| Sl No | Description | Qty | Unit | M/s Navansh Engineers & Consultants L1 | Sameer Auto Engineers L2 | sanjay traders L8 | Vinayak Trading House L7 | M/s Pratik Enterprise L4 | SAHYOG ELECTRIC L3 | Manu Enterprises L6 | Vending Services And Solutions L5 | ENVIRO TECH SERVICES L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil concrete all as specified and directed. | 392 | Cum | 140 ₹54,880 | 120 ₹47,040 | 80 ₹31,360 | 111 ₹43,512 | 55 ₹21,560 Lowest | 80 ₹31,360 | 105 ₹41,160 | 148 ₹58,016 | 100 ₹39,200 |
| 2.00 | All as per item No 1.00 above but for each additional 1.5 m or part thereof in depth beyond the first 1.50m | 1.4 | Cum | 175 ₹245 | 100 ₹140 | 80 ₹112 | 150 ₹210 | 1,200 ₹1,680 | 200 ₹280 | 120 ₹168 | 158 ₹221.2 | 10 ₹14 Lowest |
| 3.00 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each concrete all as specified and directed. | 180 | Cum | 20 ₹3,600 | 35 ₹6,300 | 60 ₹10,800 | 30 ₹5,400 | 100 ₹18,000 | 30 ₹5,400 | 30 ₹5,400 | 54 ₹9,720 | 10 ₹1,800 Lowest |
| 4.00 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point concrete all as specified and directed. | 300 | Cum | 20 ₹6,000 | 35 ₹10,500 | 70 ₹21,000 | 30 ₹9,000 | 111 ₹33,300 | 30 ₹9,000 | 30 ₹9,000 | 95 ₹28,500 | 10 ₹3,000 Lowest |
| 5.00 | M&L for Sand cushioning with fine dry unwashed sand in trenches for protection of cables concrete all as specified and directed.
Note: Punned thickness shall be measured and paid. | 112.2 | Cum | 550 ₹61,710 | 580 ₹65,076 | 850 ₹95,370 | 660 ₹74,052 | 450 ₹50,490 Lowest | 1,000 ₹1,12,200 | 600 ₹67,320 | 910 ₹1,02,102 | 850 ₹95,370 |
| 6.00 | Supply and laying flyash brick modular size, laid in trenches as cable covers concrete all as specified and directed. | 11 | 1000 Nos | 5,000 ₹55,000 Lowest | 5,000 ₹55,000 Lowest | 5,250 ₹57,750 | 5,000 ₹55,000 Lowest | 10,000 ₹1,10,000 | 6,000 ₹66,000 | 5,000 ₹55,000 Lowest | 8,100 ₹89,100 | 5,500 ₹60,500 |
| 7.00 | S&F in repairs Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall concrete all as specified and directed. | 90 | RM | 250 ₹22,500 | 280 ₹25,200 | 300 ₹27,000 | 270 ₹24,300 | 120 ₹10,800 Lowest | 275 ₹24,750 | 320 ₹28,800 | 350 ₹31,500 | 350 ₹31,500 |
| 8.00 | S&F in repairs Steel tubes, galvanised, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall concrete all as specified and directed. | 12 | RM | 350 ₹4,200 | 380 ₹4,560 | 420 ₹5,040 | 480 ₹5,760 | 185 ₹2,220 Lowest | 450 ₹5,400 | 600 ₹7,200 | 575 ₹6,900 | 550 ₹6,600 |
| 9.00 | S&F in replacement Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP 66 flood light(Area light) of 30 Watt, suitable for highlighting architectural façade and general purpose lighting incl all necessary fixing arrangments complete all as specified and directed. | 12 | Each | 1,423 ₹17,076 | 2,000 ₹24,000 | 2,200 ₹26,400 | 1,450 ₹17,400 | 1,300 ₹15,600 Lowest | 1,400 ₹16,800 | 1,800 ₹21,600 | 1,510 ₹18,120 | 6,500 ₹78,000 |
| 10.00 | S&F in replacement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. | 52 | Each | 4,400 ₹2,28,800 | 4,500 ₹2,34,000 | 7,800 ₹4,05,600 | 4,600 ₹2,39,200 | 4,500 ₹2,34,000 | 5,000 ₹2,60,000 | 4,900 ₹2,54,800 | 4,280 ₹2,22,560 Lowest | 10,500 ₹5,46,000 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
12 Jul 2025, 6:00 pmClosed
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School Mhow (MP) - 453441
REPAIR MAINT OF PERIMETER SECURITY LIGHTS AND PERIPHERY STREET LIGHTS WITH CONNECTED ITEMS AT VARIOUS LOCATIONS OF INF SCHOOL AND REPAIR MAINT OF STREET LIGHT FLOOD LIGHT HIGH MAST LIGHT GATE LIGHT AT DUNN MARG HPP GOLF VIEW INF MESS MUSEUM STN HQ
2025_MES_714685_1
8797/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
180 days
GARRISON ENGINEER (MIS)
All as per Tender document
8 documents required · 8 mandatory
₹500
GE (MIS) Mhow
₹88,000
Yes
8 Sept 2025
14 Jun 2025
14 Jul 2025
14 Jun 2025
12 Jul 2025
28 Jun 2025
Amount
Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil concrete all as specified and directed.
All as per item No 1.00 above but for each additional 1.5 m or part thereof in depth beyond the first 1.50m
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each concrete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point concrete all as specified and directed.
M&L for Sand cushioning with fine dry unwashed sand in trenches for protection of cables concrete all as specified and directed. Note: Punned thickness shall be measured and paid.
Supply and laying flyash brick modular size, laid in trenches as cable covers concrete all as specified and directed.
S&F in repairs Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall concrete all as specified and directed.
S&F in repairs Steel tubes, galvanised, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall concrete all as specified and directed.
S&F in replacement Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP 66 flood light(Area light) of 30 Watt, suitable for highlighting architectural façade and general purpose lighting incl all necessary fixing arrangments complete all as specified and directed.
S&F in replacement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F in replacement LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in replacement LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F in replacement LED bollard with opal diffuser and aluminum reflector capacity 09 watt including fixing all required fixing arrangments including PCC work of suitable size complete all as specified and directed.
S&F in replacement moulding compound Street light junction box of size 250 mm x 200 mm x 105mm complete with shock and rust proof, termite resistant, tamper proof , front openable type and including suitable provision for single phase, two wire cable (size upto 25 Sqmm 2 Core) incomming & outgoing loop -in loop connection and including one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete all as specified and directed. Make - Sintex Cat part No GSJB 2520 /Hensel/ABB.
S&F in replacement moulding compound street light junction box of size 250 mm x 250 mm x 160mm complete with shock and rust proof, termite resistant, tamper proof , front openable type and including suitable provision for three phase, four wire cable (size upto 25 Sqmm 4 Core) incomming & outgoing loop -in loop connection and including one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete all as specified and directed. Make - Sintex Cat part No GSJB 2525 /Hensel/ABB.
Repair/Renewal/maintenance of junction box/control box of street light by disconnecting all connection and reconnect the same after dusting, proper insulation by LT tape, replaecmrnt of Lugs, nut, bolt ,wisher if required , Replacement of MCB 06 Amp if required and ensure the junction box must be closed all as specified and directed by Engr-in-charge.
Repair/Renewal/maintenance of street light feeder over head conductors after arranging elect shut down of street light feeders from sub station to remove oxidise part at the point of connection to street light from LT over head line ane reconnect the same to LT over heal line after removing the oxidise part all as specified and directed by Engr-in-charge . Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safty devices.
Checking of street light feeder over head conductors /under ground cables using elect tools, equipments and safty devices after arranging elect shut down of street light feeders from sub station to remove elect faults like tightning of loose jumpers, trimming of tree branches on a particular span, re-tightning of binding wires on insulators, re-tightning of cable lugs etc all as required at site and as directed. Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safty devices. (ii) Materials used for rectification of faults like ACSR conductor, insulator of any type, cables etc and excavation & earth work will be measured and paid seperately.
Repair/maintenance of street/security lights any type, flood lights , post top lanterns or any other external lights in its position fixed pole/building structure or by taking down to ground, if required testing all the components/parts, wiring etc, identifying and replacing the defective components like chke (ballast), electronic driver (in case of LED Lights), ignitor, capacitor, lamp, lamp holder, connector, connection wires/ cable, MCB etc including refixing the fitting to its original position (if taken down), including repair/maint of street light control timer & junction box all as directed by Engr-in-charge for the complete contract period from the date of commencement of work.
Note:- (i) The rate against above mentioned item is deemed for cost of labour and allied expenses only. (ii) Cost of spares, choke (ballast), electronic driver, Ignitor, capacitor, lamp, lamp holder, connector, connection wire, MCB, timer spares etc) replaced against above mentioned item will be measured & paid for sepasrately under respective items of Sch 'A' here -in- below. (iii) The contractors representative will report to concerned JE E/M at 0900 hrs daily to collect the list of defective street lights at varrious area of Inf. School Mhow and will submit the completion report on the same day before 1730hrs to JE E/M. (iv) The contractor has to rectify the defects/ repair and make the street light functional within 24 hours form the time the list of deefective street lights is handed over to him/his rep by the concerned JE E/M. In case the street light is not made funtional for any reason within the specified time limit, an amount of Rs. 150/- per defective street light per day will be recovered from the amount due to contractor through RAR/Final Bill. (v) Contractor shall provide requisite and sufficient Nos. of transport and vehicle with fuel mounted hydraulic ladder at his own cost. (vi) The contracor shall maintain proper record of repair/maint in Register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-Charge for inspection at every monday or as and when askded for.
(vii) The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipment and tools. department shall not be repsonsible for any kind of safety incident/injury to the emplyoed manpower. (viii) The contractor shall maintain sufficient stock of spares/material required for repair/maint of street lights with the concerned JE E/M against the supply only items here-in-below, required screws, insulating tapes, submain wire, gaskets and other minor items including the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged and supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contrator under this item.
All as per item No 20.00 but for light fittings High Mast Poles of 11.00 to 13.00 m height.
Taking down high mast fitting from high mast structure through motorised system of 16/20mtr high and cheking all fittings including cleaning & lubricating of steel rope and repair the light fittings to make functional by replacing Flood light. Note:- Light and connecting cable will be measured and paid for seperately under respective itemsof sch 'A'.
Supply only (in replacement) of the following items, to be incorporated against item No 18.00 to 20.00 here in before:-
LED driver for FLOOD LIGHT of capacity 150 watts rating 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge. Make:- Philips/ Bajaj/ Havells
LED driver for FLOOD LIGHT of capacity 120 watts rating 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge. Make:- Philips/ Bajaj/ Havells
LED driver for FLOOD LIGHT of capacity 80/100 watts rating 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge. Make:- Philips/ Bajaj/ Havellss
LED driver for Street Lights,of capacity 60/70 watts rating 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge. Make:- Philips/ Bajaj/ Havells
LED driver for Street Lights,of capacity 30/36/45 watts rating 240 Volt, 50 Hz complete all as specified and as directed by Engr-in-Charge. Make:- Philips/ Bajaj/ Havells
S&F in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm complete all as specified and as directed
Supply only in replacement single core pvc insulated and sheathed cable with multistranded aluminium condutor of size 2.5 sqmm x two core and drawing in to existing GI pipe bracket and connect to street light fittings complete all as specified and directed by Engr-In- Charge .
S&F in replacement street light bracket made out of 40mm dia medium grade GI pipe of 1.2m length bent to required shape suitable for fixing street light / security light fitting on Steel tubular pole / RCC pole / building wall including two Nos clamps made out 30mm X 5mm flat with suitable nuts and bolts (clamp type - as per site requirement ) including two coats of aluminium paint over a coating of red oxide primer complete all as specified and directed by Engr-In- Charge .
Re-stretching tightening and fixing in position, the existing OH ACSR conductor LT line 3 phase with neutral and earth wire 440 V, 5/6 wire by loosing and taking down existing binding wire from the insulator of any size of ACSR conductor and bring it to required sag including provn of new binding wire and teghtening of cross arm on each pole and required trimming of tree branches. Note :- Unit rate are quoted by the contractor shall be deemed to be included for cutting and trimming branches of the trees coming in contact with ACSR conductor and separators as directed by Engr-in-charge.
Trimming/pruning of tree branches touching to the LT over head line or near to the LT over head line as per direction of AGE E/M /JE in charge complete including removing the tree branches from site complete all as specified and directed. NOTE - (a) Shut down shall be taken from Incharge JE / AGE E/M before taking the trimming work in hand by contractor (b) span from one pole to next pole (30 to 50 m) will be considered as a job. (c) T & P such as lader , rope, cutter , axes and other related material will be provided by the contractor.
M&L for Painting to street light pole of steel tubular swaged/ swan neck type with two coat of aluminium paint after cleaning to rusted portion of pole and finishing the surfaces including one coat primer top to bottom, painting on cross arms/FI clamps/street liht brackets of any type including making alternative blak and yellow strip with synthethic enemelled paint up to 1.5 Mtr height from ground level & writing of pole numbers with black paint on poles complete all as specified and directed.
M&L for painting of LT PCC poles 9.00m with acrylic paint after apply two coat of cement base primer and making the surface smooth including painting of cross arms, clamps, etc with two coat of aluminium paint and providing alternative strip of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 m height, writing of pole numbers in yellow circle 15 cm with black paint on poles complete all as specified and directed.
S&F in replacement XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with crimping of suitable size aluminium lugs complete of size 10 Sqmm nominal cross section x 2 core and testing complete all as specified & directed. Note : Earth work shall be measured and paid seperately.
All as above item No 29.00 above but 10 Sqmm nominal cross section x 4 core.
All as above item No 29.00 above but 16 Sqmm nominal cross section x 4 core.
All as above item No 29.00 above but 35 Sqmm nominal cross section x 3.5 core.
S&F in replacement MCB TPN, 415V, 40 Amps, 'B' series complete all as specified & directed.
S&F in replacement MCB TPN, 415V, 63 amps, 'B' series complete all as specified & directed.
S&F in replacement MCB SPN, 240V, 40 amps, 'B' series complete all as specified & directed.
S&F in replacement MCCB 125 Amps, 16 KA, FP, 415 volts with neutral link including al cable lugs complete all as specified & directed.
All as per item No 35.00 above but of capacity 100 amps, 16 KA.
All as per item No 35.00 above but of capacity 200 amps, 26 KA.
Supply, installation testing and commissioning (in replacement) of street light control box as a pole mountable enclosure conforms to IP-64 suitable for 440/230V, AC, 50 Hz, consisting of a light sensitive control system, power contactor for load switching, MCB and terminal suitable for Single- phase, 5 KW load blocks complete all as specified and directed by Engr-in-Charge. Make: Swadeep Nature Swith model No 02EC5kW1P /CG/L&T/Phillips
Supply, installation testing and commissioning (in replacement) of street light control box as a pole mountable enclosure conforms to IP-64 suitable for 440/230V, AC, 50 Hz, consisting of a light sensitive control system, power contactor for load switching, MCB and terminal suitable for Three- phase, 5 KW load blocks complete all as specified and directed by Engr-in-Charge. Make: Swadeep Nature Swith model No 02EC5kW3P /CG/L&T/Phillips
S&F in replacement Single phase contactor 5kW of load capacity 40 Amps, Incoming-Outgoing MCB rating 32-40 Amps & Circuit wiring minimum 10 Sqmm complete all as specified and as directed by Engr-in-Charge. Make:- ABB/L&T/Schneider
S&F in replacement Three phase contactor 5kW of load capacity 20-25 Amps, Incoming-Outgoing MCB (03 Nos each) rating 20-25 Amps complete all as specified and as directed by Engr-in-Charge .
S&F in replacement Nature switch sensor illuminate level for switching on is < 30 lux and for switching off > 10 lux alongwith part night operation facility of 4-12 Hrs. Make- Swadeep /CG/L&T/Phillips
Supply only in replacement MCB SP 6 to 32 Amps 230 Volt complete all as specified and as direcetd by Engr-in-Charge.
S&F in replacement Digital Timer switch for 1x 24 Hrs for controlling street light timimng with 150 hrs back up fixed in repairs. Make:- ABB/L&T/Schneider
S&F in replacement PVC tubes, medium grade, ISI marked 20mm bore for laying of sub-main wire/cable on Street Light Poles and on wall, incl necessary accessories & fixing arrangments like PVC band, clamps , nut -bolts etc. complete all as specified and as directed.
S&F in replacement Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP 66 flood light(Area light) of 120 Watt, suitable for highlighting architectural façade and general purpose lighting including all necessary fixing arrangments complete all as specified and as directed.
S&F in replacement LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
S&F in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F in replacement post top lantern LED type 25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
S&F in replacement LED bollard with opal diffuser and aluminum reflector capacity 08 watt including fixing all required fixing arrangments including PCC work of suitable size complete all as specified and as directed.
S&F in replacement Two core PVC insulated copper cable with multistranded copper condutor of size 1.0 sqmm x two core, and drawing in to PVC Conduits & GI pipe bracket and connect to street light fittings complete all as specified and as directed.
M&L for Cement concrete 1:2:4 type B 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for Cement concrete 1:4:8 type D 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for Cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coupling of size 300x300 mm or chamfered on edges complete all as specified and as directed.
Dismantaling of old cracked /unserviceable PCC poles /MS pole struts any type and size and deposited at a suitable locations complete all as specified and as directed by Engr-In- Charge.
S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 ,9.00 metres long, erected to truely vertical position, painting externaly embedded portion in PCC with black bitumenous paint and externally exposed to view portion with aluminium paint in two coats, making five alternate strips 30cm wide with black and yellow paint in two coats, marking MES number with black paint complete all as specified and as directed. Note : Excavation and PCC will be measured and paid separately.
Disconnecting conductor,insulator,chanel,street light bracket etc from LT pole of height 9 to 11 meter and shifting LT Pole by lifting the LT pole, load the same in a suitable vehicle to transport to the site and unloading the same and re-fixing after repairs the same against of old cracked /unserviceable PCC poles /MS pole struts any type and size including deposited at a suitable locations as directed including required PCC Works complete all as specified and as directed by Engr in Charge. Note:- (a)The distance of LT Pole shifting, not more than 3 KM within cantt area. (b) The cost of PCC Works for fixing of LT Poles are included in the rate quoted .
Sameer Auto Engineers (BID ID -3348085)
SAHYOG ELECTRIC (BID ID -3348084)
M/s Pratik Enterprise (BID ID -3354542)
Vending Services And Solutions (BID ID -3356551)
Manu Enterprises (BID ID -3356239)
Vinayak Trading House (BID ID -3356182)
sanjay traders (BID ID -3348184)
ENVIRO TECH SERVICES (BID ID -3348143)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .