Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹52.7 L+₹3.2 L (6.49%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹54.6 L+₹5.1 L (10.2%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹57.0 L+₹7.5 L (15.1%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹63.2 L+₹13.6 L (27.6%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
3 Jan 2022, 6:00 pmClosed
GE I R AND EAST BANGALORE
GE I RD East Bangalore 93
REPAIR TO HT SWITCH GEARS INCLUDING PREVENTIVE MAINTENANCE CABLING LT PANELS AND OTHER CONNECTED EXTERNAL ELECTRIC WORKS AT CABS STIR AND CEMILAC UNDER GE I RD EAST BANGALORE
2021_MES_494215_1
8195
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND EAST BANGALORE
D b (ii)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND EAST BANGALORE
₹95,000
Yes
17 Mar 2022
13 Dec 2021
5 Jan 2022
13 Dec 2021
3 Jan 2022
29 Dec 2021
14 Dec 2021 - 24 Dec 2021
Amount
Excavation in trenches not exceeding 1.5Mtr wide and not exceeding 1.5M depth in foundation etc and getting out in soft/loose soil.
Returning and filling in including spreading , levelling, watering and well ramming in layers not exceeding 25cm thick with soils complete
Removing excavated soils not exceeding 50M and depositing where directed at a level not exceeding 1.5M above the starting point
Material and labour for sand cushioning to under ground cable providing with a layer 8cm thick before laying the cable and 15 cm thick after laying the cable complete all as specified and as directed Note: Punned thickness only will be measured for the purpose of payment
M & L for precast concrete cable cover class HVP type I with peak of size 300 x 180 x 40mm complete all as specified and as directed
S & lay GI pipe galvanised medium grade of the following size for protection of cable across road. make : JINDAL/ ZENITH/ TATA
Material and labour for XLPE LT cable insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laying in trenches/floor complete all as specified and directed as under.
240 SQ MM 3.5 Core
185 SQ MM 3.5 Core
150 SQ MM 3.5 Core
120 SQ MM 3.5 Core
95 SQ MM 3.5 Core
70 SQ MM 3.5 Core
50 SQ MM 3.5 Core
35 SQ MM 3.5 Core
25 SQ MM 3.5 Core
16 SQ MM 4.0 Core
10 SQ MM 4.0 Core
Material and labour for HT cable 95 Sqmm 3 core PVC insulated , screened, PVC bedded, galvanised steel strip or wire, armoured power cable (heavy duty) with aluminium conductor 11000 Volts grade cross sectional area complete laying on trenches all as specified and directed.
Material and labour for HT cable 120 Sqmm 3 core PVC insulated , screened, PVC bedded, galvanised steel strip or wire, armoured power cable (heavy duty) with aluminium conductor 11000 Volts grade cross sectional area complete laying on trenches all as specified and directed.
M & L for taking out bottom trolly of HT VCB 11 KV 400/800 Amps capacity after disconnecting power supply for carrying out servicing and maintenance of operating mechanism, latch assembly, spring mechanism. checking of electrical control wiring of OCB and checking for proper functioning of shunt trip coil, lubricating of all moving parts and checking/cleaning of alignment of moving contacts with fixed contact assembly for proper functioning of operation. Re- assembling of bottom trolly of HT OCB fixed in its original position and testing commissioning for smooth functioning complete all as specified and as directed.
Supply and fixing of moving contact assembly suitable for HT VCB/OCB 11 KV 400 amps VCB/OCB includes dismantling the old unserviceable moving contact assembly suitable for HT VCB/OCB complete all as specified and as directed. Make :- Crompton Greaves or equivalent
M & L for calibration IDMT relays set of three through relay test kit inlcuding other required measuring equipment to the site by secondary injection method and testing for proper functioning/tripping systems of relays complete all as specified and as directed. Note : The rate quoted by the contractor is deemed to be included for quarterly checking of relays in VCB/OBC for its proper setting/fuctioning and tripping of VCB/OCB during over load/earth fault.
Supply and fixing of HT current transformer of capacity 200 / 100 / 5-5 HT 11 KV including testing commissioning of through primary injection method with suitable testing kit and also checking the control panel wiring including setting the CT range with relays setting for proper functioning/tripping and taking out old unserviceable CT complete all as specified and as directed.
Supply and fixing HT digital display voltmeter suitbale for HT OCBs,HT VCBs at various substation suitable for HT panel 1100 / 100 volts (auxiliary volts) including necessary connections and taking out old unservicebale complete all as specified and as directed. Make : AE/MECO
Supply and fixing HT digital type ammeter suitable for CT ratio 50 / 100 / 200 amps including necessary connections and taking out unserviceable ammeter complete all as specified and as directed. Make : AE/MECO
M & L for filtration of transformer oil through stream line/high vaccum filtration plant for extracting moisture content in the oil and carbon deposits and bringing the di-electric strength not less than 40 KV for one minute with sphere gap of 2.5 mm including checking the value of acidity of oil with a acidity test kit and submitting test report for Die electric strength and acidity of transformer oil before/after filteration complete all as specified and as directed. Note : 1.The contractor should submit the Test sheet for all transformer in which dehydration of transformer oil carried out
Supply and filling of New transformer oil confirming to IS 335-1963 as amended and die electric strength not less than 60 KV for topping up/replacement of unserviceable transformer oil complete all as specified and as directed. Make : Electrol/Castrol
S & Fix VRLA 2 volt each battery 100 AH contains 55 Nos with complete battery stack with all fixing arrangement with electric connections incleding taking down all as directed and specified by Engr in charge.Make- Amaraj/Excide or eqpt
Material and labour for painting distribution transformer with two coats of synthetic enamel paint of smoke grey colour after neatly cleaning and preparing the surface for the transformer of the following capacity including writing SM / MES No (5 cm height) with white enamel paint complete all as specified and as directed.
(a) 800 KVA TO 1000 KVA
(b) 200 KVA TO 400 KVA
Supply, joint, test, end termination joint kit heat shrinkable indoor type, suitable for HT 11 KV XLPE cable 3 core 120 to185 sqmm with necessary jointing materials including connecting etc including taking down unserviceable end joint complete and laying on floor/trenches complete all as specified and as directed. Make : Densons/Birla M/M Seal or equivalent
Supply, joint, test, end termination joint kit heat shrinkable indoor type, suitable for HT 11 KV XLPE cable 3 core 95 sqmm with necessary jointing materials including connecting etc including taking down unserviceable end joint complete and laying on floor/trenches complete all as specified and as directed. Make : Densons/Birla M/M Seal or equivalent
Supply and fixing silica jel breather with new silica gel suitable for distribution transformer up to capacity 2000 KVA including taking out unserviceable complete all as specified and as directed.
Supply and fix inlet and outlet brass gate valve 32 mm/40mm heavy duty complete all as specified and as directed.
Material and labour for rewinding of HT/LT transformers by winding the defective coils with copper wire as IS of same gauge as per existing size together with new material and aluminium bracings beore placing into the transformer and assembling the HT/LT coil with new insulation between core and LT coil and fixing the coil in the chamber , testing and commissioning the transformer and recording the test result up to satisfactin levels of Engr-in -Charge complete all as specified and directed
Removing, transporting the indoor/outdoor type transformers of capacity 630KVA to 1000 KVA from one location /work shop tto cary out the necessary repairs/modification of HT/LT indoor/outdoor transforner . After dismantling HT/LT side carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strips and draining out the transformer oil to the required level and storing careully in cleaned containers, cleaning of terminals, inspection of core replacing the 5mm thick rubberise cork sheet gasket for tank top cover reassembling the complete dismantled items, reconnecting the HT/LT supply cable ends at the site complete all as directed
All as per item No. 25 here in before but of transformer of capacity 200 to 400 KVA
Supply and fix in repair MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA rupturing capacity in existing panel board including modification on existing panel including complete connection as required at site including taking down old unserviceable MCCB . Make : L & T / ABB / Schneider / Legrand
Supply and fix in repair MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KArupturing capacity in existing panel board including modification on existing panel including complete connection as required at site including taking down old unserviceable MCCB . Make : L & T / ABB / Schneider / Legrand
Supply and fix in repair MCCB 4 Pole, 415 V, Adjustable type,200 Amps with breaking capacity 36 KArupturing capacity in existing panel board including modification on existing panel including complete connection as required at site including taking down old unserviceable MCCB . Make : L & T / ABB / Schneider / Legrand
Supply and fix in repair MCCB 4 Pole, 415 V, Adjustable type,250 Amps with breaking capacity 36 KArupturing capacity in existing panel board including modification on existing panel including complete connection as required at site including taking down old unserviceable MCCB . Make : L & T / ABB / Schneider / Legrand
Supply and fix in repair MCCB 4 Pole, 415 V, Adjustable type,400 Amps with breaking capacity 36 KArupturing capacity in existing panel board including modification on existing panel including complete connection as required at site including taking down old unserviceable MCCB . Make : L & T / ABB / Schneider / Legrand
Supply and fix in repair MCCB 4 Pole, 415 V, Adjustable type,630 Amps, with breaking capacity 50 KA rupturing capacity in existing panel board including modification on existing panel including complete connection as required at site including taking down old unserviceable MCCB . Make : L & T / ABB / Schneider / Legrand
M & L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letter, figures and conventional skulls and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size 25cm x 20cm HT complete all as specified and as directed.
Supply and replace Gang operated Air Break switch tilting type combined with drop out fuse complete set of 400Amps including replacement of HT jumpers proper fixing with clamping on HT pole and all complete connections as directed by Engr in charge. make : PSI/RMCO
Supply only line discharging (earthing rod) assembly complete in 3/4 sections 20 feet long with Aluminium screw handed jaw contact, earth wire etc complete suitable for 11KV make : PSI/RMCO
S & F in repair push botton on/off suitable for 11KV panel of existing size including removing old unserviceable of colour Red, Green, Blue ,Yellow(as per site requirment).
S & F in repair indicator lamp assembly complete LED type suitable for 30V DC or 110V AC including fixing of HT OCB. Make : Minic control
S & F in repairs of Three pole VCB main shaft assembly suitable for HT 11 KV . make : Kirloskar,Type -C-500 or equivlent
S & F in repairs Vaccum Interputure suitable for vaccume circuit HT 11 KV . make :BEL Or equivalent
S & F Copper strip 32mm x 6 mm buried in ground including excavation /refill with 40 mm light grade pipe all as directed by Eng - in- Charge
S & F in repair shunt trip coil suitable for VCB/OCB of 600Amps capacity of 110 volt. make : Crompton Greaves
M & L for cable route indicator, cast iron circular disc engraved with cable size and grade 150 mm dia welded with 35x35x4 mm angle iron mast 0.5 mtr from the GL including PCC foundation 1:3:6 type CI of size 30x30x45 cm and necessary earth work all as directed.
Supply & Fix astronomatical time switch timelight 3 pole 40A/230V time switch , Make :- IndoAsian/Havells/leagrand
Supply & Fix Isolator TPN 100 Amps, 415 Volts Replacing unservicable Isolator complete all as directed by Engineer-in -charge. Make :- Havells ,L&T /legrand
S & replace straight through joint heat shrinkable suiable for 11KV 50 sqmm to 95Sqmm 3 core UG cable complete. make : Denson/M-Seal
S & replace straight through joint heat shrinkable suiable for 11KV 120 sqmm to 185 Sqmm 3 core UG cable complete. make : Denson/M-Seal
S&F in repair temperature gauge of suitable size and capacity of the transformer of any make. make: AE/Meco
M&L for HT bushing 11000Volts insulator for transformer of following capacity
200 KVA to 400 KVA
800 KVA to 1000 KVA
M&L for LT bushing insulator 1100 Volts for transformer of following capacity
200 KVA to 400KVA
800 KVA to 1000 KVA
M & L for taking out the defects parts from HT VCB while servicing and then supply and replace the following new spare suitable for HT 11KV VCB indoor type make : CG/Kirloskar of capcity 400Amps 3 phase 50Hz all as directed by Engineer-in-Charge.
Tripping coil
Male & female contact
Locking assembly
Charging spring
NO Volt coil 110V DC
PT fuses (11KV/8Amps HT 5 x UTF 11) with stem
M & L for IDMT relay for VCB/OCB MC61A opearating voltage 230 volts AC/DC with the over current and earth fault element complete testing and commissioning all as specified and directed by Engr in charge. Make-L&T microprocesser relay.
Trip push botton assembly complete
Catch lever guide
Sleeves for spout bushing
Switch bushing epoxy
Drum switch assembly
M & L for Earth continuity conductor of GI or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 32 x 6 mm complete all as specified and as directed.
Supply and fix in replacement of old unserviceable PT with new potential transformer for incomer panel oil cooled with protective enclosure of ratio 11KV/110V/RT3/110/RT3 Class 1.0/3P , burden 200VA voltage factor 1.2 continuos/ 1.5 for 30 seconds , ILV 12/28/75KVP , Ins class B Ref Std IS: 3156/1992 , one end earthed type with one No. HRC fuse on HV side . Note : Primary neutral to be solidly earthed including removing of old unserviceable PTs, Make: KALPA/E16
Supply only hand gloves HT for operating /handling sub station of 33 KV ISI marked complete all as specified and as directed. Make : Jaipuria Brothers or equivalent
M & L for removing carefully the existing stone aggregate from 11 KV yard for levelling the ground and laying the same after laying new 20 mm aggregate all as directed and specified by Engr in charge.
M&L for earthing complete with 60cm x 60cm x 6 mm thick GI plate electrode buried in ground vertically not less than 2.25mtrs deep below ground level with top edge of the plate not less than 1.5mtrs below ground level with GI strip of size 32 x 6mm as earthing lead including necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixed with fine sand in continuous layers, PCC (1:3:6 ) type C1 in chember ,Precast 50 mm thick in cement ( 1: 2:4) type B.1 with CI frame with cover, 20mm dia bore light grade GI watering pipe furnel etc fixing of GI Pipe 40 mm bore protection for earthing strip from earth pit to test point complete & making connection all as specified in Electrical plate No 3 and as directed by Engineer-in-Charge.
M & L for Earthing complete with chemical earthing with copper plate 900x600x 3.15 mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to copper earth strip of 32 x6 mm by means of bolts & nuts,to GI and connected to earthing test point all as shown in elecrical plate No-5 of SSR part -1 of 2009 * specified or indicated and testing on completion including excavation /earth work in any type of starta PCC (1:3:6) type C1 earthing chamder pre cast slab 50 mm thick in cement concrete (1 : 2 : 4 ) type B1 , Reinforced with welded steel wire fabric (XPM) weight not less than 4 KG /sqm cast iron frame ,funnel with wire mesh GI watering pipe of 20 mm bore medioum grade and lugs with and including GI strip 32X6 mm strip as earthing lead.7.5 meter long complete all as specified..
M & L for PCC (1:3:6) type C1 using 20 mm graded aggregate for making good the disturbed portion of road/floor/platform etc including form work compaction etc all as specfied and directed by Engineer-in-Charge including taking down.
M & L for well burned bricks , laid flat ( old size) sub class B designation 75 for cable protection copmplete all as specifed and directed.
Labour only to find HT cable fault of any rating through BESCOM by using High pot Test tool kit from BESCOM to locate the HT fault .If any jointing kit required then measured and paid separately. Note - No any additional cost to be provided to contractor for T & P.
Supply & Fix Isolator TPN 63 Amps, 415 Volts, , Replacing unservicable Isolator complete all as directed by Engineer-in -charge. Make :- Havells ,L&T /legrand
Supply and fixing of chain link fencing made out of plain mild steel wire galvanised 4mm dia fixed on angle iron support by welding of size 50x50x6mm for vertical/horizantal 25x25x4mm horizantal for chain link fencing all around the four pole structure incuding gate with locking arrangement including excavation, PCC work and painting with one coat of red oxide primer for complete fencing including all angle supports all as directed by Engr-in-Charge
Painting fencing post one coat anticrossive enamel paint, including foundation & earth work required for angle iron fencing post &.two coats of Aluminum paint over a coat of zinc chrome primer on Chain link surface both side all as directed by Engineer - in - Charge
S & F Copper strip 20mm x 3.15mm with saddles and fixing screws for roof conductor and down condition above ground.
Supply and fixing street light bracket made out of 40 mm bore GI pipe medium grade 1.20 Mtr long, bend to shape with 2 Nos clamp made out of 40 mm x 6 mm size MS flat with nuts, bolts, washers etc all as directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv (size 2x1m) for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete
M & L for servicing of 4 pole structure including replacemet of all jumpers with proper lugs/thimble, painting the structure and channels/cross arms , replacement of wornout nuts bolts, replacement of blown fuses , trimming of tree branches including painting to the structure with aluminium paint over a coat of red oxide primer complete all as specified and as directed Note: 1. Proper shut down should be taken in advance. 2. All Safety precautions should be taken by the tenderer
Labour & Painting of LT outdoor type feeder pillar box of size not more than 1.50 x 1.25 x 0.75m with two coats of enamelled paint over a coat of red oxide primer including repair to the hinges and locking system , cleaning inside the panel, cleaning the vegetation around the foundation upto 1.0 mtr around complete all as specified and as directed
Supply and fixing buliding lights bracket made out of 25 mm bore GI pipe medium grade 1.20 Mtr long, bend to shape with 2 Nos clamp made out of 25mm x 6 mm size MS flat with nuts, bolts, washers etc all as directed.
Material and labour for painting of existing steel tubular street light poles above the PCC foundation/coping surface, etc with a coat of synthetic enamel paint alumium Paint including numbering of poles, cleaning of existing surface with wire brush complete all as directed by Engineer-in -Charge.
Supply & Fix street light pole boxes of size 6x8x3.5 inches for MCB Sliding cover boxes,weather dust rain guarded cable entre and exit arrangement of suitable size of housing of with 01 No MCB SP 6/10 Amps Including Bolts & nuts Clamps for fixing to pole, painting a coat of synthetic enamel paint including termination of cable of size 16 to 35 sqmm 2 Way 4 connectors Each in each boxes all as directed by Engineer - in - charge ( Sintex, Hensel)
Repair / Maintenance of the street light fittings / High bay light fittings/Flood light fittings on pole or building / Workshop (any height) by replacing the spares as given below:- Note : (i) The measurement of payment shall be made as per actual replacement of accessories, no extra cost will be paid to the contractor for T&P and tradesmen as required. (ii) Taking down the fitting as required for maintenance for cleaning or minor repairs such as screw, wires including taking down etc. (III) The cost of the same is deemed to be included in the rate quoted. (iv) The contractor shall depute one electrician and two helper on all working days in MES complaint cell for attending the complaint regarding the street light.
Supply & fix led out door drivers of capacity 100W for street light fittings all as specified & directed Cat No X100CO70V143FNY1BO Make :-Crompton/philips/Havells
S & F in replacement of LED driver suitable for LED street light / flood light fittings(as requirment at site) of capacity upto 150 to 250 Watts of existing make complete as directed and specified by Engr in charge.
Supply and fix MCB 'C' Curve SP 6 to 32 Amps of breaking capacity 10 KA 220 Volt Replacing unservicable MCBs complete all as directed by Engineer-in -charge. Make :- Havells ,L&T /legrand
C R R CONSTRUCTIONS
HEERA CONSTRUCTION CO.
B5BUILDING SOLUTIONS
MAJ CONSTRUCTIONS
Sai Ram Builders
M/S Suresh Raju
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .