LT COL RAVI KUMAR PATIYAL, GE
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR/ MAINTENANCE OF CENTRAL AIR COOLING SYSTEM AT COMMAND BUILDING AT VAYUSENA NAGAR, NAGPUR
2026_MES_750254_2
8802/E8
Open Tender
Civil Works
Item Rate
240 days
GE AF NAGPUR
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹20,000
11 Apr 2026
7 Mar 2026
9 Apr 2026
7 Mar 2026
2 Apr 2026
14 Mar 2026
Material and labourfor preparation of old painted surface of bottom tank of AIR washer chamber size approx 4.5mtr X 1.5mtr X 0.3Mtr by removing all dirt, dust, grease, oil etc and painting complete with two coats of water proof paint of approved colour over a coat of red-oxide primer on entire inside surface of tank complete all as specified and directed . Note:(1) At the time of painting process Cost of opening & refixing of filter pad ,angle or tank nut, bolt ,washers etc included in quoted rate.
Material and labourfor for Taking down electric motor 30/25 HP 415 volt coupled to blower unit after disconnecting the electrical connection, and earth connections removing from its foundation and transportation to work shop , checking the serviceability of bearing both side of motor , greasing of bearing up to free rotation of shaft of motor greasing on reassemblying the motor complete, reinstallation on foundation, reconnecting back the cable and earth connections and , varnsihing, drying, opening, overhauling , greasing ,Alignment pump/motor poperly authorised mechnical including repair to foundation if required at site etc complete in all respect and starting the pump all as directed. Note:(1) Contractor shall be responsible for maintaining required RPM after repair ,non compliance of speed considered as incomplete repair. (2) Cost of Rewinnding & Bearings shall be measured and paid separately.
Taking down electric motor 0.5 upto 1 HP 415 volt coupled to pump after disconnecting the electrical connection, and earth connections removing from its foundation and transportation to work shop , checking the serviceability of bearing both side of motor , greasing of bearing up to free rotation of shaft of motor complete, greasing on reassemblying the motor to reinstallation on foundation, reconnecting back the cable and earth connections and , varnsihing, drying, ovening, overhauling , greasing ,Alignment pump/motor poperly authorised mechnical including priming of PVC foot valve etc complete in all respect and starting the pump all as directed. Note :(1) Cost of rewinding , Bearings shall be measured and paid separately under relevent item. (2)Contractor shall be responsible for maintaining required including Priming work for motor for taking out water cellouse pads after repair ,non compliance of speed considered as incomplete repair
Supply only spare parts for Motr/pump set of capacity 30/25 HP in repair of vide sr item No.1 as follows:- a) Supply only shaft of AHU Motor any make any size as per exiting motor at site of capacty 25/35HP complete.
b) Supply only check nut including gasket
c) Supply only bearing exiting site requirement fitted in motor complete
Material and labourfor preparation of old painted surface of pump installation by removing all dirt, dust, grease, oil etc and painting complete with two coats of synthetic enamel paint for spray painting including writing MES No of approved colour over a coat of red-oxide primer on air blower motor /blower stand / and floor of ambient chamber , water pump icluding motor of capacity upto 35 HP Including 0.5 HP water pump complete all as specified and directed .
M&L for Dismantling of existing defective/unsv motor of following capacity HP, three phase/Single phase , 415 V, 50 Hz, from the foundation, disconnecting the electric connection, coupling pulley, transportation to work shop, seperating the stator and rotor assembly ,cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding of stator with super enamelled solid copper conductor (winding wire) of appropriate gauge and size to match with the existing winding motor so as to acheive desired RPM , including varnishing, drying, ovening, overhauling, greasing, provising insualtion and reassembling stator and rotor , connecting coils/ winding in star and delta mode at the junction box/terminal , fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed. (a) 0.5 up to 1 HP
Taking down u/s and Supply and fix industrial Exhaust fan axial flow motor with blade and frame heavy duty industrial exhaust fan (36 inch/ with IP 55 specification, rigid frame with rubber mounting for silent operation epoxy powder coated and better resistance to corrosion and scid alkali fumes , totally enclosed highly efficient heavy duty copper motor including testing of motor with suitable copper wire winding ,incl refixing of exhaust fan motor with blade and frame, AC, volts, Heavy duty and blades 36 inch sweep, suitable for air washer plant complete all as specified and directed.
Taking down U/S & Supply & fixing V belt cat part MN 30 for capacity of 30000 to 40000 cfm blower motor suitable for the existing plant size 32/20 complete all as specified and directed. Make: Mitsuboshi/ Dunlop/ Poly-F
Supply & install Blower pully as per existing blower capacity fitted in site for air washer ambiator chamber including taking down old u/s pulley complete all as specified and directed. Note: Sample availabe as AGE E/M office.
Taking down U/S old nitrile insulation / glass insulation & supply and fix new Nitrile insulation 25 mm thick nitrile rubber sheet with suitable adhasive as per (manufacturer's instruction) of duct work fixed out side of duct/ inside duct and air washer chamber for weather proofing using 25 mm thick nitrile rubber sheet fixing with complete all as specified and all as directed by Engr-In--Chargre 1. Note No-01 The cost of Nitrile insulation patch occured during contract period maintnence shall be deemed to be included in this item rate. Note No-02 The cost shall be included fixing of Aluminium sheet strip given in schedule item No 13 all as specified and as directed by engr-in-charge Make : K-flex/Armacel/Suprem
Suply and fix aluminium strip 25x3 mm thick by proving suitable support to fixing of nitrile insulation inisde/outside of AHU and duct for air washer plant Note: The cost shall be deemed to be included making holes in strip , nut bolts and washers etc all as specified and as directed,
Taking down U/S and S&F short neck of duct connected with air diffuser with long type and complete fixing with air sealed diffuser for avoiding of noise and air leakge . Note : If found leakge or noise in the duct or plant the contractor has responsible to repair without any extra cost.
Taking down U/S & supply and fix high performance plated panel or air pre-filters for central cooling system and general ventilation used as pre filtration made of GI /Aluminium construction having efficiency 90% down to 20 micron suitable for existing plant size of filter 60cmx60cm, having features low initial pressure drop, disposable,washable , maintenance free, compact design (sample available at AGE E/M office) Make : Alpha Kel India/ AAF Camfil/ Freudenberg
Taking down U/S & supply and fix high performance plated panel or air pre-filters for central cooling system and general ventilation used as pre filtration made of GI /Aluminium construction having efficiency 90% down to 20 micron suitable for existing plant size of filter 30cmx30cm, having features low initial pressure drop, disposable,washable , maintenance free, compact design (sample available as AGE E/M office)
M&L for cleanig of rusted portion of duct and dust settled in existing duct & dampers in whole building where is passing of duct and Air all floors going from main duct to connected branch duct number unit duct and diffusers and open of AHU cleaning the portion & refixing the same plant by using suitable equipment or suction machine/compressor from AHU to neck duct complete all as Engr-in-Charge Note: Rusted portion of duct should painted in red oxide included quoted rate
M&L for Comprhensive mainnence /overhauling /repair of complete air washer ambiator chamber including necessary oiling/greasing , cleaning and realignment motor properly by technican of any motor aliignment with blower of existing plant of capacity 10000 to 40000 CFM Grease gun shall be used for greasing whenever necessary purpose all as directed Make of Greasing : Castrol/Lithium Grease/ServoMP3 Note :(1) The quoted rates shall deemed to be included cost for the materias for Oil/Greasing including labour.
Taking down U/S & supply and fix aluminium grills for air supply made out of powder coated extruded aluminium grils adjustable type with variable angle and verticle and horizantal louvers and gape between louvers should be 25 mm with volume controls dampers complete all as directed Make:Aircon Airiqpment/Mapro/Air flow Note : The quoted rates shall deemed to be included cost for damage of aluminium grill fitted in site including cutting of wall and POP work.
Taking down U/S Cellulose or celldek pads and supply and fix new consists for cellulose wood fibres in paper form . having high quality standard and posses on efficiency of more than 85% as per site all as directed. (sample available at AGE E/M office) Make Hutek/Munters/DRI Note : Contractor should noted only damage portion change.
Supply only grease suitable for pump bearings
Taking out U/S & supply and fix ball Bearing for Blower shaft fitted in site for air washer ambiator chamber complete All as specified directed by Engr-in-charge., (sample available at AGE E/M office) NOTE -:1) The quoted rates shall deemed to be included cost for opening of blower drum & shaft including all types of nut,bolt,washer,packing etc and after replacing the bearing fixing the same inside the air washer ambiator chamber complete.
Takin down U/S & Supply & install Motor pully as per existing Motor capacity fitted in site for air washer ambiator chamber complete All as specified directed.(Sample availabe at AGE E/M office)
Taking down u/s exhust fan heavy duty of size 36 " removing old unsv copper winding , rewinding the same with existing gauage copper wire winding complete including testing after rewinding and repainting with existing colour and refixing in original position complete all as specified and directed.
Taking down u/s and Supply and fix MCB 4 pole 63 amps, breaking capacity 10 KA, confirming to IEC60947-2, 415 volts, 50 Hz including making necessary incoming and out going electrical connection with suitable size of copper lugs etc. complete all as specified and directed. Make : Legrand Cat No. 408702or equivalrnt in hager/ Siemens
Taking out unservicable & S & F MCCB 4 pole 200 amp , breaking capacity 36 Ka, 415 volts, 50 Hz confirming to IEC60947-2 including necessary incoming and out going electric connection with suitable size of copper lugs etc. Make : Legrand Cat No 408702 / Siemens/schneider,Ckt Breaker Easy pact cvss250 f ,Thermal magnetic TM- d trip unit 4p 3d complete all as specified and directed.
Taking down U/S Air cooler ambient chamber tray (Tray size sample availble at site) and M & L for Air cooler ambient chamber tray by using 2 mm thick GI Sheet including necessary cutting ,welding fabricating etc for complete tray/portion of tray etc required for fabrication and tightining of door handle and damage any door handle to replaced the same complete all as specified directed Note No -01 The cost shall be included suitbale arrangemnt of welding machine , electric arrangemnet / gas cyclinder . Note No-02 The cost shall also included dismantling of pre air fileter, water pump , water piping and cellulose pads from water cooler tray and refixing of the same after rectification of leakage and completely leak proof arrangementof tray as specified and as directed. If the any air filter / celluose pads damaged during execution , The contractor will rectify the same free of cost.
Taking out u/s and supply and fix PVC insulated 1100 volt grade heavy duty cable multistranded copper conductor and connectinf upt o the e;ectrical system of size 4 sqmm 3 core complete all as specified and directed.
Taking out u/s and supply and fix PVC insulated 1100 volt grade heavy duty cable multistranded copper conductor and connectinf upt o the e;ectrical system of size 2.5 sqmm 3 core complete all as specified and directed.
Taking out unserviceable control burnt wiring including unserviceable spares from control panel of central air cooling duct and M & L Repair relaying and new Electrical interlocking wiring of LT panel of Air cooling System control wiring with FRLS copper wire of existing size of including all connected lux, cable, fuzes, complete all as specified and directed. NOTES :- (i) The cost of minor spares required including connector, lux, wire/cable, fuses required is deemed to be included in the quoted rate. (ii) Spares incorporated during repair of the electric panel will be measured separately under relevant item.
Supply only RYB indicator Make : Schneider/L&T/Siemens
Supply only voltmeter CTs 0-500 Volt Digital type Make : Schneider/L&T/Siemens
Supply only Amp meter CTs 0-300 Amps Make : Schneider/L&T/Siemens
Supply only over laod relay range 0.2-15 A Make: Make : Schneider/L&T/Siemens
Supply only Auxillary contactor 2 NO-2 NC Make : Schneider/L&T/Siemens
Supply only on delay timer 0.2 to 60 second Make : Schneider/L&T/Siemens
Supply only push button start/ stop Make : Schneider/L&T/Siemens
Supply only red indication Make : Schneider/L&T/Siemens
Supply only yellow indication LED neon bulb Make : Schneider/L&T/Siemens
Supply only green indication LED neon bulb Make : Schneider/L&T/Siemens
Taking down u/s and supply and fix 4 sqmm copper wire for internal wiring single core FRLS Make : Finolex/Polycab/Havells
Taking down u/s and supply and fix suitable size copper lugs/thimble fitted in motor Make : Schneider/L&T/Siemens
Supply only Add on 2 NO - 02 NC M MCX 9-80/MO 9-110 Make : Schneider/L&T/Siemens
Supply only spreader link kit Make : Schneider/L&T/Siemens
Supply, Installation, Testing & Commissioning of Galvanized-Class VIII with zinc coating of 120 gm / Sqmt surface area as per IS-277. With TDF/TDC Flange system with factory fabricated Box section with neoprene rubber gaskets of thickness to match the dimensions of the ducts shall be used for connecting two ducts. (The Minimum Duct Gauge should be of 20 Gauge only.) Duct construction and installation shall be in accordance with Standards and all ducts testing pressure should be 500 Pascal. (pa) The Duct shall be supported with GI steel Rods & MS angle Supports at regular intervals. Ducts should be factory fabricated & Transportation should be in box section only to site. in site the duct needs to be stored in proper manner & covered with polythene sheets to avoid dust accumulation. The guages sutable as per size of 18/20 guages.
Taking out unserviceable & S &F MCCB 4 pole 100 amp, breaking capacity 16 Ka, 415 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. :Make- Schneider, L&T/ Siemens
Supply only Power contactor 3 pole 415V AC type 32A MNX 50, Make : L&T Cat No. ST19001 or equivalent in Siemens, C&S.Schneider, L&T/ Siemens
Supply only Power contactor 3 pole 415V AC type 16A MNX 50, Make : L&T Cat No. ST19001 or equivalent in Siemens, C&S.Schneider, L&T/ Siemens
Supply only electronic type ET 100 with time range 0 to 60 second, 360 Volt -Make : L&T Cat No 3 Each Q1748 or equivalent in Siemens, C&S. Schneider , L&T/ Siemens
Taking out u/s and supply and fix PVC insulated 1100 volt grade heavy duty cable multistranded copper conductor and connecting panel to exhust fan to the electrical system of size 4 sqmm 3 core complete all as specified Make- Pplicab, Hevels, Fenolex
Taking down U/s and supply and fix Push Button Remote Kit Make- Schneider ,L&T/ Siemens
Taking down U/S & dismenteling of canvash Airwaisher to Duct supply and fix high performance Double layered Feixible canvash Duct to Airwaisher Make- Resistoflex, donlop Aircon,Airequipment
Disconnecting, dismantling and removing central shaft of air handling units of central Air cooling system of any capacity and any make for repair, transporting to the work shop, opening up for repairs carry out the repairs, of shaft including re-metalling, turning, brazing and polishing work of AHU shaft of any size, cleaning, greasing and overhauling incld replacement of unserviceable/worn out ball bearing and other minor spares, reassembling after repairs, bringing back to its location fixing in original position, connecting instt, and testing on full load capacity and commissioning to the entire satisfaction of Engr in charge. Note : Unit rate quoted by tenderers shall deem to incl for nuts, bolts, washers , lugs, thimbles, wires and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Deptt.
Charges for attending break down of Centrai Air cooling system of capacity 1000CFM to 40000CFM by technical person or team fault finding including attending repairs as and when required such as No start condition of Air cooling system and repairing, starting the Air cooling system till smooth running and setting up the alignment/required parameters of all major parts such as fan belt, Motor ,exhaust fan power contactor, starter, MCCBs, control panel, pumps etc as required in ground/as ordered by EIC complete all as specified and as directed.
Supply, Installation and Testing of multi -blade type key operated louver dampers of galvanised steel sheet for collars to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system as per the approved shop drawings and specifications.
Supply & fix in repair ultra violet UV barrel of size approx 12 inch in length (as exting at air washer) including addn/alteration of necessary cutting ,welding & connection of pipe complete all as directed by Eng-In-charge.
Taking down U/S & supply and fabrication of MS angle frame for installation/hanging of GI duct of different sizes , made out of MS angle iron/flat iron with threading,cuuting bending including nut,bolt and washers etc of any size and making hole making hole for fixing of anchor bolts at RCC slab complete all as specified and directed
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m all as specified and directed
stage.html
html • 0.02 MB
technical_846316.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.15 MB
CRIEDIT8802.pdf
Tender Documents • 0.08 MB
BOQ_846316.xls
BOQ • 0.47 MB
TENDERDOCS8802.pdf
Tender Documents • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .