| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | ₹1.1 Cr | L1 | Accepted-AOC The lowest and negotiated tender is approved by Chief Engineer PWD, Coimbatore Region, Coimbatore Letter No. HDO/ DB/ F.12 / 2026/ dt.02.02.2026 |
| 2 | L2₹1.2 CrRejected-AOC 2 209 1 NANGAVARAM ROAD PERUGAMANI POST SRIRANGAM TALUK TIRUCHIRAPPALLI | TIRUCHIRAPPALLI | TAMIL NADU | 620001 | ₹1.2 Cr | L2 | Rejected-AOC Other than lowest tenderer |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-The bidder has not uploaded the Live certificate for PWD Registration |
| Sl No | Description | Qty | Unit | rv electricals L1 | GANAPATHY ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00 | Supply, erection, testing and commissioning of 1000 KVA, 11KV, 433V, HV - Delta, LV Star off load tap changing, copper wound, outdoor type with off circuit (level - 1 ) As per IS 1180 Oil Cooled Distribution Transformer as per IS 1180(Level I) ON AN cooled, confirming to relevant IS 1180 / IEC 60076, Level-II Class A Insulation and mounted on 300 x 90 x 6mm base channel bolted to a suitable RCC plinth of height 5' and RCC foundation to a depth of 2' with reinforcement by suitable MS rods 150Kg / m3 capable of bearing 2 ton weight and connected works fitted with the following:
1) HT Cable End box suitable for connection of 11KV 3c x 300 sq.mm HT cables & LT Cable end box suitable for 2runs x 3c x 300 Sqmm cable
2) Bucholz relay with shut off valve, alarm and trip contacts.
3) Dehydrating silica gel breather.
4) Conservator with oil filling pipe, cap and drain plug valve. | 1 | No | 23,92,000 ₹23.9 L | 25,30,000 ₹25.3 L |
| 1.015) Tank drain cum bottom filter valve with plug. 6) 4 Nos. plain rollers uni and bi-directional under base channels with skid.7) Dial type thermometer with pocket to measure oil temperature stem type. 8) Tank top filter valve with plug. 9) Explosion vent with diaphragm. 10) Oil level gauge with marking. 11) Two body earthing terminal and additional neutral bushings for solid earthing. 12 Rating and terminal marking diagram plate. 13) Lifting hooks/ Lifting eyes/ Jacking pad to facilitate easy movement of Transformer to ground level, cover lifting lugs. 14) Off load hand operated tap changing switch at standby height from ground level. 15) Tapping on primary winding for voltage variation +5% to -5% in steps of 2.5%. 16) Welded and detachable radiators. 17) Air release device. 18) The transformer should be supplied with first filling of oil as per IS 335 with high dielectric strength, BDV and flash point. 19) Monogram plate. 20) Shut off valve for surge relay 21) Oil surge relay 22) All removable covers shall be provided with weather proof hot oil resistant, resistance gaskets to prevent leakage of water into core, and oil from the tank with low no load loss 1100W and full load loss 6400W, impendence 5% with temperature rise oil / winding 50° - 55°C(Make: CREL / Rowsons/SPS or its equivalent) (SR) (M-1940) | |||||
| 2.00 | Design manufacturing Supply, erection, testing commissioning and handing over of 11KV, 25KA 630A Indoor HT Single panel Vaccum circuit breakers comprising one number 630A, 25KA VCB as Outgoing and adopting with existing three panel VCB for indoor installation. Each panel comprising of
1) Draw out type 11KV 630A 25KA Horizontal Draw out/Horizontal Isolation Vaccum Circuit Breaker as outgoing 1 No Draw out type 11KV 630A 25KA Vaccum Circuit Breaker as outgoing each VCB consists motor operated spring charged mechanism, Anti pumping device, 110V DC shunt trip and closing coils DC source of supply to be derived from a Power Pack suitable for 3 Tripping and Two closing operation counter, 6NO + 6NC spare Aux, contact for customer use, Automatic safety shutter, mechanical Close/ Trip Knob, Mechanical ON/OFF indication Operating Handle, 110V AC - 110V DC Power Pack Etc.,
3) Current Transformer of 100 - 50/5-5Amps Dual core (Core 1 - 15VA class 1 for metering and core 2 - 15VA 5P 10 for protection) for Incoming, 4 Nos Current transformer of 30/5 - 5Amps Dual core (Core 1 -15 VA Class 1 for metering and core 2 - 15VA 5P 10 for Protection) for out going 3Nos.
4) METERS
Digital Ammeter with selector switch | 1 | No | 5,16,880 ₹5.2 L | 5,47,000 ₹5.5 L |
| 2.015) PROTECTION Numerical Non directional IDMT combined 30/C +1 E/F relay with highset. Highspeed / Master trip relay (EMR151) Transformer fault annuciation relay. INDICATION LAMP 6) Phase Indicating Lamps RY and B (Incoming 3 Nos.), Breaker ON indication (Red- 5nos), Breaker OFF indication (Green- 5nos), Breaker TRIP indication (Orange - 5nos), Trip circuit Healthy indication (Yellow - 5nos) 7) Control wiring 8) 630Amps Copper Bus Bar PVC sleeved and required panel copper earthing. 9) Control Switch TNC (Incoming 1 no. outgoing 3Nos) 10) Trip Circuit Healthy Push Button (Incoming 1 No. outgoing 3Nos) 11) Common for Switch gear, MCB’s for AC / DC Control Heater ON/OFF switch with space Heater and thermostat single phase Switch socket, cubicle illumination lamp, Disconnecting type terminal Block etc. MS sheet enclosure for Indoor Installation powder Coated with paint shade Siemens Grey. Provision through Bottom entry to receive Incoming or out going cable excluding cable glands and cable terminal kit. (Make : Safevolt / Mega win electro technical / Sriwin electric ) (SOR) | |||||
| 3.00 | Interconnection of proposed single panel 630A VCB to the existing three panel VCB as one of the outgoing feeders with necessary busbar arrangements with proper interconnections in complete. (Quotation) | 1 | Job | 26,000 ₹26,000 | 28,000 ₹28,000 |
| 4.00 | Design, Supply, erection, testing and commissioning of 1250A draw out type floor mounted MV cubical bus bar chamber dust and vermin proof and accommodating the following SDF’s and 1 No. ACB as Incomer units and 1 No 1250A draw out type ACB with the following items of work complete to satisfy the latest IE rules and CEIG guidelines.
Supply and fixing of suitable bus bar chamber made up of 16SWG MS sheet steel with 2Nos. of 4” X 1/4” tinned copper bus bar for 3 phases and neutral and 1Nos. of earthing bus of size 1” X 1/8 tinned copper bus on suitable bus bar insulator (Epoxy insulator) with maximum creepage distance and supported on MS Base channel frame work of size 4”X 2”X ¼”–1Set
Incoming
1)Supply and fixing of 1 No. 1250A basic rating 4 pole 433V
LT ACB confirming to IS 13947–2 IEC 60947–2 with making capacity of 50 KA and breaking capacity of 690V AC with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing release forover current protection UV release with time delay, EF release short circuit protection,
Mains CTs for 3 phases lockout, features, separate mould base for each pole for easy maintenance all relevant protection safety accessories as per CEIG, IE rules inforce with inter connection and terminations as required in specification. | 1 | No | 22,58,610 ₹22.6 L | 23,88,000 ₹23.9 L |
| 4.01Outgoing: 1)Supply and fixing of 1 No. 800A basic rating 4 pole 433V LT ACB confirming to IS 13947–2 IEC 60947–2 with making capacity of 50 KA and breaking capacity of 690V AC with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing release forover current protection UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mould base for each pole for easy maintenance all relevant protection safety accessories as per CEIG, IE rules inforce with inter connection and terminations as required in specification.2)Supply and fixing of 4 Nos. 630A 4 pole switch disconnector fuse unit in sheet steel enclosure. 3)Supply and fixing of 4 Nos. 400A 4 pole switch disconnector fuse unit in sheet steel enclosure. 4)Supply and fixing of 4 Nos. 250A 4 pole switch disconnector fuse unit in sheet steel enclosure. The bus bar chamber will consist of 4nos of suitable size of copper flat for phase and neutral buses on epoxy moulded bus insulators at proper and sufficient spacing between the buses as per IE rules. This bus bar chamber should be segregated from the adjacent chambers by providing hylem sheet of suitable thickness as partisans suitable size of copper flats should be provided all round the panel for earth bus. | |||||
| 4.02The fuse switches should be connected with the phase and neutral buses with suitable size of copper rod or flat and each switch should be connected with earth with 2 nos. earth bus with 2 runs of No:8 SWG rigid copper rod with suitable lugs. Phase and neutral copper buses should be tinned properly. The panel should have a separate metering chamber at the top side consisting of 0-500V Digital Volt meter with selector switch 0-400A Digital Ammeter Selector switch and CT arrangements LED indicator lamps should be provided with control switches and fuse units. The panel should be painted with one coat of Red oxide as primer coat and two coats of enamel paint of approved colour, Approved by the site engineer and also the danger board. The capacity of fuse switches, size of the incoming and outgoing cables, the place to which the supply is fed shall be marked on switch chamber. (DATA-1) | |||||
| 5.00 | Design, supply, erection of 200KVAR, 12 stage switching, sequence automatic power factor correction wall mounting stand vermin proof cubical panel board made of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting capacitor chamber relay with metering chamber and compartmentalised out going feeders with suitable capacity MCCB with panel board with provision for louvers and cooling fan for proper ventilation to manage heat load incoming - 630A FP MCCB with rotary handle.
Outgoing : 12 stage capacitor bank
Contactors : Bharatia Cuttler Hammer/ L&T Heavy Duty contactors.
Relays : World class solid state relays with TM2 technology as an option.
Capacitor MPP capacitor 9stage from 2KVAR to 20 KVAR
1. stage -2 KVAR
2. stage -3 KVAR
3. stage -5 KVAR
4. stage -10 KVAR
5. stage -10 KVAR
6. stage -15 KVAR
7. stage -15 KVAR
8. stage -20 KVAR
9. stage -20 KVAR | 1 | No | 4,68,000 ₹4.7 L | 4,95,000 ₹5.0 L |
| 5.0110. stage -25 KVAR 11. stage -25 KVAR 12. stage -50 KVAR Bus bar: 2 run of 50mm x 6mm tinned copper Metering : 1-500A Ammeter with CT coil 2) 0-500V voltmeter 3) Advanced micro controller based intelligent power factor controller with self diagnostic sensing and digital network analysis with software for momentary and saving parameter using a suitable multi function meter. Indication: R,Y,B The panel should be coated with Epoxy based painting and the whole assembly fixed in suitable cubical panel grouted in floor with connection complete (SR M - 2467) | |||||
Tender Value
₹1.1 Cr
EMD Value
₹65,000
Closing Date
21 Jan 2026, 3:00 pmClosed
The Superintending Engineer PWD
Buildings C and M Circle Salem
Improvement of Power Panel Vacuum Circuit Breaker and 1000KVA Transformer with Power Cables, MV Panel in Government Dharmapuri Medical College and Hospital at Dharmapuri in Dharmapuri District
2026_PWD_642308_1
41/1/2025-26
Open Tender
Electrical Works
180 days
Dharmapuri
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹65,000
26 Feb 2026
13 Jan 2026
21 Jan 2026
13 Jan 2026
21 Jan 2026
13 Jan 2026
Supply, erection, testing and commissioning of 1000 KVA, 11KV, 433V, HV - Delta, LV Star off load tap changing, copper wound, outdoor type with off circuit (level - 1 ) As per IS 1180 Oil Cooled Distribution Transformer as per IS 1180(Level I) ON AN cooled, confirming to relevant IS 1180 / IEC 60076, Level-II Class A Insulation and mounted on 300 x 90 x 6mm base channel bolted to a suitable RCC plinth of height 5' and RCC foundation to a depth of 2' with reinforcement by suitable MS rods 150Kg / m3 capable of bearing 2 ton weight and connected works fitted with the following: 1) HT Cable End box suitable for connection of 11KV 3c x 300 sq.mm HT cables & LT Cable end box suitable for 2runs x 3c x 300 Sqmm cable 2) Bucholz relay with shut off valve, alarm and trip contacts. 3) Dehydrating silica gel breather. 4) Conservator with oil filling pipe, cap and drain plug valve.
5) Tank drain cum bottom filter valve with plug. 6) 4 Nos. plain rollers uni and bi-directional under base channels with skid.7) Dial type thermometer with pocket to measure oil temperature stem type. 8) Tank top filter valve with plug. 9) Explosion vent with diaphragm. 10) Oil level gauge with marking. 11) Two body earthing terminal and additional neutral bushings for solid earthing. 12 Rating and terminal marking diagram plate. 13) Lifting hooks/ Lifting eyes/ Jacking pad to facilitate easy movement of Transformer to ground level, cover lifting lugs. 14) Off load hand operated tap changing switch at standby height from ground level. 15) Tapping on primary winding for voltage variation +5% to -5% in steps of 2.5%. 16) Welded and detachable radiators. 17) Air release device. 18) The transformer should be supplied with first filling of oil as per IS 335 with high dielectric strength, BDV and flash point. 19) Monogram plate. 20) Shut off valve for surge relay 21) Oil surge relay 22) All removable covers shall be provided with weather proof hot oil resistant, resistance gaskets to prevent leakage of water into core, and oil from the tank with low no load loss 1100W and full load loss 6400W, impendence 5% with temperature rise oil / winding 50° - 55°C(Make: CREL / Rowsons/SPS or its equivalent) (SR) (M-1940)
5) PROTECTION Numerical Non directional IDMT combined 30/C +1 E/F relay with highset. Highspeed / Master trip relay (EMR151) Transformer fault annuciation relay. INDICATION LAMP 6) Phase Indicating Lamps RY and B (Incoming 3 Nos.), Breaker ON indication (Red- 5nos), Breaker OFF indication (Green- 5nos), Breaker TRIP indication (Orange - 5nos), Trip circuit Healthy indication (Yellow - 5nos) 7) Control wiring 8) 630Amps Copper Bus Bar PVC sleeved and required panel copper earthing. 9) Control Switch TNC (Incoming 1 no. outgoing 3Nos) 10) Trip Circuit Healthy Push Button (Incoming 1 No. outgoing 3Nos) 11) Common for Switch gear, MCB’s for AC / DC Control Heater ON/OFF switch with space Heater and thermostat single phase Switch socket, cubicle illumination lamp, Disconnecting type terminal Block etc. MS sheet enclosure for Indoor Installation powder Coated with paint shade Siemens Grey. Provision through Bottom entry to receive Incoming or out going cable excluding cable glands and cable terminal kit. (Make : Safevolt / Mega win electro technical / Sriwin electric ) (SOR)
Interconnection of proposed single panel 630A VCB to the existing three panel VCB as one of the outgoing feeders with necessary busbar arrangements with proper interconnections in complete. (Quotation)
Design, Supply, erection, testing and commissioning of 1250A draw out type floor mounted MV cubical bus bar chamber dust and vermin proof and accommodating the following SDF’s and 1 No. ACB as Incomer units and 1 No 1250A draw out type ACB with the following items of work complete to satisfy the latest IE rules and CEIG guidelines. Supply and fixing of suitable bus bar chamber made up of 16SWG MS sheet steel with 2Nos. of 4” X 1/4” tinned copper bus bar for 3 phases and neutral and 1Nos. of earthing bus of size 1” X 1/8 tinned copper bus on suitable bus bar insulator (Epoxy insulator) with maximum creepage distance and supported on MS Base channel frame work of size 4”X 2”X ¼”–1Set Incoming 1)Supply and fixing of 1 No. 1250A basic rating 4 pole 433V LT ACB confirming to IS 13947–2 IEC 60947–2 with making capacity of 50 KA and breaking capacity of 690V AC with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing release forover current protection UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mould base for each pole for easy maintenance all relevant protection safety accessories as per CEIG, IE rules inforce with inter connection and terminations as required in specification.
Outgoing: 1)Supply and fixing of 1 No. 800A basic rating 4 pole 433V LT ACB confirming to IS 13947–2 IEC 60947–2 with making capacity of 50 KA and breaking capacity of 690V AC with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing release forover current protection UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mould base for each pole for easy maintenance all relevant protection safety accessories as per CEIG, IE rules inforce with inter connection and terminations as required in specification.2)Supply and fixing of 4 Nos. 630A 4 pole switch disconnector fuse unit in sheet steel enclosure. 3)Supply and fixing of 4 Nos. 400A 4 pole switch disconnector fuse unit in sheet steel enclosure. 4)Supply and fixing of 4 Nos. 250A 4 pole switch disconnector fuse unit in sheet steel enclosure. The bus bar chamber will consist of 4nos of suitable size of copper flat for phase and neutral buses on epoxy moulded bus insulators at proper and sufficient spacing between the buses as per IE rules. This bus bar chamber should be segregated from the adjacent chambers by providing hylem sheet of suitable thickness as partisans suitable size of copper flats should be provided all round the panel for earth bus.
Design, supply, erection of 200KVAR, 12 stage switching, sequence automatic power factor correction wall mounting stand vermin proof cubical panel board made of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting capacitor chamber relay with metering chamber and compartmentalised out going feeders with suitable capacity MCCB with panel board with provision for louvers and cooling fan for proper ventilation to manage heat load incoming - 630A FP MCCB with rotary handle. Outgoing : 12 stage capacitor bank Contactors : Bharatia Cuttler Hammer/ L&T Heavy Duty contactors. Relays : World class solid state relays with TM2 technology as an option. Capacitor MPP capacitor 9stage from 2KVAR to 20 KVAR 1. stage -2 KVAR 2. stage -3 KVAR 3. stage -5 KVAR 4. stage -10 KVAR 5. stage -10 KVAR 6. stage -15 KVAR 7. stage -15 KVAR 8. stage -20 KVAR 9. stage -20 KVAR
10. stage -25 KVAR 11. stage -25 KVAR 12. stage -50 KVAR Bus bar: 2 run of 50mm x 6mm tinned copper Metering : 1-500A Ammeter with CT coil 2) 0-500V voltmeter 3) Advanced micro controller based intelligent power factor controller with self diagnostic sensing and digital network analysis with software for momentary and saving parameter using a suitable multi function meter. Indication: R,Y,B The panel should be coated with Epoxy based painting and the whole assembly fixed in suitable cubical panel grouted in floor with connection complete (SR M - 2467)
Design, supply, erection of 100KVAR, 9 stage switching, sequence automatic power factor correction wall mounting stand vermin proof cubical panel board made of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting capacitor chamber relay with metering chamber and compartmentalised out going feeders with suitable capacity MCCB with panel board with provision for louvers and cooling fan for proper ventilation to manage heat load incoming - 630A FP MCCB with rotary handle. Outgoing : 9 stage capacitor bank Contactors : Bharatia Cuttler Hammer/ L&T Heavy Duty contactors. Relays : World class solid state relays with TM2 technology as an option. Capacitor MPP capacitor 9stage from 2KVAR to 20 KVAR 1. stage -2 KVAR 2. stage -3 KVAR 3. stage -5 KVAR 4. stage -10 KVAR 5. stage -10 KVAR 6. stage -15 KVAR 7. stage -15 KVAR 8. stage -20 KVAR 9 stage - 20 KVAR
Bus bar: 2 run of 33mm x 6mm tinned copper Metering : 1-500A Ammeter with CT coil 2) 0-500V voltmeter 3) Advanced micro controller based intelligent power factor controller with self diagnostic sensing and digital network analysis with software for momentary and saving parameter using a suitable multi function meter. Indication: R,Y,B The panel should be coated with Epoxy based painting and the whole assembly fixed in suitable cubical panel grouted in floor with connection complete (SR M - 2465)
Preparation of site plan physical layout, electrical line schematic diagram in 10 sets getting drawing approval from CEIG, preparation of completion report, rectification report and arranging CEIG inspection and obtaining safety certificate preparation of 1 set of approved drawing and a copy of safety certificate in a neat frame work to be fixed in alternation of CEIG.
Suppy, Fabrication and Installation of 11KV Bus Duct 1600A electrical conduit safely distribute high voltage electricity within a power system. (Quotation) (For 1000KVA Transformer to MV Panel)
Supply and laying of 11KV 2R 3C x 300 sq.mm HT Three Core Power Cables - Aluminium Conductor XLPE Insulated cable in a trench to be excavated at a depth of 1.60 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (DATA-2) (For HT to VCB to Transformer)
Supply and clamping of 11KV 2R 3C x 300 sq.mm HT Three Core Power Cables Aluminium Conductor, XLPE Insulated cable on post or on wall with MS clamps. (DATA-3)
Supply and providing cable suitable 11KV 3 core 300 sqmm XLPE HT UG cable with necessary outdoor type heat shrinkable Termination kit and accessories with termination complete. (DATA-4)
Supply and providing cable suitable 11KV 3 core 300 sqmm XLPE HT UG cable with necessary Indoor type heat shrinkable Termination kit and accessories with termination complete. (DATA-5)
Supply and clamping of 3½ x 120 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (SD-210) (For APFC Panel -3 Nos.)
Supply and fixing of brass cable gland for 3½ x 120 sq.mm PVC armoured LTUG cable, with earth connection. (SD-169)
Supply and providing cable end termination of 3½ x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. (SD-228)
Supply and clamping of 3½ x 185 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (SD-212) (For Transformer Separation)
Supply and fixing of brass cable gland for 3½ x 185 sq.mm PVC armoured LTUG cable, with earth connection. (SD-171)
Supply and providing cable end termination of 3½ x 185 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. (SD-230)
Supply and laying of 3½ x 300 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75metre putting 0.15mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. (SD-191) (From 500ward main panel to OP block old panel)
Supply and clamping of 3½ x 300 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (SD-214)
Supply and fixing of brass cable gland for 3½ x 300 sq.mm PVC armoured LTUG cable, with earth connection. (SD-173)
Supply and providing cable end termination of 3½ x 300 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. (DATA-6)
Supply and clamping of 3R 3½ x 400 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (DATA-7) (From New MV Panel to Old 630A ACB & From 1250A ACB to Existing ACB Panel)
Supply and fixing of brass cable gland for 3½ x 400 sq.mm PVC armoured LTUG cable, with earth connection. (SD-174)
Supply and providing cable end termination of 3½ x 400 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. (DATA-8)
Supply and fixing of 2m x 1m rubber mat (5nos) suitable for 11KV installation confirming to IS. (SR M 1976)
Supply and fixing of 3mm MS chequer plate for trench in panel room. (Quotation)
Supply and fixing of 6mm MS chequer plate for trench in HT room. (Quotation)
Supply and Run of 1 of No.8 SWG copper wire for earth connection. (SD-371)
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. (SD-76)
Earthing as per the ISI specification with an earth electrode of 2.1 mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. (SD-221)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_769501.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
Powerpanel1000KVATransformerGHdharmapurielectricalGeneralALLcondition.pdf
Tender Documents • 0.51 MB
BOQ_769501.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid