Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC FLAT NO 04 3RD FLOOR HARI BHAVAN PLOT NO 44 MAHANT ROAD VILLES PARLE EAST MUMBAI 400057 | MUMBAI SUBURBAN | MAHARASHTRA | 400057 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹44.4 L+₹1.0 L (2.34%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹44.4 L+₹1.1 L (2.50%)Rejected-Finance 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹45.2 L+₹1.9 L (4.32%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹47.0 L+₹3.7 L (8.44%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L5 | Rejected-Finance BEING L5 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
22 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
SPL REPAIR TO SEWAGE LINE, STRUCTURAL IMPROVEMENT TO CERTAIN OTM ACCN ,REPAIR TO DOOR AND DOOR FRAMES, AND CERTAIN MINOR WORKS OF B/R AND E/M AT AFS MADH ISLAND UNDER GE(AF)THANE
2023_MES_582427_2
8262/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
THANE
AS PER REVISED NIT UPLOADED ALONG WITH TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹99,000
Yes
17 Jun 2023
1 Apr 2023
24 Apr 2023
1 Apr 2023
22 Apr 2023
10 Apr 2023
1 Apr 2023 - 10 Apr 2023
Amount
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site complete all as specified and directed by Engineer-in-Charge.
Dismantling of reinforced concrete in slab,chajja, complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in cm 1:6 finished with neeru finish as specified on fair faces of brick work /stone or concrete surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 20 mm thick (15 mm thick backing coat in cement mortar 1:4 and 5mm thick finishing coat in cement mortor 1:6 ) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately) ,complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound ,complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of acrylic water/weather proof exterior emulsion coating over one coat of primer all as per manufactures instructions including preparation of new surfaces of wall, complete all as specified and directed by Engineer-in-Charge.
M&L preparing newly plastered surfaces ,and applying 2 coats of Oil Bound Distemper over a coat of alkali resistant primer Over 1 mm thick wall care putty on walls,complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in cm 1:3 on fair faces of concrete as in soffit/ ceilling or slab, chajjas finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L Complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of newly surfaces of ceiling and applying three coat of white wash complete all as specified and directed by Engineer-in-Charge.
M&L Brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 ,complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified and directed.
Demolition of cement concrete (Unreinforced) in ground floors and pavings n. exc 15cm thickness (Below or above Ground level), complete all as specified and directed.
M&L Providing, cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in cills, steps seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed
Removal of existing concrete including loose/weak concrete from the concrete structure i.e. beams/columns/deckslab etc upto beyond corroded steel reinforcements to a depth of minimum 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around the corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid featheredging and to provide a square edge complete all as specified and directed by Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Preparation of surface and removal of rust in the loosely bonded concrete of the RCC deckslab, beam / girder and piles shall be chipped out using the mechanical cutter exposing the bars and applying Rust Remover using small brush and allow to react it for 16-24 hrs. Before applying protective coating,the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for applying two coats of Anti-Corrosive Primer two component (epoxy anticorrosive zinc rich coating) on reinforcement steel surfaces uniformely. Coating shall be applied by the brush to the exposed and cleaned rebars with an interval of 45 minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for preparation of concrete surfaces by removing loose concrete, dust, dirt etc, cleaning the surface properly and applying one liberal coat of epoxy bonding agent ( two component agent) by brush application complete all as per manufacturer instruction and directed by Engr-in- Charge Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Providing & executing injection/pressure grouting in the cracks in the parent concrete by fixing PVC/Aluminium nipples at 150mm to 200mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout. Moisture insensitive epoxy resin injection material supplied in 1.5 Litre pack which can grout gaps ranging from 0.25mm to 9mm, having mix density 1060 Kg/m3, compressive strength 60 N/mm2, Tensile Strength 20 N/mm2, Flutural strength 45 N/mm2. Pressure grouting shall be carried out after surface preperations includes fixing nipples and filling cracks with epoxy mortar one day before grouting, injecting low viscous grout mechanically about pressure 3.5-7.0 Kg/Cm2, removing nipple after grouting and sealing with epoxy mortar etc complete as directed by Engr - in - Charge. Payment shall be made on actual grout consumed. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Cutting, fabricating new reinforcement Fe500 and fixing with old existing reinforcement which was reduced to 20% or more of its original diameter as provided in original structure and additional steels as directed by EIC to be fixed with chemical anchor grout Lokfix E55 (Styrene free vinyl-ester resin based catridge system for anchoring reinforcement supplied in 300 ml catridge with a single mixer nozzle of Fosroc or equivalent approved make, application includes drilling hole close to old reinforcement bar with suitable drill as per dia of bar, cleaning the hole with wire brush and compressed air, putting Lokfix E55 or equivalent with gun followed by placing rebar with slide rotational motion to avoid air void formation etc complete all as per manufacturer instructions and as directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for Drilling holes into existing concrete substrate for anchoring of new rebars nwith 10mm dia shear connectors at 0.5 mtr c/c and fixed with chemical anchor Lokfix E55 or equivalent - Styrene free vinyl-ester resin based catridge system for anchoring reinforcement supplied in 300 ml catridge with a single mixer nozzle, shall be tested in accordance European approval to EAD-33087-00-0601 for use in post-installed rebar, which supersedes ETAG 001 TR 023 (rebar), LEED compliant VOC Level, Fire resistance<120mins, Seismic C1 testing as part of EAD 330499-00-0601 for specific fastening sizes etc. Typical applications includes drilling hole 14mm dia and 90mm deep as per manufacturers recommendation, cleaning the hole with wire brush and compressed air, putting Lokfix E55 with gun followed by placing shear connector with slide rotational motion to avoid air void formation etc complete as directed by EIC. HSE Guidelines : Recommended to wear tight fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for 50mm thick ( average thickness) modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar on conrete structure. Applying the mortar arround the reinforcement and finishing to bring it in line with existing concrete surface complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
M&L for micro concrete to existing concrete structure including proper tight leak proof shuttering SPL polimer modified cementitious ,low permeable'free flow 'non shrink 'self compacting micro concrete shall be grade M70 as per recommended w/c ratio and pouring as per the required thickness complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
Dismantling wrought iron or mild steel work of any description not otherwise provided for ,complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips ,complete all as specified and directed by Engineer-in-Charge.
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each and removing from site,complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames exc 1.5 sqm & n exc 4 sqm with shutters without taking off shutters from the frame and removing to store ,complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exc 1.00 sqm but n exc 2 sqm ,complete all as specified and directed by Engineer-in-Charge.
S&F solid PVC double door frame of size 50mmx95mm made out of 5mm single side prelam PVC sheet reinforced with MS tube, supplying & fixing in opening as per specification and drawing as per SSR P-I ,complete all as specified and directed by Engineer-in-Charge.
S&F factory made single exstruded WPC (Wood polymer composite) solid door/ window ceosetory window & other frames/ chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K Value 58-60 (suspension Grade) calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100N (Edge), minimum compressive strength of 58N/ mm2 , modules of elasticyty 900N / mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer -in - charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note :- For WPC Solid door/ window frames, minus 5 mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile but no extra payment on this account shall be made ,complete all as specified and directed by Engineer-in-Charge..
S&F factory made single extruded WPC (Wood polymer composite ) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 ((suspension Grade) calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk ) and non toxic additives (maximum toxicity index of 12 for 100 gms) f having minimum frame density of 650 kg/ cum, screw withdrawal strength of1800 N (Face) & 900N (Edge), minimum compressive strength of 50N/ mm2 , modules of elasticyty 850N / mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer -in - charge. Note Stainless steel butt hinges and necessary S S Screws shall be paid separately)
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solventcement, suppling & fixing in the frame at site as per specification & drawing AS PER SSR P-I ,complete all as specified and directed by Engineer-in-Charge.
S&F PVC factory made wire gauged shutter with wire gauge warpped on an additional square 8mm MS solid tube and this tube shall be welded to MS tube. The wires gauge shall be stretched to tighten firmly, PVC door shutter 30mm thick (stiles) consisiting of frame made out of MS tube for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm wigth stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail all as per specification and drawing given in SSR Part II, Schdule of rates 2010 and directed but as in four panels in lieu of two panels. Note : The wire mesh shall be measured separately.
S&F 125mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 ,complete all as specified and directed by Engineer-in-Charge.
S&F 100mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 ,complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long aluminium extruded alloy handles fabricated type anodized ,complete all as specified and directed by Engineer-in-Charge.
S&F 150mm long extruded aluminium alloy handles fabricated type anodized ,complete all as specified and directed by Engineer-in-Charge.
S&F 150mm long aluminium anodized barrel tower bolts of extruded section ,complete all as specified and directed by Engineer-in-Charge.
M&L for cutting holes in bricks walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick ,complete all as specified and directed by Engineer-in-Charge.
S&F in repair 12mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work ,complete all as specified and directed by Engineer-in-Charge.
S&F Hasp and staple aluminium anodised wire type stove enamelled black, including bolt to hinge plate and fixed with screws ,complete all as specified and directed by Engineer-in-Charge.
S&F aluminium alloy anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts 300mm long ,complete all as specified and directed by Engineer-in-Charge.
Taking down aluminium sliding windows of any description and any size and replacing the wornout, broken wiremesh, aluminium sections, glass grill, rubber beading, rollers, locks etc as required and refixing back into the same opening for easy movement of shutters including necessary fittings and fixtures (Note : Items such as i) Wiremesh, ii) Glass, iii) Grill, iv) Rubber beeding, v) Rollers, vi) Locks, vii) Aluminium sections etc will be paid seperately under respective items as supply only)
S&F aluminum anodised frame powder coated( of approved colour) for doors, windows, ventilators with one or more rebates including joining cleat (min powder coating 50 micron) any track sliding windows/ Doors/Partition frames with aluminum sections mentioned in catalogue of approved manufacturer including suitable Nylon beading, channel gasket, nylon rollers, star lock with handle with complete fittings including water tightening using silicon compound all around etc complete all as specified and as directed by Engr - in- Charge. (Note : Glass, wire cloth shall be measured under respective items)
Supply only PVC Star lock for Aluminium windows.
Supply only Nylon / PVC Rollers for Aluminium Windows.
Supply only Rubber beeding suitable for aluminium door/window shutters.
Supply only ordinary sheet glass 4.8mm thick in square exc 0.5sqm in each panes , complete all as specified and directed by Engr-in-Charge..
Supply only Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as directed by Engr-in-Charge.
S&F 300mm mild steel helical door spring including roller plate , complete all as specified and directed by Engr-in-Charge.
Excavationn in trenches n.exc 1.5 mtr wide and n.exc 1.50 mtr depth and getting out in hard/dense soil , complete all as specified and directed by Engr-in-Charge.
Ditto as per Srl Item No 53.00 above but depth exc 1.50 mtr and n.exc 3.00 mtr , complete all as specified and directed by Engr-in-Charge.
Demolition of reinforced cement concrete of any description and in any position , complete all as specified and directed by Engr-in-Charge.
Demolition and breaking up of drain pipes 150mm dia (glazed stone ware, AC or reinforced concrete) set and jointed in cement mortar complete all as specified and directed by Engr - in - Charge.
Demolition and breaking up of drain pipes 100mm dia (glazed stone ware, AC or reinforced concrete) set and jointed in cement mortar complete all as specified and directed by Engr - in - Charge.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in concrete bed to drain pipes including packing and haunching against the sides for 150 mm dia pipes , complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in concrete bed to drain pipes including packing and haunching against the sides for 100 mm dia pipes , complete all as specified and directed by Engr-in-Charge.
M&L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars of 100 mm bore pipes , complete all as specified and directed by Engr-in-Charge.
M&L Reinforced concrete pipes, class NP2, laid and jointed complete with collars of 150 mm bore pipes , complete all as specified and directed by Engr-in-Charge.
M&L Precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coverslabs of manholes with plain faces including necessary form work, placed in position, set in CM (1:6) , complete all as specified and directed by Engr-in-Charge.Note :- Reinforcement shall be measured and paid seperately
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips , complete all as specified and directed by Engr-in-Charge.
M&L for Mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips , complete all as specified and directed by Engr-in-Charge.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips , complete all as specified and directed by Engr-in-Charge.
M&L for Reinforced cement concrete (nominal mix) type B1 1:2:4 using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like , complete all as specified and directed by Engr-in-Charge.
Ditto as per Srl item No 66.00 above but as in lintel/beams
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, n.exc 200 mm thick (Horizontal or sloping) , complete all as specified and directed by Engr-in-Charge.
Ditto as per Srl item No 68.00 above but in beams
Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide ,complete all as specified and directed by Engr-in-Charge..
M&Lfor Pre-cast cement concrete block masonry type C1 (1:3:6) using 20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
Dismantling CI soil, waste and vent pipes of 100/75 mm dia , complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall , complete all as specified and directed by Engr-in-Charge.
Ditto as per Srl item No 73.00 above but for 75mm dia pipe , complete all as specified and directed by Engr-in-Charge.
S&F 110 mm bore dia PVC (SWR) bends in any radius with access door , complete all as specified and directed by Engr-in-Charge.
Ditto as per Srl item No 75.00 above but for 75 mm bore ,complete all as specified and directed by Engr-in-Charge.
S&F 100 mm bore dia PVC (SWR) bends in any radius ,complete all as specified and directed by Engr-in-Charge.
S&F 75 mm bore dia PVC (SWR) bends in any radius ,complete all as specified and directed by Engr-in-Charge.
Demolition of Brick/block masonry built in cement mortar and removing of debris off the land up to 50 Mtr all as directed by Engr - In - Charge in foul condition.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping etc., including weathering, slightly rounded or chamfered and throating with necessary form works , complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in surface channel, drains, benching and finishing the surface even and smooth using extra cement including necessary use and waste of form work complete all as specified and as directed.
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex-tra cement, including forms, moulds, mi- tred/stopped ends etc , complete all as specified and directed by Engr-in-Charge.
M&L rendering 15mm thick in cement mortar 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement mixed with waterproofing compound as per manufacturer's instructions , complete all as specified and directed by Engr-in-Charge. Note : Water proofing compound shall be measured and paid seperately.
M&L rendering 10mm thick in cement mortar 1:4 on fair faces of concrete surfaces finished even and fair without using extra cement mixed with waterproofing compound as per manufacturer's instructions , complete all as specified and directed by Engr-in-Charge.Note : Water proofing compound shall be measured and paid seperately.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: similar small articles conforming to Fe-290 Gde-E-165 , complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) vent cowl 75 mm bore , complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) vent cowl 110 mm bore , complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil , complete all as specified and directed by Engr-in-Charge.
Removing excavated material n.exc. 50m and depositing where directed , complete all as specified and directed by Engr-in-Charge.
M&L for machine cut cuddappa stone slab 20 to 25 mm thick as in cills/jambs of window & door openings, set jointed and pointed in neat cement slurry with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete including 15mm thick backing coat in cement mortar 1:4 , complete all as specified and directed by Engr-in-Charge.
Surface dressing n exc 15 cm deep and getting out in Hard/dense soil , complete all as specified and directed by Engr-in-Charge.
M&L for Hard core, broken to gauge n exc 63mm all as specified and directed , complete all as specified and directed by Engr-in-Charge.
M&L for Cement concrete in foundations, filling and mass concrete type D2 1:4:8 (using 40mm graded stone aggregate) , complete all as specified and directed by Engr-in-Charge.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over cement screed bed of 15mm thick in CM 1:6 , complete all as specified and directed by Engr-in-Charge.
Excavating in post holes (or similar holes) in hard/dense soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm ,complete all as specified and directed by Engineer-in-Charge.
S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 , complete all as specified and directed by Engr-in-Charge.
M&l Painting two coats over a coat of red oxide primer to new steel surfaces of any description, over 10cm in width or girth,not otherwise described including preperation of new surfaces , complete all as specified and directed by Engr-in-Charge.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed 15mm thick in CM 1:6 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing, complete all as specified and directed by Engr-in-Charge.
M&L for kota stone slab 20-25 mm thick in skirting and pillar laid over cement screed 15 mm thick in CM 1:6 base laid and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing , complete all as specified and directed by Engr-in-Charge.
S&F Framed work as in doors/window/ ventilator or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n. exc. 1.5 M in width and 1.5 m in depth and getting out in soft/loose soil , complete all as specified and directed by Engr-in-Charge.
M&L for providing crushed stone sand cushioning to UG cable including punning down of sand in layers , complete all as specified and directed by Engr-in-Charge. Note :- Quantity of Sand will be measured after punning down.
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” LV type1 flat size 250 x 150 x 40 mm laid in trenches, complete all as specified and directed by Engr-in-Charge.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire ,armoured electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 4 Core 25 Sq mm , complete all as specified and directed by Engr-in-Charge.
Supply ,install and testing hi wall split units inverter type with copper bound compressor and capillary tube , indoor & outdoor units complete with cordless remote control unit and with in built Heating & Cooling arrangment, Digital inverter twin rotary, in built air ioniser,Plasma filter for better indoor air quality, with star rating having minimum 5 star rating and EER 3.2 of capacity 2.00 TR, operating at 230 V 50 HZ ,complete all as specified and as directed by Engineer-in-charge.Note: (i) Power supply cable for AC installation upto 5 meter including plug top three pin suitable for existing socket/Metal clad deemed to be included in Quoted rate. (ii) For installation of AC at site if any stand/support or small modification (i.e Preparation of exising old surface or any other minor repair ) required before fixing of AC then it should be included in quoted rate. (iii) The water drain pipe upto 5 meter for AC including cutting and other allied for fixing should be included in quoted rate ,nothing extra shall be paid on this account.(iv) Indoor to outdoor unit connection required at site with insulated copper pipe upto 7.5 meter deemed to be included in Quoted Rate. (v) Quoted quoted rate shall be including Taking down Unserviceable ACs are to be disconnected & deposited to MES Yard, nothing extra shall be paid on this account.
S&F single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 32 Amp 240 Volts complete all as specified and directed by Engineer in Charge.
M&L for Sub Main wiring with two single core 4 Sqmm FRLS insulated multistranded flexible copper conductor cable 660/1100 volts grade drawn in through PVC metallic conduit/ PVC casing and capping with accessories on Surface with and including PVC insulated 4.0 Sqmm single core single strand copper conductor as continuous earth wire in green colour connected to common earth dolly , complete all as specified and directed by Engr-in-Charge. Note:- 1. Two runs of cable and one run of earth wire incl PVC conduit/ PVC casing and capping will be measured and paid one unit.
Supply and fixing of LED Light fittings 1X16 Watt flameproof, CMRI certified recommended for gas/vapour group of IIA & IIIB, zone 1 & 2 and IP 66 protection with pressure die-cast aluminium housing with impact and corrosion resistant complete with all driver, holder, connector accessories. including deep drawn aluminium/ MS housing in grew finish with clear acrylic and cast aluminium pipe mounting attachment with accessories and prewired and in clamp conforming to 66 degree of protection , complete all as specified and directed by Engr-in-Charge.
S&F switch flame proof rotary type with termination box in LM6, 16A Single Pole 250V including all necessary fixing accessories , complete all as specified and directed by Engr-in-Charge.
M&L for Sub Main wiring with two single core 2.5 Sqmm PVC insulated FR multistranded flexible copper conductor cable 660/1100 volts grade drawn in through steel conduit with and including PVC insulated 2.5 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly , complete all as specified and directed by Engr-in-Charge.
M & L for point wiring with PVC insulated unsheathed 1100 Volts grade single core multistranded Copper conductor cable FRLS 1.5 Sqmm drawn in and including steel enamelised conduit and with all accessories, fixed on wall/ ceiling etc with necessary fixing accessories and earth continuity conductor cable of size 1.5 Sqmm green colour Connected to common earth dolly all as specified for the following: (a) One light / fan point controlled by one way switch
Supply install testing and commisioning of energy conversion digital grounding appartus/device Single phase 1 wire 120 KA with inbuilt 100% lighting surge protection, noises, ESD, EPR and abnormal electric characterstics which enter power and other service lines and ensuring clear bonding potential (earth to neutral voltage) less than 1.0 Voltto be connected in parallel to the circuit, conforming to IE, tested and certified as per latest certification ( IEC 61643-1, IEC-61000-4-5, IEC-61000-6-1, IEC-61000-6-3, MIL-STD-810-G, ISO 14001-2004) in prewire metal enclosure with pulverulent body painting including all accessoriesrequired for installation etc complete. Make-Ground Co ltd model No ECA 3G lp-34-40 or DSS Electric or equivalent Note-(a) The equpment will be utilized for sensitive installation, hence technical specificatins should be strictly adhered. (b) one year warranty for the whole equipment from the date of completion and seven year warranty for spare support from the date of completion. (c) Life expactancy is minimum 10 years from the date of completion
M & L for Earth recharger/Earth resistance reducing compound of 6 KG per buckets comprising of ion and catalyser for reduction of earth resistance as well as retaining moisture in the earth pit with certified( ERDA, NABL, ROHS, IS3043, IEEE IS RULES) and without corroding the earth pit material suitable for all type of earth pit all as specified and as directed. Note-(a) Percentage reduction of earth resistance should be min 70 Percentage (b) Earth resistance value should be retain atleast 1.5 years. (c) contractor will submit earth resistance value before and after utilization of material.
Vishal Builders
M/s Mukesh Engineers
venus enterprises
S K ENTERPRISES
C S Sharma and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .