Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 4TH STAGE NO 931 9TH MAIN JAIN HOSTEL ROAD T K LAYOUT MYSORE MYSORE KARNATAKA 570009 | MYSURU | KARNATAKA | 570009 | Admitted-Finance |
Tender Value
₹3.2 L
EMD Value
₹6,365
Closing Date
11 Jun 2020, 4:00 pmClosed
EE(E), ED1, BSNL. BGL
OFFICE OF THE EXECUTIVE ENGINEER(E), BSNL, ELECTRICAL DIVISION-1, 4TH FLOOR, TELEPHONE HOUSE, RAJBAWAN ROAD, BENGALURU 560001
Extending UPS AND Raw power supply to GSAT-20 Antenna and associated works At M/w TE Building Chinthamani, Kolar SSA. SH-
2020_BSNL_49472_1
02//EEE/ED1/BSNL/BGL/2020-2021
Open Tender
Electrical Works
Item Rate
30 days
GSAT20 AT M/W TE BUILDING, CHINTHAMANI
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (Cash), HQ, BSNL, BGTD
₹6,365
17 Jun 2020
2 Jun 2020
12 Jun 2020
2 Jun 2020
11 Jun 2020
2 Jun 2020
2 Jun 2020 - 10 Jun 2020
Amount
Extending UPS & Raw power supply to GSAT-20
Supplying & Fixing of weather proof box made of SMC / Polyvinyl with ingress protection rating of IP 66 for outdoor installation & size of approximate dimension 200mm x 150mm x 100mm with 1 No 6A DP MCB & Connector i/c fixing, locking hinges, knockouts for cable entry, interconnections etc as reqd. [Make: Hensel enycase / Sintex or equivalent make & model make]
Supplying & fixing 30 - 35 Watt , LED type Outdoor Flood Light fixture with IP 66 protection and minimum 60° beam angle, drivers, accessories and suitable for mounting on existing masonry / CC pedastal / MS angle iron stand in ground, above flood level, duly wired ready to use, suitable for 230 Volts. 50 Hz. AC supply including inter connection , testing commissioning etc., complete as reqd.,(Make: Crompton LFLN11-35-CDL/60,Jaquar/Philips/Wipro or equivalent make & model) (For Antenna Pod lighting)
Supplying of following size PVC insulated, PVC sheathed/XLPE, Copper / Aluminium Conductor Armoured, UG cable of 1.1KV grade etc., as required. [ISI Mark] A)4 Core 10 Sqmm Copper UG Cable (2 runs for UPS Supply to Antena)
Supplying of following size PVC insulated, PVC sheathed/XLPE, Copper / Aluminium Conductor Armoured, UG cable of 1.1KV grade etc., as required. [ISI Mark] B) 4 Core 70 Sqmm Aluminium Cond. UG Cable (2 Runs for Raw power supply to Antena )
Supplying of following size PVC insulated, PVC sheathed/XLPE, Copper / Aluminium Conductor Armoured, UG cable of 1.1KV grade etc., as required. [ISI Mark] C) 2 Core 6 Sqmm copper Cond. U G Cable (For Pod Light)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizeRCC/ HUME/ METAL pipe as required [ Upto 35 sq. mm] A) Upto 35 sq. mm- 80 Mtrs
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizeRCC/ HUME/ METAL pipe as required [ Upto 35 sq. mm] B) Above 35 sq. mm and upto 95 sq. mm
Supplying of following size PVC insl., PVC sheathed/XLPE, Copper/ Aluminium Cond. Armoured, UG cable of 1.1KV grade on wall surface/On Existing Cable Tray(clamped with saddle. & with 25x3mm MS Flat clamp above 35sqmm upto 95sqmm )etc., as required. [ISI Mark] A) 4 Core 10 Sqmm Copper UG Cable (2 runs UPS Supply to Antena)
Supplying of following size PVC insl., PVC sheathed/XLPE, Copper/ Aluminium Cond. Armoured, UG cable of 1.1KV grade on wall surface/On Existing Cable Tray(clamped with saddle. & with 25x3mm MS Flat clamp above 35sqmm upto 95sqmm )etc., as required. [ISI Mark] B) 4 Core 70 Sqmm Aluminium Cond UG Cable (2 Runs for Raw power supply to Antena Motor)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. A) Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. B) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. A) 4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. B) 4 X 70 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. C) 2 X 6 sq. mm (19mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. (A) 63 mm dia (OD-63 mm & ID-51 mm nominal)
S/F of 16 Amps DPMCB in the existing panel with Suitable size channel for mounting MCB and Neutral link with suitable accessories etc as required
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. .(For Body Earth-2 Nos, + 2 Nos For Surge Arrestors)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
SITC of extension switch panel made up of 16G CRCA sheet, complying to latest IE rules suitable for extendable type, & fixed to the existing LT Panel, Panel shall be powder coated with approved colour & shade panel shall have clear sign writing with fluorescent paint including s/f following switches & accessories, interconnection with suitable bus bar links for incoming & outgoing & suitable size removable type gland plate at the bottom of sheet for outgoing cable, including earthing the switches with 2nos copper strip of size 20mmx5mm, providing tinned earth bus bar in the bottom, lifting hooks, providing C channel in bottom of size 100mm x 50mm x 5mm etc. as reqd. Details of switch gears & other accessories to be provided are listed below.(a) 100A, 4pole MCCB with thermal magnetic Release with 36KA Breaking Capacity, relay range of 50 to 63Amps with extended operating Handle-2Nos (Make: L&T DN0-100D, CM 97919OOH2OG/Schindler/ Siemens or any equivalent approved make and model) (b) ACC Spreader terminals DN100C/DN0 - 2 sets ((c) 4x35Sqmm PVC insulated, unarmoured Cu conductor interconnecting cable-2 Sets
Supplying and Fixing of Powder coated, Outdoor Feeder Pillar made of 14G CRCA MS Sheet for outside cabinet of size approx. (1300mmx1250mmx350mm depth) & 16G MS sheet for detachable type MV panel of size (1100mmx1050mmx300mm depth) i/c cutting, bending, painting with suitable colour over red oxide primer, suitable for accommodating following electrical items, interconnection with suitable size insulated copper conductor wire, Providing cable alleys, cable entry knock outs, etc, as reqd. (M/s L&T or SS make) (a) DH125 4pole MCCB, 35KA Breaking Capacity of Range 80-100 Amps with operating handle & Separators at one end - 2 No( b)DH125 4pole MCCB, 35KA Breaking Capacity of Range 50-63 Amps with operating handle - 1 No (c) 150A 4strip Al Busbar with insulated supports - 1 Set (d) MCB DB Arrangement with 32 A TPN MCB - 1 No & 6 A SP MCB - 6 No for Antenna area lighting (Make: Hager or SS, 'C' Series, 10KA Breaking Capacity) (e) Lightning & Surge arrester Type I + II protection devices suitable for B+C /3+NPE, 3 phase and nuetral MV supply, to operate on 3Ph, 415V 4 wire AC supply with TT system surge protection devices shall comply with IEC 61643-1 for protection against lightning & Switching Surges and alongwith necessary fault indicatons [ Green flag for Healthy & Red for Fault] withr Din rail mounting (Make: OBO Betterman Model : V25 B+C/3+NPE 320V , Siemens, Dehn, Phonenix or equivalent make and model)-1set (f)Crono Digital time switch suitable for 240 V, 50 HZ ,AC supply, WITH CONTACT RATING OF 16A (For 'NO') & 5A (For 'NC') @ 240 VAC, Precise time programming for Daily/Weekly / Pulse switching, 25 ON/OFF programs BASE / DIN Mounting, with programmable facility for on & off in a day/month/year mode & ( Timer Make-GIC / L&T 67DDTO or similar superior make)
Providing and fixing 50mmx50mmx5mm MS angle iron supports for Feeder pillar Panel i/c cutting, welding, painting etc., as reqd.
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form and plastering , curing etc as required. work etc as required.
St Joseph Electricals
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .