Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.7 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹17.6 L+₹5.6 L (46.8%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | 2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹20.2 L
EMD Value
₹40,400
Closing Date
5 Apr 2022, 6:00 pmClosed
CWE AF GWALIOR
AF STATION GWALIOR
REPAIR MAINT OF DX TYPE CENTRAL AC PLANTS AND CONNECTED WORKS IN TECH AREA AT AF STN GWALIOR
2022_MES_511700_1
85022/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STATION GWALIOR
Class E and above and category c(i)
9 documents required · 9 mandatory
₹500
Garrison Engineer (AF) Tech Area Gwalior
₹40,400
Yes
21 May 2022
3 Mar 2022
8 Apr 2022
3 Mar 2022
5 Apr 2022
17 Mar 2022
3 Mar 2022 - 12 Mar 2022
Amount
Supply and fixing in replacement including testing of drier filter of refrigerant gas of any description and in any position complete all as specified and directed. Make : Sporlain/Danfoss
M&L for necessary tools/plants for finding leakage in condenser piping chiller system and rectifying defects including welding/bracing as necessary by arranging N2 gas for checking and oxygen gas for welding etc all as directed and testing for satisfactory operation of plant by the contractor complete all as specified and directed. Note:- (i) The rate quoted against item is deemed to be inclusive of labour for filling of refrigerant gas, However the refrigerant gas is issued under schedule B free for filling.
Dismantling and taking up unserviceable plate type heat exchanger (PHE) by disconnecting inlet and outlet chiller water pipe lines & gas circuit by brazing, disconnecting of sensors, air purge valve etc at 24 MMPU ESH central Air conditioning plant 33 TR complete all as directed.
Supply, install, testing and commissioning plate type heat exchanger (PHE) of model No F120THx94 /1P-SC-M16+42U/2x2"VIC (Item No-0149607.0) working on R-410 refrigerant gas suitable for 33 TR capacity Air cooled chiller unit (Make : SWEP) complete including flushing of pipe line and brazing as required all as directed for satisfactory operation of plant complete all as specified and directed.
Supply & install water temperature sensor (LWT & EWT) for air-cooled chiller unit of capacity 33TR including taking down existing water temperature sensor complete all as specified and directed.
M&L for de-scaling and cleaning of condenser pipe chiller chocked pipe, water circulating pipe lines ,valves, condenser (heat Exchanger) to cooling tower, circulating concentrated de-scaling solution (scale balaster -copper friendly chemical and neutralizer ) mixed with water in suitable proportion till the deposits/scale is removed to maintain required pressure, the chemical should be circulated through pump, cleaning the condenser and connected pipe and components (2/3 Units) of compressor by suitable size of drill rod, wire brush including dismantling and connecting all dismantled components in proper position after servicing/overhauling/greasing/cleaning and replacement of packing gasket 3mm thick, nuts, bolts with washer, testing of water line for leakage, complete all as specified and directed by Engineer-in-Charge for the following capacity AC plants :- Note :- Descaling solution shall be paid separately under relevant item of schedule "A".
Capacity of central AC Plant (2x50 TR + 1x 50TR standby) Chilled water type at 24/25 MMPU & RDM
Capacity of central AC plant (2x35 TR + 1x 35 TR standby) DX type at MMS
Capacity of (2x85 TR + 1x 85TR standby) Central AC plant Chilled water system at P-77
Capacity of ( 2x26 TR + 1x 26 TR standby) Central AC plant Chilled water system at Bomb dump & Mirage
Capacity of (2x11TR + 1x11 TR standby) central AC plant chilled water type FSP & NEW BOMB DUMP
Capacity of (2x11TR + 1x11 TR standby) package Type water cooled at Avonic Lab
Capacity of central AC plant (2x33 TR + 1x 33 TR standby) DX type at 26 MMPU
Capacity of ( 2x38 TR + 1x 38 TR standby) at WSA Bomb Dump
Capacity of central AC plant (2x37.5 TR + 1x 37.5 TR standby) at SES & LDP
Capacity of central AC plant (2x62 TR + 1x 62 TR standby) at EWS
Supply only scale blaster-copper friendly De-scaling chemical (in 50 ltrs sealed packing) complete all as specified and directed. Make:- Blue star /carrier/voltas
Supply only neutralizer to neutralize the effects of scale blaster (in 50 ltrs sealed packing ) complete all as specified and directed. Make :- Blue star /carrier/voltas
Disconnecting from system, strip opening of Reciprocating unserviceable compressors completely and re-assembling the dismantled Compressor with re-fixing the serviceable parts in position and replacement of the unserviceable/defective parts with new parts as required at site, connecting the compressor and making perfectly leak proof after cleaning the oil sump, oil pump, connecting rod, piston, liner, etc. and filling of compressor oil, charging of refrigerant gas to the required pressure and testing the compressor complete all as specified and directed by the Engineer-in-Charge for following make & model of compressors :-
Model SMC 2– 65 of make Accel.
Model SMC 4 – 100 of make Accel.
Model 5H46 of make VOLTAS.
Following spare parts for Accel make compressors Model SMC 2-65 & SMC 4-100 complete all as specified and directed :- Note : The element of fixing & testing of the items is deemed to be included in the rates quoted by the contractor under respective Schedule `A' item No. 9.01 & 9.02 here-in-before.
Supply only Connecting rod
Supply only Shaft seal assembly
Supply only Main bearing of suitable size
Supply only Half section bearing of suitable size (set of Two )
Supply only Cylinder liner
Supply only Piston
Supply only Oil pressure regulating valve
Supply only Oil pump assembly complete
Supply only Oil filter Assembly complete with filter mesh, housing, gasket, nut bolts etc.
Supply only Piston ring (Set of two)
Supply only Oil scraper ring
Supply only Bush with piston pin
Supply only Valve spring for suction, discharge valve plate
Supply only Discharge valve assembly
Supply only Nut 8MTx6.5mm (Spl)
Supply only Discharge valve retaining ring plate
Supply only Discharge valve seat
Supply only Discharge valve retaining plate
Supply only Gasket set complete for SMC -2- 65
Supply only Unloading ring with pin
Supply only Spring for unloading ring
Supply only Suction valve retaining plate
Supply only Suction valve retaining ring plate
Supply only Crank case heating element
Supply only Suction strainer
Supply only Safety valve
Supply only Chank shaft
Supply only Crank shaft grinding/polishing
Supply only Section valve reed set micro finish
Supply only Discharge valve reed set micro finish
Following spare parts for Make –Voltas compressors Model 5H46 complete all as specified and directed :- Note : The element of fixing & testing of the items is deemed to be included in the rates quoted by the contractor for respective Schedule `A' item No 9.03 here-in-before.
Supply only Connecting rod with bearing inserts
Supply only Seal end main bearing
Supply only Piston pin
Supply only Seal end bearing washer
Supply only Compressor ring
Supply only Seal end thrust washer
Supply only Pump end bearing washer
Supply only Oil Ring
Supply only Suction valve disc
Supply only D V Guide lock washer
Supply only S V spring
Supply only Valve lifter pin
Supply only Valve lifter spring
Supply only Seal cover plate
Supply only Lock ring
Supply only Felt filter
Supply only Nyloc nut
Supply only Discharge valve disc
Supply only Seal lock plate
Supply only D V spring
Supply only Seal assembly
Supply only Main bearing pump end
Supply only Gasket set
Supply only Oil pump package
Supply only Suction strainer
Supply only Safety valve
Supply only Valve plate assembly
Supply only Section valve reed set micro finish
Supply only Discharge valve reed set micro finish
Supply only Discharge valve assembly
Supply only Chank shaft
Supply only Crank shaft grinding/polishing
Supply only Back cover/DOME assembly
Uma engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .