Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.5 LAccepted-AOC 1 367 SIVAN KOVIL STREET THONDAMATHURAI POST VEPPANTHATTAI TALUK PERAMBALUR DISTRICT | PERAMBALUR | TAMIL NADU | 621101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹62.4 L+₹4.4 L (7.50%)Rejected-AOC 17 A SHYAMA JI PURAM I I T SOCIETY IIT KALYANPUR KANPUR UTTAR PRADESH 208016 | KANPUR NAGAR | UTTAR PRADESH | 208016 | L2 | Rejected-AOC L2 |
Tender Value
₹55.6 L
EMD Value
₹37,800
Closing Date
17 Aug 2023, 11:30 amClosed
Chief Engineer
Office of Chief Engineer, Sardar Patel Road, Dote Campus, Chennai 25
Construction of Additional Class room building over EVVS building first floor in Government Arts College, Ariyalur
2023_HE_351861_1
GACAriyalur_2023
Open Tender
Civil Works - Buildings
Lump-sum
180 days
Ariyalur
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹37,800
Yes
30 Oct 2023
28 Jul 2023
18 Aug 2023
29 Jul 2023
17 Aug 2023
29 Jul 2023
Amount
Dismantling, removing and carefully stacking Dummy column etc., complete complying with standard specification and as directed by the departmental officer.
Dismantling Clearing away and carefully stacking materials useful for reuse for any thickness of brick / stone masonary in cement mortar walls under 3m high etc., complete complying with standard specification and as directed by the departmental officer.
Dismantling clearing away and carefully stacking materials useful for reuse for any thickness of wethering course and pressed tiles of one course roof finish in cement mortar and stacking carefully away from the site for reuse etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
Plain surfaces such as RCC floor slab, roof slab, rectangular, square Tee or Ell beam, lintel, bed block staircase waist slab, landing slab landing beam, portico beam, portico slab etc.,
For plane surfaces such as rectangular or square RCC Columns, sunshades, top and bottom slab of RCC boxing etc.,
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
For every 1m height
Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance using with IS:456-2000, 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
For Superstructure in First floor
For Superstructure in Second floor
Supplying fabricating and placing in position of steel reinforcement using MS (or) RTS rods for all RCC item of works including cost of steel and binding wire in all floors etc. complete complying with standard specification and as directed by the departmental officers. (The contractor will have to make his own arrangements for the supply of M.S.plain rod / RTS rod and black binding wire).
Brick work in cement mortar 1:6 (one cement and six M sand) using Fly Ash bricks of size 230×110×70mm including curing etc., complete complying with standard specification and as directed by the department officers. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost).
For Superstructure in First floor
For Superstructure in Second floor
Weathering course using best quality of broken brick jelly of 20mm gauge in pure slacked lime (no sand to be added) the proportion of brick jelly to lime being 32:12.5 Cft. by volume and laid over the RCC roof slab in a single layer and consolidated to the required design and finished thickness and slope by beating the concrete with wooden beater of approved pattern and keeping the surface constantly wet by sprinkling lime jaggery water etc., complete complying with standard specification and as directed by the departmental officers. For Superstructure in First floor
Finishing the top of roof with one course of Machine pressed tiles of size 23×23×2cm of approved quality laid in cement mortar 1:3 (One cement and three M-sand) 12mm thick mixed with water proofing compound (confirming to Indian standard specification) 2% by weight of cement used and pointed with the same mortar including mixing of red oxide and water proofing compound etc., complete complying with standard specification and as directed by the departmental officers.
Paving the floor with Double charged vitrified tiles (like Marbonite or equivalent) of approved quality and colour of size 600 x 600x 8 mm thickness in all floors over a base layer of cement mortar 1:3 (one cement and three M sand) 20mm thick and pointing with white cement using 0.30kg/m2 including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification and as directed by the Departmental officers. (The tiles should be got approved by the Departmental officers before use on works).
Special ceiling plastering in all floors and finishing the exposed surface of RCC items of work such as slab, beam, sunshade, facia, canopy slab, staircase waist slab, landing slab etc., with cement mortar 1:3 (One cement and three P. sand) 10mm thick including hacking the surfaces and providing cement mortar nosing, beading for sunshade, staircase, step, landing slab etc., including neat finishing and curing etc., complete complying with standard specification and as directed by the departmental officers.
Plastering with cement mortar 1:5 (one cement and five P. sand) 12mm thick in all floors using P sand including neat finishing, curing, etc., complete complying with standard specification and as directed by the department officers.
Supplying and fixing in position best approved of ISI quality of following diameter PVC rain water down fall pipes having a working pressure of 4 kg / sq.cm including cost of necessary PVC shoe, PVC bend, C.I. gratings of required dia. and special clamps, brass screws, nails etc., and fixing of cast iron gratings at juction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cost of removable iron grating. The PVC pipe shall be fixed on wall with special type of clamps. Special type "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0M pipe length complying with standard specification.
110mm dia PVC pipe
Supplying and fixing inposition C.R.C.A Pressed steel box section 18 guage or 1.25mm thick for door frames of section size 105x60x1.25mm thick with necessary rebate of size 35x15mm for housing door conforming to B.I.S. specification frames shall be fabricated according to the door size with joints properly welded and grinded. Stiffeners with 25x3mm M.S. Flat shall be provided around the frame at 60cm intervals. The cost of shall also include for providing 3 Nos., of M.S. clamps with 25x3 flats each on either sides of door frame. Providing bottom tie, providing necessary holes for receiving tower bolts with stiffners on inner side providing holes in the frame for fixing the required number of hinges for shutters properly welded to the frames, finishing the door with one coat of good quality red oxide primer, with cement concrete 1:2:4 (One cement, two sand and four aggregate) using 20mm gauge hard broken granite stone jelly including cost of all materials, frabrication and conveyance to the site and fixing inposition with necessary scaffolding etc.
Supplying and fixing in position of 35 mm thick solid core flush door shutters Double leaf with TW ply on both sides and withbTW lipping of size 35 x 12mm on all edges with necessary adhesive and CP screws. Alu. Butt hinges ( 3 nos. 125 x 16 mm size) , Alu. Aldrop 1 No. 250 x 16 mm Size. Alu.Tower bolt 1No. 250 x 12mm size, alu. Tower bolt, 1No. 200 x 12mm size , D type alu. Handle 2 Nos. 1No of 200 mm length., alu. door stopper with rubber bush 1 No shall be provided, as directed by the departmental officers etc, complete.
Manufacturing, Supplying and Fixing in position of M.S steel window with following specifications. The outer frame of window made out "Z" section (F7D) of size 33x25x3mm at 1.419 Kg/m and mullion of "J" section (F4B) of size 45x25x3mm at 2.28 Kg/m. Shutter made out of (F7D) section of size 33x22x3mm at 1.419 Kg/m. Each openable shutter should not be exceeded a width 600mm to enable separate operations and easy maintenance. 2Nos. of sturdy hinges and one number of handle cum latch of special type make with 18x5 MS flat are revetted to the shutters of an appropriate height in each window shutter. Suitable opening is left for its easy operation. A stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle.
Each shutter having an adjustable window stay made out of 18mmx5mm at 0.70 kg/m MS flat of length 320mm with free adjustable positions. A matching peg is provided in the outer frame of the window, at suitable place, 4Nos of holdfasts of 200mm length MS angle 40x40x6mm the ends are welded to the outer frame of the window, 18 mmx 5 mm at 0.70 kg/m MS flat is welded to the shutter at two places, equal distance from each other from top and bottom of the shutter. 18 gauge cold rolled sheet of superior quality is laid as panel in the shutter frames and welded intact. Stiffeners with 18x5mm at 0.70 kg/m MS flat of suitable length welded diagonally to all four corners of each openable shutter to hold the CR sheet in position firmly. MS square bars of 12mm size is welded to the inner face of the window at equal intervals not exceeding 100mm edge to edge between them. All members are painted with one coat of anticorrosive red oxide primer as directed by the departmental officers. All sections used should confirm to IS 7542 / 1990. The rate includes cost of all materials, labour charges, transportation to taxes and other incidental charges etc. complete. Three leaves
Supplying and fixing of special type Terra Cotta Jally of size 20x20x8cm of approved pattern including pointing neat finishing and labour charges for fixing the jally in position etc., complete complying with standard specification and as directed by the departmental officer
Supplying and fixing MS grills to doors, windows and ventilators etc. using necessary MS flats (or) square rods for inner members and outer members which should be fixed to window frames as directed and design given by the departmental officers inclusive of cost of providing one coat of best quality red oxide primer etc., complete complying with standard specification and as directed by the departmental officers .
Painting the walls two coats with best Oil bound distemper of approved quality (to be approved by the Executive Engineer before use on works) over one coat of primer for newly plastered wall including preparation of surface and finishing neatly including cost of all materials, brushes, scaffolding charges etc., complete complying with standard specification and as directed by the departmental officers.
Painting the exterior walls surface two coats of best and approved first quality and colour of Exterior emulsion paint in all floors over one coat of primer including preparation of surface, wall putty two coats with good quality including cost of wall putty , emmary sheet, plates, etc. and including labour charges for rubbing the wall scrapping putty pasting works and making good smooth surface and finishing neatly etc., . complying with standard specification and as directed by the departmental officers etc. complete. ( The make, quality and colour of paint should be got approved by the departmental officer before use of work)
Painting the new iron work with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat and including cost of painting materials, brushes, putty, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer. (The quality and colour of paint should be got approved by the departmental officer before use on work).
Painting the new wood work two coats with best approved first quality and colour of synthetic enamel paint over a priming coat of approved quality in all floors including cost of paint, labour and other materials like brushes, putty and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officers. (The make quality and colour of paint should be got approved by the departmental officer before use on work).
Supplying and installation of Ceramic Steel chalk writing board with the following specification. The 2mm GI Sheet is placed with wall side over the GI sheet necessary adhesive is spreaded and fixed the 9mm MDF board on the GI sheet 0.40mm thick ceramic steel chalk board is provided over the MDF board and the whole arrangements are fixed to the frame using heavy anodized Aluminium section and Chromium plated provided in the corners. The whole arrangement are fixed to the wall using wooden plugs and screws etc., The rate includes all above materials, labour charges and taxes etc., complete complying with standard specification and as directed by the departmental officers.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Sub Total
Krishna and Co
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .