| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹5.9 L+₹40,226.68 (7.33%)Accepted-Finance | L2 | Accepted-Finance ok | |
| 3 | L3₹6.2 L+₹75,505.30 (13.8%)Accepted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L3 | Accepted-Finance ok | |
| 4 | L4₹6.7 L+₹1.2 L (21.4%)Accepted-Finance | L4 | Accepted-Finance ok | |
| 5 | Rejected-Technical D 36 1A STREET 3A MADHUBAN MOHALLA NORTH GHONDA DELHI EAST DELHI DELHI 110053 UDYAM DL 05 0014898 | NORTH EAST DELHI | DELHI | 110053 | - | Rejected-Technical Rejected due to Non submission of earnest money FDR |
Tender Value
Refer Docs
EMD Value
₹15,500
Closing Date
27 Jan 2023, 2:30 pmClosed
EE EnM HP-I
DELHI JAL BOARD GOVT OF NCT OF DELHI OFFICE OF THE EXECUTIVE ENGINEER EnM HP I HAIDERPUR WATER WORKS DELHI 110085
Providing and fixing of starter control panels with allied protection at CWPH HP-I.
2023_DJB_235184_5
NIT 20
Open Tender
Miscellaneous Works
Works
90 days
Haiderpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹15,500
3 Feb 2023
20 Jan 2023
27 Jan 2023
20 Jan 2023
27 Jan 2023
20 Jan 2023
Dismantling of existing control panel boards/MCB Enclosures, dismantling cables from dewatering pumps as per site requirements, dismantling wiring connections from MCB Enclosures including dismantling the lightning connections and cable connections from motor and pumps
Supply of Encloser Panel Size – (H) 1500mm x (D) 300mm x (W) 1050mm (Approx.) 16 Gauge CRCA Sheet Powder Coated Double Door IP65 waterproof panel with complete in all respects including angle stand, lock, required logo and all accessories
Supply of Amp Meter 1 Phase. Make: - HPL/ L&T /Any DJB approved make.
Supply of Volt Meter 1 Phase.Make: - HPL/ L&T /Any DJB approved make.
Supply of ASS 6A Make: - L&T /Salzer/Any DJB approved make.
Supply of VSS 6A Make: - L&T /Any DJB approved make.
Supply of DP MCB 6 amps. to 32 amps. ratings, SPN MCB, “C” curve, 10 KA with breaking capacity
Supply of MCB 63A / 4P / C-Curve.
Supply of 63 A, TPN, Switch disconnector fuse unit (Panel mounted type) with ISI marked.
Supply of DP MCB 40Amp C-Curve.
Supply of MNX 32 Contactor 3 Pole. Make: - L&T /Siemens/Any DJB approved make.
Supply of Add ON Block 2NO/2NC. Make: - Siemens /Schneider/Any DJB approved make.
Supply of MN2 overload Relay (14-32A). Make: -L&T /schneider/Any DJB approved make.
Supply of SM 501 Relay. Make: - L&T /Any DJB approved make.
Supply of Push Button Make: - L&T
Supply of Indication Lamp. Make: -L&T /Any DJB approved make.
Supply of CT Specification as required for panel - 60/5 A and 30/5 Amp. Make: - L&T /Any DJB approved make.
Supply of Miscellaneous Items Like – Control Cable / Busbar / Lugs / Thimbles / PVC Tape / Ferul / Spiral Tube / Cable Tie/MCB Bars & Hardware/MCB Enclosures with Lock system
Supply of LT Aluminum armored cable 4 core 16mm2 Make – Grandlay / Havells/ Polycab
Installation of Panel at site including supply of MS angle as required for mounting of panel above surface with civil works complete in all respects such as digging, grouting. installation on MS angle platform and making the surface even with all required masonry items
Supplying and installing following sizes of perforated painted with powder coating M.S. Cable trays with perforation of not more than 17.5% in convenient sections, Joined with connectors ,suspended from the ceiling with M.S. Suspenders including bolts and nuts painting suspenders as required A) 450mm width X 50mm depth X 2.0 mm thickness
Fixing the all material such as installation of Contactor, Timer, Overload relay in newly installed panel etc. with proper cable termination for Incoming& Outgoing with making DOL system for 10 HP dewatering pumps and connecting the panel with supply as required at site, including installing the MCBs in panel and making connections of all lights, Exhaust fans and air circulator with thimbling etc..
Making connection with dewatering pumps with newly installed Panel including thimbling taping etc.
Laying of cable 4 Core 16mm2 from source to panel including fixing with laying on cable trays or as required etc.
Testing and commissioning of Panels on load including testing of all required parameters
Raj Engineering Co.
Premier Engineering Company
Blueage printech pvt. ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .