Superintending Engineer
132 KV S/S Lalkuan Campus, Ghaziabad.
Works at sub-station
2023_UPTCL_789644_1
Short Term E-Tender No- T-105/ETC/GZB/2022-23
Open Tender
Electrical Works
Turn-key
90 days
220 KV S/S Muradnagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
AS PER NIT
₹74,000
9 May 2023
24 Mar 2023
10 Apr 2023
24 Mar 2023
10 Apr 2023
24 Mar 2023
Amount
Work Portion:- (Dismentling of Structure and Equipment)
Dismantling of Main structure lattice type ATM. Consisting of column. The job consist of shifting of all material from site to store with GI nut & bolt, flat and spring washer.
Dismentling of 132KV PT Cutting of earthing, dismentling of jumpher.Electrical Connection, Structure and safe shifting site to store.
Dismentling of 132KV BBL isolator Cutting of earthing, dismentling of jumpher.Electrical Connection, Structure and safe shifting site to store.
Dismentling of 132KV LA Cutting of earthing, dismentling of jumpher.Electrical Connection, Structure and safe shifting site to store.
Dismantling and Erection of 132/33 KV 63 MVA Transformer at 220 KV Sub-Station Muradnagar.
Shifting of main tank of defective 63 MVA, 132/33 KV transformer from unloading point up to plinth, approximate 20 mtrs distance including turning of tank, if required including all T&P and all other works required to complete the job satisfactory as per tech specn.
(a) Additional shifting 1 Job for every 5 Mtr.
Dragging of new 63MVA Transformer main tank from unloading site to transformer plinth at 220KV S/S Muradnagar approx. distance 20mtrs
Complete, erection of new 63 MVA T/F work includes erection of radiator, conservator tank, bushing with its turrets (if available) connecting of all oil pipe line, erection of cooling fans, making control cables connection, buchholz relay etc. for completing the work, topping of T /F oil and final oil filling in tank, radiator, conservator tank and all other associates work for completion of job satisfactory.
Earthing of main tank of new 63 MVA T /F by using M.S. flat 50X6 / 75X10 mm size, it’s jointing with already laid earth mat / Deltas. Neutral bushing support for its earthing work.
Making of Delta earthing for 63 MVA transformer as per UPPTCL Norms
Placement of new RTCC panel of this new 63 MVA T /F in control room at 220KV S/S Muradnagar including its Termination & fitting and laying of control cable if required as per site requirement and its connections.
Jumpering of 63 MVA T/F from HV with single Moose/Zebra/ Panther and LV Side with Twin Moose Conductor.
Centrifuging of complete T/F oil in T/F by connecting centrifuging pipes circulating the T/F oil through PVT. centrifuging machine and taking the BDV value of the oil periodically till the required value is achieved .Approx. 25KL
Along with new deluge valve (150 NB) modification of emulsifier pipe line with supply & installation of high velocity automatic water spraying system for 63 MVA T/F including, laying of fire detection/water pipe line, valves, Quartzoid bulb, HVWS nozzles along with all material complete as per details:
Supply & installation testing commissioning of quick opening flood, deluge value of HD of 150 NB as per Max working pressure 10 Kg/cm2, as per specification (HD/Mather Platt/equivalent) (In nos.).
Supply & installation & Commissioning of gate value (sluice Valve/Butterfly valve) as per IS specification (IS Code: 14846) of (Zoloto/Kartar/Sir make) (In nos.) 150 NB
Supply & installation & testing commissioning of “Y” Type strainer (Kartar/Sir/Kalpana/Agro make) of dia Max working pressure 7 Kg/cm2 (In Nos. ) 150 mm
Supply & laying of different sizes of M.S Pipe ‘B’ class for fire water pipe line/support as per IS specification (IS code-1239) as per drawing enclosed. Complete with elbow Tee, Socket reducer etc. with anti-corrosive treatment with detail as below: (In Mtr)
Supply and laying of different size of GI Pipe ‘B’ class for fire detection/Water pipe line as per specification (IS Code-1239) as per drawing enclosed complete with elbow, Tee Socket. Reducer, (In Mtr)
Supply & Installation of Flanges as per IS-1538 of different sizes as per drawing work include proper butt welding with pipe & proper packing and coupling with Nut & Bolt.
Supply & installation & commissioning of high velocity water spray nozzles flow capacity 3.5 kg/cm2. Spray core angle90°. (In Nos.)
Supply & installation & commissioning of Quartzoid Bulb detectors (QBD) Operate at 90°C, sensing at rated temp for actuation of the element 10-12 sec (In Nos.)
Supply & Installation & testing commissioning of fixed different switch (Danfoss/Indfoss make) type pressure switch Range 1-10 Kg/Cm2 (In Nos.)
Pressure gauge as per IS specification IS code 3624, Accuracy 1/+5% (In Nos.)
Erection of Main Bus (A):- Dismantling of various Single Phase Bus Bar of 132 KV with different type conductor and different length of span as mentioned below. The work includes cutting & bending of conductor, fixing of single /double bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification.
132 KV Main Bus-I of single Tarantulla conductor
132 KV Jumper of single Zebra conductor.
Dismantling of 132 KV string under Beam to pass the jumper including dismantling of disc insulator and suspension fitting complete with all work.
Proper stacking and shifting of Main & auxiliary structure in open switchyard at erecting place as per shop bill norms.
Erection of Main & Auxiliary structure lattice type ATM, ABL, BCT, ALP, BPL etc. consisting of column, beam, peak, mast etc. and auxiliary structure for installation of isolator, CTs, PTs, LA etc. erection of structure as per drawing with the help of GI nuts & Bolts flat spring washer matching the hole, cutting and matching the member if required include cost of all men and T & P excluding GI structure nut and bolts to complete the work erection of main & auxiliary structure lattice type ATM, BTM, AXM, ABL, CCM,CGM, EKR, BBR, BCT, ALP, BPL, BTI etc. upon foundation and its proper tightening.
Making hole in part of GI Main/auxiliary structure / cutting of GI angle drilling of hole existing/ defective structure /plate/Angle and grinding machine with all cost of men, T & P etc.
Erection of following equipment as per instruction manual of various equipment’s and technical specification including shifting of material / equipment from store to erection site including all other associated works to complete the job satisfactorily.
Erection of 145 KV Potential Transformer
Erection and mounting of 145 KV PT junction box.
Erection of 145 KV Bus Isolator without earth switch (Motorized)
Stringing of various Single Phase Bus Bar of 132 KV with different type conductor and different length of span as mentioned below. The work includes cutting & bending of conductor, fixing of single /double bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification.
132 KV Main Bus-I of Twin Moose conductor
132 KV Jumper of single Moose conductor.
132 KV Jumper of Twin Moose conductor.
Stringing of 132 KV string under Beam to pass the jumper including dismantling of disc insulator and suspension fitting complete with all work.
Complete cleaning of disc insulators for all phases by suitable liquid cleaner, testing of IR value by insulation tester, making series connection & ready for hoisting with all cost of men, T & P consumables etc.
132 KV side single insulator string
Earthing of equipment’s by cutting straightening, bending, laying 700mm below ground and above ground of following size of MS flat for earthing of main and auxiliary structure, equipment’s structure. Transformer body and its neutral point including welding with main earthmat and with object to be earthed excavation of trenches its back filling. All other associated work as required to complete the work.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Painting of MS flat of different size after cleaning of rusted surface 1st coat of Red Oxide and 2 coat of Bus Green Paint to complete the work.
MS Flat of size 75x10 mm
MS Flat of size 50x6 mm
MS Flat of size 25x6 mm
Supply portion :-
Bolted type Tension fitting for Twin Moose Conductor with turn buckle suitable for 1x10 No Disc insulator complete with hardware set as per technical specification.
Bolted type Tension fitting for Twin Moose Conductor without turn buckle suitable for 1x10 No Disc insulator complete with hardware set as per technical specification.
Bolted type Suspension fitting for Twin Moose conductor suitable for 1x10 No Disc insulator with hardware set as per technical specification.
04 Bolted Type PG clamp suitable for Moose to Moose conductor Complete with HDG nut bolt & washer as per technical specification.
132 KV P.T clamp suitable for Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
Spacer for 100mm spacing for Twin Moose Conductor 02 Bolted completed with hot dip galvanized nut, bolts & washer as per technical sepecification.
Spacer for 250mm spacing for Twin Moose Conductor 02 Bolted completed with hot dip galvanized nut, bolts & washer as per technical sepecification.
132 KV Bus Isolator clamp twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
132 KV Bus Isolator clamp Single Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
Erection of Main Bus (B):-Dismantling of various Single Phase Bus Bar of 132 KV with different type conductor and different length of span as mentioned below. The work includes cutting & bending of conductor, fixing of single /double bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification.
132 KV Main Bus-II of single Tarantulla conductor
132 KV Jumper of single Zebra conductor.
Dismantling of 132 KV string under Beam to pass the jumper including dismantling of disc insulator and suspension fitting complete with all work.
Erection of following equipment as per instruction manual of various equipment’s and technical specification including shifting of material / equipment from store to erection site including all other associated works to complete the job satisfactorily.
Erection of 145 KV Bus Isolator without earth switch (Motorized)
Complete cleaning of disc insulators for all phases by suitable liquid cleaner, testing of IR value by insulation tester, making series connection & ready for hoisting with all cost of men, T & P consumables etc.
132 KV side single insulator string
Stringing of various main, buses of 132 KV with different type conductor and different length of span as mentioned below .the work includes cutting &bending of conductor fixing of single /double bolted type tension fitting /suspension hoisting of disc Insulator and shifting of material from store .site to erection site and all other associated work to complete work satisfactorily as per drawing and technical specification.
132 KV Main Bus-II of Twin Moose conductor
132 KV Jumper of single Moose conductor.
132 KV Jumper of Twin Moose conductor.
Stringing of 132 KV string under Beam to pass the jumper including dismantling of disc insulator and suspension fitting complete with all work.
Earthing of equipment’s by cutting straightening, bending, laying 700mm below ground and above ground of following size of MS flat for earthing of main and auxiliary structure, equipment’s structure. Transformer body and its neutral point including welding with main earthmat and with object to be earthed excavation of trenches its back filling. All other associated work as required to complete the work.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Painting of MS flat of different size after cleaning of rusted surface 1st coat of Red Oxide and 2 coat of Bus Green Paint to complete the work.
MS Flat of size 75x10 mm
MS Flat of size 50x6 mm
MS Flat of size 25x6 mm
Supply portion :-
Bolted type Tension fitting for Twin Moose Conductor with turn buckle suitable for 1x10 No Disc insulator complete with hardware set as per technical specification.
Bolted type Tension fitting for Twin Moose Conductor without turn buckle suitable for 1x10 No Disc insulator complete with hardware set as per technical specification.
Bolted type Suspension fitting for Twin Moose conductor suitable for 1x10 No Disc insulator with hardware set as per technical specification.
04 Bolted Type PG clamp suitable for Moose to Moose conductor Complete with HDG nut bolt & washer as per technical specification.
132 KV P.T clamp suitable for Twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
Spacer for 100mm spacing for Twin Moose Conductor 02 Bolted completed with hot dip galvanized nut, bolts & washer as per technical sepecification.
Spacer for 250mm spacing for Twin Moose Conductor 02 Bolted completed with hot dip galvanized nut, bolts & washer as per technical sepecification.
132 KV Bus Isolator clamp twin Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
132 KV Bus Isolator clamp Single Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
Erection of Main & Auxiliary S/S Structure for new 63 MVA T/F Bay
Proper stacking and shifting of Main & auxiliary structure in open switchyard at erecting place as per shop bill norms.
Erection of Main & Auxiliary structure lattice type ATM, ABL, BCT, ALP, BPL etc. consisting of column, beam, peak, mast etc. and auxiliary structure for installation of isolator, CTs, PTs, LA etc. erection of structure as per drawing with the help of GI nuts & Bolts flat spring washer matching the hole, cutting and matching the member if required include cost of all men and T & P excluding GI structure nut and bolts to complete the work erection of main & auxiliary structure lattice type ATM, BTM, AXM, ABL, CCM,CGM, EKR, BBR, BCT, ALP, BPL, BTI etc. upon foundation and its proper tightening.
Making hole in part of GI Main/auxiliary structure / cutting of GI angle drilling of hole existing/ defective structure /plate/Angle and grinding machine with all cost of men, T & P etc.
Erection of following equipment as per instruction manual of various equipment’s and technical specification including shifting of material / equipment from store to erection site including all other associated works to complete the job satisfactorily.
Erection of 145 KV SF-6 Circuit Breaker
Erection of 145 KV Current Transformer
Erection and mounting of 145 CT junction box.
Erection of 145 KV Tandom Isolator without earth switch (Motorized)
Erection of 145 KV Bus Isolator without earth switch (Motorized)
Erection of 120 KV Lighting Arrestors
Erection of 36 KV Vacuum Circuit Breaker
Erection of 36 KV Current Transformer
Erection of 36 KV Bus Isolator.
Erection of 30 KV Lighting Arrestors
Erection of 33 KV Post Insulator
Erection of following control and relay Panels as per instruction manual and technical specification including shifting of panel from store to erection site including all other associated works to complete the job satisfactorily.
Erection of 132 KV control relay panel for 63 MVA Transformer.
Erection of LT out door cubical for LT supply
Erection of 63 MVA RTCC Panel.
Complete cleaning of disc insulators for all phases by suitable liquid cleaner, testing of IR value by insulation tester, making series connection & ready for hoisting with all cost of men, T & P consumables etc.
132 KV side single insulator string
Stringing of various main, Transfer bus bar and jack buses of 132 KV & 33KV different type conductor and different length of span as mentioned below the work includes cutting &bending of conductor fixing of single Panther bolted type tension fitting /suspension hoisting of disc Insulator and shifting of material from store site to erection site and all other associated work to complete work satisfactorily as per drawing and technical specification.
132 KV Jack Bus for 63 MVA Transformer
Hoisting of 132 KV string under Beam to pass the jumper including hanging of disc insulator and suspension fitting complete with all work.
Stringing of various main, Transfer bus bar and jack buses of 132 KV & 33KV different type conductor and different length of span as mentioned below the work includes cutting &bending of conductor fixing of single Panther bolted type tension fitting /suspension hoisting of disc Insulator and shifting of material from store site to erection site and all other associated work to complete work satisfactorily as per drawing and technical specification.
63MVA Transformer Bay 132 KV side Jack Bus for Single Panther.
33 KV side Transformer bay Twin Zebra/ Twin Moose
Laying and Termination of following size control cable in trench/cable trays from different control room equipment to 132/33 KV Isolator, circuit breakers CT/PT & their junction boxes. Transformer marshaling box. Isolator box & other outdoor equipment’s installed in 132/33 KV switch yard as per cable schedule. Including carriage of cable drum from store and all other associated work.
Control cable of size 2 core x 2.5 mm2
Control cable of size 4 core x 2.5 mm2
Control cable of size 6 core x 2.5 mm2
Control cable of size 10 core x 2.5 mm2
Termination of control cable
Laying & Termination of following size PVC power cable from ACDB /DCDB installed on control room / 33/.04 KV station Transformer marshaling box etc. in 132/33 KV switchyard in side 500mm below ground level including excavation of trench & laying on its edge along with cable of both side filling the same with Ganga sand and then putting the bricks on 115mm side cover the trench & then filling with earth. Proper termination at both side by providing crimping type aluminum lugs as per requirement including cost of bricks sand cable route marker as per cable schedule including carriage of cable drum from store and all other associated works.
Power cable 31/2 core x 300 mm2 /150 mm2
300 mm2 Power cable termination.
Fabrication of 3 meter long electrode with 40 mm dia M S round bar having 150 mm long conical shape by digging cutting, straightening etc. and then placing it vertical. inside the ground with Top 700mm below the ground level including shifting of MS round bar from storage place at the Sub-Station to switchyard.
Delta earthig of 120/33 KV LA's of 132 KV Lines and 63 MVA Transformers neutral by consisting of 3/6 Nos. 3.0 Mtr long electrode of 40mm dai having 150mm long conical shape, its placing inside the ground in rectangular/triangular shape and connection all 3/6 Nos electrodes with 75x10/50x6mm MS flite laid on its edge and then this rectangle/tringle shape be connected to main earth mat at two place in opposite direction strictly as per drawing.
120 KV Lighting Arrestors (Rectangle shape 6 electrode )
30 KV Lighting Arrestors (Rectangle shape 6 electrode )
Earthing of equipment’s by cutting straightening, bending, laying 700mm below ground and above ground of following size of MS flat for earthing of main and auxiliary structure, equipment’s structure. Transformer body and its neutral point including welding with main earthmat and with object to be earthed excavation of trenches its back filling. All other associated work as required to complete the work.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Painting of MS flat of different size after cleaning of rusted surface 1st coat of Red Oxide and 2 coat of Bus Green Paint to complete the work.
MS Flat of size 75x10 mm
MS Flat of size 50x6 mm
MS Flat of size 25x6 mm
Periphery and switchyard lighting
Providing and fixing of half round GI pipe OD-50mm for mounting the 120 Watt LED light upon gantry mounting of 2 No GI bracket up on gantry and fixing GI pipe complete with nut bolt and washer as per technical specification.
Providing and fixing of junction box on gantry structure with 1 No MS flat 40x5 mm of size 200x200x150 mm made of MS sheet of 16 gauge dully powder coated inside mounting 1 No 6 Amp MCB 1 No TB of 4 terminal & 1 No Kit Kat 16 Amp fixed upon mica sheet and back side mounting a flat 40x5 mm with 1 No 16mm dia hole and mounting PVC pipe from ground level to box as per technical specification.
Supply & fixing of new generation energy saving and environment friendly long life versatile pressure die cost aluminum out door high been flood light with high power 120 Watt LED as light source and exclusively designed polycarbonate cover along with electronic driver complete fitting suitable for 220 V input supply for ISI make CGL/Hevels/ Surya/ Philips/Bajaj of equivalent etc. including electrical connection also to be done by the contractor.
Supply portion :-
Bolted type single Tension fitting for Panther Conductor suitable for 1x10 No Disc insulator complete with hardware set as per technical specification.
Bolted type single Suspension fitting for single Panther conductor suitable for 1x10 No Disc insulator with hardware set as per technical specification.
3 Bolted Type PG clamp suitable for Panther to Panther conductor Complete with HDG nut bolt & washer as per technical specification.
4 Bolted Type PG Clamp suitable for Moose to Moose conductor complete with HDG nut bolt & washer as per technical specification.
Bimetallic terminal connector for 63MVA T/F HV side bushing rod 30 mm dia made of aluminum alloy LM-6 suitable for ACSR Zebra /Moose conductor of matching with bushing rod complete with hot dip galvanized nut & bolts as per technical specification.
Bimetallic terminal connector for 63MVA T/F LV side bushing rod 30 mm dia made of aluminum alloy LM-6 suitable for Twin Zebra /Moose conductor matching with bushing rod complete with hot dip galvanized nut & bolts as per technical specification.
132 KV Bimetallic CT clamp made of aluminum alloy LM-6 for Zebra/Moose conductor with HDG nut & bolts and washer as per Technical specification.
132 KV Tandom Isolator clamp suitable for Zebra/Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
132 KV Circuit Breaker clamp suitable for Zebra /Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
132 KV LA clamp suitable for Zebra/ Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
132 KV P.T clamp suitable for Zebra/ Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
33KV Bus post clamp suitable for Twin Zebra/Moose conductor complete with hot dip galanized nut bolts & washer as per technical sepecification.
33 KV LA clamp suitable for Twin Zebra/ Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
33 KV Bimetallic CT clamp made of aluminum alloy LM-6 for Twin Zebra/Moose conductor with HDG nut & bolts and washer as per Technical specification.
33 KV Circuit Breaker clamp suitable for Twin Zebra /Moose conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
Bimetallic terminal connector for 63 MVA T/F nuetral bushing clamp, rod 30 mm dia made of aluminum alloy LM-6 suitable for Twin Zebra /Moose conductor matching with bushing rod complete with hot dip galvanized nut & bolts as per technical specification.
33 KV LA clamp suitable for Panther conductor complete with hot dip galvanized nut, bolts and washer as per technical specification.
Spacer for 100mm spacing for Twin Moose Conductor 02 Bolted completed with hot dip galvanized nut, bolts & washer as per technical sepecification.
M/S JAI SHREE ENTERPRISES
Madan contractors & Co.
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .