Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L1 | Accepted-AOC Approved by Accepting officer | |
| 2 | L2₹7.4 L+₹43,820 (6.33%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹7.6 L+₹71,765 (10.4%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹9.7 L+₹2.8 L (40.6%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L4 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | M/S JAINENDRA KUMAR JAIN L4 | M/S SHIVA TRADERS L1 | S.R ENGINEER WORKS L3 | AK enterprises L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminum/copper point wiring (light, fan socket or power) complete including fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, floors etc complete all as required and keeping serviceable light fittings in safe custody for reuse in the work or credited to contractor complete all as specified and directed by Engr in Charge. | 223 | Each Point | 10 ₹2,230 Lowest | 10 ₹2,230 Lowest | 25 ₹5,575 | 20 ₹4,460 |
| 2.00 | Taking down existing sub main wiring of any type/size complete from wall and making good the disturbed surface complete all as specified and directed by Engr in Charge. | 230 | RM | 5 ₹1,150 Lowest | 5 ₹1,150 Lowest | 15 ₹3,450 | 25 ₹5,750 |
| 3.00 | Material & labour for point wiring with two single core 1.5 Sqmm FRLSH PVC insulated unsheathed 1100 Volts grade multi stranded copper conductor with one single core 1.50 Sqmm FRLSH PVC insulated unsheathed solid copper conductor as earth continuity conductor drawn through in and including PVC casing caping (ISI Marked) of required size (25x12/32x12mm) along with all fitting/ fixtures such as Tee, Bend, Elbow socket, Saddles etc. and making good the disturbed surface and connecting to common earth dolly complete with concealed/open pressed steel terminal box of suitable size / shape duly painted with black for accommodating switches sockets, regulators with brass screws,washers with hylem sheet of 3mm thick in white / smoke gray/ off white colour for One light point/fan controlled by one, one way 5 Amp switch complete.
Note:- Colour of cables as Phase-Red, Neutral-Black and Earth-Green. | 103 | Each Point | 470 ₹48,410 Lowest | 700 ₹72,100 | 600 ₹61,800 | 595 ₹61,285 |
| 4.00 | All as per item No 3 above but one light point controlled by two, 2-way switches. | 30 | Each Point | 470 ₹14,100 Lowest | 700 ₹21,000 | 600 ₹18,000 | 550 ₹16,500 |
| 5.00 | All as per item No 3 above but one socket outlet 5 Amp controlled by one switch on the same board. | 30 | Each Point | 470 ₹14,100 | 150 ₹4,500 | 150 ₹4,500 | 100 ₹3,000 Lowest |
| 6.00 | All as per item No 3 above but one multi pin socket 5 Amps, independent board complete | 30 | Each Point | 470 ₹14,100 Lowest | 700 ₹21,000 | 500 ₹15,000 | 525 ₹15,750 |
| 7.00 | All as per item No 3.00 here-in-before but point wiring for one 3 pin 15 Amps socket point on independent board with 2.5 Sqmm size FRLSH PVC insulated, unsheathed, multi stranded, copper conductor cables 1100 volt grade and with 2.5 Sqmm FRLSH PVC insulated unsheathed, single core, multistranded copper conductor cable 1100 volt grade as earth wire complete. | 30 | Each Point | 650 ₹19,500 Lowest | 800 ₹24,000 | 650 ₹19,500 Lowest | 685 ₹20,550 |
| 8.00 | Supply & fixing, in repairs, sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC casing and caping of 25/32mm x 12mm size med grade including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 4 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length | 100 | RM | 350 ₹35,000 | 170 ₹17,000 Lowest | 400 ₹40,000 | 315 ₹31,500 |
| 9.00 | All as per item No 08 above but submain with 6 sqmm complete all as specified and directed by Engr in Charge. | 100 | RM | 500 ₹50,000 | 250 ₹25,000 Lowest | 440 ₹44,000 | 370 ₹37,000 |
| 10.00 | Supply & fixing, in repairs, sub-main wiring with 4 single core, 10 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC casing and caping of 25/32mm x 12mm size med grade including drawing 02 run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 10 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length | 30 | RM | 600 ₹18,000 | 330 ₹9,900 Lowest | 890 ₹26,700 | 780 ₹23,400 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
16 Jul 2026, 6:00 pmClosed
Madan Lal Beniwal, IDSE, AEE Civil
AGE I DHANA PIN 470228, DIST SAGAR, MP
REPAIR / MAINT / REPLACEMENT OF ELECTRIC WIRING WITH FITTINGS AND FIXTURES, SUB MAIN WIRING, DBs WITH EARTHING IN MD ACCN OF NCO ACADEMY AT MIL STATION DHANA.
2026_MES_772994_1
8300/DH/24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Dhana
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Saugor
₹20,000
Yes
20 Aug 2026
18 Jun 2026
18 Jul 2026
18 Jun 2026
16 Jul 2026
2 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully aluminum/copper point wiring (light, fan socket or power) complete including fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, floors etc complete all as required and keeping serviceable light fittings in safe custody for reuse in the work or credited to contractor complete all as specified and directed by Engr in Charge. | 223 | Each Point | - | - |
| 2 | Taking down existing sub main wiring of any type/size complete from wall and making good the disturbed surface complete all as specified and directed by Engr in Charge. | 230 | RM | - | - |
| 3 | Material & labour for point wiring with two single core 1.5 Sqmm FRLSH PVC insulated unsheathed 1100 Volts grade multi stranded copper conductor with one single core 1.50 Sqmm FRLSH PVC insulated unsheathed solid copper conductor as earth continuity conductor drawn through in and including PVC casing caping (ISI Marked) of required size (25x12/32x12mm) along with all fitting/ fixtures such as Tee, Bend, Elbow socket, Saddles etc. and making good the disturbed surface and connecting to common earth dolly complete with concealed/open pressed steel terminal box of suitable size / shape duly painted with black for accommodating switches sockets, regulators with brass screws,washers with hylem sheet of 3mm thick in white / smoke gray/ off white colour for One light point/fan controlled by one, one way 5 Amp switch complete.
Note:- Colour of cables as Phase-Red, Neutral-Black and Earth-Green. | 103 | Each Point | - | - |
| 4 | All as per item No 3 above but one light point controlled by two, 2-way switches. | 30 | Each Point | - | - |
| 5 | All as per item No 3 above but one socket outlet 5 Amp controlled by one switch on the same board. | 30 | Each Point | - | - |
| 6 | All as per item No 3 above but one multi pin socket 5 Amps, independent board complete | 30 | Each Point | - | - |
| 7 | All as per item No 3.00 here-in-before but point wiring for one 3 pin 15 Amps socket point on independent board with 2.5 Sqmm size FRLSH PVC insulated, unsheathed, multi stranded, copper conductor cables 1100 volt grade and with 2.5 Sqmm FRLSH PVC insulated unsheathed, single core, multistranded copper conductor cable 1100 volt grade as earth wire complete. | 30 | Each Point | - | - |
| 8 | Supply & fixing, in repairs, sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC casing and caping of 25/32mm x 12mm size med grade including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 4 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length | 100 | RM | - | - |
| 9 | All as per item No 08 above but submain with 6 sqmm complete all as specified and directed by Engr in Charge. | 100 | RM | - | - |
| 10 | Supply & fixing, in repairs, sub-main wiring with 4 single core, 10 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC casing and caping of 25/32mm x 12mm size med grade including drawing 02 run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 10 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length | 30 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
24SoC.pdf
Additional Documents • 0.56 MB
BOQ_865717.xls
BOQ • 0.48 MB
24TENDERPAGES.pdf
Tender Documents • 2.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .