Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹40.4 LAccepted-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹41.6 LRejected-Finance | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹42.3 LRejected-Finance | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FORTH₹49.4 LRejected-Finance | FORTH | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Dec 2023, 6:00 pmClosed
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
ADDN/ALTN TO MT SECTION AT ASTE AND OTHER SANCTIONED WORKS UNDER GE AF MARATHAHALLI BANGALORE
2023_MES_629280_1
8657/E8
Open Tender
Civil Works
Works
180 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹90,000
Yes
7 Feb 2024
21 Nov 2023
23 Dec 2023
21 Nov 2023
18 Dec 2023
5 Dec 2023
Amount
Demolition of brickwork or stone/ boulder masonry, built in cement mortar , incl all quions, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
M & L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface all as specified.
Material and labour for 100 mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in sub base to flooring complete all as specified and directed.
Material and labour for 40mm thick PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in floors and finished even and smooth without using extra cement etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 m in depth, getting out in hard/dense soil etc., including trimming bottom and sides of trenches, leveling/grading and ramming bottom of excavation complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in soft/loose soil, complete all as specified and directed.
Removing debries/excavated/ demolished materials to a distance exc 1.5 KM but n.exc 5 KM and depositing where directed at a level n. exc 1.50 meter above the starting point all as directed.
M&L for concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete all as specified and directed.
Material and Labour for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, mud stops, benching, water tank platform etc.on roof, chajja weathering, slightly rounded or chamfered angles and throating etc. including necessary form work complete as directed.
M&L for Cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) of 75mm thick as in plinth protection complete all as specified and directed .
Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width 1:3:6 Type C-1(20 mm graded crushed stone aggregate ) and setting in mortar cement mortar 1:6, complete.
Rendering 5mm thick cement plaster in cement mortar 1:3 on ceiling including finished even and smooth without using extra cement, complete.
Rendering 10mm thick cement plaster in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in patches in cement mortar in 1:4 on fair faces of brick work or concrete surfaces even and smoothe without using extra cement.
M & L for 40mm thick Damp proof course in cement concrete 1:2:4 Type B-0 to horizontal surfaces including necessary form work all as specified. (Note : water proofing compound to be measured and paid for separately).
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. Rough finished surfaces of concrete, complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, Flat, not exc 200mm thick, Rough finished surfaces of concrete, complete all as specified and directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide etc. Rough finished surfaces of concrete, complete all as specified and directed.
M&L for RCC M-25 in Beams cantilevers, bressummers, lintels over 1.5m span, etc. complete all as specified and directed. Note : The design mix report shall get approved with GE by the contractor and the cost of the same shall borne by the contractor. No extra cost shall be admissible on this account.
M&L for RCC M-25 in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc. complete all as specified and directed. Note : The design mix report shall get approved with GE by the contractor and the cost of the same shall borne by the contractor.No extra cost shall be admissible on this account.
S & F mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. etc. complete all as specified and directed.
M&L for mild steel TMT bar 6mm to 8mm dia. cut to length, bend to shape required including cranking, bending spirally for hooping ends and binding with and including MS wire not less than 0.9 mm dia, etc. complete all as specified and directed.
M&L for mild steel TMT bar 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders. cut to length, bend to shape required including cranking, bending spirally for hooping ends and binding with and including MS wire not less than 0.9 mm dia, etc. complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding including backing / plaster / Screed and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Eng-In- Charge.
M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar 1:4 etc complete all as specified.
M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc.. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering on brick work or concrete surfaced wall as backing coat of cement mortar 1:3 all as specified.
Taking down, plastering from Roof surfaces and vertical surfaces including removal of existing roof treatment, cleaning, hacking for key scrubbing down with water, and removal of debries out side MoD land /Unit area without any extra cost etc. complete all as specified and directed. Note : Any damages occures to the electrical cable/Telephone cable/Signal cable or any cables laying on roof/Lightening protection strips fixed on the roof/ AC unit fitted on the roof/Anteena signal structure fitted on roof shall be rectified/repaired/ refixted by the contractor with in 24Hors without any extra cost complete all as specified and directed.
Demolition of unreinforced Cement concrete / Mud / Phuska / Concrete of any description over roof and in any position not other wise specifically provided etc all as specified and directed.
M&L for brushing neat cement slurry with 3 Kg of cement per sqm on old surfaces of roof all as specified and directed.
Removal of demolished Materials / Mud Phuska etc, of roof to a distance exc 1.50 km but not etc 5.0 Km / out side MoD / Unit area complete all as directed by Eng-In- Charge
M&L screed bed in cement mortar (1:3) 20 mm thick with using WPC as per manufactures instructions etc. on concrete surface as in required slope for draning out the rain water all as directed Note : WPC will paid separately.
