aside (or lowering if required) for repairing, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning the tanks complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position or water srorage tanks of any size/capacity/description/position located on terrace of the building including removing of the demolition material/debris to low lying area or out of defence land all as specified and directed.
S&F trippled layered rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top / cover) 500 Ltrs capacity hoisted and fixed in position including ball brass valves of 20 mm bore, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC tank complete all as specified and as directed by Engr-in-Charge. Make - Sintex, Rotex, DI-Plast, Sheetal, vectus, Polycon
Taking up or down existing steel tubing and connections, 20mm bore complete all as specified.
Refixing 20mm bore steel water tubing obtained from taking down with all fittings and fixed complete to walls and ceiling or laid in floor etc and incl cutting chases if required for concealed water tubing and making good, cutting not exc 10 cm girth etc complete all as specified and as directed by Engr-in-Charge.
S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc and incl cutting chases if required for concealed water tubing and making good, cutting not exc 10 cm girth etc complete all as specified and as directed by Engr-in-Charge.
S&F 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
Dismantling of asbetos cement corrugated or semi corrugated/fibre glass reinforced translucent corrugated sheets in roof covering fixed with ‘J’ or ‘L’hooks complete all as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of Tile Profile having TCT 0.45mm thick, rib height 28mm, Min. G550 Mpa Grade, pitch 200mm with 16mm step depth, of colour as approved as in roof covering, including supply and fixing of ridge of plain sheet 0.5mm thick of same colour, material and manufacturer fixed with fasteners/screws as recommended by manufacturer complete all as specified and directed by Engr-in-Charge. Note : Fixing of sheets will be done strictly according as per manufacurer's instructions. Make : Indian Ispat, TATA Blue scope, JSW, Bhushan Galvacolor, Prestar, A one Industries, CRIL.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of 0.5mm thick, rib having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engr-in-Charge. Note : Fixing of sheets will be done strictly according as per manufacurer's instructions. Make : Make - Indian Ispat, TATA Blue scope, JSW, Bhushan Galvacolor, Prestar, A one Industries, CRIL.
S&F PVC(HDPE) SWR , 110 mm bore, single socketed in any length with rubber ring joints using solvent as per maunfacture instruction, fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc as in repairs complete all as specified and directed and directed by Engr-in-Charge. Make : Astral / Prince / Finolex
S&F PVC(HDPE) SWR , 110 mm bore, bends any radius complete all as specified and directed and directed by Engr-in-Charge. Make : Astral / Prince / Finolex
Demolition of cement concrete un-reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified.
M&L for cement concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and smooth without using extra cement including provision of construction joints and filling with compound of grade 'A' complete all as specified and as directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified.
(a) S&F false ceiling of 12.5mm th gypsum board over and including concealed grid system complete fixed in all respect and all as per manufacturer's instructions in one/two/three levels and making recess for light fittings as per pattern/design approved by AO and including supply and fixing of items all as specified as below :- Note : The complete item shall be got executed through the authorised applicator of manufacturer only all as specified and directed. Make : Gyproc (b) S&F Suspended Plain Ceiling includes Perimeter Channel {Material-GI(IS513),YS-260Mpa,Finish- Galvanised 150GSM(IS27 )} is fixed along the perimeter of existing wall/ partition with the help of HILTI HPS - 1 (6x40) impact anchor, at 600mm centres. Make : Gypserra™ (c) S&F Ceiling Angle {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is suspended by fixing it to the Gyproc® soffit cleat {GI(IS513)YS-260Mpa,Finish-Galvanised 150GSM(IS277) }. Soffit Cleat and Gyproc® Rawl Plug- Ø8x45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1220mm x 1220mm grid. Make : Gypserra™ (d) S&F Intermediate channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277) } is fixed to the Ceiling Angle with M6 x 12mm Hex Bolt & Hex Nut arrangement {Material–As per EN 10083 Finish – Zinc Plating} or with 2 Nos of Ø4.2x13 Gyproc® metal to metal screw {Material-Carbon steel EN-ISO 7049/50 Finish- Zinc Coating Thickness- 4.14micron.} Make : Gypserra™ (e) S&F Ceiling Section {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} is then fixed to the Intermediate Channel {Material-GI(IS513),YS-260Mpa,Finish-Galvanised 150GSM(IS277)} with the help of Gyproc® Connecting Clip {Material-High carbon spring steel wire(BS970Gr.En42)-46-48HRC,Finish- Zinc plating 4-6 micron} and in direction perpendicular to the Intermediate channel at 457mm c/c. Make : Gypserra™ (f) S&F Single layer of 12.5mm tapered edge Plain (conforming to IS 2095-Part 1:2011, ISI Certified board) is then screw fixed to ceiling section with 25mm drywall screws {Material-Carbon steel EN-ISO 7049/50,Finish-Case hardened Grey Phosphating} at 230mm centres on ceiling section & 150mm at periphery of ceiling. Make : Gypboard® (g) Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Pro-Fill Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape. Make : Gyproc®
Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and as directed.
S&F Plates Fe 410-W(Gde-E-250 quality- A) Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicatedcomplete all as specified.
M&L for excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil all as specified.
S&F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long of dia neck n exc 12mm and directed by Engr-in-Charge.
M & L for preparing steel and iron surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge. Make : Asian Paints/Berger/Nerolac
M&L for PCC 1 : 2 : 4,type B1 using (20mm graded aggregate) as in post and struts all as specified and as directed by Engr-in-Charge.
Taking down eaves gutter and rain water pipes including all fittings any size and pattern all as specified.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
M AND H BUILD TECH
singh traders
Swami Engineers
Swami Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .