| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.3 L+₹37,308 (1.50%)Rejected-AOC | L2 | Rejected-AOC L1 being accepted |
| Sl No | Description | Qty | Unit | sri manikandan enterprises L1 | SRI LAKSHMI GANESH ENGINEERING WORKS L2 |
|---|---|---|---|---|---|
| 1.00SCHEDULE 'A' | |||||
| 2.00 | Checking of Split/ Window AC of capacity 1.5/ 2.0 TR any type for smooth functioning as per manufacturer specification at INS Kattabomman and RS(P) all as specified and directed and including replacement of minor components as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:-
(i) Cleaning of coil unit with dust blower,lubricate the indoor & outdoor fan motor with oil.
(ii) Checking and cleaning the drain connection and air filter periodically, washing of coil with solution once in a contract period.
(iii) Checking the refrigerant pipe insulation. (iv) Check & repair the minor electrical fault in incoming supply. (v) Checking and cleaning drain pipe for water leakage from indoor unit.
(vi) Required spares/components to be replaced under this contract shall be measured and paid seperately.
(vii) Checking the fault of cooling/ heating appliances. | 185 | Each Job | 1,800 ₹3,33,000 Lowest | 1,850 ₹3,42,250 |
| 3.00Supply and fixing of the following spare parts for1.5/2.0 Ton capacity window/split type AC including testing and commissioning etc complete all as specified and directed. | |||||
| 3.01 | Starting Capacitor 80/100 MFD. | 25 | Each | 370 ₹9,250 Lowest | 390 ₹9,750 |
| 3.02 | Running Capacitor but 36 MFD. | 30 | Each | 90 ₹2,700 | 87 ₹2,610 Lowest |
| 3.03 | Relay Assembly. | 10 | Each | 355 ₹3,550 Lowest | 367 ₹3,670 |
| 3.04 | Over load protector (O L P). | 20 | Each | 530 ₹10,600 Lowest | 555 ₹11,100 |
| 3.05 | Thermostat. | 15 | Each | 457 ₹6,855 Lowest | 457 ₹6,855 Lowest |
| 3.06 | Air filters (VOLTAS/ AIRCON/ VIDEOCON / SIDWAL). | 50 | set of Two | 458 ₹22,900 Lowest | 600 ₹30,000 |
| 3.07 | Condenser fan blade metal or plastic. | 15 | Each | 1,210 ₹18,150 | 1,200 ₹18,000 Lowest |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
26 May 2026, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services Fort St GeorgeRajajiSalai Chennai600 009
81476 REPAIR/ MAINTENANCE OF SUMMER COOLING APPLIANCES(ACs, REFRIGERATORS, DEEP FRIDGE and WATER COLLERS) AT INS KATTABOMMAN and RS (P) UNDER GE TIRUNELVELI
2026_MES_763731_1
CWE/NAVY/TVL/81476/E8 OF 2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
Tirunelveli
As per NIT
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹61,000
Yes
17 Jul 2026
6 May 2026
28 May 2026
6 May 2026
26 May 2026
20 May 2026
6 May 2026 - 13 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SCHEDULE 'A' | |||||
| 2 | Checking of Split/ Window AC of capacity 1.5/ 2.0 TR any type for smooth functioning as per manufacturer specification at INS Kattabomman and RS(P) all as specified and directed and including replacement of minor components as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:-
(i) Cleaning of coil unit with dust blower,lubricate the indoor & outdoor fan motor with oil.
(ii) Checking and cleaning the drain connection and air filter periodically, washing of coil with solution once in a contract period.
(iii) Checking the refrigerant pipe insulation. (iv) Check & repair the minor electrical fault in incoming supply. (v) Checking and cleaning drain pipe for water leakage from indoor unit.
(vi) Required spares/components to be replaced under this contract shall be measured and paid seperately.
(vii) Checking the fault of cooling/ heating appliances. | 185 | Each Job | - | - |
| 3Supply and fixing of the following spare parts for1.5/2.0 Ton capacity window/split type AC including testing and commissioning etc complete all as specified and directed. | |||||
| 3.01 | Starting Capacitor 80/100 MFD. | 25 | Each | - | - |
| 3.02 | Running Capacitor but 36 MFD. | 30 | Each | - | - |
| 3.03 | Relay Assembly. | 10 | Each | - | - |
| 3.04 | Over load protector (O L P). | 20 | Each | - | - |
| 3.05 | Thermostat. | 15 | Each | - | - |
| 3.06 | Air filters (VOLTAS/ AIRCON/ VIDEOCON / SIDWAL). | 50 | set of Two | - | - |
| 3.07 | Condenser fan blade metal or plastic. | 15 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
BOQ_855463.xls
BOQ • 0.40 MB
81476GENERALPAGES.pdf
Tender Documents • 0.31 MB
81476PS.pdf
Additional Documents • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .