Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹17.2 L+₹2.2 L (14.5%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹17.9 L+₹2.9 L (19.5%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹18.3 L+₹3.3 L (21.9%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹19.8 L+₹4.8 L (31.7%)Rejected-Finance | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
1 Mar 2022, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REP/REPLACEMENT OF PANEL INTERNAL CONTROL CABLES MCCBS CONTRACTORS TIMERS ARMOURED CABLES INTERNAL WIRINGS INCLUDING FITTING FIXTURES SWITCHES DBS MCBS SECURITY LIGHTS GATE LIGHTS WITH CONNECTED ACCESSORIES AND ALLIED WKS OF EMII INSTALLATIONS AT NSK
2022_MES_505510_1
8479/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NW KARANJA
REP/REPLACEMENT OF PANEL INTERNAL CONTROL CABLES MCCBS CONTRACTORS TIMERS ARMOURED CABLES INTERNAL WIRINGS INCLUDING FITTING FIXTURES SWITCHES DBS MCBS SECURITY LIGHTS GATE LIGHTS WITH CONNECTED ACCESSORIES AND ALLIED WKS OF EMII INSTALLATIONS AT NSK
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹60,000
Yes
9 Mar 2022
3 Feb 2022
3 Mar 2022
3 Feb 2022
1 Mar 2022
17 Feb 2022
3 Feb 2022 - 17 Feb 2022
Amount
Taking down and dismantling existing street Light/ Flood Light / post lantern / Garden light/ tube light fittings any type any wattage for repair or replacement of burnt /worn out accessories and refixed in position after repair all as directed. Note :- (i) Accessories only wherever required shall be measured and paid seperately as supply only. (ii) Labour charges for taking down and repair including minor spares like nuts, bolts , insulation materials & cleaning of area upto one mtr around the street light/ building lights/ Poles shall be deemed to be included in the rate .
Supply and fixing Pressure die cast aluminium housing LED street light luminaires with IP66 of 35/45 Watts . Make Bajaj Cat Part No BRTFG45 W or equivalent in CG/Havells.
Supply and fixing Pressure die cast aluminium housing LED street light luminaires with IP66 of 90 Watts . Make Bajaj Cat Part No BRTFG90 W or equivalent in CG/Havells.
Supply and fixing Pressure die cast aluminium housing LED street light luminaires with IP66 of 120 Watts . Make Bajaj Cat Part No BRTFG120 W LED I or equivalent in CG/Havells.
S & F LED floodlight luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series ,120Watt & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. Make : Bajaj Cat ref No BARFEG160W LED or equivalent in C&S /Philips.
Supply and fix LED drivers suitable for 120Watt flood/ Street light light fitting complete with all accessories as specified and directed by engr-in-charge.Make Bajaj equivalent in C&S/PHILIPS
Supply and fix LED drivers suitable for 90Watt Street light fitting complete with all accessories as specified and directed by engr-in-charge.Make Bajaj or equivalent in C&S/PHILIPS .
Supply & Fix in repair bracket for street light fittings made out of 40 mm bore medium grade GI tubing 1.2 m long bent to shape and including suitable size of MS clamps, nuts, bolts and washers applying two coats of aluminium paint over a coat of red oxide zinc chrome primer repair complete all as specified and directed.
Taking out cable loop after necessary excavation , cutting the burnt out damage end of cable ,refixing the cable providing suitable size of brass cable gland and copper lugs complete with all necessary connection with the existing system and refilling of excavated soil making finishing with the existing ground surface for the following sizes:-
(a) 4 core 16 Sqmm
(b) 3.5 core 25 Sqmm
(c) 3 core 35 Sqmm
(d) 3 core 50 Sqmm
(e) 3 core 95 Sqmm
(g) 3 core 120 Sqmm
Supply and connect twin core PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm drawn through existing pipe complete all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
M & L earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point all as specified and indicated including testing on completion
S&F double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 12 way double door open able, including taking out old unsv MCB DB any size/type.
S&F double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 8 way double door open able, including taking out old unsv MCB DB any size/type.
S&F 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series). Make L &T , Havells, Legrand, HPL, BCH or equivalent
S&F 6 to 32 AMP MCB SPN 240 V 10 KA (C-Series). Make L &T , Havells, Legrand, HPL, BCH or equivalent
S&F 40 to 63 AMP MCB SPN 240 V 10 KA (C-Series). Make L &T , Havells, Legrand, HPL, BCH or equivalent
Supply and fix in repairs power contactor 3 pole, type MNX- 80, with standard coil voltage 240 volts, rating 100 Amp of make M/s L & T or equivalent in Havells / Siemens all as specified and directed.
Supply and fix in repairs power contactor 3 pole, type MNX-110, with 2 NO + 2 NC aux contacts with standard coil voltage 240 volts, rating 160 Amp of make M/s L & T or equivalent in Havells / Siemens all as specified and directed.
Supply and fix in repairs power contactor 3 pole, type MNX-140, with 2 NO + 2 NC aux contacts with standard coil voltage 240 volts, rating 160 Amp of make M/s L & T or equivalent in Havells / Siemens all as specified and directed.
Supply and fix in repairs on-off push button pendants with elements red/green/orange type of make MIMIC/ M/s L&T / M/s Siemens all as specified and directed.
Supply and fix in repairs indication lamp of make M/s L & T or equivalent make of M/s Siemens all as specified and directed.
Supply and fix in repairs MCB TP, 415 Volts, 50 Hz, 10 KA conforming to IS 8828 of rating 25-63 Amp of Make-M/s Havells/M/s Siemens / M/s Legrand/M/s L&T
Supply and fix in repairs MCB TPN, 415 Volts, 50 Hz, 10 KA conforming to IS 8828 of rating 16-32 Amp of Make-M/s Havells/M/s Siemens / M/s Legrand/M/s L&T
Supply and fix in repairs MCCB TP, 415 Volts, 50 Hz, 25 KA conforming to IS 8828 of rating 100 Amp of Make-M/s Havells/M/s Siemens / M/s Legrand/M/s L&T
Supply and fix in repairs MCCB TP, 415 Volts, 50 Hz, 36 KA conforming to IS 8828 of rating 160 Amp of Make-M/s Havells/M/s Siemens / M/s Legrand/M/s L&T
Supply and fix in repairs MCCB 3 Pole , 415 Volts, 50 Hz, 36 KA conforming to IS 8828 of rating 250 Amp of Make-M/s Havells/M/s Siemens / M/s Legrand/M/s L&T
Supply and fix in repairs MCCB 4 Pole , 415 Volts, 50 Hz, 36 KA conforming to IS 8828 of rating 250 Amp of Make-M/s Havells/M/s Siemens / M/s Legrand/M/s L&T
Supply and fix in repairs MCCB 4 Pole , 415 Volts, 50 Hz, 36 KA conforming to IS 8828 of rating 400 Amp of Make-M/s Havells/M/s Siemens / M/s Legrand/M/s L&T
Supply and connect Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 6 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
Supply and fix LED batten with 20W LED tube light in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with .as directed and specified by engr-in-charge.Make Bajaj BCLSB 20WH or equivalent in CG/Havells
Supply, laying and testing Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 10 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete including fixing with Copper Lugs of suitable size all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
Supply, laying and testing Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 16 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete including fixing with Copper Lugs of suitable size all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
Supply, laying and testing Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 35 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete including fixing with Copper Lugs of suitable size all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
Supply, laying and testing Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 95 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete including fixing with Copper Lugs of suitable size all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
Supply, laying and testing Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 120 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete including fixing with Copper Lugs of suitable size all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
Supply, laying and testing Single core PVC insulated multistranded 1100 volt grade copper conductor cable of size 150 sqmm single runs drawn through existing pipes/ Floor/trench/wall complete including fixing with Copper Lugs of suitable size all as specified and directed. Make : Polycab/ Havells/ Anchor/ HPL or equivalent
M & L for 2 mm thick mild steel sheet metal work in electric panel doors, bus bar covers and accessories mounting supports for alignment with front door including necessary cutting, welding etc with and including two coats of synthetic enamel paint in grey colour over one coat of red oxide zinc chrome primer as in repairs complete all as specified and directed
M & L for replacement of base of LT panel board made out of mild steel medium channel of size MC-75 and equal angle of size 45 mm x 45 mm x 6 mm thick including necessary cutting, welding etc with and including two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer as in repairs complete all as specified and directed
S & F Direct on line starter in sheet metal enclosure, Type MN/ML, Relay range 9-15 Amps, suitable for 10 HP/7.5 KW induction motor, 415 Volts, 50 Hz, 3 Phase Make- L&T or equivalent of M/s Simense and M/s GEC all as specified and directed.
S & F Direct on line starter in sheet metal enclosure, Type MN/ML, Relay range 14-23 Amps, suitable for 15 HP/11 KW induction motor, 415 Volts, 50 Hz, 3 Phase Make- L&T or equivalent of M/s Simense and M/s GEC all as specified and directed.
S & F Fully automatic star delta starter in sheet metal enclosure, Type MN-110 FASD, Relay range 66-110 Amps, suitable for 150 HP/110 KW induction motor, 415 Volts, 50 Hz, 3 Phase Make- L&T or equivalent of M/s Simense and M/s GEC all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.all as specified and directed by Engr -in- Charge.
M.K Enterprises
R A Electric Co.
Om Sai Enterprises
D.N.PATIL
somnath engineering corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .