Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.8 LAccepted-AOC | ₹5.8 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹5.8 LRejected-Finance | ₹5.8 L | L-2 | Rejected-Finance L-2 |
Tender Value
₹5.8 L
EMD Value
₹12,000
Closing Date
30 Jan 2026, 12:00 pmClosed
Executive engineer
E.E.RED OFFICE VIKAS BHAWAN MAINPURI
Const. of Room in Shri Mulayam Singh Yadav Inter Collage in vill. Sauj, Mainpuri.
2026_REDUP_1108825_8
2193/EE/RED/14-01-2026
Open Tender
Civil Works - Buildings
120 days
mainpuri
Please refer Tender documents.
2 documents required · 2 mandatory
₹677
₹12,000
Yes
12 Feb 2026
24 Jan 2026
30 Jan 2026
24 Jan 2026
30 Jan 2026
24 Jan 2026
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1.
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). 4.1.8
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick DSR 5.9.20
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts. DSR 4.3.3
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. DSR 5.9.21
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). DSR5.3
Mild steel or Iron work in plain work such as reinforced concrete or rinforced brick work ( when not included in and an over all rates) brought to required shape as necessary including bending for proper completion of the work and including the suplly of steel and its wastage Bend. hooks and authorized over lapping shell be muasured upto floor to level. DSR 5.22.1
12 mm. cement plaster in 1:4 (cement and coarse sand)single coat onfair side of single or half brick wall for interior plastring upto floor to level including internal rounded angles chamfers and/ or rounded angles not exceeding 80mm in grith and finished even and smooth. No Extra mixing any additive. DSR 13.4.1
15 mm. cement plaster in 1:4 (cement and coarse sand)single coat onfair side of single or half brick wall for interior plastring upto floor to level including internal rounded angles chamfers and/ or rounded angles not exceeding 80mm in grith and finished even and smooth. No Extra mixing any additive. DSR 13.5.1
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. DSR 10.31.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces DSR 10.5.1
Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm). 13.44.1
Distempering with 1st quality acralic Distemper having VOC contant less than 50gm./ltr. two or more coat over and including prime coat with cement primer. DSR 13.41.1
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate. DSR 11.3.1.
S/F Marble stone Patiya etc. all complete.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
BOQ_2047521.xls
BOQ • 0.25 MB
sbdd.pdf
Tender Documents • 1.61 MB
Download all tender documents and submit your bid