Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical H NO 196 LAJPAT NAGAR FATEHABAD HARYANA 125050 | HISAR | HARYANA | 125050 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 3835 8B INDIRA COLONY NEAR LAHORIA 125001 | HISAR | HARYANA | 125001 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical 849 V P O BUPANIA TEHSIL BADLI DISTRICT JHAJJAR HARYANA 124507 | BUPANIA | JHAJJAR | HARYANA | 124507 | Admitted-Fee/PreQual/Technical |
Tender Value
₹5.8 Cr
EMD Value
₹10 L
Closing Date
11 Jun 2026, 1:00 pmClosed
MANJU Punia
XEN Civil Gurugram
CONSTRUCTION OF COMBINED SDO and XEN OFFICE, HODAL UNDER (OP) CIRCLE PALWAL,DHBVN
2026_HBC_523230_1
2026BF8D1B9B 7071 4165 88EC E0D3316161761035DHB
Open Tender
Civil Works
Works
730 days
Hodel
2 documents required · 2 mandatory
₹4,900
₹10 L
Yes
14 Sept 2026
22 May 2026
12 Jun 2026
22 May 2026
11 Jun 2026
22 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Modular kitchen - Under counter storage cabinets:
Providing and fixing factory made modular kitchen cabinets in modular type knockable cabinet boxes with openable shutters and sufficient number of drawers made of 18 mm thk. ISI Marked comm. ply , all ply to be laminated with 0.8 mm laminate.All shelves should be supported on approved quality SS pins and shall be adjustable for different heights as per requirements.Shutters and drawers fascia shall be at least 18mm thic with laminate on both sides with 18mm wide 2mm thick PVC edge banding, All Shutters finished in high gloss acrylic of approved make- Rehau,Ornare,Senosan. The cabinet boxes of floor units will be supported by 100mm height vertical adjustable legs (Hettich make) which will be covered with PVC skirting (Rehau or equivalent make ) in brushed aluminum finish attached by hardware of skirting. The unit shall be fixed to the floor/ wall/slab using metal screws of appropriate size and rawl plugs. Only front face area of cabinets and skirting from floor to top of boxes shall be considered for measurement and payment. Cabinet boxes size would be varies from 400X560X710MM to 1000X560X710MM (approx.) and join together as per site requirements etc. | 9 | Sqm | - | - |
| 2 | Modular Kitchen - Overhead storage wall units:
Providing and fixing factory made modular kitchen cabinets in modular type knockable cabinet boxes with openable shutters and sufficient number of drawers made of 18 mm thk. ISI Marked comm. ply . all ply to be laminated with 0.8 mm laminate.All shelves should be supported on approved quality SS pins and shall be adjustable for different heights as per requirements.Shutters and drawers fascia shall be at least 18mm thic with laminate on both sides with 18mm wide 2mm thick PVC edge banding, All Shutters finished in high gloss acrylic of approved make- Rehau,Ornare,Senosan. The unit shall be fixed to the floor/ wall/slab using metal screws of appropriate size and raw plugs. Only front face area of cabinets and skirting from floor to top of boxes shall be considered for measurement and payment. Cabinet boxes size would be varies from 400X560X710MM to 1000X560X710MM (approx.) and join together as per site requirements etc. | 9 | Sqm | - | - |
| 3 | Workstation - Providing and placing HNI make `Connect` Linear Workstation 1350 L x 600 W x 1200mm Ht with pedestal unit, Frame is 50 mm thick and made of vertical Aluminium Extrusions and Horizontal Steel Members of 1.2 mm to 1.5mm thickness. The System is complete hollow system with space for wire reticulation . All the frames will be duly powder coated . All the frames are fastened together by means of M6 NUTS and BOLTS . All the frames are fitted with M10 leveling bolts.board.Raceway :-The raceway cover are sliding type and are integrally fitting inside frame and are made out of 0.8mm - 1mm thick CRCA steel and powder coated. The electrical raceway can be provided below worktop or above worktop.The tables Should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . The partition has two integrated raceway provided one at skirting level and another at the work surface level thus ensuring separation of power and networking cables. The free space available within raceway accommodates power, data and communication cables. The cable can be taken into the Frame from the floor from the bottom. Tiles: Fabric Tile: Constructed out of 5mm thick Medium Density Fiber Board (MDF) and covered with Fabric of choice. Laminate Tile: Made out of 5mm - 8mm thick Pre-laminated Medium Density Fiber Board (MDF) . Bottom Row of Steel Tile: Constructed out of 0.8mm CRCA sheet and finished in epoxy powder coating. Can be given with plain / perforations / embossed finishes.Magnetic tile: Constructed out of 0.8mm Galvanized sheet and covered with fabric of choice. Whiteboard marker tiles: Made out of 4mm MDF with 1mm glossy highly wear resistant face laminate . Total thickness is 5mm. Table tops and Gable ends are of 25mm thk Pre-laminated particleboards conforming to IS : 12823 Interior Grade.The Worktops should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . Specially designed powder coated M.S. brackets having 2mm thickness fixed to the partition frame support the tabletops. Gable ends are of 25mm thk. both side laminate (BSL) with 2mm PVC edge banding on front side. Gable Ends are fixed with 3mm thick MS brackets to Frame and with 3mm thick Brackets to Worktops. Sealed edge in table top and gable ends are with2mm thick PVC edge banding on Working side and 0.8mm thick edge banding on non working side. Each Workstation has 3Drawer Pedestal unit of size 400mm L x 450mm D x 680mm made up of 18mm thk. Prelam particle board conforming to IS : 12823 Interior Grade with 3 Drawer ( 2 Drawer plus 1 Filing ) with roller slide mechanism for 2 Drawers and Ball bearing slide for 1 Filng Unit . 10 year warranty . | 4 | Nos. | - | - |
| 4 | MDF Board 4mm thk fixed with nails complete in all respect | 200 | sqft | - | - |
| 5 | credit to work
Dismantled Iron from GI pipe | 200 | Kg. | - | - |
| 6 | Providing and Fixing of PVC Wall Panelling complete in all respect to the entire satisfaction of engineer in charge | 2,000 | sqft | - | - |
| 7 | credit to work
Dismantled Iron from old broken scraps | 4,320 | Kg. | - | - |
| 8 | Brick bat obtained from dismantling brick wall | 125.73 | cum | - | - |
| 9 | Brick obtained from dismantling brick wall | 30,271 | Each | - | - |
| 10 | 50MM THICK GI FRAME (FOR THICK PARTITION) for MDF : Providing and fixing metal system up to ceiling height, which includes frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 GSM, consisting of Boral U track 52mm wide having equal flanges of 30mm and 0.55mm thick (Base metal thickness) fastened to the floor slab and ceiling soffit using rawl plugs with screw at 600mm centers, with first and last fixing point at not greater than 50 mm from either end. Boral C studs 50mm wide having one flange of 34mm, other flange 36mm, lip size 6 mm and 0.55mm thick installed perpendicularly within the flanges of floor and ceiling channels located directly opposite to each other at not more than 610mm centers. Maintain 5 to 10mm gap between C Stud and web of U Track | 100 | Sqm | - | - |
stage.html
html • 0.03 MB
cancelled_1.pdf
pdf • 0.74 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.22 MB
BOQ_602162.xls
BOQ • 0.36 MB
hodald.pdf
PDF • 0.34 MB
corrhod.pdf
PDF • 1.26 MB
corrhodal.pdf
PDF • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .