Loading…
Loading…
Tender Value
₹3.8 Cr
EMD Value
₹1.9 L
Closing Date
17 Apr 2026, 5:00 pmClosed
MR Yognarayan sahu(DFLT)
CE,DURG
Construction of Bhendra to Saja Road Length 2.70 K.M. including Bridges & Culverts. at Distt.- Balod (C.G.)
187862
NIT No. 1169/TC/EinC/PWD/25-26
RESTRICTED TENDER
WORKS
6 days
CE
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
7 documents required · 7 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE,DURG
DURG,CIRCLE
DIVISION BALOD
120
06
No
0
187862
17 Apr, 2026 5:00:00 PM IST
22 Apr, 2026 10:00:00 AM IST
27 Mar, 2026 5:00:00 PM IST
NIT No. 1169/TC/EinC/PWD/25-26
Construction of Bhendra to Saja Road Length 2.70 K.M. including Bridges & Culverts. at Distt.- Balod (C.G.)
190000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
37843000.00
2
21 Apr, 2026 5:00:00 PM IST
37843000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 16h 8m
7 documents required · 6 mandatory · 1 optional
₹0
₹1.9 L
25 Mar 2026
25 Mar 2026
22 Apr 2026
27 Mar 2026
17 Apr 2026
27 Mar 2026
21 Apr 2026
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material tobe used or auctioned up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant lauses of section- 200. In area of light jungle
Excavation in Soil (by Mechanical Means.)Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead upto 1000 meters as per relevant clauses of section 300.
Construction of Embankment with Material Deposited from Roadway Cutting (Construction of embankment with approved materials having C.B.R.>5 (unless specified otherwise in the contract) deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)
Compacting Original Ground Compacting Original Ground supporting embankment Loosening, leveling and compacting original ground to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at O.M.C. and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction .
Construction of RCC Drain/Cover/Chamber Excavation for drain (Earth work in excavation for drain/chamber as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
Construction of RCC drain/chamber cover, Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material ,carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method (with Mechanically crushed stone only) (b) For Sub-base cum drainage layer or upper sub-base with (i) Grading-V Material
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)
Providing and fixing guard stones 200 x 200 x 900 mm made of precast RCC M-20 grade fixed at 300 mm into the ground in P.C.C. 1:3:6 blocks of size 400 x 400 x 400 mm and given two coats of paint with white and black bands including excavation.
Prime coat (Providing and applying primer coat with oil based bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per clause 502. on WBM/WMM surface @0.85 Kg/sqm.
Tack coat Providing and applying tack coat with bitumen emulsion (RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. granular surfaces treated with primes @ 0.30 kg / Sqm
Bituminous Macadam (Providing and laying bituminous macadam as per clause 504 with mixed prepared in minimum 40-60 TPH capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction) (B)With mechanical paver finisher (ii) for Grading-II(19 mm nominal maximum size, bitumen content 3.40%)
Close Graded Premix Surfacing/Mixed Seal Surfacing (Mechanical means using minimum 40-60 TPH capacity of HMP. Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness using bitumen to the required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to required level and grade, complete as per clause 508) (II)With mechanical paver finisher (A)With bitumen (ii) Type B ( 13.2 mm to 0.09 mm size aggregates )
Painting on Concrete Surfaces Two coats on new surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) Ordinary Kilometer Stone(Precast)
Hectometer stone (Precast)
Providing & Fixing Hazard Marker Type-2 Partial Retro Reflective Size 0.30 x 0.90M made of 16 gauge (1.6 mm) thick mild steel sheet Confirming to IS:2062 Painted with one cast of Zinc Chromate Stoving Primer and two coats of Black Stove Enamel (Oven Baked) paint with 10 cm bands of yellow Retro- Reflective Sheeting of Engineering Grade pasted a per IRC:79 including one MS angle Iron post of size 50x50x5 mm of 1.65 meter long duly painted with synthetic enameled paint block including bolts and fixing the same in M-15 concrete black of size 30x30x30cm, including transportation etc. Complete.
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Up to 3 m depth
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe on first class bedding. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets). 600 mm dia
Plain cement concrete complete as per drawing and Technical Specifications PCC Grade M 15
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 meters and as per relevant clauses of section-200 in Lime / Cement Concrete Cement Concrete Grade M-15 & M-20
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including dewatering etc. complete. Ordinary soil Upto 3 m depth
Ordinary rock (not requiring blasting)
Add extra 20% in the rates of above items for dewatering (Assessment of dewatering shall be made as per site condition )
Sand Filling in Foundation Trenches as per Drawing & Technical Specifications.
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. Height Upto 5m Using concrete mixer PCC Grade M15
PCC Grade M20
RCC Grade M25
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600.
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 Height upto 5m Using concrete Mixer P.C.C. Grade M-20
Height upto 5m Using concrete Mixer R.C.C. Grade M-20
Height upto 5m Using concrete Mixer R.C.C. Grade M-25
Supplying, fitting and placing HSD (High Strength Deformed Steel) bars reinforcement in sub-structure complete as per drawing and technical specifications section 1600 and 2200.
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications section 2706 and 2200
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200. (i) Granular material
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MORT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications 710.1.4 of I.R.C. 78 and 2200.
Providing and fixing in position tar paper bearing for slab as per approved drawings and specification.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification sections 1500, 1600 and 1700 RCC Grade M30 For Solid Slab Super Structure Using Concrete Mixer Height upto 5m
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications as per relevant clause of section 2700.
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. (vide drawing No. SD/201, SD/304)
Drainage Spouts complete as per drawing and Technical specifications of section 2705
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification and as per relevant section 2700
Providing and laying M-30 grade Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification and as per relevant sections 1500, 1600, 1700 and 2704
Filler joint Providing & fixing 20 mm thick compressible fiber board (12 m long x 25 cm deep ) in expansion joint complete as per drawing & Technical Specification.
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications as per section 2504. Cement Concrete blocks of size 0.3x0.3 x0.3 m cast in cement concrete of Grade M15
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification including trimming of slopes to proper profile and preparation of bed as per section 2504.
UOM Name
Percentage
Per mile
Siemens Per meter
Activity unit
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.07 MB
4355648977090759701_152305_9133295183868357873_125601_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
4459376305468423732_187862_Form A.docx
NIT • 0.07 MB
7004053889993316111_187862_NIT.docx
NIT • 0.12 MB
5864399783550166072_187862_Notice.docx
NIT • 0.04 MB
2659606985289369914_187862_BOQ.xlsx
BOQ • 0.05 MB
Download all tender documents and submit your bid