Replacement of ELB, broken due to accident by road vehicle at LC gate over Moradabad Division.
SNT-Broken-ELB-2025-26
SNT-Broken-ELB-2025-26
Open
Works - General
12 Months
Moradabad, Uttar Pradesh
₹0
₹1.8 L
21 Jul 2026
21 Jul 2026
29 Jul 2026
01- Replacement of ELB, broken due to accident by road vehicle at LC
Supply of Electrically Operated Lifting Barrier Assembly Complete with drive mechanism, motor etc.with push button type contol panel, boom locking arrangement, crank handle complete without hand generator as per RDSO specification No.RDSO/SPN/208/ 2012 Ver. 2.0 or Latest. Both the Booms Shall be as per RDSO Drg.No.RDSO/ S11600 of GI Boom in Octagonal shape 01 with temporing cross section with telescope structure. The total length of the Boom shall be 9.76m (Maximum 4 sections joined by nut and bolts). Operating voltage of the gate should be 110 V AC. Tool kit consisting of standard size of wrench/spanner and Allen Keys should also be Supplied with each set (02nos) of ELB. Note: Drg.No, RDSO/S-11600 inclusive of 2 stop boards, boom light boxes, MS counter weights, 2 Nos. boom support for resting boom, boom locking assembly, control panel. Inspection Authority: RDSO Technical Specification: As per technical specification provided in Part III of Tender Document
Installation wiring & commissioning of electrically operated lifting barrier as per standard practice Inspection Authority: Site Engineer (OEM PCCL to be submitted) Technical Specification: As per technical specification provided in Part III of Tender Document
Supply of Lifting barrier booms of 32 fit suitable for electric lifting barrier gates from 03 RDSO approved firm as per RDSO specifications RDSO/SPN/208/2012Ver.2 or latest. Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document
Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No.(NR/S&T/CON/1. 1/97-A) so as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable route plan in all type of soil, It also includes clearance of routes of trees & bushes. Lesser depth due to site condition shall be paid proportionately only after taking permission from atleast JAG officer. Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Boring & Trenchless cabling along with supply & insertion of self lubricated HDPE pipe 05 as per IS 4984:2016 of 110 mm outer dia with 6mm wall thickness in the bore for laying of Signalling / Telecom /Power cable under track/road/culvert at the depth of 1.5mtrs etc.cable laying covered seperately. Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Laying of signalling/Telecom/power cables of different sizes as per drg. No. (NR/S&T/CON/1.1/97) and as per cable route plan approved by Railways and meggering of cable 06 before and after its laying of all type of outdoor cables. Meggering to be done for each drum seprately. Meggering sheets to be supplied and filled up by contractor and submitted to railways. Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. 07 (NR/S&T/CON/1.1/97) as per instructions of the site Engineer. Inspection Authority: Supply: Consignee, Installation: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document Square
Reflective Tape Yellow :- Highlighter grade retro reflective tape is made of non 08 metelised polycarbonate micro primatice visible from 1000 meters highly durable ASI 90 specified reflection value will not detroinate as sure clean application and endures protection against seepage and dirt are to confirm compliance to ASI 90 size per four feet width in roll . Inspection Authority: Consignee Technical Specification: As per technical specification provided in Part III of Tender Document
Dismantling of lifting barrier/gate leaves/ELB complete set alongwith winch, wire 09 rope, boom locking arrangements.All dismantelled material to be transported and stacked in the store of SSE/Sig of MB div. Inspection Authority: Site Engineer Technical Specification: As per technical specification provided in Part III of Tender Document
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
brokenfinal_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].