M&L for 10mm thick rendering on roof and vertical surfaces in cement mortar 1:3 surface finished fair and even using WPC as per manufactures instructions complete all as specified. Note : WPC will paid separately.
Supply only water proofing compound conplast X 421 IC of FOSROC chemcial (Indian limted) or equivalent in Dr FIXITcomplete all as specified and directed.
Material and Labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in padding on roof complete all as specified and as directed.
M&L for labour for preparation of surface by removing dust, dirt and applying oil bound bitumen primer @0.20Kg/sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.0Kg/sqm reinforced with non woven polyester matt weighing not less than160gm/sqm having softening point not less than 150 degree centigrade, having tensile strength of 650N/sqcm and 350N/sqcm in longitudinal and transverse directions respectively of the reinforcement tearing strength of180N by torch application with minium 10cm side overlap and 15cm end lap, applying a coat of blown grade hot bitumin 90/15 over the membrane @ 1.2Kg/sqm and on drying apply a coat of solar reflective bituminous aluminium paint over membrane @ 0.1kg/sqm all as specified and directed by Eng-In-Charge.
Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc
S&F PVC (SWR) pipes of bore 110mm, single socketed in any length ( working pressure 6Kg/Sqcm) with rubber ring joints fixed to walls with MS clamps etc. complete all as specified.
S & F 110 mm bore of pipe PVC (SWR) bends of any radius / shoe fixed to PVC pipes as directed
Cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar exc half brick wall and n.exc one brick wall etc. and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified.
M&L for preparation of new surface/undecorated surfaces of ceilings and applying three coats of white wash, complete all as directed by Engr-in-Charge.
M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint including one coat of Birla white putty 1mm on plastered surfaces etc. complete all as specified.
M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified
M&L for Preparation of old surface of ceiling and applying one coat of white washing.
M&L for preparation of Old surface of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint including one coat of Birla white putty 1mm on plastered surfaces etc including complete removal of existing surfaces of any etc. complete all as specified.
M&L for preparation of old surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paint including complete removal of existing surfaces of any etc. complete all as specified
M&L for preparation of Old surfaces of walls and applying two coats of Plastic emulsion paint over a coat of priming on walls including complete removal of existing finishes etc. complete all as specified.
Preparation of old painted surface of wood and wood based surface any description not otherwise described over 10cm width or girth including knotting and stopping and all preparation work required and applying one coat of synthetic enamel paint all as specified.
Preparation of old painted surface of steel surface any description not otherwise described over 10cm width or girth including knotting and stopping and all preparation work required and applying one coat of synthetic enamel paint all as specified.
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (W/out taking off shutters from the frames).
S & F powder coated anodised alluminium frame for sliding doors, window, ventilators, partitions with one or more rebates including joining cleat for fixing and finished with metal paste on gaps of the surface in contact with stone masonry walls / brick walls complete all as specified and as directed by Engr-in-Charge.
S & F Powder coated anodised alluminium window and ventilator shutters sliding type without sash bar, aluminium sections weighing 0.55 Kg/m including joining cleats glazing clips, rubber packing , anodised aluminium snap beading, screws etc. complete all as specified and as directed by Engr-in-Charge.
Provision of 5.5 mm thick tinted glass exc 0.5 sqm of each pane of superior quality fixed to alluminium frame works with rubber beadings including solar control film of 25 micron reflective type sicked to glass panes as per instructions of manufacturers Complete all as specified and as directed by Engr-in-Charge.
S&F MS Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete all as specified and directed.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified.
Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
M&L for Brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified.
Supply and fixing of GI tubing, light grade, 50 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete. Make - TATA / ZINDAL / Bansal .
Supply and laying cable XLPE insulated armoured,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core connected with suitable legs including taking out the existing unserviceable cable
Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 mpa working pressure.
M&L for PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in foundations for filling and mass concrete complete all as specified and directed.
M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for One light point /Fan point/ bell point controlled by one switch.
Description all as per item No 63 bove but One 5 Amps socket point on same board with other switches
Description all as per item No 63 aboveOne 5 Amps socket point on independent board.
Description all as per item No 63 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board .
Material and Labour for ceiling rose 3 terminals complete all as specified & directed.
Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed
S & F modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed.
Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed
S & F modular socket 06/16 Amps 2/3 pin combined 2 module complete all as specified & directed.
S&F in repair S&F in repair LED PC batten light fitting of 4 feet 20 watt, with energy efficient LED and integrated electronic driver of 20W fitting including connecting up with three core flexible copper conductor upto ceiling rose complete all as specified and directed. Make : Bajaj /CG/Philips/Havells
S & F MCB SPN 40 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make -Havells or equivalent
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make -Havells or equivalent
S & F MCB DB SPN 8 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
S & F MCB DB SPN 4 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
S&F Celing Fan complete with blades , down rods ,elcetrinic regulator and acessories , 230 volts, 1200 mm sweep , min air delevery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed.
Supply and fixing of Endura Citylite Platinum, 35 W LED Street Light fittingpressure die cast aluminium housing, heat resistance toughened glass, IP-65/66 protection including with bracket made out of GI pipe 32 mm complete all as specified and directed.
M & L for sub main wiring complete with two runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
S&F S & F LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
M&L for point wiring with cable 1.5 Sqmm single core PVC insulated unsheathed 1100volts grade copper multi stranded conductor drawn through and including stove enamelled steel conduits for Flameproof wiring surface on wall roofs floors etc including conduit accessories/ fittings, screws, washers etc, to accomodate flame proof switches & plates including all cutting/chases etc in walls complete all as specified and directed.
Supply & fix switch flame proof rotary type with termination box in LM6 16A, single pole 250V with flame proof gland.
Supply and fixing Flameproof LED light fitting 16/20 Watt, CMRI certified recommended for gas/ vaporgroup of IIA & IIIB, Zone 1 & 2 and IP 65 protectionwith die cast aluminum hosing with heat resistanttoughened glass with LED tube light fixturesdriver,holders, connector etc. Complete with all accessoriesprewired and including connecting up with threecore flexible copper conductor cable with suitable size. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Demolition of PCC in ground floors & paving exc 15cm thickness (below or above GL), complete all as specified and directed by Eng-In-Charge.
M & L for 150mm bore Reinforced concrete pipes, class NP2, laid in road crossings and upto drains and jointed complete with collars , complete all as specified and as directed by Eng-In-Charge.
M&L for Pre-cast cement concrete block masonry with solid blocks, type B-1 1:2:4 (20mm graded aggregate) , laid in cement mortar (1:4) exc.10 cm in width and setting in mortar, complete all as specified and directed.
Rendering 15 mm thick on fair faces of brickwork or concrete surfaces CM (1:3) finished even and smooth with using extra cement with wpc complete all as specified and directed.
Providing, precast cement concrete 1:2:4 (20 mm graged aggregate) type B-1as in landing cover slab , water troughs, similar article , cover slab, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified and directed.
M & L for 100mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floors and pavings etc, finishing with spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green, complete all as directed by Engr-in-charge.
S&F PVC (SWR) 110mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as directed by Engr-in-charge.
S&F 110mm bore of pipe PVC (SWR) junction single, (Single T) equal or unequal with access door.
Removing building materials etc. to a distance of 5 Km out side MoD/Unit land including loading, unloading and stacking at the destination etc. complete all as direction of Engineer-in-charge,
Development of tube well with compressed air and after with 25% extra capacity pump pumping muddy water for 4 nos bore wells
Taking out and lowering GI pipe with new/repaired submersible pump set of any size (5 HP to 12.5 HP), 3 phase 400/415 Volts in 200/250 mm size tube well up to existing depth of bore comprising following nature of work. (a) Dis- connection existing pipe connection any size and removing electric connection. (b) Errection of trapord/chain pulley block at site . (c) Lowering the removed submersible pump with connected pipe,electric connection, testing after completion of work.
Excavation in trenches exceeding 1.5 meter but not exceeding 3.00 m depth and not exceeding 1.5 m in width, getting out in hard/dense soil etc., including trimming bottom and sides of trenches, leveling/grading and ramming bottom of excavation complete all as specified and directed.
Supply and spread and leveling graded coarse aggregate in loose filling over of guage 40 mm nominal size up to 60 cm height in Rain water harvesting well complete all as specified & directed.
Supply and spread and leveling graded coarse aggregate in loose filling over of guage 20 mm nominal size up to 60 inches height in Rain water harvesting well complete all as specified & directed.
Supply and spread and leveling graded coarse aggregate in loose filling over of guage coarse sand nominal size up to 60 inches height in Rain water harvesting well complete all as specified & directed.
Supply and spread and leveling graded coarse aggregate in loose filling over of guage fine sand nominal size up to 60 inches height in Rain water harvesting well complete all as specified & directed.
Supply and spread a netlon Mesh over sand nominal size for rain harvesting well complete all as specified & directed.
Supply and fix PVC class 'A' pipe 160mm bore conforming to IS 13592 including making holes to flow of water into the bore well complete all as specified & directed.
Dismantling of stone slab and tiles of any description or thickness in floors,aprons etc.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed in curvature, with self tapping screws as specified.complete all as specified and directed
S & F of Poly carbonate sheet 6mm thick as in clading with self type screws all as specified and directed.
S&F of Rolled mild steel in Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-290 Gde E-165) .complete all as specified and directed
M & L for Machine cut kota stone slab flooring 25mm thick over and including 20 mm thick cement screed bed in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for preparation of new steel surfaces of any description over 10 cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
B5BUILDING SOLUTIONS
Chandana Enterprises
M/S PANJUGULA SUDARSHAN REDDY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .