Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | ₹19.5 L Quoted ₹20.8 L | L1 | Accepted-AOC being lowest |
| 2 | L2₹23.3 L+₹2.5 L (12.1%)Rejected-Finance RZ 40 PALAM VIHAR DWARKA SECTOR 6 NEW DELHI 75 | NEW DELHI | DELHI | 75 | ₹23.3 L+₹2.5 L (12.1%) | L2 | Rejected-Finance BEING NOT LOWEST |
| 3 | L3₹24.0 L+₹3.2 L (15.4%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹24.0 L+₹3.2 L (15.4%) | L3 | Rejected-Finance BEING NOT LOWEST |
| 4 | L4₹25.3 L+₹4.5 L (21.8%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | ₹25.3 L+₹4.5 L (21.8%) | L4 | Rejected-Finance BEING NOT LOWEST |
| 5 | L5₹25.8 L+₹5.0 L (24.3%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | ₹25.8 L+₹5.0 L (24.3%) | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹35.1 L
EMD Value
₹70,300
Closing Date
2 Jul 2022, 6:00 pmClosed
ARJUN PATRO,IDSE
GE UTILITY ELECTRIC SUPPLY,DELHI CANTT
REPLACEMENT OF DAMAGED LT STREET LIGHT POLE , PAINTING, REPLACEMENT OF JUNCTION BOXES, LT PANELS , MCCB AND ACCEESSORIES OF IHQ CAMP ARMY VIKRAM VIHAR , YOGENDRA VIHAR, VRC,OTM ACCN , ANUJ VIHAR, CAMS DGIS WARDEC OF SHANKAR VIHAR AREA UNDER AGE U
2022_MES_526190_1
GE ELECT/D-21/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE UTILITY ELECTRIC SUPPLY
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE UTILITY ELECTRIC SUPPLY
₹70,300
Yes
4 Oct 2022
7 Jun 2022
4 Jul 2022
8 Jun 2022
2 Jul 2022
20 Jun 2022
Amount
M & L for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel/Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 50 m as directed.
Supply only fuse wire of rating 20Amps/40Amps/60 Amps complete all as specified and as directed
Material and labour for PCC 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate) for foundation, filling and mass concret etc complete all as specified and directed including demolition of old unserviceable PCC complete all as specified and as directed .
S&F in replacement Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed
M&L Brick work with sub-class 'B' bricks, straight or curved on plane exc 6 m mean radius, built in cement mortar 1:6 complete as specified and directed including demolition of old unserviceable brick work complete all as specified and as directed .
Material and labour for coarse aggregate filling using stone gravels, rounded, of size n exc. 40 mm , in the area covered by street light tubular pole structures complete all as specified and directed.
M & L for PCC 1:3:6 type B0 using 12.5 mm graded stone aggregate for coping of pole complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate for pole foundation all as specified and directed.
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black radium strips upto height of 1.5 mtr above from ground level complete all as specified and directed.
Supply & fixing in replacement of SMC Junction box for street light having side hinged, outside dimention 333x233x120mm and inside dimention 300x200x105mm including 4 Nos aluminium bus bar of 40 Amps rating and 1 No 5 A MCB SP connecting of existing LT power cable complete all as directed
Supply and fixing in replacement of Automatic Light Timer switch with Nature switch Cat No. SWADEEP-02EC12KW3P, infra ray sensor with pre sawn switching off timer, 4-8 hrs, of Maximum load capacity of 4KW per phase. Degree of protection conforms to IP 65 complete all as specified and directed.
Supply & fixing in replacement of quick sensor QS-301 water proof sensor 220V auto day/Night ON and OFF photo cell , LDR Sensor of capacity 6A for fixing in places of defective timers of street light control panels complete all as specified and directed.
Supply and making in replacement new LT 1100 V end termination with suitable size of aluminium lugs duly crimped for LT 3 ½ core armoured aluminium conductor cable after isolating supply to transformer/LT panel and disconnecting brunt/fault cable from the bunch of cables in trenches, galleries, removing cable loop, opening the cable blank and connecting back after end terminals, testing and commissioning for following sizes all as specified and as directed
35 Sqmm to 120 Sqmm
185 Sqmm to 240 Sqmm
300 Sqmm to 500 Sqmm
Supply, Laying, connecting, testing and commissioning in replacement ( including taking out existing cable) LT cable of PVC sheathed XLPE cable armoured aluminium conductor 1100 V graded after taking out/down old existing unserviceable from trenches / ducks/ road crossing and poles complete all as specified and directed of following size
3.5 core, 50 sqmm.
3.5 core, 35 sqmm.
3.5 core, 25 sqmm.
4 core, 16 sqmm.
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out all as specified and directed by engineer –in-charge.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point .
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by engr –in-charge, Note : Measurement shall be taken after punning down.
S&Laying in replacement sub class B bricks having minimum compressive strenth 75 Kg/sqm ( 250x115x75mm) laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Supply and lay in replacement unreinforced precast concrete cable covers class LV Type -1 with peak size 250 x 150 x 40 mm. compete all as specified and directed
Material and Labour only for repairing and rectification of faults in 16 / 32 mtr High mast lights by checking the control panel Trailing Cables, timers. contactors and replacing the defective electrical parts, Servicing and greasing to the winch gear wheel mechanisum for electrical and manual operation of the carrier along with replacement of dog clamps of the wire rope and replacment of the existing old unserviceable light fittings with controll gears with new LED light fitiings complete and fixing of the control panel for desired operation all as specified anddirected by the Eng-in-Charge Note :(I) Necessary Digital timers /Power contactors and LED light Fittings shall be measured under Relevant Items. (II) Necessary arrangements for Safety and T&P repairs shall be under taken by contractor
Taking out old street light fittings and supply and fixing of new generation energy saving and environment friendly long life verasalite pressure die- cast aluminium IP 65 road way luminare with high power LEDs of 90 Watts capacity as light source and exclusively designed for poly carbonate cover with electronic drive.along with 1.5mtr bend pipe necessary wiring and clamps for fixing on all as specified and directed
Taking out old street light fittings and supply and fixing of new generation energy saving and environment friendly long life verasalite pressure die- cast aluminium IP 65 road way luminare with high power LEDs of 60 Watts capacity as light source and exclusively designed for poly carbonate cover with electronic drive.along with 1.5mtr bend pipe necessary wiring and clamps for fixing on all as specified and directed
Supply and fixingin replacement of of new generation energy saving& enviroment friendly aluminium pressure die cast high power LED flood light luminare of wattage 120 Watts of IP66,class I portection integral driver operation at 170-270VAC 50Hz supply inclding , brackets for fixing on the pole/buildings/walls complete all as specified and directed.
M&L in replacement for service cable 6 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular all as required or directed.
Taking out old damage LT pole and Supplying, Errection & Fixing Steel Tubular swan neck pole ,(09 metres long) Painting of Poles with one coat of red oxide primer and one coat of aluminum paint before fixing and one coat of aluminum paint after fixing. The complete embedded portion shall be painted with two coats of black bituminus paint complete with cast iron base plate all as specified. (Note : Excavation earth work ,PCC may be paid separatly of respective items.)
Cutting of road /Hard standing to a size of 30 cm in width and not exceeding 90cm in depth for laying of protection pipe /cable including spreading, leveling, watering and well ramming in layers and providing PCC in 1:2:4 type B1 using 20mm graded stone aggregate, for the top 100mm layer, complete all as specified and directed.
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified of size :-
50 mm dia
80 mm dia
M&L for replacement of Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Takin out old unservieable old PCC pole of size 9 to 11 meter at various locations as specified and directed by engr-in-charge
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).
(a) Incoming :- (i) Incomer of the panel having MCCB 4 pole , 350 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 400 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set (b) Outgoing :-(i) MCCB 4 pole 415 V breaking cap 16 KA , current rating 63 Amps. - 09 Nos (ii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint .(iv) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vii) Indicating Lamps R Y B , LED type01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).
(a) Incoming :- (i) Incomer of the panel having MCCB 4 pole , 350 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 400 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set (b) Outgoing :- (i) MCCB 4 pole 415 V breaking cap 16 KA , current rating 63 Amps. - 07 Nos (ii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iv) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vi) multifunctioning meter with communication ports RS 485/232 5 display class-1 - 01 set (vii) Indicating Lamps R Y B , LED type01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).
(a) Incoming :- (i) MCCB 4 pole 415 V breaking cap 36 KA , current rating 200 Amps. - 01 Nos, with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 250 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set (b) Outgoing :- (i) MCCB 4 pole 415 V breaking cap 16 KA , current rating 63 Amps. - 04Nos (ii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iv) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vi) multifunctioning meter with communication ports RS 485/232 5 display class-1 - 01 set (vii) Indicating Lamps R Y B , LED type01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).
(a) Incoming :- (i) MCCB 4 pole 415 V breaking cap 36 KA , current rating 200 Amps. - 01 Nos, with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 250 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No ( iv) Indicating Lamps : 01 set (b) Outgoing :-(i) MCCB 4 pole 415 V breaking cap 16 KA , current rating 125 Amps. - 02 Nos (ii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iv) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vi) multifunctioning meter with communication ports RS 485/232 5 display class-1 - 01 set (vii) Indicating Lamps R Y B , LED type01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).
(a) Incoming :- (i) MCCB 4 pole 415 V breaking cap 16 KA , current rating 125 Amps. - 01 Nos, with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 200 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set (b) Outgoing :- (i) MCCB 4 pole 415 V breaking cap 16 KA , current rating 100 Amps. - 02 Nos (ii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iv) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (v) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vi) multifunctioning meter with communication ports RS 485/232 5 display class-1 - 01 set (vii) Indicating Lamps R Y B , LED type01 set
Taking out old rusted unserviceable LT panel Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The outer enclosure shall be made of 3.15 mm thick SS 316 sheet and inner compartment should be 2 mm. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm).
(a) Incoming :- (i) MCCB 4 pole 415 V breaking cap 36 KA , current rating 200 Amps. - 01 Nos, with microprocessor release - 01 Nos , Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters, Total Harmonic Distortion and Maximum Demand Indication etc and shall have RS-485 port for communication on Modbus protocol – 01 No, CTs ratio 400/5 A, Class 1, ISI marked -01 sets of three, Indicating lamp- 01 set of three & Aluminium bus bar of rating 250 Amp, 4 pole , mounted on SMC insulator- set of four. (ii) Digital type Volt meter 0-500 volt - 01 Set (iii) Digital type Amp meter with CT's - 01 No (iv) Indicating Lamps : 01 set (b) Outgoing :-(i) MCCB 4 pole 415 V breaking cap 16 KA , current rating 100 Amps. - 03 Nos (ii) MCCB 4 pole 415 V breaking cap 36 KA , current rating 63 Amps. - 01 Nos (iii) All incoming & outgoing feeders shall be connected by cable through suitable size of gland plate/glands. (iv) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint .(v) All incoming & outgoing feeders shall be connected by cable through suitable size gland plate/glands. (vi) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (vii) multifunctioning meter with communication ports RS 485/232 5 display class-1 - 01 set (viii) Indicating Lamps R Y B , LED type01 set
M&L in replacment of Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron 32x6mm GI strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip and protection pipe upto 7.5 meter beyond the earth plates electrode.
NOTE :-(i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
BUSINESS TEK INDIA
mayur enterprises
M/s Adhikari construction co.
MV Engineers And Contractors
Vijay Electricals
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .