| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.8 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable | |
| 2 | 2₹40.5 L+₹4.6 L (12.9%)Rejected-Finance | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | 3₹43.8 L+₹7.8 L (21.8%)Rejected-Finance | 3 | Rejected-Finance Not being the lowest bidder | |
| 4 | 4₹45.5 L+₹9.5 L (26.5%)Rejected-Finance | 4 | Rejected-Finance Not being the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
29 Jan 2021, 6:00 pmClosed
GE I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
CERTAIN B/R REPAIRS TO PATH CULVERTS, COMPOUND WALL SECURITY FENCING AND HARDSTANDING IN TECHNICAL AREA ZONE -1 AND II UNDER GE I RND RCI HYDERABAD
2020_MES_398862_2
8587
Open Tender
Civil Works
Item Rate
300 days
GE I R AND D RCI
MES enlisted Class D category a i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D RCI, HYDERABAD
₹84,000
Yes
4 Mar 2021
1 Jan 2021
2 Feb 2021
1 Jan 2021
29 Jan 2021
10 Jan 2021
Amount
Demolition of brickwork or stone masonry including all quoins, arches, pillars, etc., built in cement mortar and removing the debris off the premises complete all as directed.
Dismantling fencing wire mesh/chain link fencing, any type complete all as directed.
Dismantling of wrought iron or mild steel works of any description not otherwise provided for complete all as directed.
Dismantling posts or struts (wood, steel or RCC) any section embedded in concrete masonry, including taking out embedded portion and making good disturbed ground including disposing of debris complete all as directed
M&L, walling of squared rubble masonry, regular coursed secunderabad type, well bonded, bedded and solidly hearted built in cement mortar 1:6, struck flush in the same mortar as work proceeds complete all as specified and as directed.
All as per item No 5 above but except stone. Note: Serviceable stones obtained from item No 1 shall be reused under this item.
M&L, brickwork with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L, 15mm thick rendering in cement mortar 1:6, on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L, Flush pointing to new squared rubble stone masonry, coursed or uncoursed built in CM 1:4 complete all as specified and directed
M&L, PCC 1:2:4, type B-0 using 12.5mm graded stone aggregate as in coping and the like including necessary formwork, weathering, slightly rounded or chamfered angles and throating and other similar works complete all as specified and directed.
S&F, mild steel framed work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., including all necessary drilling, bolting or riveting etc., and similar works conforming to Fe 290 Gde-E-165 complete all as specified.
M&L, preparation of new steel surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
S&F in repairs, Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixed to any type of standard rails straining bolts including securing or tying at crossings with galvanized mild steel wire, staples or steel pins etc., complete all as specified and directed. Note: Each line wire shall be measured.
S&F, Mild steel screw bolts (machine made) 5 to 10mm diameter of neck with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5CM but not exceeding 10CM long complete all as specified and directed.
M&L, High tension wire concertina razor coil of 600mm dia with medium size blade at 35mm spacing, blade width 20mm, 7 spirals per running metre, spread at 150mm centre to centre including fixing to mild steel angle with clips all as per manufacturers instructions complete all as specified and directed.
M&L, broken glass coping on top of walls embedded in and including 25mm thick cement mortar 1:3, complete all as specified and directed. Note: 63mm gauge broken glass at the rate of 10Kg per square metre of rendered surface shall be firmly embedded before the mortar has set in, jogged edges of the glass shall be left projecting.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation and getting out in any type of soil complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L, PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M&L, PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in foundations for angle iron fencing posts, plinth beams etc., and mass concrete complete all as specified and directed.
M&L, RCC Nominal mix 1:2:4 type B-1 using 20mm graded stone aggregate as in columns, posts and struts etc., complete all as specified and directed.
M&L, RCC Nominal mix 1:2:4 type B-1 using 20mm graded stone aggregate as in foundations, footings, foundation beams and plinth beams etc., complete all as specified and directed.
Use and removal of steel formwork to sides of concrete foundation, footings, bases of column, raft and raft beams, sides and soffits of foundation (if any) and plinth beams for rough finished surfaces of concrete, flat, complete all as specified and as directed.
Use and removal of steel formwork to sides of columns, pillars, posts, struts etc., square, rectangular or polygonal for fair finished surfaces of concrete, complete all as specified and as directed.
M&L, TMT bars 10mm dia and over, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L, TMT bars 8mm dia and over, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
S&F, mild steel round bars 8mm dia, for securing chain link fencing including two coats of painting with synthetic enamel paint over a coat of primer complete all as specified and as directed.
S&F, mild steel galvanized chain link fencing of approved mesh size and nominal dia GI wire with tolerance as per IS to any type of standards, rails, straining bolts, etc., including provision of line wires, binding wire complete all as specified and as directed. Note: The chain link fence fabric shall have zinc coating of type heavy as given in IS 4826 or in IS 12753. Tolerances permitted on the diameter of mesh and line wire shall be as given in IS: 280.
Demolition and breaking up drain pipes of any size (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as directed.
M&L, 300mm bore reinforced concrete pipes, class NP2 with collars laid to falls in trenches or concrete bed, jointed in cement mortar 1:1 including packing under and haunching against the sides of pipes using PCC 1:3:6 type C1 using 20mm graded stone aggregate as in concrete bed, testing complete all as specified and as directed
M&L, 450mm bore reinforced concrete pipes, class NP2 with collars laid to falls in trenches or concrete bed, jointed with cement mortar 1:1 including packing under and haunching against the sides of pipes using PCC 1:3:6 type C1 using 20mm graded stone aggregate as in concrete bed, testing complete all as specified and as directed
Taking down cement plaster of any description on brick or stone walls from any height including racking out joints, hacking for key, scrubbing down with water etc., including removal of rubbish material off the premises complete all as directed.
M&L, 15mm thick rendering in cement mortar 1:4, on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L, preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Demolition of PCC in ground floors and paving's not exceeding 15cm thickness (below or above ground level) complete including disposal of debris off the premises all as directed by Engineer in Charge.
M&L, 75mm thick PCC 1:4:8 type D-1 in sub base using 20mm graded stone aggregate finishing the surface even and rough including necessary formwork complete all as specified and directed
M&L, 50mm sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L, 60mm thick, M-35 Grade, machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658-2006 complete all as specified and directed
M&L, 100mm thick PCC 1:2:4 type B-1 in flooring using 20mm graded stone aggregate finishing the surface even and smooth without using extra cement including necessary formwork complete all as specified and directed.
M&L, 25mm thick chequered cement concrete tiles of 300mm x 300mm size with grey cement and pigments, set, jointed and pointed in neat cement slurry over and including 20mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L, PCC 1:3:6, type C-1 using 20mm graded stone aggregate as in drain, surface channels and benching including necessary formwork complete all as specified and directed.
Extra for forming fair finished drain or channel of 30cm inner girth in cement concrete, using extra cement including forms moulds mitred / stopped ends etc., complete all as specified and as directed.
Add or deduct for serial item No.43 above for each 25mm inner girth or part thereof over or under 30cm.
M&L, preparation of concrete/terrace floor tiles, cement tiles applied to walkways or driveways, paver blocks or any plain cement surface by scrubbing with wire brush to remove loose dirt, algae and fungus growth, washing with water and applying two coats of anti algal/fungal floor coat emulsion paint as per manufacturer's instructions complete all as specified and as directed.
M&L, precast cement concrete blocks 1:2:4 type B-1 using 20mm graded stone aggregate as in kerb stones of required size with plain fair faces, including chamfers etc., necessary formwork and set in cement mortar 1:6 complete all as specified and directed.
M&L, preparation of new concrete road side kerb surfaces of any description over 10cm girth or width, not otherwise described etc., and applying two coats of synthetic enamel paint in two colours as per approved pattern complete all as specified and directed.
S&F, 110mm bore PVC (SWR) pipes in any length fixed in walls as in weep holes complete all as specified and as directed.
Saiansh Associates
SHAH ENTERPRISES
M/s ANUSHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .