| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | ₹3.1 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹3.2 Cr+₹10.6 L (3.41%)Rejected-Finance | ₹3.2 Cr+₹10.6 L (3.41%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹3.3 Cr+₹17.3 L (5.58%)Rejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹3.3 Cr+₹17.3 L (5.58%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹3.4 Cr+₹26.7 L (8.64%)Rejected-Finance FARIDABAD | FARIDABAD | HARYANA | 121001 | ₹3.4 Cr+₹26.7 L (8.64%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹3.4 Cr+₹29.9 L (9.68%)Rejected-Finance C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹3.4 Cr+₹29.9 L (9.68%) | L5 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | M/S Chhavi Constructions Co L6 | M/s Arihant Builders L3 | A R construction L1 | Third Wave Services Pvt Ltd L8 | L G BUILDERS L5 | Shivom Projects Private limited L7 | ASSOCIATED CONSTRUCTION CO. L4 | P R Constructions L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Preventive treatment against the danger of carbonation in exposed faces of RCC members :-
(i) Cleaning existing surfaces of RCC members and making surface free of loose material, oil, grease etc. by vigorous wire brushing including light grit blasting where necessary as recommended by Engr-in-charge.
(ii) Further, cleaning using biocide(as recommended by manufacturer) to ensure that surface is free of algae and fungus and no trace of paint (any type) left out. Sand blasting to be done to remove trace of paint.
(iii) Cleaned surface to be allowed to dry.
(iv) Spray a coat of primer (as recommended by manufacturer) over dry cleaned surface as required prior to final finish. Primer shall be diluted in proposition 2:1 with mineral turpentine. After application, primer shall be allowed to dry for 03 hours or as directed.
(v) Apply a coat of neat Aliphatic Acrylic anti-carbonation (ACC) over the primed surface with air / spray gun at nominal rate of 3.5 ltrs per sqm as recommended by manufacturer.
(vi) Apply a more coat of Aliphatic Acrylic anti-carbonation (ACC) after 5-6 hours as recommended by manufacturer complete all as specified and directed. (vii) Sprinkle sand cover over surface to receive new. | 100 | Sqm | 350 ₹35,000 | 150 ₹15,000 Lowest | 293 ₹29,300 | 275 ₹27,500 | 300 ₹30,000 | 180 ₹18,000 | 390 ₹39,000 | 200 ₹20,000 |
| 2.00 | M&L for followings :-
(i) Removing plaster & finishes all around the coloumns, slabs & beams
(on all four sidescription of column to full height , three sidescription of beam to entire span & bottom of slab to area as directed)
(ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible)
(iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed)
(iv) Cleaning exposed concrete substrate by using water jet.
(v) Removing visible rust along the length of reinforcement using hand tools as approved.
(The Engr-in-charge may order sand blasting if rust is approved)
(vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed. | 200 | Sqm | 450 ₹90,000 | 150 ₹30,000 | 123 ₹24,600 | 100 ₹20,000 | 225 ₹45,000 | 90 ₹18,000 Lowest | 90 ₹18,000 Lowest | 100 ₹20,000 |
| 3.00 | M&L for providing rust proof /anti corrosive treatment to bars :-
(i) cleaning of all exposed bars (new & old) alround
(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer
(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer.
Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. Superficial area of member to be considered for measurement. | 100 | Sqm | 900 ₹90,000 | 150 ₹15,000 | 123 ₹12,300 | 475 ₹47,500 | 225 ₹22,500 | 360 ₹36,000 | 390 ₹39,000 | 100 ₹10,000 Lowest |
| 4.00 | M&L for providing PMM (Polymer modified cementitious mortar) :-
(i) Dry sub strate surface and free of debris & dust
(ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).
(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness.
Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.
(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. | 90 | Sqm | 1,200 ₹1,08,000 | 900 ₹81,000 | 1,313 ₹1,18,170 | 1,600 ₹1,44,000 | 900 ₹81,000 | 990 ₹89,100 | 1,290 ₹1,16,100 | 600 ₹54,000 Lowest |
| 5.00 | M&L for Providing & Pouring Micro concreting M-40 grade :-
(i) Dry concrete substrate surface and free of debris & dust
(ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).
(iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed.including M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed.
Note : Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured.
Note : The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item. | 2 | Cum | 40,000 ₹80,000 | 37,000 ₹74,000 | 44,300 ₹88,600 | 65,000 ₹1,30,000 | 60,000 ₹1,20,000 | 27,000 ₹54,000 | 49,000 ₹98,000 | 12,000 ₹24,000 Lowest |
| 6.00 | S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. | 450 | Kg | 100 ₹45,000 | 85 ₹38,250 | 83 ₹37,350 Lowest | 88 ₹39,600 | 85 ₹38,250 | 90 ₹40,500 | 99 ₹44,550 | 120 ₹54,000 |
| 7.00 | M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 53 grade and two part of sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. | 200 | Sqm | 1,500 ₹3,00,000 | 1,200 ₹2,40,000 | 1,233 ₹2,46,600 | 1,000 ₹2,00,000 | 900 ₹1,80,000 | 900 ₹1,80,000 | 890 ₹1,78,000 Lowest | 1,200 ₹2,40,000 |
| 8.00 | Demolition of RCC of any description, in any position roofs, floors (other than ground floors), beams staircases, landing, chajjas, RCC overhead tank and similar suspended work and Removing excavated material /demolition material exc. 1.50 km but n exc.5 km including taking down from upto four storey complete all as specified and directed. | 72.32 | Cum | 800 ₹57,856 | 200 ₹14,464 Lowest | 543 ₹39,269.76 | 1,000 ₹72,320 | 250 ₹18,080 | 450 ₹32,544 | 290 ₹20,972.8 | 300 ₹21,696 |
| 9.00 | S&F Factory made modular FRP Chajjas with MS Flats 40 x 2mm, minimum 06 Nos Hold and Fastner including cutting/chesling of required thickness (As per manufacturer instruction) of wall or as per direction of Engr-in-Charge for upto 4th storey of building and making good disturb portion including demolition of reinforcement cement concrete chajjas as suitable method and as per direction of Engr-in-Charge, all as specified and directed.Drawing for the complete Job is enclosed and as per sample kept on custody of AGE B/R-I of GE (South) office.
Make - FIBREWAYS TECHNOLOGY or equivalent. | 223.02 | Sqm | 5,200 ₹11,59,704 | 4,850 ₹10,81,647 | 3,993 ₹8,90,518.86 | 4,230 ₹9,43,374.6 | 2,100 ₹4,68,342 | 2,700 ₹6,02,154 | 1,890 ₹4,21,507.8 Lowest | 4,800 ₹10,70,496 |
| 10.00 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. | 120.96 | Sqm | 450 ₹54,432 | 300 ₹36,288 | 243 ₹29,393.28 | 600 ₹72,576 | 250 ₹30,240 | 250 ₹30,240 | 190 ₹22,982.4 Lowest | 250 ₹30,240 |
Tender Value
₹4.4 Cr
EMD Value
₹5.2 L
Closing Date
9 Dec 2025, 6:00 pmClosed
HQ Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone Delhi Cantt-10
SPL REPAIR OF JCO MD ACCN BLDG NO P-85, P-90, P-100, P-107, P-136, P-137 AT VRC OF IHQ MOD ARMY UNDER GE SOUTH, DELHI CANTT-10
2025_MES_739399_1
CEDZ/TOKEN-39 OF 2025
Open Tender
Civil Works
Item Rate
270 days
Delhi Cantt-10
As per NIT documents
10 documents required · 10 mandatory
₹2,000
GE South
₹5.2 L
Yes
1 Apr 2026
12 Nov 2025
16 Dec 2025
12 Nov 2025
9 Dec 2025
3 Dec 2025
12 Nov 2025 - 19 Nov 2025
S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 53 grade and two part of sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
Demolition of RCC of any description, in any position roofs, floors (other than ground floors), beams staircases, landing, chajjas, RCC overhead tank and similar suspended work and Removing excavated material /demolition material exc. 1.50 km but n exc.5 km including taking down from upto four storey complete all as specified and directed.
S&F Factory made modular FRP Chajjas with MS Flats 40 x 2mm, minimum 06 Nos Hold and Fastner including cutting/chesling of required thickness (As per manufacturer instruction) of wall or as per direction of Engr-in-Charge for upto 4th storey of building and making good disturb portion including demolition of reinforcement cement concrete chajjas as suitable method and as per direction of Engr-in-Charge, all as specified and directed.Drawing for the complete Job is enclosed and as per sample kept on custody of AGE B/R-I of GE (South) office. Make - FIBREWAYS TECHNOLOGY or equivalent.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for RCC 1 : 2 : 4 type B0 using 12.5 mm graded stone agg as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Dismantling Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. each layer complete all as specified and directed.
Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Removing soil excavated material exc. 1.5Km but n exc 5km and depositing where directed at above the starting point complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 (using 12.5 mm graded stone aggregate) on roof padding surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for screed bed 10 mm thick (average) plaster on concrete surfaces in CM (1:3) on roof, mixed with water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified and directed. (Water proofing compound shall be measured and paid seperately).
M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints complete all as specified and directed..
S & F for Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner complete all as specified and directed..
Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specially provided for complete all as specified and directed..
M & L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs ,edging of path area or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete all as specified and directed.
Demolition of stone slab and tiles of any description or thickness on cooking platform, floors, aprons etc laid bedded and pointed in any morter complete all as specified and directed
M & L for Granite (of any type) work, 18-20 mm thk (table rubbed and polished) in steps,jambs,pillars, window-cills, cooking platforms with necessary hole for gas pipe where ever required and likes on cement mortar bedding of 20 mm in CM 1:4 including pointing in white cement using marble dust with admixture of pigment to match including rounded edges with shade of granite complete all as specified and directed.
M&L for machine cut kota stone slab flooring, and (one Pieces) as in skirting and riser, 20-25 mm thick over cement screed bed 20mm thick with CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for machine cut kota stone slab 20-25mm thick in riser, of steps, skirting, dado and pillar laid over 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps cooking platefom,and other similar situations complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and
directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in cement mortar (1:3) complete all as specified and as directed.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including screed bed or bedding layer of mortar 15mm thick in CM 1:4 complete all as specified and directed.
S & F for glazed Ceramic tiles 9 to 10 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm ( size 600 mm x 600 mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for 15mm thick screed bed or bedding in CM 1:4 complete all as specified and directed
Demolition of cement concrete in above ground floors exc 15 cm thick above ground floors complete all as specified and directed..
M&L for 10 mm thick cement plaster on brick/ concrete surface in CM 1:3, finished even and fair surface with out using extra cement but mixing water proofing compound at the rate of 2% of cement by weight complete all as specified and directed. (WPC shall be paid separately).
M&L Cement concrete Type F2 (1:5:10) using 40 mm graded stone aggregate in mass concrete in sunken floor complete all as specified and directed.
M&L for 25mm thick cement concrete type B-0 1:2:4 (12.5mm graded aggregate) as in sub floors finished rough complete all as specified and directed..
Supply only PVC low level white flushing cistern valveless symphonic action type 10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified and directed.
S&F elegent mirror PVC cabinet (PTMT alloy) complete all as specified and directed.
S & F in repairs Chromium plated brass overhead shower rose 125mm with arm complete all as specified and directed.
S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet for kitchen with plug, washers, waste pipe, waste coupling incl fixing cast iron cantilever bracket connecting union over all size 495x420mm with bowl size410x330x160mm complete all as specified and directed.
Taking up or down steel tubing 15 mm bore and connection including cleaning for refixing. complete all as specified and directed.
Taking up or down steel tubing 20 mm bore and connection including cleaning for refixing. complete all as specified and directed.
Cutting chases or making holes, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed..
S&F 20mm outer dia CPVC pipes SDR 11 with and including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F 20mm outer dia CPVC ball valve/gate valve complete all as specified and directed
M&L for rotational moulded polyethylene water storage tanks white colour 500 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT float valve, lid tank cover for polyethylene and polyethylene ball including taking out existing unserviceable overhead tank of any description including fitting and fixtures complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 m in depth for manholes & sewage lines and getting out in soft/loose soil complete all as specified and directed..
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specifi
S & F CI pipe in any length with or without ears, with cement joints, laid in trenches or floors of 100 mm dia sand cast pipe (GT to First MH) complete all as specified and directed.
S&F for 110 PVC (SWR) Tee with door plate complete all as specified and as directed.
S&F for 75 mm PVC (SWR) Tee with door plate complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in solvent cement concrete complete all as specified and as directed.
S/F PVC (SWR) 75 mm pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears including clamp as required complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) on floor surface finished even and smooth without using extra cement complete all as specified and directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete.
M & L rendering 10 mm thick in cement mortar 1: 6 on faces of brick work or concrete surfaces, finished even and smooth complete all as specified and directed.
M&L rendering 10 mm thick in cement mortar 1: 6 and top layer 5 mm thick in cement mortar 1: 4 mixing water proofing compound on faces of brick work or concrete surfaces, finished fair and even complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 50 sqmm,3.5 core on wall and trenches complete all as specified and directed.
Supply only liquid water proofing compound all as specified and directed
M&L Rendering 5 mm thick in cement mortar 1: 3 on concrete surfaces of ceiling,chajja,etc finished even and smooth complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing tretament, by rubbing brooming down, washing with water etcand providing and applying 1 mm thickness over plastered surfaces to prepare the surface even and smooth and finishing walls with acrylic smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer @ applied @ 2.20 Kg/10Sqm) complete all as specified and directed.
M&L for preparation of new surfaces (Plastered or unplastered) of wall and applying two coat of oil bound distemper over chalk whiting on plastered surfaces preparatory to distempering complete all as specified and directed.
M&L for old decorated surfaces plastered or unplastred surfaces of walls and complete removal of existing treatment by rubbing brooming down washing with water etc applying two coat of oil bound distemper over chalk whiting on plastered surfaces preparatory to distempering complete all as specified and directed.on wall complete all as specified and directed.
M&L for preparation of new surfaces (Plastered or unplastered) of ceiling and applying two coats of oil bound distemper over chalk whiting on plastered surfaces preparatory to distempering complete all as specified complete all as specified and directed.
M&L complete removal of existing treamnet for preparation of old surfaces (Plastered or unplastered) of ceiling and applying two coats of oil bound distemper complete all as specified and directed.
Demolition of brick work built in cement or cement lime mortar complete all as specified and directed.
M&L brick work in cement mortar (1:6) using sub class 'B' bricks, straight or curved on plan exc 6 mtr mean radius complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows & other frames/chowkhat of size 65 x125 mm comprising of vigin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ricehusk/wheat husk) and non toxicadditives (maximum toxicity index of 12 for 100 g,s) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.(MS hold fast/hugs or SS dash fasteners shall be paid for separately) Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows & other frames/chowkhat of size 65 x100 mm comprising of vigin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ricehusk/wheat husk) and non toxicadditives (maximum toxicity index of 12 for 100 g,s) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. .(MS hold fast/hugs or SS dash fasteners shall be paid for separately) Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account
shall be made.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed.
Providing 35mm thick FACTORY MADE B/S PRELAM WIRE MESH SOLID PVC DOOR SHUTTER consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15mm x 15mm for top, lock & bottom rails. M.S. frame shall have a coat of metal primer of approved make and manufacturer. 19mm x 19mm M.S. square tubes shall be covered with heat moulded Prelam sheet 'C' channel made from 5mm (±0.25) thick PVC Sheet of Density 600 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company, of size 35mm thickness, 115mm width out of which 100mm shall be flat and 15mm shall be bent in 90° angle on either side forming stiles,one of the 90° bend edge is cut from stiles as well as rails to nail from inner side of door to hide wire mesh fixing steel screws. 5mm (±0.25) thick 140mm wide PVC sheet out of which 125mm shall be flat and 15mm shall be bent in 90° on the inner side to form top and bottom rail and 155 mm wide PVC sheet out of which 100 mm shall be flat and 15mm shall be bent in 90° on both side to form lock rail. An additional 5mm (±0.25) all as specified and directed.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows & other frames/chowkhat of size 45 x 70 mm comprising of vigin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ricehusk/wheat husk) and non toxicadditives (maximum toxicity index of 12 for 100 g,s) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed..(MS hold fast/hugs or SS dash fasteners shall be paid for separately) Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F factory made Aluminium window as per TD drg No. CEDZ/D-316 with following specifications: (i) outer frame of size 40mmx114mm with 1.3mm thickness, corner 45 degree cut aluminium welded (ii) center mullion of size 40mmx65mm (iii) welded shutter (02 nos) of size size 40mmx60mmx1.3mm thickness 45 degree cut mechanically joint with 6mm allen key bolt clamp with 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock, aluminium kobra hinges 2 Nos per shutter (iv) 12mm SS 202 grade round bar safety grill at 100mm cc distance modified to 150mm cc distance in front of handle, welded at both ends with 6mm SS 202 grade round bar (v) Welded wire mesh shutter(02 nos) of size 40x18mmx1.3mm thickness 45 degree cut with 0.45mm nominal dia of SS wire mesh, SS 75mm long hinges & PVC magnet. (vi) Entire window shall be powder coated with pure polyster coat of any shade as approved by GE (vii) Window shall have provision for installation of window AC/Desert Cooler and provn of window glass shutter, wire mesh, grill and necessary fittings and locking arrangement for subject portion will be modified as per ground requirement during the execution as per direction of Engr-in-charge. (viii) Window shall be installed with silicone complete all as specified and directed by Engr-in-charge.
S & F for mild steel, 300 mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F 100mm size butt hinges stainless steel of AISI 304 complete all as specified and directed.
S&F 300 mm long, stainless steel of AISI 304 grade, sliding door bolt with hasp, staple (bolt type) and fixing clipss of sheet, cast or extruded sections and fixing bolts and fixed etc complete all as specified and directed.
S&F stainless steel of AISI 304 grade barrel tower bolt 200 mm long, extruded section, etc complete all as specified and directed.
S&F stainless steel of AISI 304 grade handle of size 200mm size long etc. complete all as specified and directed.
S&F brass magic eye for panelled/flush shutter 35mm thick complete all as specified and directed.
M&L for 18 mm thick wood plastic composites (WPC) board for shutters, 100% solid with density not less than 650 Kg per cubic meter , one side wood grain finished laminated for exposed/external surface , fixed with screws fitted under or above the kitchen cooking platform and/or other platform including all necessary fittings and fixtures like nickle plated clip hinges, handles, knobs, channels etc complete all as specified and directed. Note : (a) Pattern & design of WPC board to be decided by GE. (b) Locking arrangement shall be provided in all shutters. The rate quoted by the tenderer shall be included for the same.
M&L for 18 mm thick wood plastic composites (WPC) board for partitions, 100% solid with density not less than 650 Kg per cubic meter , both side white finished laminated for exposed/external surface , fixed with screws fitted under or above the kitchen cooking platform and/or other platform including all necessary fittings and fixtures complete all as specified and directed. Note : (a) Pattern & design of WPC board to be decided by GE.
S&F brass chromium plated tubular hanger rod 20 mm dia with suitable brackets complete all as specified and directed.
S&F for PVC magnetic door catches of kitchen cabinet and similar work fixed with MS screws complete all as specified and directed..
S&F SS tower bolt size 125mm complete complete all as specified and directed..
Per Ten Sqm
Per 10 RM
Each Block
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified.
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm
M&L for following point wiring complete with stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through new concealed rigid PVC conduit and including replacement of existing sunken terminal boxes with modular sunken terminal box 2mm thick of required size and modular white cover plate with all accessories including 1.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good to disturbed surface complete all as specified and directed . Note :- 1. The Rate is inclusive cutting/chasing and making good disturbed surface with cement mortar 1:3 and same surface finishes with the adjoining surface of disturbed area . 2. At roof slab conduit wiring will be done through New PVC rigid surface conduit .
M&L for point wiring for one 3 pin socket outlet, 15 amps on independent board with stranded copper conductor 2.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through new concealed rigid PVC conduit and including replacement of existing sunken terminal boxes with modular sunken terminal box 2mm thick of required size and modular white cover plate with all accessories including 2.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good to disturbed surface complete all as specified and directed . . Note :- The Rate is inclusive cutting/chasing and making good disturbed surface with cement mortar 1:3 and same surface finishes with the adjoining surface of disturbed area .
S&F of Electronic fan regulator suitabe for BLDC ceiling fan complete all as specified and directed by Engineer in Charge.
M&L for opening of hole through out the wall as suitable for exhaust fan of size 300mm sweep and fixing of nut-bolts with 4" anchor fastner of suitable size and making food the disturbed surface and all as per site requirement complete all as specified and directed by Engr-in-Charge. Note : The rates are inclusive in respect of under this item as above hole opening civil work with MS faster bolt of 8mm dia and 100mm (minimum) long for fixing of exhaust fan and MS fastner clamps strip 38 mm wide and 5mm thick (min) to hold exhaust fan.
One light /fan/Bell point/security light controlled by one way switch
dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing complete all as specified & directed.
One 3 pin socket outlet 5 amps on same board
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand all as specified and directed.
Removing excavated soils exc. 500m and and n. ecx 500 mtr depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
M&L broken stone boulder hard core broken to gauge not exc 63 mm complete all as specified and directed.
Taking down carefully the old unserviceable Aluminium/copper point wiring (light, fan, socket or power) complete with fitting such as switches, ceiling roses, pendants, sockets, regulators, etc. and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area i.e. with OBD/colour wash/white wash as the existing finish complete all as specified and directed.
M&L for point wiring for one 3 pin socket outlet, 20 amps on independent board with stranded copper conductor 4.0 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in & including concealed rigid PVC conduit and including modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 4.0 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good to disturbed surface complete all as specified and directed . . Note :- The Rate is inclusive cutting/chasing and making good disturbed surface with cement mortar 1:3 and same surface finishes with the adjoining surface of disturbed area .
S&F of Switch modular type, 1Module, 6 Amps, one way complete all as specified and directed .
S&F of Socket outlet modular type 2M, 3 pin, 6 Amp complete all as specified and directed .
S&F Modular AC box with socket and MCB SP 20 Amp complete with Metal box , white colour plate and frame complete in replacement of sheet metal enclosures as per site requirement , complete all as specified and directed.
S&F of Switch modular type 1M, 16 Amp with red indication light complete all as specified and directed . Notes :- One power point point wiring shall be provided on one circuit of one point only.
S&F in Socket outlet modular type 2M, 3 pin, 16 Amp complete all as specified and directed .
S&F of electric bell ding dong AC, 230 volts single phase complete all as specified and directed by Engr -in-Charge.
S&F of Bell push modular type 1M 5/6 Amp complete all as specified and directed .
Taking down unserviceable sub main wiring twin core of any size complete and making good disturbed surface complete all as specified and directed.
S&F of Wall mounted LED Integrated Batten T5 20 Watt - 4Ft White, indoor decorative PVC extruded T5 LED battern-Integrated complete all as speficied and directed by Engr-in-Charge.
S&F of Wall mounted LED Integrated Batten T5 10 Watt-2 Ft White, indoor decorative PVC extruded T5 LED battern -integrated type complete all as speficied and directed by Engr-in-Charge.
M&L for sub main wiring of two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn in & including new PVC rigid concealed conduit complete all as specified and directed . Note :- (i) Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour. (ii) Two runs of cable for phase & neutral , one run of cable for earth & one run of PVC conduit will be measured and paid as one unit length. (iii) The rates are inclusive of Cutting / chasing and making good to disturbed surface with cement mortar 1: 3 and same surface finishes with the adjoining surface of disturbed area .
Supply fix batten holder PVC insulated body complete all as specified and directed .
S&F of LED lamp 12 Watt LED Re-charable Bulb complete all as specified and directed.
Taking down of ceiling fan and keeping in safe custody and refixing it back after completion of B/R repair work with running condition without any extra costcomplete all as specified and directed at site.
Supply and fixing ceiling fans complete with blades, down rods, with remote and all accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) Existing old ceiling fan to be taken down and deposit to the MES Yard completed ass as specifed and directed.
S&F of steel body exhaust fan 300 mm sweep, 230 Volts with min 800CMH , louver and copper wound including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts of suitable size and making good the disturbed surface of wall with OBD/White wash to match with complete all as specified and directed.
Taking down of Exhaust fan and keeping the same in safe custody for refixing it back after B/R repair work complete with louvers flap including all fixing item like fastner/bolt etc completed all as specified and and directed.
S&F in replacement decorative wall light mounting suitable for LED lamp upto 12 Watt including all connections complete all as specified & directed.
S&F in replacement of LED bulk head in engineering plastic housing with clear prismatic diffuser, 10W WHITE including all accessories connecting up twin core flexible copper conductor cable complete all as specified & directed.
S&F of polycarbonate ceiling rose surfaces minimum size 65x50mm with three terminals complete all as specified and directed .
Taking down of geyser and keeping the same in safe custody for refixing it back after B/R repair work complete all as specified and and directed.
S&F PVC connection with brass nipple 15 mm x 600 mm long with ISI marked, stainless steel, suitable for hot and cold water of 25 ltrs capacity of geyser as hot and cold water connection complete all as specified and directed.
Supply & Fixing in replacement of sheet metal enclosure V TPN 4 way MCCB 125A, 4P, Double door DB, IP-43, bus bar, neutral link earth bar and din rail complete all as specified and directed.
Supply & Fixing in replacement of on distribution board MCCB 125 Amps, 4 Pole, 415 Volts with 16 kA including electrical connection with bus bar or incomer with appropriate size of aluminium lugs and insulation packing complete all as specified and directed .
Boring holes under road pavement by bocky manually in any type of soil upto 50mm bore complete all as specified and directed.
Supply and fix in replacement of MCB DB SPN 12 Way with metal double door, (IP43 Protection) flush mounting epoxy powder control having 100 Amps rated bus bar complete all as specified and directed .
M&L in replacement MCB SPN 'C' curve 40 Amps 240 Volts , 10 KA complete all as specified and directed
M&L in replacement MCB SP 'C' curve 06 to 32 Amps 240 Volts complete all as specified and directed .
M&L in replacement MCB SP 'C' curve 40 Amps 240 Volts complete all as specified and directed .
One 3 pin socket outlet 5 amps point on independent board
All as per item no 139 here in before but through existing concealed PVC conduit for One light /fan/Bell point/security light controlled by one way switch
All as per item no139 here in before but through existing concealed PVC conduit for One 3 pin socket outlet 5 amps on same board
All as per item no139 here in before but through existing concealed PVC conduit for One 3 pin socket outlet 5 amps point on independent board
All as per item no 143 here in before but through existing concealed PVC conduit 3 pin socket outlet, 15 amps on independent board
Suply and fixing of PVC conduit medium grade of size 15mm TV conection and socket telephon socket complete all as specified and as directed.
Suply anf fixing TV Co-axial socket 1 module complete all as specified and as directed.
Supply and fixing white cover plate with frame 1 module complete all as specified and as directed.
Taking down Electric/Electronic KWH meter and refixing it back after Submain wiring and connecting up complete all as specified and as directed.
S&F in replacement Sheet metal enclosure of size 350 x300 x 150 mm suitable for mounting Single phase electric meter fabricated from 2mm thick CRCA sheet with anti corrosive dust and vermin proof complete all as specified and as directed.. Note:- The meter cover shall have a fully transparent window. The window shall be of transparent, high grade UV stabilized engineering plastic for easy reading of all the displayed values/parameters and observation of operation indicator. The window shall preferably be an integral part of meter cover complete all as specified and as directed.
Supply and fixing flush metal box 1 module complete all as specified and as directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
uploadtender.rar
Tender Documents • 1.97 MB
BOQ_827968.xls
BOQ • 0.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .