Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.7 L+₹2.6 L (6.55%)Rejected-AOC | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹43.0 L+₹2.9 L (7.22%)Rejected-AOC | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹44.0 L+₹3.9 L (9.79%)Rejected-AOC | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹44.6 L+₹4.6 L (11.4%)Rejected-AOC | L5 | Rejected-AOC Being not L1 |
Tender Value
₹48.2 L
EMD Value
₹96,320
Closing Date
24 Sept 2021, 6:00 pmClosed
GARRISON ENGINEER NORTH SECUNDERABAD
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
SPECIAL REPAIRS WPT TO ROOF IN JCOS ORS MD ACCN BLDG NO P130 133 AND 134 OF 1TB 1EME CENTRE AND CERTAIN MINOR AND REVENUE WORKS UNDER GE NORTH SECUNDERABAD
2021_MES_468765_2
8997
Open Tender
Civil Works
Works
180 days
Garrison Engineer North 35 Allenby Lines Secundera
For Enlisted Contractors Class D Category ai and for Un Enlisted contractors meeting the Enlistment criteria for appropriate class and category along with EMD
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH SECUNDERABAD
₹96,320
Yes
20 Jan 2022
3 Sept 2021
27 Sept 2021
3 Sept 2021
24 Sept 2021
11 Sept 2021
3 Sept 2021 - 10 Sept 2021
Amount
Dismantling floor, hearth or wall tiling/Cladding including cement mortar bedding (but not backing), removing serviceable slabs / tiles to MES store and yard and rubbish off the premises complete all as specified and as directed.
Taking down chowkats or frames not exceeding 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4 sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down cement plaster of any thickness on brick or stone walls or concrete surface including raking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
Demolition of Brickwork built in cement mortar including all quoins, pillar etc, but excluding ashlar facings, dressed stone-work and remove from site complete all as specified and as directed.
Cutting out concrete blocks,slabs, brickwork or stone masonry (in alternate course), forming tooth-ings for and bonding new work in mortar into oldwork, including new materials entering old wall complete all as specified and as directed.
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing jointing and pointing to match existing work, complete all as specified and as directed.
M & L for rendering 15mm thick in cement plaster 1:6 of any faces of brick walls work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for chequered cement concrete tiles 30cmx30cmxx25cm machine pressed, set, jointed and pointed in neat cement slurry in floors, with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M & L 100 mm thick PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base floor, paving complete all as specified and as directed.
M&L for 10mm thick vitrified tiles light shade double charged polished area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles 450x300x7mm thick on vertical surfaces such as dados set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick backing coat in CM 1:4 complete all as specified and as directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed.
M & L for preparation of new plastered wall surfaces and applying two coats of distemper oil emulsion over a coat of smooth putty finish and primer complete all as specified and as directed.
M & L for complete removal of existing treatment of wall and apply two coats of distemper oil emulsion over a coat of smooth putty finish complete all as specified and as directed.
M & L for preparing old decorative surfaces of walls, by washing, rubbing down, stopping and applying two coat of cement base paint of any colour complete all as specified and as directed.
S&F for aluminum alloy anodised powder coated window frame with glazed/guaged shutter sliding type standard section incl standard alumn alloy anodised beads snap type rubber gasket, handle, locking arrangement and other necessary fittings including aluminium grill complete incl glazed clips and jointing cleats and fixed complete all as specified. Window frame to be fixed on wall/floor/RCC member with rawl plug and 5mm thick toughened glass panes and stainless steel fly proof mesh will be fixed complete all as specified and as directed at site. All builder hardware will be of alumn alloy anodised
S&F for aluminum alloy anodized powder coated door frame of section 100 mm x 44 mm x 2mm thick,door shutter of aluminum section of size 85 mm x 44 mm x 2mm thick, top rail and both styles of size 100mm x 44 mm x 2mm thick,lock rail and bottom rail of size 115 mm x 44 mm x 2 mm thick including aluminum anodized snap beading and rubber packing,& 5.5 mm thick plain or tinted glass/9mm thick prelaminated particle board, including 200 mm long tower bolt, 200 mm long Aluminium handle- 02 Nos on each leaf, 4 lever, 100 mm long brass mortice lock, & double action floor door spring heavy duty (Make:Sandhu / Samrat or equivalent as approved by GE) suitable for 1m wide shutter for each leaf complete all as specified and as directed.
S&F for aluminum alloy powder coated anodized Partitions with hollow aluminum anodized standard sections as specified including aluminum alloy anodized snap type beads dish type glazed clip joint cleats, rubber gaskets, etc with including 5.5 mm thick tinted glass and prelaminated particle board including all standard fittings complete all as specified and as directed at site.
Providing and fixing in repairs false ceiling of Armstrong Mineral Fiber Acoustical Suspended Ceiling System with FINE EDGE TILES ARMSTRONG SILHOUTTE EXPOSED GRID SYSTEM. The tiles should have humidity Resistance (RH of 99%, NRC 0.55 Light Reflectance 85% thermal conductivity K=0.052-0.057 w/m k. colour white, fire performance class O class 1 (BS476 Part 6&7) in module size of 600 x 600 x 16mm with Bio black coating on the face of the tile, suitable for Green Building application, with the recycled content of 63%. The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white /black colour and with a web height of 45mm and a load carrying capacity of minimum 15.68Kg per squaremetre. Sihouette, main rammers & cross Tees to have mitred ends and "birds mouth" notches to provide mitred cruciform junctions. The Tee Sections have a galvanizing of 120 grams per squaremetre & passed through 500 hrs of salt test. The quoted rate is deemed to be inclusive of cost of necessary scaffolding work required to carry out the job.
S&F PVC coated aluminium drapery curtain rod 32mm dia coloured with pair of suitable brackets and fennels as approved by GE including taking down old pelmet boxes with curtain rods complete all as specified and as directed. Make: vista cat part no-BG-006 florena-III or equivalent as approved by GE.
Supply and fix in repairs door closer, hydraulically regulated, aluminium body designation No 2 universal type (ISI marked), suitable for shutters of 701 to 850 mm width of weight between 36 to 60 Kilo gram fixed complete all as specified and as directed.
M&L for granite slab flooring 20 to 25 mm thick machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing over 20 mm thick screed bed in CM 1:6 including making hole in platform for gas pipe complete all as specified and as directed.
Rounding to edges of stone slabs one edge such as in steps cooking platform and other similar situations complete all as specified and as directed.
Supply and fix in repairs 50mm bore low density polyethylene pipes (LDPE) of pressure rating 6kg/cm2 laid in floors for spouts in sunken floors complete all as specified and as directed.
Supply and fix in repairs 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches, wall or in floors complete all as specified and as directed.
Supply and fix in repairs 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches, wall or in floors complete all as specified and as directed.
S & F in repairs PVC (SWR) bends 75mm bore, any radius with oval access door complete all as specified and as directed.
S & F in repairs PVC (SWR) bends 110mm bore, any radius with oval access door complete all as specified and as directed.
Supply and fix in repairs 75 mm bore PVC (SWR), junction single (single T) equal or unequal complete all as specified and as directed.
Supply and fix in repairs 110 mm bore PVC (SWR), junction single ( double T) equal or unequal complete all as specified and as directed.
S & F in repairs 110mm dia vent cowl complete all as specified and as directed.
Supply and fix in repairs PVC (SWR) floor trap of 75mm dia, plain with grating including jointing with solvent cement complete all as specified and as directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet & edges will be painted to match with printed sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
S & F Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet polyrethane painted on front face & 2mm thick plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed.
S & F 100 butt hinges extruded aluminium alloy with galvanised mild steel hinges complete all as specified and as directed.
S & F 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S & F 150 mm size extruded aluminium alloy handles fabricated type, anodised complete all as specified and as directed.
Taking up & down steel tubing & connections including cleaning for refixing or removal to store 15mm dia complete all as specified and as directed.
Taking up & down steel tubing & connections including cleaning for refixing or removal to store 20mm dia complete all as specified and as directed.
Taking up & down steel tubing & connections including cleaning for refixing or removal to store 25mm or 32mm dia complete all as specified and as directed.
Taking up & down steel tubing & connections including cleaning for refixing or removal to store 40mm dia complete all as specified and as directed.
S&F 15mm dia steel water tubing medium grade galvanised with all fittings & fixed complete to walls & ceilings or laid in floors complete all as specified and as directed.
S&F 20mm dia steel water tubing medium grade galvanised with all fittings & fixed complete to walls & ceilings or laid in floors complete all as specified and as directed.
S&F 25mm dia steel water tubing medium grade galvanised with all fittings & fixed complete to walls & ceilings or laid in floors complete all as specified and as directed.
S&F 40mm dia steel water tubing medium grade galvanised with all fittings & fixed complete to walls & ceilings or laid in floors complete all as specified and as directed.
S & F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs including taking down the existing fitting complete all as specified and as directed.
Disconnecting existing tanks, setting aside ( or lowering if required) for repairs/replacement, cleaning etc.,and hoisting if required reconnecting and re-fixing in position. ( cleaning repairing etc., measured separately) of tank capacity exc 250lit but n.exc 500 lit complete all as specified and as directed.
Dismantling water tanks and (exceeding 250 and not exceeding 500 ltr capacity) complete all as specified and as directed.
S&F rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I capacity of tank 500 ltrs triple layered complete fixed in repairs complete all as specified and as directed.
S & F in repairs 20 mm dia PTMT ball Valves, high pressure, with polythene float and fly nut complete, screwed for Iron pipe or brass ferrule including taking down the existing valve complete all as specified and as directed.
M&L for 75 mm thick plain cement concrete 1:3:6 mix,type C1 (using 20mm graded stone aggregates) as in subbase to floor complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided in roof padding concrete complete all as specified and as directed.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded stone aggregate with WPC 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and necessary formwork etc ete complete all as specified and as directed.
Material and labour for application of one coat of water based bitumen emulsion primer at the rate of 0.3 litres per square metre after cleaning of the surfaces thoroughly from dust, dirt and projections and applying water proofing treatment with APP based polymeric membrane of weight 3.5 Kilogram per square metre and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 grams per square metre) as per IS 3384 on primed surface by forced application over roof surfaces with the over laps of 10 centimetres APP, membrane grit finish on roof slab all as per manufacturer's instructions and zonal specification etc complete all as specified and as directed.
M&L for 20mm thick screed bed in CM 1:4 duly mixing with water proofing compound at the rate of 3% by weight of cement or as per manufacturer's instructions surface etc complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately under relevant item in this schedule
M&L for laying 300 mm x 300 mm x 20 mm thick PCC tiles (Hydraulically pressed) with grey cement, set, jointed, cut and polished. The joints shall be grouted and immediately after grouting, the joints shall be pointed flush in in CM 1:3 mixed with 150ml per kg of cement of polymeric based liquid water proofing additive by weight of cement or as per manufacturers instructions etc all as specified and directed. Note : Supply of polymeric based liqluid water proofing compound will be measured and paid separately.
Supply only polymer based lilquid water proofing compound complete all as specified and as directed.
M&L for making the grooves to 'V' section in existing parapet walls/columns over RCC roofs, cleaning out and tacked the polymeric membrane in to the grooves and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and as directed.
Material and labour for rendering 10mm thick on roof surfaces in cement mortar 1:4 duly mixing with water proofing compound at the rate of 2% by weight of cement and finished even and smooth complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately under relevant item in this schedule
Supply only water proofing compound of ISI marked complete all as specified and as directed.
Material and labour for application of one coat of water based bitumen emulsion primer at the rate of 0.3 litres per square metre after cleaning of the surfaces thoroughly from dust, dirt and projections and applying water proofing treatment with APP based polymeric membrane of weight 3.5 Kilogram per square metre and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 grams per square metre) as per IS 3384 on primed surface by forced application over roof surfaces with the over laps of 10 centimetres over that a coat of blown bitumen of 85 / 25 at the rate of 1.2 kilogram per square metre over that a coat of bituminous aluminium paint at the rate of 100 grams per square metre for inaccessible roofs complete all as specified and as directed.
M&L for filling cracks with polymer based chemical (Dr fixit cracks shrink free ) for cracks not exc 10 mm in width as per manufacturer instruction on wall surfaces on concrete or masonry including scaffolding etc complete all as specified and directed. Make:- Dr fixit /Berger / Fosroc
M&L for removal of loose and disintegrated concrete of RCC structural members viz slab, beam, column and lintel etc by low impact hammer including removal of debris outside MD land. Cleaning the surface by high pressure water jet or by air blast and exposed reinforcement bars with wire brush and apply two coats of anti-rust protective chemical at suitable intervals all as per manufacturer's instructions to resist further deteoration of reinforcement bars , including use and waste form work and providing welded wire mesh size 100 x 100 mm of wire 3,and using Spray gun pressure guniting in CM 1:3, 30mm thick finishing the guiniting surfaces in cement mortar 1:3, 10mm including using water proofing compound 2% by weight of cement and finishing even and smooth without using extra cement to match the existing surface, and unit rate quoted shall include for necessary scaffolding, trestles, ladders & cradles required for execution of the work and protective works complete all as specified and as directed.
All as per item No 65 above but for slabs / chajjas and thickness of guiniting 25mm and finished even and smooth with 5mm thick cement plaster 1:3 including using water proofing compound 2% by weight of cement complete all as specified and as directed.
M & L for rendering 10 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement in patches n exc 3 sqm each patch all as specified and as directed.
M & L for rendering 5 mm thick in cement plaster 1:3 on concrete surfaces of ceiling finished even and smooth without using extra cement in patches n exc 3 sqm each patch complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two coats (10 + 5 mm), both coat mixed with integral water proofing compound ISI Marked @ 2% by the weight of cement and finishing the surface even and fair complete all as specified and directed Note - WPC shall be measured and paid separately
M & L for preparing newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of new plastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of apex ultima weather proof paint over a coat of apex ultima primer including preparation of surfaces etc all as specified and as directed.
Material and labour for complete removal of the existing surfaces of walls/bands/slabs up to any height and applying two coats of weather proof paint of any colour (ACE Paint) over a coat of smooth external putty finish complete all as specified and as directed
Cutting down plants/trees of girth n exc 15 cm from roof tops/sides of external walls of buildings, chajja, wall junctions, junctions of rain water/soil/waste vent pipes including taking out roots entered in wall/slab surfaces and making good the surfaces including repairing the CI/GI/PVC joints of affected locations by applying TUFALO (Herbal medicine) and making good to suit the adjoining surfaces using PCC type 1:2:4, type B-0 or cement mortar 1:2 with necessary scaffolding/staging etc up to any height complete all as per manufacturer instructions and complete all as specified and as directed. NOTE: Any CI/GI/PVC pipes and fittings damaged during work shall be replaced by new one to ensure leakage/seepage free joint without any extra cost to the department.
Demolition of PCC of any description and in any position not otherwise specifically provided for(un-reinforcement ) and removal of rubbish/ demolished materials out of MD land complete all as specified and as directed.
M&L for 75 mm thick plain cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregates) as in sub base to floor complete all as specified and as directed.
M&L for designer rubber moulded chequerred cement concrete tiles with mixture of grey and white cement in equal proportions with pigments of size 300 x 300 x 22mm or 250 x 250 x 22mm thick and set and pointed in neat cement slurry in floors over a screed bed or bedding layer in CM 1:6, 15mm thick for laying floor finishes etc complete all as specified and as directed.
M & L providing, cement concrete Type B1 1:2:4 (20mm graded stone aggregate) as in copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, including necessary form work complete all as specified and as directed.
Supply, lay and testing on site LLDPE septic tank of conventional type designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 30 users capacity complete all as specified and as directed. Make: Sintex/Polycon/Plasto as approved by GE.
Provision of soak well of size 1.8m dia x 3.0m deep including exceeding in ordinary soil, foundation in PCC 1:3:6, well of honey combed and solid in M25 concrete, including intercepting chamber screen chamber brick work in CM, RCC cover slab in M25/RR masonry/filling with brick bats complete as per drawing No TD/ST/748, Sheet No 1/1 dated 22 Jan 2011 and complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres deep for laying of drain pipes etc., for manholes for foundation etc, and getting out in hard and dense soil complete all as specified and as directed
Material and labour for reinforced concrete pipes, class NP3 150 mm bore laid in trenches with one collar per length and jointed with cement joints complete all as specified and as directed
Material and labour for concrete bed to drain pipes of 150 mm dia including packing under and haunching against the sides of pipes with concrete, after they are laid including testing in plain cement concrete 1:3:6, type C2 using 40 mm graded aggregate with necessary form work complete all as specified and as directed
M&L for plain cement concrete 1:4:8 type D-2 ( using 40mm graded stone aggregate ) in foundation filling and mass concrete complete all as specified and as directed
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in each layers hard/dense soil complete all as specified and as directed.
Removal of excavated material in soil to a distance n exc 50m and depositing where as directed at a level n exc 1.5 m above the stating point complete all as specified and as directed.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces built in cement mortar 1:4 and finished even and smooth without using extra cement duly mixing the water proofing compound at the rate of 2% of weight of cement complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately under relevant items in this schedule.
Material and labour for providing precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in cover slabs,manholes and similar articles with plain faces with plain fair faces including chamfers, weatherings, throating etc and set in cement mortar 1:4 including necessary form work complete all as specified and as directed.
Supply and fix in position TMT bars 8mm dia cut to length, bent to shape required including cranking, bending, spirally hooking for ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed
Cutting into existing manholes for connecting new drain, making good to pipe and rendering, cutting out existing benching for end forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 200 mm internal dia of pipe all as specified and as directed.
Surface excavation not exceeding (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
S&F Mild steel work for joints channel, angle or tee section, fixed independently, without connecting plates ,ladder , grating of open drain and similar work etc conforming to Fe 410-W Gde E-250 quality A and complete all as specified and directed. .
S&F for Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming to Fe 410-W Gde E-250 quality A and complete all as specified and directed.
S & F MS steel work in tubular/roof trusses (framed),purlines,rafters etc, complete including necessary cutting, welding,fabrication and erection Machine hydraulic bending etc complete using ERW pipes or induction butt welded tubes, conforming to IS 1161-1979 (Gde E-250) quality-A, complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces complete all as specified and as directed.
M&L for providing precast concrete block masonry with solid block n.exc 20 cm width type C1 1:3:6 setting in cement mortar (1:6) complete all as specified and as directed.
M&L for cement concrete type B-1, 1:2:4 ( 20mm graded aggregate ) as in surface channels and drains etc complete all as specified and as directed.
E/M Items : M & L for Point wiring with 1.5 Sq mm copper conductor single core FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC conduit concealed and conduit accessories of suitable dia medium grade of size not less than 20mm dia and pressed steel terminal boxes suitable for MODULAR switches size including fixing/grouting sunken/ surface as per site requirement covered with suitable modular white cover plate for fixing switches / sockets/ regulators etc including running up of 1.5 Sq mm copper conductor FRLS PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed :- (a) One light/ Bell point Ceiling/ exhaust fan controlled by one, one way switch 5/6 amps, SP
All as per Item No 97 above but for one 3 pin 5/6 Amps switch socket outlet point controlled by one switch on independent board.
All as per Item No 97 above but for one 3 pin 5/6 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 97 here in before but using 2.5 Sqmm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm copper conductor FRLS PVC insulated cable as earth continuity conductor complete all as specified and directed.
S & F Switch MODULAR 1 WAY 6 amps, 230 volts complete all as specified and directed.
S & F MODULAR socket 5 pin 6 amps 2 MODULE230 Volts complete all as specified and directed.
S & F MODULAR socket 6 pin 6 /16 amps 2 MODULE230 Volts complete all as specified and directed.
S & F Switch MODULAR one way 16 amps, 230 volts complete all as specified and directed.
S & F Switch MODULAR bell Push 6 amps, 230 volts complete all as specified and directed.
S & F bidirectional fancy holder with plate (metal ring) complete all as specified & directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified. complete all as specified and directed.
S & F call bell ding dong AC,230 Volts,single pole complete all as specified and directed.
S & F wall mounted LED Batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 1x20 w watts, 230 volts, bipin holders, DIFFUSED TYPE connector block, internally pre wired etc with necessary mounting arrangements including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting all as directed by Engineer-in-charge. Make : C&S cat No - LTIC00120WLED/WD, Havells cat No-REGALBATTENT8UPTO1X22WSSBSWH incl Tube Rod cat No-PHOTONULTRAE2.01213T8SSTL20WLED8655PC, Wipro cat No WI0921208 incl Tube Rod LL13-181-65SE.
Supply and fix recess mounting with perforated sheet with electronic driver luminaire 36 watts LED slim panel with central opal diffuser series mounted in ceiling surfaces including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make - C&S , Cat No - LTCRSLM36WATT2X2, Havells Cat No - STARTO2X2PLR36WLED840MOD incl driver LED DRIVER36V36WS, Wipro Cat No - CRCO23R036HP65G3.
Supply and fix sheet metal enclosure MCB DB SPN 8 Way with 200 Amps rated bus bar of 240 Volts, double door with magnetic locking system for fixing MCB’s / isolators including taking down existing old unserviceable MCB DB complete all as specified and as directed. Make- Havells, Standard, C&S
S & F MCB SPN 40 to 60 Amps 240 volts, C SERIES for fixing on MCB DB complete all as specified and as directed. Make- Havells, Standard, C&S
S & F MCB SP 6 to 32 Amps 240 volts "C" series for fixing on MCB DB complete all as specified and as directed. Make- Havells, Standard, C&S
M & L Submain wiring with 2 runs of single core 6 sqmm FRLS PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid PVC conduit concealed and conduit accessories of medium grade not less than 25 mm dia including one run of single core 6 sqmm FRLS PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed. Note: 1. Two runs of 6 Sqmm cable and one run of 6.0 Sqmm cable and one run of 25mm conduit will be measured as one length.
M & L Submain wiring with 2 runs of single core 4 sqmm FRLS PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit concealed and conduit accessories of medium grade not less than 20 mm dia including one run of single core 4 sqmm FRLS PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed. Note: 1. Two runs of 4 Sqmm cable and one run of 4.0 Sqmm cable and one run of 20mm conduit will be measured as one length.
S & F sheet steel MS enclosure earth plug socket 2 pin 20 amps with metal top 20 amps with MCB 32 Amps complete all as specified and as directed. Make- Havells, Standard, C&S
Supply and install hi wall spilt units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 TR complete all as specified and as directed. Make: Blue Star, Hitachi, Daikin.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5KVA complete all as specified and as directed.
S&F Sheet metal enclosures with socket plug to and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 32Amps, 10KA, "C" Curve, 240V complete all as specified and as directed.
M&L for Submain wiring with PVC insulated unsheathed cable, 1100 volts, grade multistranded fire retardant low smoke copper conductors, two runs of single core 6 Sqmm conforming to IS-694, drawn through and including 25mm dia nonmetallic rigid PVC conduit, conduit fitting and conduit accessories along with one run 6Sqmm PVC insulated single core multistranded fire retardant low smoke copper conductor cable as earth continuity conductor run along the pipe concealed in stone /brick on wall / roof and connecting to common earth dolly complete all as specified and as directed. Note: - 1. Two runs of 6 Sqmm cable and one run of 6.0 Sqmm cable and one run of 25mm conduit will be measured as one length. 2. Chasing of walls for concealing pipes and cost of terminal box is deemed to be included in the item rates quoted for submain wiring.
S&F MCB 6-40 Amps, SP, 240 Volts, 50 Hz, AC Supply, "C" Curve with breaking capacity of 10 KA complete all as specified and as directed. Note: Make shall be of Legrand Cat No. 6032 31-37 or equivalent of makes as listed here-in- after.
Supply and fix Heavy duty Exhaust fan, metal body, 300mm sweep, 1400 RPM 230 volts AC Supply all as specified and as directed.
M & L making hole to fix the exhaust fan and making good to the disturbed surfaces with cement mortar complete all as specified and as directed.
S & F louvers for 300mm sweep exhaust fan complete all as specified and as directed.
Supply & Fixing ceiling fans complete with blades, down rods and accessories, 230V, 1200mm sweep.Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. Make: Bajaj/Havells/Usha.
B/R Items Disconnecting existing tanks, setting aside ( or lowering if required) for repairs, cleaning etc.,and hoisting if required reconnecting and re-fixing in position. ( cleaning repairing etc., measured separately) of tank capacity exc 500ltr but not exceeding 1000 ltr complete all as specified and as directed.
Dismantling water tanks and (exc 500 and not exc 1000 ltr capacity) complete all as specified and as directed.
S&F rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I capacity of tank 1000ltrs triple layered complete all as specified and as directed.
SURA INFRASTRUCTURE
A SOMA RAJU
PAVAN ENTERPRISES
K LAKSHMAN SINGH AND CO
M/s GM Constructions
STANDARD AGENCIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .