Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC | ₹3.5 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹3.9 Cr+₹35.6 L (10.2%)Rejected-AOC | ₹3.9 Cr+₹35.6 L (10.2%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹4.2 Cr+₹69.8 L (20.0%)Rejected-AOC AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | ₹4.2 Cr+₹69.8 L (20.0%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹4.3 Cr+₹79.0 L (22.6%)Rejected-AOC | ₹4.3 Cr+₹79.0 L (22.6%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹4.5 Cr+₹98.6 L (28.2%)Rejected-AOC | ₹4.5 Cr+₹98.6 L (28.2%) | L5 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹5.2 L
Closing Date
28 Nov 2020, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
CONSTRUCTION OF 16 NOS RESIDENTIAL ACCOMMODATION AND OFFICERS TRANSIT FACILITY (4 SUITES) AT AMRITSAR
2020_MES_328225_1
80990/E8
Open Tender
Civil Works
Lump-sum
365 days
Jalandhar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹2,000
Garrison Engineer Amritsar Cantt
₹5.2 L
Yes
22 Jan 2021
7 Sept 2020
30 Nov 2020
7 Sept 2020
28 Nov 2020
10 Nov 2020
7 Sept 2020 - 21 Nov 2020
Amount
Note: (i) Please refer Schedule 'A' Notes given on serial page No. 22 to 26 of tender documents. (ii) Item from Srl No. 3.00 to 11.01 of this document shall be Part-XII (Miscellaneous items) of BOQ.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 31(R).
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 32(R).
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 33(R).
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 35.
Lump sum price worked out by the contractor for ROAD, PATH & CULVERT WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 37.
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 38.
Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-VII brought forward from serial page No. 39.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 41®
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 42.
Lump sum price worked out by the contractor for SOLAR WATER HEATING SYSTEM WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 44.
Lump sum price worked out by the contractor for SUMMER APPLIANCES AND SPECIAL ITEM WORKS as listed in Schedule 'A' Part-XI brought forward from serial page No. 46.
INTERNAL ELECTRIFICATION WORKS
Material and labour for concealed point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLS PVC insulated multi-stranded copper conductor in and including heavy duty PVC conduit pipe of minimum size 20mm bore medium grade (ISI marked) including fittings & accessories including MS concealed terminal boxes with 3mm thick plastic laminated bakelite (Hylum) sheet top cover for mounting switch socket etc including 1.5 sqmm FRLS PVC copper conductor multi-stranded as earth wire connected to the common earth dolly as specified for one light point/fan point/bell point controlled by one switch complete all as specified and directed.
M&L for concealed point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLS PVC insulated multistranded copper conductor in and including heavy duty PVC conduit pipe of size minimum 20mm bore (ISI marked) including fittings & accessories with modular metal flush box and modular white cover plate with frame out for mounting modular switch socket etc including 1.5 sqmm FRLS PVC copper conductor multistranded as earth wire connected to the common earth dolly as specified for one light point/fan point/bell point controled by one switch complete all as specified.
All as per item No. 3.02 above but one three pin modular socket outlet 5 Amp on independent board.
All as per item No. 3.02 above but one 3/5 pin modular socket outlet 5 Amp on same board.
All as per item No. 3.02 above but one light point controlled by one two way modular switch.
All as per item No. 3.02 above but with 2.5 sqmm cable and 2.5 sqmm copper conductor as earth wire for 5 pin, 15 Amps socket outlet on independent board complete.
Supply and fixing energy efficient LED, enviornment friendly single tube light fittings surface/ pendent mounted compete with white powder coated slim box type batten of formed CRCA with snap on installer suitable for 1200 mm long 18/ 20W LED tube rod batten or LED tube light base complete with in built LED of 20 watt 6000K for white illumination including all accessories and connection from ceiling rose to connector complete all as specified.
Supply and fixing energy efficient aesthically designed 2x2 LED, IP-66 flat panel for ceiling mounting which provides soft lights and glare free symmetrical illumination environment friendly LED light for porch illumination as per national lighting code (SP 72:2010) by using security light of less than or equal to 34W (total input power) CCT-5000-5700K CRI>67,PF>0.95, operating performance temp-10 degree centigrade +45 degree centigrade LED module life span 50000 burning hours external surge and over voltage protection device upto 440V along with connection 3 core copper flexible cable of size 0.75 sqmm to be provided with weather proof connector complete.
Supply and fixing lamp holder insulated body with back plate for batten fittings including LED lamp 15 watt complete all as specified
Supply and fixing energy saving LED street light fitting 45 watt with PDC aluminium body and toughened glass visor fitted in frame. Secondary optical lens for superior light distribution efficiency >90 Lm/ W with CCT 5700K, IP-65 complete with 3 core 2.5 Sqmm PVC insulated aluminium cable including suitable size of GI pipe 40mm dia 1.5m long with 2 Nos MS clamp for fixing of GI pipe on wall complete all as specified and directed.
Supply and fixing LED 40 watt decorative post top lantern luminaire with IP-65 protection for 360 indirect resistant to impact and corrosion, glare free and batter uniformity complete all as specified and directed.
Supply and fixing ceiling fan 1200mm sweep BEE ISI marked including provision of cord flexible copper conductor 23/0.0076 three core from ceiling rose to connector and writing MES No with black synthetic enamel paint 2cm height complete all as specified.
Supply and fixing propeller type AC ventilating fans 300mm sweep PVC body (exhaust fan) with louver shutter complete including material and labour for providing/ cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 14/0.0060 copper cable rubber insulated from ceiling rose to exhaust fan motor and writing MES NO with black synthetic enamel paint 2.0cm height complete all as specified and directed
Supply and fixing MCB SP 6 to 32 Amp, 240V, 10 KA, B-Curve type complete all as specified and directed
Supply and fixing MCB DP 6 to 32 Amp, 240V, 10 KA, B-Curve type complete all as specified and directed
Supply and fixing sub main wiring with two single core FRLS PVC insulated stranded copper conductor 6 Sqmm and 1 x 6 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 6 sqmm & one run of earth wire 6 sqmm will be considered as one unit.
Supply and fixing sub main wiring with two single core FRLS PVC insulated stranded copper conductor 4 Sqmm and 1 x 4 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 4 sqmm & one run of earth wire 4 sqmm will be considered as one unit.
Supply and fixing Three phase electronic meter tamper proof with LED display of rating 10-40 Amp class 1.0,415 Volt, 50 Hz counter type display with transparent hinges including connection from SPN to meter with 6sqmm copper stranded conductor PVC insulated cable including earth wire complete all as specified
Supply and fixing Single phase electronic meter tamper proof with LED display of rating 5-30 Amp class 1.0,230 Volt, 50 Hz counter type display with transparent hinges including connection from SPN to meter with 6sqmm copper stranded conductor PVC insulated cable including earth wire complete all as specified
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth lead GI wire 4mm dia (8 SWG) connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 15mm bore and GI pipe 20mm bore light grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete (1:3:6) type C-2 & RCC cover in M-20 (Design mix) and all as shown in Electrical Plate No 3 of MES standard Schedule of Rates (Part-I) of 2009 complete all as specified and directed. Notes : (i) Outer edge of earth pit will be 1 m away from the outer edge of PCC chamber. (ii) GI earth wire and protection pipe upto main board is included in this item. (iii) Water pipe shall be provided in slanting position.
Supply and fixing decorative wall light fixture made up of polycarbonate suitable for 1 x 15W retrofit LED rings, and glass shade with lamp holders, connectors block, 1 x 15W LED blub, glass fitted engineering plastic B-22 lamp holder with electrical copper contacts, self screwed polycarbonate diffuser in open finish for soothing light effect, LED 15W etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed
Supply and fixing MCCB incomer distribution board double door vertical type made out of CRCA MS sheet surface with insulated material like polyester or with epoxy powder coating surface mounting TPN 4 way, 415 Volts with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB and IP-43 IK 09 protection with and including 100 Amp 16 KA 4 pole MCCB with thermal-magnetic setting and Icu=Ics=100% including suitable type MCB with blank plate complete all as specified and directed.
Supply and fixing sheet metal enclosures single phase double door flush to wall fitted with 200 Amp bus bar and neutral link for MCB (without MCB's) 8 ways SPN 240V complete all as specified and directed.
Supply and fixing sheet metal enclosures single phase double door flush to wall fitted with 200 Amp bus bar and neutral link for MCB (without MCB's) 4 ways SPN 240V complete all as specified and directed. Note for Ser No 3.22 to 3.24 :- DB should be suitable for IP-43 protection including provision for Reversible Door.
Supply, installation, testing and commissioning, powder coated, factory made, panel, indoor type, conforming to IP 52 protection, size 1.0 x 0.90 x 0.25m, made of robust steel sheet construction, minimum 3.15mm thick CRCA steel with counter sunk holes, at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket around doors with provision of lock insert, earthing straps, wiring plant pockets, door stay, angle iron frame and grouted in suitable size of platform made of PCC (1:2:4) type-1, panel prewired with suitable multi-stranded, housed with the following accessories :- (a) MCCB 4 pole, 160 Amps, 25 KA with spreader terminals and adjustable thermal setting-01 No (b) MCB DP 63 Amp-04 Nos (c) Aluminium bus bars of rating, 200A, 4 phase of min size 20 x 10mm (d) PVC box for fixing electronic energy meter of suitable size
Supply and fixing storage water heater (Geyser) of 25 litre capacity 230V, AC, 50 Hz having element of 2 KW of COPPER/ INCOLOY alloy, rust proof outer body, high density PUF insulation, BEE 5 star rated and above, inner tnak of SS 304 which can sustain pressure of minimum 8 bar working pressure, making electric and water connection complete all as specified and directed
Supply and energy efficient aesthically designed 2 x 2 LED, IP-55 flat panel for ceiling/ surface mounting which provides soft light and glare free symmetrical illumination environment friendly LED light for ceiling illumination as per national lighting code (SP 72:2010) by using security light of less than or equal to 34W (total input power) CCT 5000-5700K, CRI-67PF>0.95, operating performance temp-10 degree centigrade +45 degree centigrade LED mounted fire span 60000 burning hours external storage and over voltage protection device upto 440V alongwith connection 3 core copper flexible cable size 0.75 Sqmm to be provided with weather proof connector complete all as specified and directed (Porch light)
Supply and fixing ceiling light, round shape, ceiling mounted 18W for mounting in ceiling of porch of the building complete all as specified and directed
Supply and fixing brass chromium plated angle valve, fancy type of size 15mm dia screwed down for high pressure complete all as specified and directed
Supply and fixing PVC connection (hot) superior quality with brass adapter of size 15mm dia x 600mm length complete all as specified and directed
Supply and fixing in position with new no return valve ISI marked made of cast copper alloy screwed both ends internally suitable for iron pipe of size 15mm complete all as specified and directed
Supply and fixing brass chromium plated fancy type bid taps of size 15mm dia bore short body, screwed down for GI pipe or for brass ferrule and fixing complete all as specified and directed
INTERNAL WATER SUPPLY WORKS
Supply and fixing wall mixer with telephonic shower and bib tap cast copper alloy polished body screwed down high presure with cruth or butterfly handle including decorated PVC flexible pipe fancy type chromium plated, screwed both ends for iron or unions for 15mm bore steel tubing complete all as specified and directed
Supply and fixing 15mm bore chromium plated water jet of approved quality to be fixed with EWC including PVC connection of 1.00 m long complete all as specified and directed
Supply and fixing 15mm bore chromium plated health faucet Ald Chr 573mm long flexible tube (silver) of aproved quality to be fixed with EWC complete all as specified and directed Make : Jaquar
SEWAGE DISPOSAL WORKS
RCC septic tank for 100 users designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, RCC M-30 design mix in walls, base slab, balffle walls and roof slab including beams etc with vent, manhoel opening with cover connection etc complete with effective depth of 1.5m and overall depth of 3m complete all as specified.
Soakage wells excavation, in any type of soil, foundation in PCC (1:3:6), wall of honey combed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0M dia x 4.50M effective depth complete all as specified.
EXTERNAL ELECTRIC SUPPLY WORKS
Material and labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 32 x 6mm connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth strip connected to test point and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed. Notes : (i) On testing after completion of job, if desired earth resistance is not obtained, (ii) The earthing shall be redone by the contractor without any extra cost to Govt.
Supply, installation, testing and commissioning in repair of CPRI approved factory made LT feeder pillar box, double door, outdoor, fronts & rear openable type totally enclosed free pedestal mounting dust and vermin proof, weather proof made out of 3.15mm thick CRCA mild steel (certification from manufacturer will be necessary for quality assurance and guarantee) as per IS : 8623 rated for short circuit rating of 35 KA, base frame of 50mm x 50mm x 5mm, with hinges of stainless steel, slider door locks (front & rear), door handles (front & rear) suitable for 415V, 3 phase, 4 wire, 50 Hz, AC supply outdoor type complete with an including incoming and outgoing air circuit breakers/ moulded case circuit breakers, aluminium bus bar including internal wiring with not less than PVC insulated unsheathed 2.5 sqmm multi stranded copper conductor cable, bounding to earth interconnection complete as required and as approved from CPRI all as specified and directed and comprising with following :- Note : Outer dimension of panel should be minimum width = 1.5m, depth=0.4m, height=1.5m INCOMING (a) MCCB 200 Amp, 4 Pole, 36KA with thermal magnetic based, 415V, 50 Hz-01 No. OUTGOING (a) MCB 16 Amp, 10 KA, DP-04 Nos (b) MCB 63 Amp, 10 KA, 3 Pole- 01 No (c) MCCB 100 Amp, 4 Pole, 25KA, with thermal magnetic based, 415V, 50 Hz-01 No. (d) MCCB 160 Amp, 4 Pole, 36KA, with thermal magnetic based, 415V, 50 Hz-02 Nos. (e) Aluminium bus bar suitable for 300A, size 40mm* 10mm (RYBN) covered with heat shrinkable colour coded sleeves (f) Digital LCD multifunctional meter, class 1.0 accuracy displaying voltage, current of all type of phase, frequency complete with 3 CTs of suitable size-01 No. (g) LED indicating lamps (RYB) protected with 2A SP MCB's -01 Set of three. (h) Earthing strip of size 25mm x 5mm of aluminium running throughout the length of the subject LT panel
Supply and fixing in replacement of 90W LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studies excellent corrosion resistant and water proof fixture with efficient heat dissipation design and coating, housing should have two separate compartments for light source and driver compartment. High efficiency LED module with SMD LED package mounted on MCPCB. Driver compartment should be separate accessible and top opening for each of maintenance. LED should be mounted on heat sink conductive aluminium with fence to dissipate the heat to ambient air, covered should be toughened glass/ polycarbonate. Related voltage 240V AC/50Hz operating voltage 140V-270V operative temperature-100C to 500C. Power factor >0.95, average life 50,000 Hrs @ L70. THD<10% with test certificate. CCT 5700K with test certificate. IK-07, CRI>70 with LED lumen efficacy of 135 Lumen per watt and system lumen should be 7400 lumens or above. Driver should be isolated electronic driver with APFC and SMPS based constant current supply with lower THD. Driver shall comply to BIS standard. Valid test report of LM 79 and LM 80 from NABL accredited laboratory need to be submitted. IP 66 protection and surge protection 10 KV built in SPD with 10 KV external also. Driver shall comply safety standard as per IS : 15885 part-2/ Sec 13. Performance requirement as per IS : 16104. Test standard as per IS : 16102 (Part-1) : 2012/IEC : 62560 : 2011. Luminary shall comply to IS : 10322/IEC : 60598 with minimum 5 years warranty complete all as specified
Supply and fixing street light fitting bracket, 1.5m long made out of galvanized iron pipe of 40mm dia size light grade complete with nuts, bolts, washers etc suitable for fixing of 90W LED street light inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as specified
Material and labour for FRLS PVC insulated and sheathed multi stranded copper conductor wire1.00 Sqmm twin core complete for drawing through pole for making connection to street light fitting provided on poles upto junction box including thimbles complete all as specified
Supply and fixing of thermoplastic polycarbonate cable junction box hinged door type of size 200 x 160 x 98mm for P&N incoming cable, 3P&N outgoing cable and single P&N connection for light fitting with terminal block with cage and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision for cable entry through gland alongwith MS clamps and mounting brackets including single pole MCB 10A, 10 KA rupturing capacity as required at site complete all as specified
Supply and fixing bus bar enclosure 800mm x 600mm x 200mm made out of 1.65mm thick stainless steel, 304 grade laminated duly powder coated with and including 160A, 36 KA, microprocessor based MCCB 4 pole fitted in bus bar enclosure using 200A rated aluminium bus bar for all 3 phase and one neutral outdoor type welded to suitable size MS angle iron frame and embedded in PCC (1:2:4) type B-1 complete all as specified. Note : Height of the enclosure from ground level 0.5m
EXTERNAL WATER SUPPLY WORKS
Supply and fixing in replacement of gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe of 80mm dia bore 24 BAR Pn 16 including taking out unserviceable valve complete all as specified and directed
Dismantling old unserviceable valve pits of any size and constructing of brick masonry pits of internal dimensions size 0.6m x 0.6m x 0.6m (bottom PCC floor of the pit should be minimum 30cms below the bottom surface of sluice valve flange to provide sufficient working space), bottom floor of the pit be construction in PCC (1:3:6) 15cm thick with 20mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15mm thick. The sluice valve and other fittings should be housed in center of the pit, the vertices of the pit should in right angle and champhered. The top cover of the pit will be made out of MS sheet min 2mm thick with angle iron frame made out of MS angle 50mm x 50mm x 6mm with galvanized steel hinges two Nos and locking arrangements duly painted with two coats of water resistant synthetic enameled paint over one coat of red oxide complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed
SOLAR WATER HEATING SYSTEM WORKS
Supply and fixing in position with new NRV (non return valve) ISI marked made of cast copper alloy screwed both ends internally suitable for GI pipe of size 20mm bore complete all as specified.
SUMMER APPLIANCES AND SPECIAL ITEM WORKS
Supply and fixing stainless steel rolling drawer pull type suitable for kitchen cabinets with all fixing arrangements area of each drawer n.exc 0.30 sqm of vertical face giving depth 450mm to 600mm complete all as specified and directed
Supply and fixing stainless steel wall mounted auto clean chimney with all fixtures (make Nevion 90 Auto Clean by Hindware) complete all as specified and directed
Supply, installation, testing and commissioning of air conditioner, 1.5 Ton split type (Indoor, outdoor unit) single phase, rotary compressor and condenser coil of copper having cooling capacity 4500K Cal per hour (1.5 Tone), BEE rating 3 star or above refrigerant type R410A/ R32 with cordless remote control unit complete all as specified and directed
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of ± 2.5 % and of capacity 4 KVA complete all as specified.
ARBORICULTURE WORKS
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil, separate the roots/grass and good earth by sieving with suitable sieve size , stacking of good earth & mixed with suitable manure of ratio 5:1 including supply of manure, screened through sieve of 1.5 designation 4.75 mm and spreading the mixture of good earth & manure , applying suitable pesticides , watering to a depth of 15cms, including removal of roots/grass out of site complete all as specified and directed by the Garrison Engineer
Material and Labour for developing Lawn by laying and dibbling of grass Stealers of 'DOOB GRASS' planting , roofing etc complete as approved and as directed by the Garrison engineer
Material & labour for developing and Planting "HEDGES" including 60cm wide laying and dibbling of Soil rows and watering , including excavation post holes for plant as required , returning filling with earth in necessary watering and finally fine dressing, levelling etc and complete including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling , the distance between plants not exceeding 90cms complete all as specified and as directed by the Engineer in Charge. The following species for Hedges shall be used:- (a) Ixora (b) Hibiscus (c) Goudi-Choudi (d) Plumbago (e) Nerium Oleander (f) Tecoma Capsensis Eranthemum Note : The cost of earth, royality, manure & item transportation is deemed to be inlcuded in the unit rate quoted.
Supply & labour for developing and Planting of Bottle palm tree of height not less 4 feet including exavation in post holes of size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Supply & labour for developing and Planting of Gulmohar tree (Delonix regia) of height not less 2 feet including exavation in post holes of size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Supply & labour for developing and Planting of Amaltas tree (Cassia fistula) of height not less 2 feet including exavation in post holes of size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Supply & labour for developing and Planting of Neem tree ( Azadirachta Indica) of height not less 3 feet including exavation in post holes of size 90 cm X 90 cm X 90 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Supply & labour for developing and Planting of Jacaranda mimosifolia tree of height not less 3 feet including exavation in post holes of size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Supply & labour for developing and Planting of Ashok Mast tree (Polyalthia longi folia) of height not less 3 feet including exavation in post holes of minimum size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Supply and fixing for Garden bench 'Three Seater" with overall dimensions of 72" Width x 24" Depth x 33" Height of approved superior Quality of weight not less than 60kgs , sides made out of cast iron with inbuilt arm rest with seat and back made with MS ractagular pipe of size 50mm x 12mm( MS pipe having weight not less than 1.5kg per RM), cast iron legs shall be provieded with MS flat iron lugs of size 40mm x 3mm, 150mm length embeded in PCC (1:2:4) type B1 block of size 200mm x 200mm x 200mm, including provieding two coats of synthetic enamel paint over a coat of red oxide primer to garden bench including necessary earth work complete all as specified and as directed by the Engineer in Charge.
EARTH FILLING WORKS
Material and labour for earth filling for site development brought from outside defence land and lead including watering and well ramming in layers n.exc 25cm complete all as specified and directed.
Gurjit const co
siddharthenterprises
UNITED SAINI BUILDERS
Kartik Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .