Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.3 L+₹3.5 L (11.7%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹33.5 L+₹3.7 L (12.4%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹34.8 L+₹4.9 L (16.6%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹36.8 L+₹7.0 L (23.5%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR / MAINT OF INTERNAL ELECTRIC WORKS IN CERTAIN MD/ OTM ACCN OF ZONE-I (AEPTA) AND ZONE-II B AREA AT JAIPUR MIL STN
2021_MES_415629_1
GE/J-65/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JAIPUR
As Per NIT
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹80,000
Yes
2 Mar 2021
23 Jan 2021
22 Feb 2021
23 Jan 2021
20 Feb 2021
6 Feb 2021
23 Jan 2021 - 5 Feb 2021
60 days
Amount
Taking down carefully aluminum or copper point wiring with PVC casing capping or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
M&Lfor rewiring point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into concealed conduit and terminated in modular metal flush boxes 1.0mm thick for mounting modular cover plate & frame, switches, sockets, fan regulators as required for one light point controlled by one switch.
All as per item No. 02 here-in-before but one fan point controlled by one switch.
All as per item No. 02 here-in-before but one light point controlled by two, two way switch.
All as per item No. 02 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 02 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 02 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into into existing concealed conduit and terminated in modular metal flush boxes for mounting modular cover plate & frame for one socket point 16 Amps controlled by one switch.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenlic laminated white sheet cover for mounting sheet cover for mounting switches, sockets, fan regulators : one light point controlled by one switch.
All as per item No. 09 above but one light point controlled by two, two way switch.
All as per item No. 09 above but one fan point controlled by one switch.
All as per item No. 09 above but one socket outlet 6 Amps controled by one switch on the same board with other switches.
All as per item No. 09 above but one socket outlet 6 Amps controlled by one switch on independent board.
All as per item No. 09 above but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 4.0 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 4.0 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0mm covered with 3mm thick phenlic laminated white sheet cover for mounting sheet cover for mounting switches, sockets for one 16 Amps socket outlet point controlled by one switch on independent board.
M&Lfor rewiring point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into concealed conduit and terminated ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenlic laminated white sheet cover for mounting sheet cover for mounting switches, sockets, fan regulators one light point controlled by one switch.
All as per item No. 16 here-in-before but one fan point controlled by one switch.
All as per item No. 16 here-in-before but one light point controlled by two, two way switch.
All as per item No. 16 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 16 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 16 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn concealed conduit and terminatedivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenlic laminated white sheet cover for mounting sheet cover for mounting switches, sockets, for one socket point 16 Amps controlled by one switch.
S&F angle holder, insulated polycarbonate body with back plate complete.
S&F switch piano flush button single pole one way 6 Amp complete.
S&F switch piano flush button single pole one way 16 Amp complete.
S&F switch flush type, 6 Amp, single pole, two way complete.
S&F bell push, flush type, 6 Amps 240 volts complete.
S&F socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete.
S&F switch modular 1 way 6 Amps, 230 volts, 1 module.
S&F modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts.
S&F modular switch 1 way 16 Amps, 230 volts, 1 module. Make : Legrand mylinc cat ref No. 675511 or equivalent in Schneider Zencilo series/Crabtree Murena series as approved.
S&F modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts.
S&F modular fan regulator 120 watts, 2-module AC 230 Volts.
S&F switch modular 2 way 6 Amps, 230 volts, 1 module.
S&F modular bell push 6 Amps 1 module.
S & F modular blanking plate 1 module.
S&F modular whiter cover plate with frame 1/2 module.
S&F modular whiter cover plate with frame 3 module.
S&F modular whiter cover plate with frame 4 module.
S&F modular whiter cover plate with frame 6 module.
S&F modular whiter cover plate with frame 8 module.
S&F Modular metal flush box 1/2 module
S&F Modular metal flush box 3 module
S&F Modular metal flush box 4 module
S&F Modular metal flush box 6 module
S&F Modular metal flush box 8 module
S&F door bell AC 240 volts, single pole complete.
S&F in replacemet switch piano flush button single pole one way 6 Amp complete.
S&F in replacement switch piano flush button single pole one way 16 Amp complete.
S&F in replacement bed switch flush type, 6 Amp, single pole, one way complete.
S&Fin replacement bell push, flush type, 6 Amps 240 volts complete.
S&F in replacement socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F in replacement socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F in replacement switch modular 1 way 6 Amps, 230 volts, 1 module.
S&F in replacement modular socket 6 Amps, 2/3pin combined 2 module AC 230 volts.
S&F in replacement modular switch 1 way 16 Amps, 230 volts, 1 module.
S&F in replacement modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts.
S&F in replacement modular fan regulator 120 watts, 2-module AC 230 Volts.
S&F in replacement switch modular 2 way 6 Amps, 230 volts, 1 module.
S&F in replacement modular bell push 6 Amps 1 module. Make : Legrand mylinc at ref no. 675504 or equivalent in Schneider Zencilo series/Crabtree Murena series as approved.
S & F in replacement modular blanking plate 1 module.
S&F in replacement modular whiter cover plate with frame and metal flush box 1/2 module.
S&F in replacementin replacement modular whiter cover plate with frame and metal flush box 2 module.
S&F in replacementin replacement modular whiter cover plate with frame and metal flush box 3 module.
S&F in replacement modular whiter cover plate with frame and metal flush box 4 module.
S&F in replacement modular whiter cover plate with frame and metal flush box 6 module.
S&F in replacement modular whiter cover plate with frame and metal flush box 8 module.
S&F in replacement modular whiter cover plate with frame and metal flush box 12 module.
S&F in replacement modular whiter cover plate with frame and metal flush box 16 module.
S&F ceiling rose 3 plates polycarbonate body complete.
M&L for sub main wiring along with earth continuity conductor with, PVC insulated FRLS multistranded copper conductor cable (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories 2x4Sqmm + 1x4.0 Sqmm earth wire in 20mm dia conduit.
All as per item No. 73 above but 2x6 Sqmm + 1x6 Sqmm earth in 20 mm dia conduit.
All as per item No. 73 above but 2x6 Sqmm + 1x6 Sqmm earth in 25 mm dia conduit.
All as per item No. 73 above but 2x10 Sqmm + 1x10 Sqmm earth in 25mm dia conduit.
M&L for earthing with galvanized steel earth plate electrode 600mmx 600mmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with the top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth lead wire 4mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No. 03 of SSR Part -I connected to earthing point and including 15mm bore light grade G.I. protection pipe (upto 7.5 mtr from edge of the pit), PCC pit in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40mm thick cover, watering arrangement with funnel and wire mesh and 20mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earh work including testing on completion.
Supply, installation, testing and commissioning of LT panel board fabricated out of 2mm thick stainless steel (SS 316) with copper bus bar 4 pole equal of capacity in colour code R, Y & B, 100 Amps 415 Volts indoor type wall mounted of size not less than 750mmx650mmx250mm, installed on procelain insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class IP 42 class, front opening & compartmental type with approach for cable entry and for easy maintenance duly internally wired with FRLS, PVC insualated stranded copper conductor cable of 1.0 Sqmm including LED indicator for R, Y & B and comprising of the following :- Incoming : One number MCCB 125 Amps 4 pole 16 KA 415 Volts, 70-100%, 50 Hz Make Legrand Cat No. 4200 16 or equivalent in Hager/Schneider. Outgoing : (a) Single phase tamper proof meter with optical port 10 to 60 Amps-04 Nos. Make : Secure Saral or equivalent in HPL/L&T. (b) MCB DP 63 Amps 'C' series 10 KA AC 240 volts-05 Nos. Make : Legrand Cat Ref No. 404618 to 40408620 or equivalent in Hager/Schneider as approved
S&F tamper proof static single phase 2 wire direct reading energy meter (whole current) with LED display, (10-60) Amps, 240 volts AC supply, accuracy class 1.0 having an optical/RS 232 port to download the stored data by an external MRI instrument. Make : Secure icredit 350 or equivalent in L&T/HPL as approved.
S&F louvers only for 300 mm exhaust fan of metallic body as approved.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 4 ways. Make : Legrand Cat Ref No. 507610 or Schneider Cat No. A9HSND04 or Hager as approved.
All as per item No. 77 above but SPN, 240 volts, 8 ways. Make : Legrand Cat Ref No. 507611 or Schneider Cat No. A9HSND12 or Hager as approved.
All as per item No. 77 above but SPN, 240 volts, 12 ways. Make : Legrand Cat Ref No. 507612 or Schneider Cat No. A9HSND12 or Hager as approved.
All as per item No. 77 above but SPN, 240 volts, 2 ways. Make : Legrand Cat Ref No. 507791 or Schneider or Hager as approved.
All as per item No. 77 above but TPN, 415 volts, 4 ways. Make : Legrand Cat Ref No. 507670 or Schneider or Hager as approved.
S&F MCCB four pole, 125 Amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs as required. Make : Legrand Cat Ref No. 420016 or equivalent in Schneider /Hager as approved.
S&F MCB distribution board, tripple pole and neutral, powder coated CRCA steel sheet, suitable for MCCB incomer upto 160 Amps, 4 way 415 volts, degree of protection IP 43, IK-09 with reversible double door, recess mounted, having 250 Amps insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. Make : Legrand Cat Ref No. 507745 or equivalent in Hager/Schneider as approved
S&F MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete. Make : Legrand Cat Ref No. 508587 to 408595 or equivalent in Hager/Schneider as approved
All as per item No. 83 above but double pole 10 to 40 Amps.Make : Legrand Cat Ref No. 408631 to to 408636 or equivalent in Hager/Schneider as approved
All as per item No. 83 above but double pole 40 to 63 Amps.Make : Legrand Cat Ref No. 4046 37 to 4086 39 or equivalent in Hager/Schneider as approved
All as per item No. 83 above but double pole 40 to 63 Amps.Make : Legrand Cat Ref No. 404618 to 408620 or equivalent in Hager/Schneider as approved
All as per item No. 83 above but four pole 40 to 63 Amps.Make : Legrand Cat Ref No. 408700 to 408702 or equivalent in Hager/Schneider as approved
S&F in repair LED (1.2M) smartbrite extra batten made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2500 lumens/22 watt at a minimum system efficacy of 4000 lumen per 22 watt and total power consumption not more than 40 watt including driver. It has a rated system life time of 25000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete.Make : Philips Cat Part No : BN 021LED 25S 6500 PSU GR S1
S&F in repair LED fixture 10 watt having lumen output 100 lumens per watt including connection. Make : Philips Cat Part Ref No : BN 021LED 25S 6500 PSU GR S1 or equivalent as approved by GE
S&F in repair LED bulk head fitting 9 watt IP 66 & IK 09 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable all as per specified. Make : Philips Cat Ref No . WT 202W LED 6S PSU S2 PC or equivalent in Panasonic/Havells/CG as approved.
Supply and fixing in replacement 8 watts wall mounted LED decorative luminary with standard accessories and lamp inclduing fixing the same with existing wall. Make : Havells Cat Part No. LHJE01106499 or equivalent in Bajaj/Philips as approved by GE
S&F energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens 36 Watts having constant current electronic driver duly connected with 0.5 Sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire. Make - Philips cat ref no. RC240B LED33S- 6500 PSU OD WH or equivalent in Havells/CG as approved by GE
S&F in repair recess mounted LED panel of size 220mmx220mm, 12 watts 1500 lumen output having luminous efficacy >85 lm/W, 6500K, 50Hz, p.f. >0.90, CRI80, THD <30%, 25000 burning hours including making connection. Make : Philips Cat Part No SM 260C LD 12S-6500 PSU WH or equivalent in Havells/CG as approved by GE
S&F in repair white power cotated CRCA full glow recess mounted LED bacalit panel light fitting of size 305mmx1220 mm (1' x4') 36 watt having constant current electronic driver duly connected with 0.5 Sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire. Make : C&S Cat Ref No CYGNUS-C/36W/1 x 4 W or equivalent in Havells/CG as approved by GE
Supply and fix in replacement LED luminary 35 watts IP 66 5700K outdoor luminary with standard accessories and making connection with existing light point with 3 core 1.0 Sqmm PVC insulated multistranded copper conductor wire including fixing the same on existing Gi bracket complete. Make Philips Cat Ref No . BRP050 LED 036 CW RI MP PCSI PSU GR or equivalent in Bajaj/CG as approved by GE
Supply and fixing in replacement GI bracket made out of 32mm dia GI medium grade pipe of length 90 Cms long bend shape and size as per site requirement including 02 Nos of MS flat 40x5mm 200mm long bend to shape as required to fix the G bracket with existing wall using 04 Nos of MS fastener 10mmx100mm long with nut, bolts and washers complete.
Supply and fix in replacement 10 watts LED T-lamp B-22 base (warm white/Golden Yellow) 100 lumens, AC 220 volts . Make : Philips Part No. 9290018611 or equivalent in CG/Bajaj as approved by GE
Taking down MCB distribution boards with incoming and outgoing controls any make any capacity after disconnecting complete.
Taking down carefully sub main wiring with PVC casing capping/PVC surface conduit and making good disturbed surfaces complete.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core.
Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete.
Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25 cms thick complete.
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the ground level/starting point compalete all as specified and directed.
Sand cushioning to the under ground electric cable complete all as specified considering 19.75 of SSR part -I
S&F steel tubes 40 mm bore light grade ISI marked with medium grade fittings for cable protection as required.
M&L Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall build on cement mortar 1:4 and 2 coats of white/colour washing to match the surface complete.
Rewinding the motor of table / pedestal / cabin fan 400 mm of all types and make with super enameled copper wire of existing gauge and approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete.
Rewinding the motor of ceiling fan 1200/1400 mm of any type and make with super enameled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete.
Rewinding the motor of fresh air/exhaust fan 230/300 mm of any type and make with super enameled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete.
Opening ceiling fan of any make any sweep for overhauling, providing fresh clean lubricating oil / grease including minor repairs, renewal of split pins, re-assembling and testing for satisfactory operation complete. (Note - Any u/s parts as renewed shall be measured separately).
Rewinding the motor of wall mount air circulator fan of size 600 mm of any type and make with super enameled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete.
Renewal of ball bearing of ceiling / exhaust fan of any size and make as required with alignment of shaft and testing complete. Make - SKF (6201 to 6203) or equivalent in TATA as approved by GE
Renewal of AC film capacitor 2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete. Make - Havells cat ref no. 2.5 mfd / 440V / PLWW / 25x45 or equivalent in Epcos / Usha as approved by GE
Renewal of AC film capacitor 4.0 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete. Make - Havells cat ref no. 4.0 mfd / 440V / PLWW / 28x52 or equivalent in Epcos / Usha as approved by GE
Renewal of self lubricating bush of gun metal of same type for ceiling fan / exhaust fan as required.
Renewal of shaft of approved quality for ceiling fan / exhaust fan any make any type & size as required.
M&L for painting of table / pedestal / cabin fan of any sweep and make with one or more coats of spray painting with best quality enamel paint of required colour and approved brand to give an even shade and polishing with rubbing compound and wax polish including cleaning of surface with detergent etc and writing MES No with black paint as required.
M&L for spray painting of ceiling fan of any sweep and make with one or more coats of spray painting with best quality enamel paint of required colour and approved brand to give an even shade and polishing with rubbing compound and wax polish including cleaning of surface with detergent etc and writing MES No in a height of minimum 30 mm with black paint as required .
M&L for scraping completely fresh air / exhaust fan of any sweep and make and providing with two or more coats of spray painting with best quality enamel paint of required colour and approved brand to give an even shade over a coat of red oxide primer and polishing with rubbing compound and wax polish and writing MES No with approved colour paint as required.
Transportation of ceiling fan / exhaust fan from store to site or site to store as required.
Installing, testing and commissioning repaired ceiling fans at any location in cantonment Jaipur including connection complete.
Renewal of rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of any size and make as required.
Renewal of PVC canopy suitable for ceiling fan of any size and make as required.
Renewal of down rod of ceiling fan made of MS pipe 15 mm bore including cutting, threading, painting etc as 30 cm to 60 Cm required.
M&L for clamp and back plates fabricated from steel sections conforming to Gde Fe 410-O or Fe 310-O including nuts, bolts, washer, drilling holes for bolts in any shape or size for fixing ceiling fan complete.
Renewal of PVC insulated and sheathed flexible 3 core cable with copper conductor of size 0.5 sqmm complete.
Supply and fix in replacement PVC fresh air fan 250 mm sweep with louvers, fan motor and accessories complete including making connections..
Supply and fix in replacement metalic body heavy duty Exhaust fan 250 mm sweep with louvers, fan motor and accessories complete including making connections.
Supply and fix in replacement PVC fresh air fan 200 mm sweep with louvers, fan motor and accessories complete including making connections.
Supply and fixing ceiling fan 1200mm sweep 50 Hz AC 230 votls, 5 star rated in white colour with fan motor, blade set, 0.45 mtr down rod, canopy set, rubber reel including 0.5 Sqmm three core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling and writing MES No. on fan body as required. Make : Havells Model No. ES- 50 or equivalent in Orient/CG/Standard as approved by GE
Taking down carefully storage type water heater (geyser) any make and capacity from clamp/bolts including disconnecting water and electric connection and re fixing the same and connecting up after cleaning of geyser and repair complete. (Note - Repair work shall be measured separately).
Opening up geyser of capacity 25/50 litre, checking defect, taking out u/s parts and re-assembling after carrying out repair / renewal work including nuts / bolts / wahers / gaskets / fusible plug etc wherever required and minor items not included separately in schedule. (Note - U/s parts shall be measured separately under relevant item of schedule as supply only).
Supply only geyser apparatus plate (any make, any type) copper alloy chromium plated suitable for geysers 25/50 litre capacity including rubber gasket, nuts / bolts etc complete.
Supply only heating element 2.0 KW/1.5 KW , 230 volts, ISI marked suitable for 50/25 litre capacity geysers of any type as required.
Suppply only thermostat ISI marked suitable for 25/50 litres geysers as required.
Supply only stainless steel inner tank suitable for 25 litre capacity geysers housing complete.
Suppply only stainless steel inner tank suitable for 50 litre capacity geysers housing complete.
Repair of inner copper tank of geysers 25/50 litre capacity with gas welding not exceeding 5 mm thick to make it leak proof complete.
Repair of apparatus plate of geysers 25/50 litre capacity by brazing not exceeding 5 mm thick complete.
Renewal of brass chromium plated, flexible pipe connection 15 mm bore 450 mm long heavy duty suitable for hot water supply with two numbers brass chromium plated nuts at end complete.
M&L for painting of geyser 25/50 litre with two coats of synthetic enameled white paint after removing old paint and preparation of surface and writing MES No (Letters height 10 cm) complete.
S&F water heater 25 litre capacity BEE star rating 5 in approved colour, heating element 2.0 KW, adjustable temperature setting knob for temperature setting between 25° C to 75° C, outer tank made of non metallic engineering plastic, inner tank made of extra thick superior cold rolled steel provided with high density PUF insullation complete. Make: Havells Adonia or equivalent in Daspass or Recold or Bajaj as approved.
S&F in replacement LED post top light 25 Watts in spherical shape polycarbonate diffuser & IP 65 including recessing mounting pipe of size not less than 32mm dia in existing PCC/brick gate post using CM in 1:4 and making connection using 3 core 0.5 Sq.mm PVC insulated cable complete. Make : Bajaj Cat Part No. BLPTSP 25W LED or equivalent in Philips/CG/Havells as approved by GE
Renewal of Indipendent,constant current LED control Gear input voltage range: 140-270 V, suitable for 36 watt 1' x4' white power cotated CRCA full glow recess mounting LED backlite panel. Make : Havells Cat Ref No : LSSCRX1791
S&F in replacement of switch socket combined 20A & 10 A, 240V 50 Hz, combined Unit box with 2 fixing hole all as specified. Make : Anchor, Cat Ref No 14310 or its equivalent.
S&F in replacement of switch socket combined 6A, 2 in 1 S.S Comb, with Box 240V 50 Hz, with 2 fixing hole all as specified. Make : Anchor, Cat Ref No 50508 or its equivalent.
Renewal of PVC insulated over all PVC sheathed three core copper cable of size 2.5 sqmm complete.
S&F 20 amp, single pole and neutral socket outlet with 2 pole and earthy, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for socket outlet with and including one number single pole 'C' series MCB 16 amp as required. Make- Legrand cat ref no. 507811 & 408592 or equivalent in Hager/Schneider as approved by GE
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators as required for the following :- (a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One light point controlled by two, two way switches.
(d) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(e) One socket outlet 6 amp controlled by one switch on indepdendent board.
(f) One bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.0 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets as required for one 16 amp socket outlet point controlled by one switch on independent board.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x16 mm ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets for one 16 amp socket outlet point controlled by one switch on independent board.
Supplying and fixing LED batten (1.2 m) made of CRCA sheet housing with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 19 watt (including driver) having colour temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make - Philips cat ref no. ENDURALED BATTEN "BN 108C LED 20S PSU CDL WH" or Bajaj cat ref no. BLTRU 20W WH VIVA or equivalent in other specified make as approved by GE
Supplying and fixing in repairs LED batten 9 watt, 900 lumens operating voltage 160 to 360 volts, colour temperature 6500K including connection all as per Philips Astra Line 9-Watt LED Batten or equivalent in Wipro or CG as approved by GE
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 50 mm & inner pipe dia 25 mm duly filled with highly conductive and anti corrosive compound tested from NABL certified Laboratory of required quantity laid by by digging a bore of 150 mm dia surrounded by soil friendly backfill compound including connection with galvanised earth wire 4 mm dia from earth electrode to the equipment to be earthed duly protected in 15 mm medium grade GI pipe upto 7.5 m, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40 mm thick cover with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 2.0 ohm complete.
Supplying and fixing in repairs phenolic laminated white sheet cover 3.0 mm thick, cut into required size suitable for fixing on existing boards / terminal boxes for mounting switches, sockets, regulators as required.
Fixing / repairing loose and disconnected point wiring or diverting the route of point wiring upto a length not exceeding 2.0 metre including required cable of same size and carrier (PVC casing caping or conduit, domestic gang box etc) with fasteners etc and making good disturbed surfaces even and smooth using CM (1:3) as required.
Supplying and fixing in repairs switch type hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity including connecting up complete. Make - Havells Reo / Anchor Penta PC / SSK as approved by GE
Supplying and fixing in repairs modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent in Schneider Zencelo or Crabtree Murano as approved by GE
Supplying and fixing in repairs modular socket 6 amp 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675550 or equivalent in Schneider Zencelo or Crabtree Murano as approved by GE
Supplying and fixing in repairsmodular hum free electronic step fan regulator, 100 watt 2 module all as per Legrand cat ref no. 675530 or equivalent in Schneider Zencelo or Crabtree Murano as approved by GE
Supply and fixing in repairs LED batten compact commercial batten both side connection suitable for single T8 LED tube made of PVC housing and prewired connection with LED tube both side connection.
M&L for Polycarbonate NIC seals quick NIP type made of dow polycarbonate with UV additive having seal dimensions 12.7 mm 18.3 mm x 29.8 mm and 2-strand stainless steel twist wire type 304 (wire length 150 mm & dia 0.86 mm) transparent in any of colours viz red, blue, yelow, clear, amber duly laser marked non-erasable unique number and HTML format bar code complete.
Supplying and fixing in repairs energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required. Make - Philips cat ref no. RC365B LED33- 6500 PSU OD WH or equivalent in CG or Havells as approved by GE
S&F in repair modular switch one way 6 amp 1 module all as per Legrand Britzy cat ref no. 673401 or equivalent in Schneider Zencelo or Crabtree Murano as approved by GE
S&F in repair modular switch in repair one way 16 amp 2 module all as per Legrand Brizy cat ref no. 673411 or in Schneider Zencelo or Crabtree Murano as approved by GE
S & F in repair plastic surface boxe 1 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 2 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 3 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 4 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 6 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 8 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 12 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 16 moduler for fixing modular switch and socket
S&F in repair modular switch one way 6 amp 1 module all as per Legrand Mylinc cat ref no. 675501 or equivalent in Schneider Zencelo or Crabtree Murano as approved by GE
S&Fin repair modular switch two way 6 amp 1 module all as per Legrand Mylinc cat ref no. 675502 or equivalent in Schneider Zencelo or Crabtree Murano as approved by GE
Taking down industrial plug and socket including one number single pole MCB any make, any capacity after disconnecting complete.
Renewal of street light fittings like tube light/CFL/T5 of any discription with greenline high efficiency LED street light luminaire 25 watt complete with drive, pressure die cast aluminium housing, UV stablized polycarbonates cover, in built power unit, IP 65 protection including mounting bracket made of 25 mm GI pipe, medium grade ISI marked not less then 1.2 m bend in shape with two number clamps, nuts, bolts, washeres as required. Make Philips cat ref No BRP022 LED 10 CW MR S 1 PSU GR or equivalent in Havells or C&S as approved by GE
Schedule of Credit
M/s Radhey Enterprises
M/S Sheeba Enterprises
SHREE BHAGWATI ENTERPRISES
M/S TRADE LINKERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .