Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.1 CrAccepted-AOC 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹2.1 Cr | 1 | Accepted-AOC Lowest and reasonable |
| 2 | 2₹2.2 Cr+₹14.2 L (6.83%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | ₹2.2 Cr+₹14.2 L (6.83%) | 2 | Rejected-Finance Other than lowest |
| 3 | 3₹2.3 Cr+₹26.2 L (12.6%)Rejected-Finance | ₹2.3 Cr+₹26.2 L (12.6%) | 3 | Rejected-Finance Other than lowest |
| 4 | 4₹2.4 Cr+₹34.5 L (16.6%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹2.4 Cr+₹34.5 L (16.6%) | 4 | Rejected-Finance Other than lowest |
| 5 | 5₹2.6 Cr+₹50.3 L (24.2%)Rejected-Finance | ₹2.6 Cr+₹50.3 L (24.2%) | 5 | Rejected-Finance Other than lowest |
Tender Value
₹2.5 Cr
EMD Value
₹3.3 L
Closing Date
29 Jul 2021, 6:00 pmClosed
CWE Mhow
HQ CWE Mhow Cantt Mhow Mhow 453441
AUGMENTATION OF ELECTRIC SUPPLY AT MHOW
2021_MES_443724_2
CWE(MHOW)/05(T) OF 2021-22
Open Tender
Civil Works
Item Rate
270 days
HQ CWE Mhow
Please refer tender documents
8 documents required · 8 mandatory
₹2,000
GE (M) Inf School Mhow
₹3.3 L
27 Oct 2021
13 Jul 2021
31 Jul 2021
13 Jul 2021
29 Jul 2021
22 Jul 2021
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in deep and getting out for laying of cable/ pipes etc including forming bottom surfaces to the required level/slope complete all as specified and directed
Excavating in trenches exc 1.5m wide but exc 1.5m and n exc 3.0m deep for foundation of poles strut/stays etc n exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning , filling in includiing spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in soil comlete all as specified and directed
Removing surplus excavated to a distance not exc 50 mtr and depositing where directed at level not exc 1.5mtr above the starting point complete allas specified and directed.
Material and labour for approved river sand cushioning for under ground cable in trenches 8 cm before laying and 15cm after laying of cable and punned thickness of sand shall be measured and paid for 18 cm only after punned /consolidated thickness complete all as specified and directed
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type-2, flat, size 450mm x 180mm x 40mm, ISI marked, laid flat across the cable length for cable protection embossed with HT 11 KV electric on the top surface complete all as specified and directed. (Make: Mahtab tiles / Alankar Tiles/Pearlers Industries/SIND Mozaic Gujrat/JJ Concrete Lucknow).
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type-1, flat, size 250mm x 150mm x 40mm, ISI marked, laid flat across the cable length for cable protection embossed with LT 1100 Volts electric on the top surface complete all as specified and directed.(Make: Mahtab tiles / Alankar Tiles/Pearlers Industries/SIND Mozaic Gujrat/JJ Concrete Lucknow).
M&L for PCC (1:4:8), type D2, using 40mm graded stone aggregate in foundations of poles, filling and mass concrete including form work if required complete all as specified and directed.
M&L for PCC (1:3:6), type D2, using 20mm graded stone aggregate in coping of poles with & including necessary use & waste of form wk for fair finished surfaces complete all as specified and directed.
S & F Cable route indicator /marker made up of PCC block in cement mortar 1:3:6 (20mm graded stone aggregate) of size 900mm x 300mm x 100mm thick with "DANGER/11 KV CABLE/MES or DANGER/11 KV HT JOINT/MES" embossing on cable route indicator/marker including painting as per approved colour and burried in griund 45 cms including necessary earthwork (as required/ordered at site) complete all as directed.
S & F Cable route indicator /marker made up of PCC block in cement mortar 1:3:6 (20mm graded stone aggregate) of size 900mm x 300mm x 100mm thick with "DANGER/LT CABLE/MES " embossing on cable route indicator/marker including painting as per approved colour and burried in griund 45 cms including necessary earthwork (as required/ordered at site) complete all as directed.
Material and Labour for boring holes under the road/pavement/hard standing with the help of trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 100mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as specified and directed. (The cost of HDPE pipe shall be deemed to be included in quoted rate).
Supply and laying Galvanised iron pipe "light grade" with all fittings for passing of cabes fixed to pole/wall/laid under floor or roads including all fixing accessories complete for protection of cable of fllowing sizes of dia bore complete all as specified and directed.
100 mm dia
80mm dia
50 mm dia
40 mm dia
25 mm dia
20 mm dia
Supply , laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) conforming to latest relevant IS with multy stranded aluminium conductor, 11000 volts grade of size 3 core 95 mm cable laid in trenches/ducts/under plinth floor passing through pipe etc, fixed on wall complete all as specified and as directed.
Supply and fix cable jointing kit for 11 kV grade cable for outdoor termination, cold shrink type, joint complete with joining material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 95 sq mm complete all as specified and as directed.
Supply and fix cable jointing kit for 11 kV grade cable for indoor termination, cold shrink type, joint complete with joining material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 95 sq mm complete all as specified and as directed.
Supply and fix cable jointing kit for 11 kV grade cable for straight through, cold shrink type, joint complete with joining material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 95 sq mm complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size :-
185 Sqmm x 3.5 core
120 Sqmm x 3.5 core
95 Sqmm x 3.5 core
70 Sqmm x 3.5 core
50 Sqmm x 3.5 core
35 Sqmm x 3.5 core
25 Sqmm x 4 core
16 Sqmm x 4 core
10 Sqmm x 4.0 core
Supplying, installation and erection in true vertical position steel tubular swagd poles welded for provision of 2 pole structure complete with MS base plate 6mm thick and of size 300mm x 300mm, final taper, pole cap, bolts, nuts, washers & screw etc pole made out of ERW MS tubing conforming to IS-2713 part-II type 410 SP-55 (11 meter long) including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coat coats of aluminium paint for exposed surfaces, and two coat of black bituminous paint for portion embedded in concrete painting with synthetic enamel paint (First grade/quality) black & White colour at lower portion of exposed pole starting from plinth block band of 1200mm height ( 4 Nos EACH STRIP OF 150 MM WIDTH), PAINTING POLE NO BY THE BLACK PAINT by stenciled letter/figures of 8 cm height complete all as specified and directed. ( Note :- Earthwork, cement concrete Wk, Cross arm etc will be measured and paid under relevant items.)
M&L for cross arms, bracings, supports, clamps and back plates etc fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for fixing light fittings and painting with aluminium/silver paint in two coats on one coat of red oxide primer complete all as specified and directed. Make of steel : SAIL, TISCO, RINL, Pushpak steel industries Pune.
Supplying installing, fixing, commissioning and testing of Air break gang operated triple pole switch out door type of capcity 200 Amps AC mechanically operated mounted on polymer based insulator and steel frame with operating mechanism worked from ground level and polymer based Drop-out fuse set (set of 3 Nos) mounted on insulator with steel frame with Expulsion fuse carries and fuse element upto 25 Amps complete with locking arrangements including pad lock with key complete suitable for 11 KV, HT 50 Hz complete all as specified and directed. (Make: Pactil, Alstom, Jaipuria brothers, BHEL).
Supply and fix lightening arrestor HT 11 KV, non linear resistor type conforming to IS-3070 (Part-I) 1993 complete, line discharge class -3, nominal discharge current 65 KA (Peak), 12 KV rated system, voltage peak value high current implus of 4/10 micro Sec wave shape 100 KA (Peak) assembly suitable for 11 KV , long duration discharge class-II with insulation level 28/75 KV and mounted on hot dip galvanised steel structure including all; clamps, nut, bolts and washers and connecting to earth with 4mm dia GI wire complete all as specified and directed. (Make : ELPRO / GE / Pactil)
Supply, installation, testing and commissioning of 11 KV Outdoor type RMU extensible IP54 floor mounted with internal copper bus bars, consisting of fixed type Motorised Vacuum Circuit Breakers-02 Nos as incomer, bus coupler -01 No and fixed type Motorised Vacuum Circuit Breakers-04 Nos as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple inter connections & sealed for life robotically for three sides and one side manual welded non magnetic / non ferrite / stainless steel tank Grade 304 of minimum 2.5 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 & 603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200 complete all as specified.(AWC Area) (Make: ABB/Siemens/ Schnieder, Areva)
The unit shall have front cable entry for case of installation. RMU should be complete with all accessories such as terminal boots, VPIS, cable supports all front cable terminations, mechanical indications ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC60120. The unit shall include the following with all necessary standard fitting required at site. RMU should be tested for an internal arc fault of 21KA for 1 sec as per IEC62271-200 and paint shade and thickness should be as per AIS 632 IS – 5 complete all as specified and as directed. The outer enclosure shall cover the full length of the switch gear, to ensure IP55 protection for full door covering of complete switchgear.
(a) 2Nos. Incomer & 4 Nos outgoing :- (i) 630A Vacuum Circuit breaker module for making and breaking of fault current along with Earth switch of full making capacity. (ii) Short time breaking current-21 KA/ 3 sec Making capacity-52.5 KA (iii) Internal ARC-21KA/1 sec (iv) Nominal operating gas pressure – 1.3(minimum) bar abs (v) Power frequency withstand voltage-28KV (vi) Impulse withstand voltage-75KV (vii) Outdoor Enclosure –IP54 (viii) Front covermechanism-IP2X (ix) Cable covers – 3X (x) Stored energy mechanism for motor operation -24VDC (xi) Cable box for front termination of the cable suitable upto 3 core 400 Sqmm, 11KV XLPE cable (xii) Operation counter (xiii) Self-powered microprocessor based relay (3 O/C & E/F) with RS485 port and with standard setting –ADR241S (xiv) Digital multifunction meter (A,V,KW,F,PF) with RS 485 port type Rishabh/ Elmeasure (not applicable for bus coupler VCB) (xv) Protection CT-50-100/1A, CI-5P10, 2.5VA burden (not applicable for bus coupler VCB) (xvi) Metering CT-50-100/1A, CI-10, 2.5 VA burden(not applicable for bus coupler VCB) (xvii)Suitable site replaceable cables bushings (xviii) Arc proof cable covers with self interlocking mechanism between doors, earth switch, disconnector &VCB (xix) Capacitive voltage indication fixed type system (xx) Mechanical indication for breaker ON, OFF,EARTH< TRIP, spring charged- discharged
b) Direct cable module -1 No :- (i) 630A vacuum circuit breaker module (ii) Short time current -21KA/3 sec (iii) Internal arc -21KA/1sec (iv) Nominal operation gas pressure -1.3(minimum) bar abs (v) Power frequency withstand voltage -28KV (vi) Impulse withstand voltage -75KV (vii) Outdoor enclosure –IP54 (viii) Front cover mechanism –IP2X (ix) Cable cover -3X (x) Stored energy mechanism for motot operation -24VDC (xi) Cable box for fornt termination of the cable suitable upto 3 core 400Sqmm, 11KV XLPE cable (xii) Suitable site replaceable cable bushings (xiii) Arc proof cable covers with self interlocking mechanism between doors, earth, switch, disconnector &VCB (xiv) Capacitive voltage indication fixed type system (xv) Mechanical indication for breaker ON, OFF, EARTH, TRIP, Spring charged - Discharged
(C) Bus Connected PT Unit-1No for Metering consisting of following :- (i) Type M: Air insulated metering module 12KV, 630A, 21 KA for 1 sec -3 voltage transformers of the ratio 11KV/V3/ 110 V/V3, 50 VA, class 1.0 with HT fuses von primary side and MCB on secondary side. (ii) 1 LED illumination (iii) 1 space heater with thermostat (iv) RYB phase indications (v) 1 no digital voltmeter (d) 2x12 V battery with battery charge with suitable burden for motor operation input 230V AC & output 24 V DC. (e) Capacitive voltage indication fixed type VPIS 9-15 KV (f) Necessary interlocking arrangement for safety and operations (g) One no. operation handle for manual operation (h) One no. manometer (i) Safety interlocks shall be provided as per relevant IEC/IS standards and manufacturers direction. (k) Above switchgear shall conform to all relevant IEC/IS standards (l) Manual operation of vacuum circuit breaker should be possible without dismantling the motor from RMU. The motor should be filled in such a way that it should not be outside front covers of RMU. (m) Operation and instruction manual with drawing -01 set
(n) All cable bushing should be replaceable type (o) Module should be accommodated as per manufacture design (p) RMU cable box shall be front accessible type to have easy access to protection and metering CTs. (q) Master trip relay, auxiliary relays for transformer fault (Buchhloz’s relay alarm trip, oil and winding temp - only for 2 nos outgoing VCB (r) 12 Window display for OTI, WTI, Buchollz, trip and alarm etc – only for 2nos outgoing VCB (s) Local remote switch (t) Hooter – 2nos (u) Auxiliary power supply – single phase auxiliary transformer-11KV/230V AC for input to battery charger (v) Connection between cables riser panel & coupler VCB shall be cable connected using touch proof kits and same shall be done by OEM only as per their recommended guidelines (w) Vacuum interrupter should be of same make. Cable box should be are proof with boiled door and interlocked with respective earthing switches Doors should be removable for case access to terminate cables.
NOTE :- Rate quoted by the firm for this item should include the cost of the following :- (i) PCC work/ any civil work for foundation required for errection of VCB and other accessories all as standard norms. (ii) contractor shall submit type test certificate to the Engg-in- charge/GEfor approval for placing the order. (iii) The contractor will be submitted the NABL accredited lab test reports of the RMU’s in original and the same shall be produced well before claiming RAR payment of the RMU. (iv) RMU shall be inspected by inspecting officer nominated by Accepting Officer for testing and inspection at manufacturers factory and all routine test pertaining to IS shall be carried out.
Supply, install, testing and commissioning of 11 KV Outdoor type RMU extensible IP54 floor mounted with internal copper bus bars, consisting of fixed type Motorised Vacuum Circuit Breakers-02 Nos as incomer, bus coupler -01 No and fixed type Motorised Vacuum Circuit Breakers-04 Nos as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple inter connections & sealed for life robotically for three sides and one side manual welded non magnetic / non ferrite / stainless steel tank Grade 304 of minimum 2.5 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 & 603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200 complete all as specified. (MIS Area) (Make: ABB/Siemens/ Schnieder, Areva)
The unit shall have front cable entry for case of installation. RMU should be complete with all accessories such as terminal boots, VPIS, cable supports all front cable terminations, mechanical indications ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC60120. The unit shall include the following with all necessary standard fitting required at site. RMU should be tested for an internal arc fault of 21KA for 1 sec as per IEC62271-200 and paint shade and thickness should be as per AIS 632 IS – 5 complete all as specified and as directed. The outer enclosure shall cover the full length of the switch gear, to ensure IP55 protection for full door covering of complete switchgear.
(a) 2Nos. Incomer & 4 Nos outgoing :- (i) 630A Vacuum Circuit breaker module for making and breaking of fault current along with Earth switch of full making capacity. (ii) Short time breaking current-21 KA/ 3 sec Making capacity-52.5 KA (iii) Internal ARC-21KA/1 sec (iv) Nominal operating gas pressure – 1.3(minimum) bar abs (v) Power frequency withstand voltage-28KV (vi) Impulse withstand voltage-75KV (vii) Outdoor Enclosure –IP54 (viii) Front covermechanism-IP2X (ix) Cable covers – 3X (x) Stored energy mechanism for motor operation -24VDC (xi) Cable box for front termination of the cable suitable upto 3 core 400 Sqmm, 11KV XLPE cable (xii) Operation counter (xiii) Self-powered microprocessor based relay (3 O/C & E/F) with RS485 port and with standard setting –ADR241S (xiv) Digital multifunction meter (A,V,KW,F,PF) with RS 485 port type Rishabh/ Elmeasure (not applicable for bus coupler VCB) (xv) Protection CT-50-100/1A, CI-5P10, 2.5VA burden (not applicable for bus coupler VCB) (xvi) Metering CT-50-100/1A, CI-10, 2.5 VA burden(not applicable for bus coupler VCB) (xvii)Suitable site replaceable cables bushings (xviii) Arc proof cable covers with self interlocking mechanism between doors, earth switch, disconnector &VCB (xix) Capacitive voltage indication fixed type system (xx) Mechanical indication for breaker ON, OFF,EARTH< TRIP, spring charged- discharged
b) Direct cable module -1 No :- (i) 630A vacuum circuit breaker module (ii) Short time current -21KA/3 sec (iii) Internal arc -21KA/1sec (iv) Nominal operation gas pressure -1.3(minimum) bar abs (v) Power frequency withstand voltage -28KV (vi) Impulse withstand voltage -75KV (vii) Outdoor enclosure –IP54 (viii) Front cover mechanism –IP2X (ix) Cable cover -3X (x) Stored energy mechanism for motot operation -24VDC (xi) Cable box for fornt termination of the cable suitable upto 3 core 400Sqmm, 11KV XLPE cable (xii) Suitable site replaceable cable bushings (xiii) Arc proof cable covers with self interlocking mechanism between doors, earth, switch, disconnector &VCB (xiv) Capacitive voltage indication fixed type system (xv) Mechanical indication for breaker ON, OFF, EARTH, TRIP, Spring charged - Discharged
(C) Bus Connected PT Unit-1No for Metering consisting of following :- (i) Type M: Air insulated metering module 12KV, 630A, 21 KA for 1 sec -3 voltage transformers of the ratio 11KV/V3/ 110 V/V3, 50 VA, class 1.0 with HT fuses von primary side and MCB on secondary side. (ii) 1 LED illumination (iii) 1 space heater with thermostat (iv) RYB phase indications (v) 1 no digital voltmeter (d) 2x12 V battery with battery charge with suitable burden for motor operation input 230V AC & output 24 V DC. (e) Capacitive voltage indication fixed type VPIS 9-15 KV (f) Necessary interlocking arrangement for safety and operations (g) One no. operation handle for manual operation (h) One no. manometer (i) Safety interlocks shall be provided as per relevant IEC/IS standards and manufacturers direction. (k) Above switchgear shall conform to all relevant IEC/IS standards (l) Manual operation of vacuum circuit breaker should be possible without dismantling the motor from RMU. The motor should be filled in such a way that it should not be outside front covers of RMU. (m) Operation and instruction manual with drawing -01 set
(n) All cable bushing should be replaceable type (o) Module should be accommodated as per manufacture design (p) RMU cable box shall be front accessible type to have easy access to protection and metering CTs. (q) Master trip relay, auxiliary relays for transformer fault (Buchhloz’s relay alarm trip, oil and winding temp - only for 2 nos outgoing VCB (r) 12 Window display for OTI, WTI, Buchollz, trip and alarm etc – only for 2nos outgoing VCB (s) Local remote switch (t) Hooter – 2nos (u) Auxiliary power supply – single phase auxiliary transformer-11KV/230V AC for input to battery charger (v) Connection between cables riser panel & coupler VCB shall be cable connected using touch proof kits and same shall be done by OEM only as per their recommended guidelines (w) Vacuum interrupter should be of same make. Cable box should be are proof with boiled door and interlocked with respective earthing switches Doors should be removable for case access to terminate cables.
NOTE :- Rate quoted by the firm for this item should include the cost of the following :- (i) PCC work/ any civil work for foundation required for errection of VCB and other accessories all as standard norns. (ii) contractor shall submit type test certificate to the Engg-in- charge/GE for approval before placing the order. (iii) The contractor will be submitted the NABL accredited lab test reports of the RMU’s in original and the same shall be produced well before claiming RAR payment of the RMU. (iv) RMU shall be inspected by inspecting officer nominated by Accepting Officer for inspection and testing at manufacturers factory and all routine test pertaining to IS shall be carried out.
Supply, install, testing and commissioning of 11 KV Outdoor type RMU extensible IP54 floor mounted with internal copper bus bars, consisting of fixed type Motorised Vacuum Circuit Breakers-02 Nos as incomer, bus coupler -01 No and fixed type Motorised Vacuum Circuit Breakers-03 Nos as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple inter connections & sealed for life robotically for three sides and one side manual welded non magnetic / non ferrite / stainless steel tank Grade 304 of minimum 2.5 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 & 603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200 complete all as specified. (MIS area) (Make: ABB/Siemens/ Schnieder, Areva)
The unit shall have front cable entry for case of installation. RMU should be complete with all accessories such as terminal boots, VPIS, cable supports all front cable terminations, mechanical indications ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC60120. The unit shall include the following with all necessary standard fitting required at site. RMU should be tested for an internal arc fault of 21KA for 1 sec as per IEC62271-200 and paint shade and thickness should be as per AIS 632 IS – 5 complete all as specified and as directed. The outer enclosure shall cover the full length of the switch gear, to ensure IP55 protection for full door covering of complete switchgear.
(a) 2Nos. Incomer & 3 Nos outgoing :- (i) 630A Vacuum Circuit breaker module for making and breaking of fault current along with Earth switch of full making capacity. (ii) Short time breaking current-21 KA/ 3 sec Making capacity-52.5 KA (iii) Internal ARC-21KA/1 sec (iv) Nominal operating gas pressure – 1.3(minimum) bar abs (v) Power frequency withstand voltage-28KV (vi) Impulse withstand voltage-75KV (vii) Outdoor Enclosure –IP54 (viii) Front covermechanism-IP2X (ix) Cable covers – 3X (x) Stored energy mechanism for motor operation -24VDC (xi) Cable box for front termination of the cable suitable upto 3 core 400 Sqmm, 11KV XLPE cable (xii) Operation counter (xiii) Self-powered microprocessor based relay (3 O/C & E/F) with RS485 port and with standard setting –ADR241S (xiv) Digital multifunction meter (A,V,KW,F,PF) with RS 485 port type Rishabh/ Elmeasure (not applicable for bus coupler VCB) (xv) Protection CT-50-100/1A, CI-5P10, 2.5VA burden (not applicable for bus coupler VCB) (xvi) Metering CT-50-100/1A, CI-10, 2.5 VA burden(not applicable for bus coupler VCB) (xvii)Suitable site replaceable cables bushings (xviii) Arc proof cable covers with self interlocking mechanism between doors, earth switch, disconnector &VCB (xix) Capacitive voltage indication fixed type system (xx) Mechanical indication for breaker ON, OFF,EARTH< TRIP, spring charged- discharged
b) Direct cable module -1 No :- (i) 630A vacuum circuit breaker module (ii) Short time current -21KA/3 sec (iii) Internal arc -21KA/1sec (iv) Nominal operation gas pressure -1.3(minimum) bar abs (v) Power frequency withstand voltage -28KV (vi) Impulse withstand voltage -75KV (vii) Outdoor enclosure –IP54 (viii) Front cover mechanism –IP2X (ix) Cable cover -3X (x) Stored energy mechanism for motot operation -24VDC (xi) Cable box for fornt termination of the cable suitable upto 3 core 400Sqmm, 11KV XLPE cable (xii) Suitable site replaceable cable bushings (xiii) Arc proof cable covers with self interlocking mechanism between doors, earth, switch, disconnector &VCB (xiv) Capacitive voltage indication fixed type system (xv) Mechanical indication for breaker ON, OFF, EARTH, TRIP, Spring charged - Discharged
(C) Bus Connected PT Unit-1No for Metering consisting of following :- (i) Type M: Air insulated metering module 12KV, 630A, 21 KA for 1 sec -3 voltage transformers of the ratio 11KV/V3/ 110 V/V3, 50 VA, class 1.0 with HT fuses von primary side and MCB on secondary side. (ii) 1 LED illumination (iii) 1 space heater with thermostat (iv) RYB phase indications (v) 1 no digital voltmeter (d) 2x12 V battery with battery charge with suitable burden for motor operation input 230V AC & output 24 V DC. (e) Capacitive voltage indication fixed type VPIS 9-15 KV (f) Necessary interlocking arrangement for safety and operations (g) One no. operation handle for manual operation (h) One no. manometer (i) Safety interlocks shall be provided as per relevant IEC/IS standards and manufacturers direction. (k) Above switchgear shall conform to all relevant IEC/IS standards (l) Manual operation of vacuum circuit breaker should be possible without dismantling the motor from RMU. The motor should be filled in such a way that it should not be outside front covers of RMU. (m) Operation and instruction manual with drawing -01 set
(n) All cable bushing should be replaceable type (o) Module should be accommodated as per manufacture design (p) RMU cable box shall be front accessible type to have easy access to protection and metering CTs. (q) Master trip relay, auxiliary relays for transformer fault (Buchhloz’s relay alarm trip, oil and winding temp - only for 2 nos outgoing VCB (r) 12 Window display for OTI, WTI, Buchollz, trip and alarm etc – only for 2nos outgoing VCB (s) Local remote switch (t) Hooter – 2nos (u) Auxiliary power supply – single phase auxiliary transformer-11KV/230V AC for input to battery charger (v) Connection between cables riser panel & coupler VCB shall be cable connected using touch proof kits and same shall be done by OEM only as per their recommended guidelines (w) Vacuum interrupter should be of same make. Cable box should be are proof with boiled door and interlocked with respective earthing switches Doors should be removable for case access to terminate cables.
NOTE :- Rate quoted by the firm for this item should include the cost of the following :- (i) PCC work/ any civil work for foundation required for errection of VCB and other accessories all as standard norns. (ii) contractor shall submit type test certificate to the English charge/GE for approval for approval for placing the order. (iii) The contractor will be submitted the NABL accredited lab test reports of the RMU’s in original and the same shall be produce well before claiming RAR payment of the RMU. (iv) RMU shall be inspected by inspecting officer nominated by Accepting Officer at manufacturers factory and all routine test pertaining to IS shall be carried out.
Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (MIS Area )
27.Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50mm x 50mm x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (MCTE Area )
Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (MCTE Area)
Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (MCTE Area )
Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (MCTE Area )
Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (MCTE Area )
Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (MCTE Area )
Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (MCTE Area )
34. Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1200mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (MCTE Area )
Supply and install automatic power factor correction (APFC) panel factory made of 350 KVAR capacity ready to use design confiring to relevant IS rated for short circuit rating of 50 KA, front openable and lockable by keys having lowers and air vent, gasket and totally vermin proof and suitable for 415/440 volts, 3 phase 50 Hz, AC and housed in elegant enclosure fabricated from minimum 3.00 mm thick CRCA sheet, anti corrosive costing to achieve power factor from 0.9 to 0.99 and finally powder coated in texture seimens gray RAL 7032 & as directed by Engineer in charge comprising of and including following including suitable size and length of copper conductor cable from main panel to APFC panel for connection as approved complete all as specified and directed :- (Make: Havells / ABB/L&T )
600 Amp capacity for pahse and neutral copper bus bar duly insulated with colour coaded heat shrinkable sleeves and mounted on suitable DMC/epoxy insulators.
A set of heavy duty capacitor type MPPH box type, 440 volts with output steps of 350 KVAR capacity capacitor bank in steps of with 8 steps (1 x 100 KVAR + 3 x 50 KVAR + 4 x 25 KVAR) in any configuration to accommodate all possible set ups.
MCB’s TP, ‘C’ series, 4151 volts, off sizes with required numbers and suitable ratings as per the capacity of capacitors
Thyristor switches shall be provided bor connecting/disconnecting the capacitor banks to the bus bar.
The APFC panel provided with two existing terminal and it is connected through GI strip 32 x 6mm size complete all as specified and directed.
Digital panel meter for current, voltage/frequency and power factor having programmable CT ratio and built in sector switch of size 96mm x 96mm, accuracy class-1, auxiliary support of 230 volts AC with SP MCB protected shall be provided.
All control wires shall be not less than 2.5sqmm multistandard copper conductor and properly bunched/ tied, ferruled for proper identification and crimpled with adequate size of lugs the cubicle will have a bottom support of channel of suitable size, duly coated with zinc metal coating. A detachable pre drilled gland plate of thickness 3.15 mm thick, cold zinc metal coated shall be provided with at the bottom for entry for armoured cable with adequate size of gland manufacturer name plate with feeder details and danger plate shall be provided as per directed.
Auxiliary contactor with required quantity of NO & NC
Auto/ manual switch-01 No.
Fuse for line protection as per requirement and as approved.
Indicator lamp LED based with lamp holder as per requirement and as approved.
Current transformer (CT) of ratio 250/5A measuring class accuracy 0.50 to 1. For capacitor panel.
MCCB 4 pole 400Amps, thermal magnetic type breaking capacity 50KA with microprocessor release with 8 step overload adjustability at 415 volts – 01 No (incoming).
Detuning reactor of suitable size shall be provided to maintain THD less than 7%.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25cm x 20 cm size complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate 600mm x 600mm x 6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised MS strip 32mm X 6 mm as earthing strip by means of bolts, nuts, check nut and washers of galvanised iron or steel at all joints as shown in Electrical Plate No-3 of SSR Part I including excavation and earth work in any type of soil, GI pipe 15 mm dia light grade protection pipe, chorcoal filling, common salt, PCC 1:3:6 type C-1 using 20 mm graded stone aggregate in chamber and RCC precast cover 60mm thick (1:2:4) type B-1 using 20mm dia graded crushed stone aggregate, reinforced with 8mm to steel bars @ 75 mm c/c both ways with MS handle 12mm dia, GI funnel and wire mesh, 20mm dia GI pipe medium grade for watering and connected to earth Test point including testing complete all as specified and directed. (Note :- Earth protection pipe & earthing strip upto and including 7.5m length is deemed included in unit rate quoted by the contractor
S & F galvanised iron strip of size 25mm x 4mm for earth contunity conductor complete all as specified and directed.
M & L Surface excavation not exceeding 30cm deep and averaging 15cm and getting out watering and removing surplus soil to a distance n. Exc. 50m and making good surface, complete all as specified and directed.
M & L for loose filling with aggregate of size 40mm graded stone aggregate of 20 cm thickness around at 2 poles HT structure complete all as specified and directed.
Material and labour for brick work with sub class 'B' modular bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and directed.
M & L rendering 10 mm thick in CM 1:4 on other than fair surface of brick or concrete wall surfaces finished even and smooth without using extra cement with water proofing compound complete all as specified and as directed.
Excavating in post holes (similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth , in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface, in soft/loose soil complete all as specified & directed.
M & L PCC 1:3:6 type C2 using 40mm graded aggregate as foundations , filling & mass concrete complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
Supply only for chain link MS galvanised fencing any size any type complete all as specified & directed.
M&L mild steel gate with framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified.
M & L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat red oxide complete all as specified and directed.
Supply and providing 50mm thick sand cushioning with dry clean sand below the paver block complete all as specified and directed.
S & F in repair anti-climbing device spikes type, fabricated out of MS Bars (round, square and flat) flat of size 50mm x6mm in two parts with 14 Nos 230mm long 12mm dia spikes sharpened edge and including nits, bolts washers and welding in two halves made to size and shape to suit the cross section of pole and including painting with two coats of first grade aluminium paint over one coat of red oxide primer including preparation of surfaces complete all as specified and directed.
Material and labour for machine pressed coloured precast (factory made) concrete interlocking paver block (glossy finished) any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, laid over compacted dry sand and jointed with gray cement slurry and pigment and sides of paver blocks grouted with and including PCC 1:2:4 type B-0 using 12.50mm graded crushed stone aggregate to make straight line complete all as specified and directed. (Note: Sand cushioning shall be measured and paid separately.)
Material and labour for cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in roof kerbs/coping/bed plates,benching on chajja & haunching or levelling course ilike including weathering slightly rounded/chamfered angles with & including necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregates) as in sub base of floor complete all as specified and directed.
Taking down existing unserviceable LT panel including discinnecting incomming & out going cable connections carefully all as specified and directed.
Dismantling/ Taking down existing overhead line ACSR conductor of any description complete all as specified and as directed.
Dismantling/ Taking down insulator, 11000 volts & 1100 volts of any description complete all as specified and as directed.
Dismantling/ Taking down existing cross arms of any description complete all as specified and as directed.
Dismantling/ Taking down existing 11 mtr long PCC/Steel tubular pole of any description complete all as specified and as directed.
Taking down existing Rationlisation tranformer from the Plinth, Pole including discinnecting incomming & out going cable connections carefully and shifted/ handedover to storeyard of AGE E/M No I Mhow complete all as specified and directed.
Ashirwad Contractor and Supplier
KSP ENTERPRISES
Sant Construction Co.
JAZZCON ENGINEERS PVT LTD
GUPTA ENGINEERING WORKS
KR POWER INFRA INDIA PVT LTD.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .