| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-Finance BEING LOWEST | |
| 2 | L2₹9.5 L+₹1.7 L (21.7%)Accepted-Finance | L2 | Accepted-Finance OTHER THAN LOWEST | |
| 3 | L3₹10.1 L+₹2.3 L (29.9%)Accepted-Finance | L3 | Accepted-Finance OTHER THAN LOWEST | |
| 4 | L4₹11.9 L+₹4.1 L (52.6%)Accepted-Finance | L4 | Accepted-Finance OTHER THAN LOWEST |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
13 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF
GE AF LEH PIN-194101 CO 56 APO
PROVISION OF CERTAIN MINOR WORK REVENUE WORK AND LOW BUDGET WORK AT AF STATION UNDER GE AF LEH
2020_MES_361505_1
GEAF-14/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE AF Leh
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF LEH
₹27,000
Yes
7 Sept 2020
16 Jul 2020
15 Aug 2020
16 Jul 2020
13 Aug 2020
30 Jul 2020
60 days
Amount
M&L for point wiring for 5 Amp independent socket outlet controlled by one switch one way in & including PVC conduit or casing and capping as per site requirement using FRLS PVC unsheathed multistrand copper conductor cable 1.5 sqmm single core including 3 mm thick plastic laminated sheet cover and earth continuity insulated PVC unsheathed (green colour) 1.5 sqmm copper earth wire connected to common earth dolly complete all as specified and directed by Engr-in-charge. Make : Polycab/Finolex/Havells/Kalinga Note : wiring shall be done by using proper colour coding.
M&L for point wiring for 5 Amp independent socket outlet controlled by one switch one way in & including steel conduit with steel saddles as per site requirement using FRLS PVC unsheathed multistrand copper conductor cable 1.5 sqmm single core including 3 mm thick plastic laminated sheet cover and earth continuity insulated PVC unsheathed (green colour) 1.5 sqmm copper earth wire connected to common earth dolly complete all as specified and directed by Engr-in-charge. Make : Polycab/Finolex/Havells/Kalinga
All as per srl item No. 01 above but on same board.
All as per srl item No. 01 above but for 15 Amp independent socket outlet using 2.5 sqmm FRLS PVC wire.
All as per srl item No. 02 above but for 15 Amp independent socket outlet using 2.5 sqmm FRLS PVC wire.
S&F Switch Socket combination 5 in 1, 3 pin, 5 & 16 Amps flush type 230 volts.
S&F Switch Socket combination 2-in-1, 5Amps flush type 230 volts.
Material and labour for point wiring in steel conduit unsheathed multistrand copper conductor cable of 1.5 sqmm single core FRLS for one light/fan point controlled by one flame proof switch including continuouse earth continuity copper earth wire of same size connected to common earth dollycomplete all as specified and directed by Engr-in-charge. Note : (a) wiring shall be done by using proper colour coding.
M&L for sub main wiring with two run (for Phase & Neutral) of 6.0 Sqmm FRLS PVC sheathed, copper conductor cable, 1100 Volt and one run of copper earth wire 6.0 sqmm drawn through & including PVC casing and caping/ Steel conduit, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with casing caping shall be measured as one length. Make : Polycab/Finolex/Havells/Kalinga
M&L for sub main wiring with four run (for Phase & Neutral) of 6.0 Sqmm FRLS PVC sheathed, copper conductor cable, 1100 Volt, and two run of copper earth wire 6.0 sqmm drawn through & including PVC casing caping/ PVC Conduit whichever suitable at site, complete all as specified. Note: Copper conductor 4 run and 2 run of copper earth wire along with casing caping/ conduit shall be measured as one length. Make : Polycab/Finolex/Havells/Kalinga
M&L for sub main wiring with two run (for Phase & Neutral) of 4.0 Sqmm FRLS PVC sheathed, copper conductor cable, 1100 Volt and one run of copper earth wire 4.0 sqmm drawn through & including PVC casing and caping/ Steel conduit, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with casing caping shall be measured as one length. Make : Polycab/Finolex/Havells/Kalinga
M&L for sub main wiring with four run (for Phase & Neutral) of 16.0 Sqmm FRLS PVC sheathed, copper conductor cable, 1100 Volt, and two run of copper earth wire 16.0 sqmm drawn through & including steel conduit, complete all as specified. Note: Copper conductor 4 run and 2 run of copper earth wire along with casing caping shall be measured as one length. Make : Polycab/Finolex/Havells/Kalinga
S&F Sheet metal enclosure double door for DB's SPN 4 way 240 V having 200 A rated bus bar complete all as specified and directed by Engr-In-charge. Make : Havels/L&T/ABB/IndoAsian/Standard.
S&F Sheet metal enclosure double door for DB's SPN 8 way 240 V having 200 A rated bus bar complete all as specified and directed by Engr-In-charge. Make : Havels/L&T/ABB/IndoAsian/Standard.
S&F Sheet metal enclosure double door for DB's TPN 4 way 240 V having required rated bus bar complete all as specified and directed by Engr-In-charge. Make : Havels/L&T/ABB/IndoAsian/Standard.
S&F MCB SPN 32A 240 V -10 ka all as specified and as directed by Engineer-in-charge. Make : Havels/L&T/ABB/IndoAsian/Standard.
S&F MCB SP 6 to 32 Amps - 10KA 240 Volts all as specified and as directed by Engineer-in-charge. Make : Havels/L&T/ABB/IndoAsian/Standard.
S&F MCCB 100 Amp TPN/FP fixed type thermal magnetic type 415 volts 50 Hz 25 KA, complete with all accessories as required on site & as directed by engineer-in-charge.
S&F MCB 63 Amp TPN/FP fixed type thermal magnetic type 415 volts 50 Hz 25 KA, complete with all accessories as required on site & as directed by engineer-in-charge.
Supply and fixing factory made sheet metal enclosure DB VTPN 415V 4 way double door with 200 Amp rated copper bus bar IP-42 sheet steel enclosure horizontal type along with suitable size copper PVC cable sheathed cable for earth continuity and suitable for having 100 Amp MCCB as incomer and MCBs as outgoing complete all as specified and directed by Engr-in-charge. Make : C&S/Standard/Havells/L&T
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron steel wire of 4mm dia by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore light grade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed.
M&L for Earthing complete with copper plate 60×60cm ×3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
Material and labour for copper strip of 20mm x 3.15mm with screws/ washers etc. over PVC saddles/spacers on wall and roof of building or with MS clamps of suitable size along steel tubular pole complete all as specified and as directed by Engr-in-Charge.
Material and labour for air termination, single pointed, copper rod 12 mm dia and 300mm long screwed properly on copper strip complete all as specified and as directed by Engr-in-Charge.
Material and labour for test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hax. head screw complete all as specified and as directed by Engr-in-Charge.
Material and labour for maintenance free chemical earthing system complete with one No UL 464 approvrd copper bonded earth rod 17mm dia , 3.0 Mtr long electrode burried in ground to bore of 150mm dia , Vertically to a depth not less than 0.5 Mtr below normal ground level including provision to connect the earth continuity conductor with copper bonded earth rod as per manufacturer design or all as directed including 60 Kg NABLLAB certified back fill chemical compound for filling bore holes with Min 6.0 Kg of Hygroscopic Gel. The ground enhancement chemical may be used in place of back fill compound as required and manufacturer recommendation to obtain 1.0 Ohms earth resistance value. A layer of 250-300 mm soil ( Vegitable / Cotton soil) is also required out side earth bore including necessary ingredients and water during process to obtain desired value . The earthing copper strip of 20x3.0 mm up to length 7.5 Mtr upto test point from copper rod is also included. The scope included iron frame of size 20x20 mm fixed with hinged with pit cover of 300 x300 mm made of cast iron as per company standarad shall be as recommanded by manufacturer complete all as specified : Make;- JMV / Pargati electrocom / Enove. Note:- (i) Payment shall be made only after satisfactory testing to the entire satisfaction of GE. The contractor has made alternate earthing in case test result not found satisfactorywithout extra cost to the Govt quoted rates shall be deemed to included. (ii) Contractor shall submit one year guarantee for earth resistance below 2.0 Ohms and raeth neutral voltage less than that 2.0 volts.
Supply, installation, commissioning and testing of copper wound isolation transformer indoor type complete with standard fittings LT 433 Volts 3 Phase, 4 wire, oil immersed naturally cooled with external cooling tubes of capacity 25 KVA. Make- Volina or equivalent in AE/Electric field.
Supply, laying in trenches or fixed to poles or passing through pipes and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core.
Excavation, in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying under ground cable in any type soil and getting out complete all as specified & directed by Engineer-in-Charge.
Add to item No. 31 above for each additional 1.5m or part thereof in depth beyond the first 1.5m.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick all as specified & directed by Engineer-in-Charge.
Removal of surplus excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Sand cushioning to under ground cable with dry sand locally available 8cm thick before laying the cable and 15 cm above the cable, stretching and testing of cable complete all as specified & directed by Engineer-in-Charge.
Un-reinforced pre cast concrete cable covers class LV, type-1, flat, of size 250mm x 150 mm x 40mm all as specified & directed by Engineer-in-Charge.
Supply and laying earthing continuity aluminium strip of size 32mm x 6mm with saddles in a sitable distance complete all as specified and as directed.
S&F Steel tubing light grade galvanised of size 40 mm dia for cable protection, laying in trenchs/floors/wall complete all as specified & as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron strip of 32 x 6mm dia by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to equipment and testing on completion with including 15mm bore light grade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing strip from earth plate to eqipment common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed.
Supply, installation, commissioning and testing of copper wound isolation transformer indoor type complete with standard fittings LT 230 Volts single phase, naturally air cooled with external cooling fins of capacity 7.5 KVA. Make : Volina or equivalent as approved
S&F Switch flame proof rotary type with termination box in LM6, 16 Amps, single pole 250 volts
S&F LED flameproof tubelight fixture with and including tube rod 2 x 20 Watts with IP-65 protection, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor wire of suitable size complete all as specified and as directed by Engr-in-Charge.
S&F flameproof exhaust fan of size 450mm sweep including lowers with IP-66 protection, complete with all accessories pre-wired and connecting up with twin core twisted flexible copper conductor wire of suitable size complete all as specified and as directed by Engr-in-Charge.
Material & labour for cutting openings, through brick/stone walls built in cement mortar for exhaust fans of 450mm sweep and other openings, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core etc. to store and rubbish not exc. 50m, including forming jambs in CM 1:4 and making good to match existing wall finishes, complete all as specified and as directed.
S&F Ceiling rose 3 terminal size 50x65mm surface type 230 volts.
M&L Cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in foundation filling for poles.
M&L Cement concrete 1:2:4 type B-I (using 20 mm graded crushed stone aggregate) for coping of poles/road cutting patch work including necessary form work and finished the surface.
Supply and Fixing in replacement Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) including numbering of poles with paint and painting up to 1.5 meter above PCC benching of poles in black and white strips 5 number complete all as specified and directed by Engr-in-charge. Note- (Excavation, earth work and foundation concrete and coping etc will be measured and paid separately).
MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and inclusive of one coat of red oxide and one coat of aluminium paint including taking down existing unserviceable rusted/worn out MS cross arm, angle, clamps, nuts, bolts and washers etc complete all as specified and directed by Engr-in-charge.
osho traders
M/S JAVED CONSTRUCTION COMPANY
Path Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .