₹40,000
Closing Date
12 Nov 2026, 6:55 pm3d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE Chennai
GARRISON ENGINEER FORT SAINT GEORGE CHENNAI - 600009
REPAIRS TO INTERNAL EXTERNAL PLASTERING, CHAJJAS, SEEPAGE TREATMENT TO EXTERNAL WALLS ETC, ROOF TREATMENT AND CONNECTED WORKS IN ZONE B AND E UNDER GE CHENNAI
2026_MES_795169_1
8114
Open Tender
Civil Works
Item Rate
180 days
GE Chennai
As per tender documents
7 documents required · 7 mandatory
₹500
GE Chennai
₹40,000
Yes
22 Oct 2026
22 Oct 2026
14 Nov 2026
22 Oct 2026
12 Nov 2026
5 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & Laying of CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors including pipe fittings and including taking up or down in the existing pipe line complete all as specified and as directed for pipe of 32mm outer dia. | 50 | RM | - | - |
| 2 | M & L in repair Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25 mm dia bore pipes complete all as specified and as directed. | 4 | Each | - | - |
| 3 | S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 1000 ltrs including dismantling of existing tank of any description and S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed. | 6 | Each | - | - |
| 4 | S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 500 ltrs including dismantling of existing tank of any description and S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed. | 6 | Each | - | - |
| 5 | M & L for Cutting holes into or through brick walls built in cement mortar and making good in PCC (1:2:4) type B-1 as required Superficial area not exc 150 Sq CM complete all as specified and as directed. | 50 | Per CM depth of cutting | - | - |
| 6 | Cutting holes into or through brick walls area exc 150 sqcm but n.exc 400 sqcm built in lime mortar and stone walls and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and as directed. | 50 | Per CM depth of cutting | - | - |
| 7 | S & F PVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints fixed to walls /floor as in spouts etc complete including dismantling existing pipes complete all as specified and as directed. | 70 | Rm | - | - |
| 8 | M&L for Preparation of Existing surfaces of walls/chajjas/facia etc to remove all dirt, mildew and other contaminants. Treat areas affected by Algae, moss or fungal growth with biocide wash solution and pressure cleaning equipment with a minimum capability of 100-140 bar water pressure. All grease, oils and asphalt materials must be removed completely. All surface cracks up to 5 mm width should be filled up with Dr. Fixit Crack-X or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP.Cracks more than 5 mm and all separation gaps should be filled up with Dr. Fixit Pidicrete URP modified mortar or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP. Priming using Dr. Fixit Prime seal or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP diluted in 2:1 ratio with water (2 parts Prime seal diluted with 1 part water) @ 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs. Apply one coat of Dr. Fixit Raincoat Waterproof Coating or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP without dilution by brush or roller for walls at the thickness of 120 – 130 microns all as specified and directed .
Note: All above treatment will be measured as one unit of square metre and paid accordingly. | 835 | Sqm | - | - |
| 9 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. | 1 | Cum | - | - |
| 10 | M&L for fly ash old size brick work straight or curved on plan exc 6M mean radius built in CM 1:6 complete all as specified and as directed. | 1 | Cum | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
Tender8114.pdf
Tender Documents • 0.94 MB
BOQ_891821.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .