Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC | ₹1.1 L Quoted ₹11.5 L | L1 | Accepted-AOC 110016.00 |
| 2 | L2₹13.0 L+₹1.4 L (12.5%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹13.0 L+₹1.4 L (12.5%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹15.6 L+₹4.1 L (35.5%)Rejected-Finance | ₹15.6 L+₹4.1 L (35.5%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹16.6 L+₹5.1 L (44.2%)Rejected-Finance | ₹16.6 L+₹5.1 L (44.2%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹17.5 L+₹5.9 L (51.3%)Rejected-Finance | ₹17.5 L+₹5.9 L (51.3%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
24 Jun 2021, 6:00 pmClosed
GE (AF) BHISIANA
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (AF) BHISIANA, BATHINDA - 151201
Comprehensive Maint of certain E/M Works in Technical Area at AF Stn Bhisiana
2021_MES_446207_1
GE/BHI-17/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) BHISIANA
Please Refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) BHISIANA
₹50,000
Yes
11 Aug 2021
27 May 2021
26 Jun 2021
27 May 2021
24 Jun 2021
10 Jun 2021
28 May 2021 - 7 Jun 2021
Amount
Taking down carefully copper/Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc all as directed.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
Concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade drawn through and including non metallic rigid PVC conduit, medium grade minimum 19mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings, switches, sockets outlets, regulators etc complete including provisining of 1.0 sqmm PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following:- Note : For Modular fittings, frame, cover and flush boxes measured and paid relavant item of Sch-'A', Part-I.
One light/fan/bell point controlled by one switch 6 Amp one way.
One 3 pin switch socket combination 6 Amp on the independent board.
One 3 pin switch socket combination on same board with other switches.
All as described above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 Amp multi purpose socket combination point on independent board.
M&L switch piano flush type single pole, one way 6 Amp.
M&L switch piano flush type single pole, one way 15 Amp.
M&L socket outlet piano flush type 2 in 1, 3 pin 5 Amp.
M&L socket outlet piano flush type 2 in 1, 3 pin 5 and 15 Amp.
S&F fan regulator electronic socket type.
M&L switch flush type bell push button 6 Amp.
S&F modular white cover plate with frame, 1 module/2 module.
S&F modular white cover plate with frame, 3/4module.
S&F modular white cover plate with frame, 6 module.
S&F modular white cover plate with frame, 8 module.
S&F Metal Flush boxes 1/2 module.
S&F Metal Flush boxes 3/4 module.
S&F Metal Flush boxes 6 module.
S&F Metal Flush boxes 8 module.
M&L modular switch 1 way 6 Amp, 1 module.
M&L modular bell push switch, 6 Amp, 1 module.
M&L modular socket, 6A-2/3 pin combined, 2 module.
M&L modular switch 16 Amps, 1 module.
M&L modular socket 16 Amps, 6 pin, 2 module
S&F modular fan step regulator, 120W - 2 module.
S&F bell Buzzer AC 230Volts single pole.
S&F bell Ding dong AC 230 Volts single pole.
S&F Ceiling Rose 65x17mm three terminals after dismantling old one.
S&F lamp holder, PVC/Polycarbonate type and back plate suitable for batten fitting.
S&F 1X18 watt incl taking down wall mounted, new generation LED T-8 Retro fit for multipurpose application with LED Rod, made from exturded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
S&F incl taking down 36/40 watt recessed mounted LED luminaire suitable for armstrong/grid ceiling with super bright LED fittings with connector block etc with short circuit protection, open protection, reverse polarity protection, high voltage protection complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
S&F in replacement of old UNSV building light 45 W IP 65 LED security light for building luminaire comprising of die cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 45 W. The LED make must be of >80 lumen/watt. The driver must be power factor>0.95 with short circuit protection, open circuit protection, reverse polarity protection, high voltage protection. The luminaire must have secondary optics with perfectly matched lens for better light control with GI bracket of suitable size and clamps with fixing accessories complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/Aluminium wiring and removing materials from site as directed.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 Volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2.5 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 4 sqmm cable alongwith one run of 2.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 Volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
S&F MCCB DB TPN 4 Way vertical type factory made IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including provision for one MCCB upto 125A after dismantling old one.
S&F MCB DB TPN 4 Way vertical type factory made IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including provision for fixing of one MCB FP upto 125A after dismantling old one.
S&F MCB DB SPN 8 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed.
S&F MCB DB SPN 4 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed.
S&F MCCB 125 Amp 16 Ka for fixing in DB all as directed by Engr-in-Charge.
S&F MCCB 63/100 Amp 16 Ka for fixing in DB all as directed by Engr-in-Charge.
S&F MCBs 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB . (DB will be measured and paid separately under respective items of sch A):-
MCB 'C' curve SPN 40 to 63 Amps.
MCB 'B' curve SP 5 to 32 Amps.
MCB 'C' curve FP/TPN 40 to 100 Amps.
M&L in repair earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR Part-I and testing on completion including necessary excavation and earth work in any type of soil, PCC (1:3:6) type C-1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe, 15mm dia, light grade, 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
Collecting Fans from Store yard of AGE E/M, ceiling/exhaust/wall mounted fans of any size and any make/model, moving to reputed workshop as directed by GE/Engineer-in-Charge, dismantaling the same, cutting and removing the old defective/burnt out winding, cleaning the core of the fan motor, re-winding the fan motor by using machine with supper enemelled copper winding wire and using insulating materials, varnishing the assembly and re-assembling the fan including testing etc. complete all as specified and directed by Engineer-in-Charge. MAKE of winding wire : Devi Dayal/Chetak/HTP Thulax. Note: All defective/unserviceable parts/items other than winding wire, varnish, insulating material, bearings, capacitors and flexible wires shall be measured separately and paid for under respective item of this schedule:-
All as per item No. 42 here-in-before but for ceiling fans of 1400 mm sweep any type.
All as per item No. 42 here-in-before but for ceiling fans of 1200 mm sweep any type.
All as per item No.42 here-in-before but for exhaust fans of 230/300 mm sweep any type complete all as specified and directed by Engineer-in-Charge.
All as per item No. 42 here-in-before but for exhaust fans of 400/450 mm sweep any type complete all as specified and directed by Engineer-in-Charge.
All as per item No.42 here-in-before but for wall mounted flame proof fans of any sweep complete all as specified and directed by Engineer-in-Charge.
S&F in repair capacitor 2.5 mfd fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F in repair capacitor 3.15 mfd fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F in repair capacitor 4 mfd fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F in repair Ceiling fan blades (Set of three blades) suitable for 1200/1400 mm sweep ceiling fan duly painted with synthetic enameled paint fixed in replacement complete all as specified and directed.
S&F in repair Exhaust fan blades (Set of three blades) suitable for 400/450 mm sweep duly painted with synthetic enameled paint fixed in replacement complete all as specified and directed.
S&F in repair Exhaust fan blades (Set of three blades) suitable for 230/300 mm sweep duly painted with synthetic enameled paint fixed in replacement complete all as specified and directed.
S&F in repair MS clamps for ceiling fans complete with rubber real of any size/make/sweep/model fixed in replacement complete all as specified and directed by Engineer-in-Charge.
M&L for suitable size of bolts, nuts, body screws, GM bushes and safety pin/split pins for any type/size/make and model of extg fan as required , fixed in replacement, complete all as specified and directed.
Shaft for any type/size/make and model of fans as required fixed in replacement, complete all as specified and directed.
M&L for painting with two coats of white synthetic enamel paint and marked MES No by black permanent marker all as directed by Engr-in-Charge.
S&F in repair Ball bearing of ceilling fans of any sweep/size/make/ model fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F in repair Ball bearing of Exhaust fansof any sweep/size/make/ model fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F in repair Upper and lower canopy complete with adjusting screws as required, fixed in replacement complete all as specified and directed by Engineer-in-Charge. Make: Usha/ Orient/MIE/Jaoco
S&F in repair Down rod 20 mm dia, GI tubing medium grade 45 cm to 60 cm long as require fixed in replacement at site complete all as specified and directed.
S&F in repair Louvers made of GI Sheet, suitable for 450 mm sweep exhaust fans fixed in replacement complete all as specified and directed.
S&F in repair Louvers made of GI Sheet, suitable for 230/300 mm sweep exhaust fans fixed in replacement complete all as specified and directed.
M&L for taking proper shut down from power house in presence of rep of AGE E/M sub divn before disconnecting the cable and reconnecting the cable before clearing shut down carrying out following works as directed by Engr-in-Charge. Note : U/S Item like MCB, MCCB will be measured and paid separately (a) Cleaning of DB by air blower. (b) Cleaning of terminal of MCCB by CRC 26 sprays. (c) Cleaning of bus bar by CRC 26 sprays. (d) fixing naked wire through flexible pipe. (e) fixing PVC cable lugs of different size to MCB. (f) fixing nut bolts if required and make good disturbed surface by plastering and welding hinges of DB door/ Box of DB.
Conduit wiring using approved colour codeing as per IS with FRLSH smoke free non toxic, non corrosive with copper cable 1.5 sqmm confirming to IS : 694 nominal area single core insulated and unsheathed stranded cable 1100 volt grade and including ERW stove enameled conduit heavy duty ISI marked and unsheated copper conductor 1.5 sqmm area as earth wire as earth continuity conductor complete all as specified and directed by Engr-in-Charge.
Conduit wiring using approved colour codeing as per IS with FRLSH smoke free non toxic, non corrosive with copper cable 2.5 sqmm confirming to IS : 694 nominal area single core insulated and unsheathed stranded cable 1100 volt grade and including ERW stove enameled conduit heavy duty ISI marked and unsheated copper conductor 1.5 sqmm area as earth wire as earth continuity conductor complete all as specified and directed by Engr-in-Charge.
S&F switch flame proof rotary type with termination box in LM6 16 A single pole 250V.
S&F flame proof rotary type switch socket & plug conbined with termination box in LM6 16 A single pole 250V.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade FRLSH smoke free non toxic, non corrosive 4 sqmm drawn through ERW stove enameled conduit heavy duty ISI marked 25mm dia as per IS specification fixed on wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated FRLSH smoke free non toxic, non corrosive 2.5 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site. Note : Two runs of 4 sqmm cable alongwith one run of 2.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
S&F rigid non metallic PVC conduit medium grade 20 mm external dia ISI marked with accessories such as tees, bends, junctin boxes bell mouth tube ends including fixing accessories, locks as couplers lock nuts pipe hooks ets concealed in walls ceiling etc complete all as specified and directed.
S&F submain wiring with four runs of single core 6 sqmm PVC insulated unsheathed stranded copper FRLS conductor drawn in concealed conduit including 4 sqmm copper stranded conductor PVC insulated FRLS earth wire connected to main board complete all as specified and directed. Note : 04 Nos cable and 01 No earth wire shall be measured together as one length).
S&F including taking down of flame proof weather proof LED light fitting 2 x 20W with all accessories including lamp and necessary connection wire and testing complete.
S&F LED flame proof flood light with LED lamp wattage 60 W CMRI approved with die cast aluminium housing with heat resistant toughened glass IP 66 protection comlete with control gear box and all accessories.
M/s Luxmi Constructions
M/s SHIVA BUILDERS
Rasvinderpalandco
M/s GURFATEH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .