GE (AF) Amla
GE AF Amla, Betul Dist 460553 (MP)
REPAIRS TO WATER PROOFING TREATMENT AND LEAKAGE SEEPAGE IN DOMESTIC AREA AT AFS AMLA
2023_MES_617922_1
8554/E8 OF 23-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Amla
As per Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹30,000
Yes
9 Nov 2023
8 Sept 2023
11 Oct 2023
8 Sept 2023
5 Oct 2023
18 Sept 2023
Amount
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site all as specified and directed.
M&L for rendering 15mm thick in two layer (10mm & 5 mm) fair faces of brick work or Concrete surface in two coats 10mm thick in CM(1:6) as under coat 5mm thick CM (1:4) as finishing coat in two separate layer mixed with liquid water proofing compound in finishing coat only with liquid waterproofing compound @ 200ml per bag of cement finished even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound shall be measured and paid seperately
M&L for repairing of R.C.C projections, chajjias, roofs, facia, columns, beams etc., in patches not exceeding 3 Sqm in each patch by necessary preparation, Scrapping, cutting, chiseling Dusting and cleaning exposed reinforcement, surfaces of damaged, loose R.C.C surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregates and reinforced with welded mesh (If Reqd) with or without facia and finished with 15 mm thick cement and sand mortar (1:4) using coarse sand and thickness of R.C.C member n. exc 75mm including necessary form work at any height including dismantling of damaged concrete complete all as specified and directed by Engr-in-charge. (Note : welded mesh will be measured and paid separately.)
S&F Galvanised welded steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed as extra reinforcements to RCC members like ceilings, chajja’s, beams, columns, parapet walls, waste slab etc., including all cutting and waste (wt not exc 4.00 kg/Sqm) complete all as specified and directed.
M&L for preparing new surfaces of walls and applying two coat of cement base paint over a coat of primer as per manufacturer instructions including use of scaffoldings complete all as specified and directed.
Material & Labour for cleaning of roof surfaces and applying a coat of oil base bituminous primer @ 0.30 lit per sqm including laying of APP based polymeric membrane weighing not less than 3.00 kg/ Sqm and minimum 3mm thick reinforced with polyester non-woven fabric (wt, not less than 150gms/sq. m) laid on primed surface by tension application with 100mm overlap travers and 150mm overlap longitudinal including taking down old treatment complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 mixed with in liquid water proofing compound on fair faces of brick wall or concrete surfaces , finished even and fair complete all as specified. Note : WPC will be measured and paid separately.
Demolition cement concrete (unreinforced) Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work
Material & Labour for providing cement concrete 30mm thick PCC 1:2:4 type B-0 (12.5mm graded agg) as in padding on roofs slab to receive water proofing treatment, laid to required slope, finished even and smooth without using extra cement complete all as specified and directed.
Material and labour Plain cement concrete (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregate as in copings, bed plates, benching and the like finished fair & even, including necessary form work complete all as specified and directed.
Supply only liquid water proofing chemical.
M&L for applying two coats of aluminium paint @ 0.2kg/sqm on each coat ,Surfaces of any description , exceeding 10cm in width or girth, as per manufacturer's instruction complete all as specified and directed.
Taking down GI tubing 15mm bore all as specified and directed by Engineer-in-Charge.
Taking down GI tubing 20mm bore all as specified and directed by Engineer-in-Charge.
Supply and fix GI tubing 15mm bore medium grade with all fittings fixed to wall and ceiling complete all as specified and directed.
Fixing only 15mm bore tubes, any grade, to walls and ceilings or laying in floors
Supply and fix GI tubing 20mm bore medium grade with all fittings fixed to wall and ceiling complete all as specified and directed.
Fixing only 20mm bore tubes, any grade, to walls and ceilings or laying in floors
Disconnecting existing water storage tank of capacity exc 250 ltr but n.exc 500 ltr of any description setting aside for repair of WPT work and refixing and reconnecting to its original position after completion of water proofing treatment complete all as specified and directed.
Disconnecting existing water storage tank of capacity exc 500 ltr but n.exc 1000 ltr of any description setting aside for repair of WPT work and refixing and reconnecting to its original position after completion of water proofing treatment complete all as specified and directed.
Dismantling water tanks of capacity exc 250 ltrs but n.exc 500ltrs complete all as specified and directed.
Dismantling water tanks of capacity exc 500 ltrs and not exc 1000 ltrs complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top),of capacity 500 ltrs double layered, ISI marked hoisted and fixed in position all as specified in SSR Part I
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top),of capacity 1000 ltrs double layered, ISI marked hoisted and fixed in position all as specified in SSR Part I
S&F in repairs PVC water tank cover, suitable for 500 ltrs tank, fixed with and including hinge complete all as specified and directed.
Supply & Fixing in repair vitreous China squatting pan, ' Orissa patteren, size 580 x 440 mm white, with integral footrests (excluding flushing cisteren and flush pipe) complete all as specified and directed.
S&F PVC(SWR) 110mm dia P or S trap including connecting to out let with solvent cement , including lean concrete 1:5:10 complete all as specified and directed.
M & L in repairs for PVC nahani trap, plain with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) with solvent cement of dia 75mm complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Material and labour 25 mm thick, PCC (1:2:4) type B-0 using 12.50 mm graded stone aggregates as in base course for floor tiles , complete all as specified and directed.
M&L for joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match set, over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete of item all as directed.
Material and labour for providing water proofing tratment of sunken portion of WC, bathroom etc. applying cement slurry mixed with Acrylic based polymer modified cementitious composite compounded coating of make as approval in Technical Instruction 5/2003 adding: (a) 15mm thick rendering CM (1:4) with Liquid water proofing compound 200 ml per 50kg bag of cement on floor and wall , finishing the surface even and smooth without using extra cement. The surface shall then be cured and allowed to dry. (b) First layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hrs. (c) Second layer of slurry of cement @ 0.242 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ .126 kg/sqm. This layer will be allowed to air cure for 4 hrs followed with water curing for 48 hrs including dismantling of existing tratment etc complete all as specified and directed. Note: water proofing compound shall be measured and paid separatelly , contractor's quoted rate shall deem to include all other items mentioned above .
Dismantling of Asbestos cement (corrugated or semi corrugated) sheets as in roof covering complete all as specified and as directed.
Fixing only 6mm thick asbestos cement corrugated or semi corrugated sheets in roofs, walls etc fixed with `L' type or `J' type or cranked hook bolts complete all as specified and as directed.
M&L 6mm thick asbestos cement,corrugated or semi-corrugated sheet in roof,walls etc fixed with `L' type or `J' type or cranked hook bolts complete all as specified and as directed Make: Charminar / Everest
M&L for 6mm thick asbestos cement two piece, adjustable serrated ridge for corrugated sheets in roofs, walls etc fixed with `L' type or `J' type or cranked hook bolts complete all as specified and as directed Make: Charminar / Everest
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of an colour having tensile strength 550 Mpa as in roof covering /cladding to wall /chajja, fixed with self tapping screw as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) , fixed with self tapping screws /J or L hooks as specified
S&F 0.56mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed)
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Vee kay construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .